Why is it recommended to use more than one range while  troubleshooting a device?

1 Answer

Answer :

Some defective devices may appear to be good in certain  ranges.

Related questions

Description : What are two types of checks used in troubleshooting power supplies?

Last Answer : Visual and signal tracing.

Description : What is the most important thing to remember when troubleshooting?

Last Answer : Safety precautions.

Description : What are two types of checks used in troubleshooting power supplies?

Last Answer : Visual and signal tracing.

Description : What is the most important thing to remember when troubleshooting?

Last Answer : Safety precautions.

Description : What is the most preferred method of troubleshooting?

Last Answer : Testing components by comparison

Description : What two features make the Huntron Tracker 2000 a widely used troubleshooting tool?

Last Answer : It eliminates the need for multiple pieces of test equipment and it is lightweight and portable

Description : When troubleshooting electronic equipment, the FIRST step to be taken before testing the circuit voltage is to _________. A. set the meter to the lowest range B. check the voltage supply from the power source C. remove the suspected component D. check the current flow through the circuit

Last Answer : Answer: B

Description : My Kindle Fire seems to steadily lose battery life even while it's in sleep mode - troubleshooting advice?

Last Answer : Sounds pretty normal to me.

Description : In order to prevent the winch shown in the illustration from turning while troubleshooting the controller circuit, _________________. EL-0102 A. set the dynamic brake by clamping contact 'DB' closed B. set the ... at 'B1' and 'B2' D. open the test link preventing current flow to the armature

Last Answer : Answer: D

Description : When is an optical power meter measurement recommended for conducting field measurements on installed optical fiber cables or cable plants?

Last Answer : When an installed optical fiber cable or cable plant is less than 50 meters in length.

Description : When troubleshooting most electronic circuits, 'loading effect' can be minimized by using a voltmeter with a/an ___________________. A. input impedance much greater than the impedance across which the voltage ... sensitivity of less than 1000 ohms/volt D. sensitivity of more than 1000 volts/ohm

Last Answer : Answer: A

Description : What is the recommended minimum range of illumination required by BS EN 970 for inspection of a welded surface? a) 90 to 125 lux b) 150 to 250 lux c) 350 to 500 lux d) 35 to 50 lux

Last Answer : c) 350 to 500 lux

Description : For joints in service in the creep range which of the following is recommended by ASME B16.5? a) Replacement of the joint after 1,000,000 hours of service. b) Periodic tightening of ... the material operates in the creep range. d) Regular flow detection inspection of the piping to fitting welds.

Last Answer : b) Periodic tightening of the bolts to prevent leakage.

Description : When troubleshooting motor controllers, a shorted relay or contactor coil is often indicated by _______________. A. a resistance reading of 'infinity' on an ohmmeter B. charred insulation and/or a blown ... of the coil's leads to ground D. a higher-than-normal voltage reading across the winding

Last Answer : Answer: B

Description : I need C troubleshooting: When i include a library do i have to do something more in order to have its functions work in my script?

Last Answer : Are you getting any other errors, like “math.h” not found? Actually, IIRC, not finding an include is just a warning…

Description : When backing up an IOS device to cloud what is the first recommended step?

Last Answer : connect to WIFI

Description : Which electronic book device is recommended most for the elderly?

Last Answer : A Nook is most recommended for the elderly, but please purchase a light to go along with it so their eyes may not be harmed. Any product is good but Nook is the best.

Description : When troubleshooting electronic equipment, you should use a high impedance multimeter ________________. A. to prevent excess current flow through the meter that would damage it B. for AC measurements only ... being tested D. so as not to load down the circuit and obtain erroneous voltage readings

Last Answer : Answer: D

Description : In the actuator arm assembly of a hard disk drive transport, what device can position the magnetic heads to the correct track of a hard disk more accurately than a dc stepper motor?

Last Answer : Voice coil servo.

Description : "Autocomplete still not working" entry in Google's troubleshooting is it Mar 4 or 9?

Last Answer : If you read the post, you will see that the original post is from March 4 and a follow-up or second post from another person is dated March 9.

Description : Troubleshooting: PC keeps restarting over and over again. Can you help me get it to stop?

Last Answer : answer:First off, most ASUS laptops have a secured (hidden) recovery partition that lets you do a whole system restore. I don't know if the U56E specifically does, but most recent machines do. When ... t go bad'. Was the laptop dropped or jostled? A flaky electrical connection could be a problem.

Description : Electrical troubleshooting: what's my next step (see details)

Last Answer : You call an electrician.

Description : Troubleshooting: MacBook Pro Screen went black after system update. What can I do?

Last Answer : First, can you plug in an external monitor? If you can then you can see if the computer is still running and doing things. If you can't then maybe you can log in via ssh? If you don ... . If the external monitor stays black then at least your video hardware is toast, and possibly the whole computer.

Description : Help troubleshooting Ubuntu installation?

Last Answer : Did you try a LiveCD/LiveUSB environment before install?

Description : Need help troubleshooting - MacBook Pro startup issue?

Last Answer : Is it one of the MacBooks that has a FireWire 800 port? If so, can you target boot it (hold down the T key at startup) and then plug it into another Mac so you can retrieve your data?

Description : I need help troubleshooting this problem with building a PC?

Last Answer : answer:Are the risers at the back of the motherboard in properly? I forgot to put them in once, and had very similar issues.

