Full scale Ammeter reading is 10 mA, Voltage across Ammeter is 100
mV. Then for 100 A measurements the power loss in the circuit is
a) 1 W
b) 10 W
c) 100 W
d) 1000 W

1 Answer

Answer :

Ans: 10 W*

Related questions

Description : You are calibrating a multimeter using internal batteries to supply power for resistance measurements. However, you are unable to adjust the pointer to 'zero' using the adjustment knob. Therefore, you should ... change scales to the R X 100 scale and adjust using the 'zero ohms' adjusting knob

Last Answer : Answer: A

Description : For amplitude measurements, ___ scale is calibrated in either volts per centimeter (V/cm), or millivolts per centimeter (mV/cm)

Last Answer : vertical

Description : When testing for blown fuses in a three-phase supply circuit to a motor, you should first ___________________. A. apply the megger across the tops of the line fuses B. apply an ammeter diagonally across ... of the line fuses D. ensure the circuit is de-energized, and then use a continuity tester

Last Answer : Answer: D

Description : A galvanometer of 65 Ω resistance gives full scale deflection with 4 mA current. In order to convert it into ammeter, the range of 10 A is connected with it, the shunt resistance should be a) 0.1 Ω b) 0.2 Ω c) 0.06 Ω d) 0.03 Ω

Last Answer : d) 0.03 Ω

Description : The full-scale deflection current of an ammeter is 1 mA and its internal resistance is 100Ohm. This is to have full deflection when 100V is measured. What is the value of series resistor to be used?

Last Answer : The full-scale deflection current of an ammeter is 1 mA and its internal resistance is 100Ohm. This is to have full deflection when 100V is measured. 99.99 K ohms is the value of series resistor to be used.

Description :  The full-scale deflection current of an ammeter is 1 mA and its internal resistance is 100Ohm. If this meter is to have full deflection at 5A, what is the value of the shunt resistance to be used?

Last Answer :  The full-scale deflection current of an ammeter is 1 mA and its internal resistance is 100Ohm. If this meter is to have full deflection at 5A, 1/49.99 ohms is the value of the shunt resistance to be used.

Description : An ammeter has a full-scale deflection current of 100mA. If the same ammeter is used to measure a full-scale current of 1.0ampere, what is the value of the shunt resistor in ohms if the voltage across the meter is 9.0 volts?

Last Answer : 10 ohms

Description : In the illustrated motor controller, the motor fails to start. A voltmeter reading between 1 and 6 reads line voltage, while the voltmeter reading between 2 and 6 reads 0 VAC. The problem is __________. EL- ... in the 'M' coil, 'Ma' contact/start switch or overload contacts D. fuse '10a' is blown

Last Answer : Answer: B

Description : If reading the AC voltage from a typical wall outlet, the range switch of the device illustrated should be set to ___________. EL-0047 A. 1,000 V B. 250 V C. R X 10,000 D. 10 ma/amps

Last Answer : Answer: B

Description : A 0-10 mA PMMC ammeter reads 5mA in a circuit; its bottom control spring snaps out suddenly the meter will now read. a) 5mA b) 10mA c) 2.5mA d) 0

Last Answer : Ans: 0

Description :  A 0 -10 mAPMMC ammeter reads 5 mA in a circuit; its bottom control spring snaps out suddenly the meter will now read:- a) 5 mA b) 10 mA c) 2.5 mA d). 0

Last Answer :  A 0 -10 mAPMMC ammeter reads 5 mA in a circuit; its bottom control spring snaps out suddenly the meter will now read:- 0

Description : A galvanometer with 20 ohms coil resistence has a full-scale deflection of 10 mA. A 0.02 ohm is placed across the meter to increase its rating capacity. What is the new full scale current for the meter?

Last Answer : False.