Description : Troubleshooting Outlook Express. Help!

Last Answer : Switch to Thunderbird http://www.mozillamessaging.com/en-US/thunderbird/

Description : Port forwarding (linux)... troubleshooting?

Last Answer : Are you sure there’s no software firewall blocking the ports? Sorry, it sounds like you’re not the kind of person who would overlook the obvious, but I had to ask. Do you have logging from the router set up?

Description : Quality css troubleshooting in or around DC? or virtualy?

Last Answer : answer:Based on your previous question I assume that the real problem are your dropdown menus? Have you tried just modifying the code in http://www.alistapart.com/articles/dropdowns (which should work in IE ... it's saved us so much headache on Ask-public and makes our css much more maintainable.

Description : When troubleshooting for connectivity issues Why would it's importance to check the physical condition of the network before running a complex antivirus program?

Last Answer : The problem could be as simple as a frayed wire (apex)

Description : What could be the problem? My Windows 7 system makes it impossible for me to connect to the internet. I create the pppoe connection normally as usual, yet I get this error 651.   

Last Answer : There is a lot of cleverness to read about this error on the net, but it is not up to you, but your service provider, to solve this problem, because this error code indicates that there is a ... 't let yourself be shaken down. They come mainly to Invitel by indicating that everything is fine, etc. 

Description : In the Network plus troubleshooting model what should you always do right after you test the theory?

Last Answer : In the Network plus troubleshooting model what should you alwaysdo right after you test the theory?

Description : What are some common transmission problems and troubleshooting tips?

Last Answer : Well, one of the most common problems tend to be a problem with fluid levels. One such problem could be a break in a seal somewhere or perhaps a faulty solenoid. Locating a leak in a seal isn't ... if you remove the gasket itself, and a replacement isn't so expensive or hard to come by either.

Description : Troubleshooting information for an LG front load washing machine?

Last Answer : If your washing machine recently broke, and your looking for troubleshooting information. I would suggest looking in the owners manual to see if there are any solutions, if not then you might want to call the customer service number or the number of the place where you purchased it.

Description : Troubleshooting Your Samsung T249 Bluetooth?

Last Answer : If you're having a problem with your Samsung T249 and a Bluetooth headset, follow this troubleshooting guide. Ensure that both devices are fully charged and turned on. Turn off any other Bluetooth devices and ... will blink and then go steady to show that it's properly in sync with the Samsung T249.

Description : When troubleshooting an amplifier, you measure an output of 30 volts. If the gain of the amplifier is 2, what must the input voltage be for the amplifier to work properly? A. 32 volts B. 30 volts C. 28 volts D. 15 volts

Last Answer : Answer: D

Description : An open in the armature of a DC motor is suspected, but is not found by visual inspection of the commutator. The next step in troubleshooting this problem is to ________________. A. conduct a ... windings C. conduct an insulation resistance test of the armature D. test the commutator for a ground

Last Answer : Answer: A

Description : When an AC or a DC motor fails to start, the FIRST step in troubleshooting should be to check the ____________. A. motor windings for obvious opens B. motor controller leads for continuity C. fuse or circuit breaker D. motor controller leads for grounds

Last Answer : Answer: C

Description : When troubleshooting a console circuit card suspected of being faulty, the last step would be to _______________. A. check the fuses and voltage levels of all power supplies in the console B. clean dust ... -on types D. substitute a new or repaired spare card and check the operation of the circuit

Last Answer : Answer: D

Description : When troubleshooting a motor controller, all indications are that a relay coil should be energized. If there were no magnetic pull, with rated voltage measured across the coil, the most probable cause ... open C. auxiliary contact in series with the coil is defective D. relay armature is stuck

Last Answer : Answer: A

Description : When troubleshooting a console circuit card suspected of being faulty, first check operating voltages, clean the card and then _________________. A. make sure wired connections and push-on connectors ... circuit traces with an ohmmeter D. measure the gain of each transistor or integrated circuit

Last Answer : Answer: A

Description : When troubleshooting an alkaline storage battery a weak or dead cell is best located by ____________. A. checking the specific gravity of each cell B. visually inspecting each cell's ... testing each cell with a voltmeter D. measuring the electrolyte temperature with an accurate mercury thermometer

Last Answer : Answer: C

Description : When troubleshooting a console circuit card which is suspected of being faulty, the first step would be to _____. A. pull the card and measure the value of all resistors B. check for the ... for burned components D. check for continuity of circuit board traces and then the gain of each transistor

Last Answer : Answer: C

Description : One method of troubleshooting digital circuits in a console is to ___________. A. supply alternate logic levels at the input(s) and test for change of state conditions at the output B. ground all ... output D. vary each input smoothly from 0-10 volts and test for similar variance at the output

Last Answer : Answer: A

Description : When troubleshooting a lead-acid storage battery, a weak or dead cell is best detected by _________________. A. measuring and comparing all cells' specific gravity B. taking an open circuit ... electrolyte levels of each cell D. taking each cell's temperature with a calibrated mercury thermometer

Last Answer : Answer: A

Description : Normally, the FIRST step in troubleshooting a transistor circuit card is to _____________. A. carefully remove the transistors from the card B. give the circuit an initial test with a signal generator C. test for continuity with a low voltage DC supply D. visually inspect the card

Last Answer : Answer: D