Description : If the motor fails to start and a voltmeter reading between 1 and 6, as illustrated, indicates line voltage, your next step should be to ________. EL-0007 A. replace fuse '10a' B. replace or repair contact 'Ma' C. reset and determine the cause of the overload D. check line voltage between L1 and L3

Last Answer : Answer: C

Description : A 0-10 A ammeter has a guaranteed accuracy of 1% of full scale deflection, the limiting error while reading 2.5 A will be (a) 1% (b) 2% (c) 4% (d) None of these 

Last Answer : A

Description : A multimeter may be damaged by taking a _____________. A. voltage reading while in the ammeter mode B. current reading while in the voltmeter mode C. resistance reading while in the ammeter mode D. resistance reading while in the voltmeter mode

Last Answer : Answer: A

Description : A lead-acid battery is considered fully charged when the ______________. A. electrolyte gasses freely B. battery charger ammeter indicates a positive reading C. terminal voltage reaches a constant value at a ... cells reaches the correct value and no longer increases over a period of 1 to 4 hours

Last Answer : Answer: D

Description : If current of 20 mA is passing through op-amp and voltage drop across series resistor is 10 V then value of resistance is A. 500Ω B. 400Ω C. 300Ω D. 200Ω

Last Answer : 500Ω

Description : The voltage induced across a certain coil is 200 mV. A 1200 resistor is connected to the coil terminals. The induced current will be: A. 1.7 mA B. 16 mA C. 12 mA D. 120 mA

Last Answer : The voltage induced across a certain coil is 200 mV. A 1200 resistor is connected to the coil terminals. The induced current will be: 1.7 mA

Description : Two 100 watt light bulbs are connected in parallel across a 100 volt power supply. The total power developed in the circuit is _______________. A. 200 watts B. 100 watts C. 50 watts D. equal to the product of the amperes times the voltage in each branch

Last Answer : Answer: A

Description : A milliammeter, with a full scale deflection reading of 100 milliamps, is known to have an accuracy of + or - 2%. A meter reading of 10 milliamps would indicate a line current of between _____________. A. 9.8 ... 9.8 and 10.2 milliamperes C. 8.0 and 12.0 milliamperes D. 8.0 and 10.0 milliamperes

Last Answer : Answer: B

Description : When troubleshooting electronic equipment, you should use a high impedance multimeter ________________. A. to prevent excess current flow through the meter that would damage it B. for AC measurements only ... being tested D. so as not to load down the circuit and obtain erroneous voltage readings

Last Answer : Answer: D

Description : When a megohmmeter is being used to test insulation resistance, current leakage along the surface of the insulation is indicated by the megohmmeter's pointer _____________. A. dipping toward ... kicking slightly down scale as voltage is applied D. fluctuating around a constant resistance reading

Last Answer : Answer: C

Description : An ammeter should be used to measure ___________. A. the voltage between two points in a circuit B. circuit continuity C. current flow in a circuit D. total or partial circuit resistance

Last Answer : Answer: C

Description : To properly use a hook-on-type volt/ammeter to check current flow, you must FIRST _____________. A. de-energize the circuit to allow connection of the instrument in series B. hook the jaws ... test leads to the appropriate terminals D. short the test leads and calibrate the instrument to zero

Last Answer : Answer: B

Description : When reading AC current with the multimeter shown in the illustration and you are unsure of the range, the range switch should be set to ___________. EL-0047 A. 10 MA/ 10 AMP with leads in the (-10 A ... leads in the (-COMMON) and (+10 A) jacks D. unable to measure AC current with this multimeter

Last Answer : Answer: D

Description : A moving coil meter has a resistance of 3 Ω and gives full scale deflection with 30 mA. To measure voltage up to 300 V, the external resistance to be connected in series with the instrument is (A) 9997 Ω (B) 10000 Ω (C) 997 Ω (D) 10003 Ω

Last Answer : A moving coil meter has a resistance of 3 Ω and gives full scale deflection with 30 mA. To measure voltage up to 300 V, the external resistance to be connected in series with the instrument is 9997 Ω

Description : If fuse #1 shown in the illustration is defective, a voltage tester connected across points 'C' and 'B' will ____________. EL-0062 A. show a reading of 55 volts B. show full line voltage ... C. give positive indication that fuse #2 is good D. give positive indication that fuse #1 is defective

Last Answer : Answer: D

Description : A three-phase alternator operates at 450 volts with a power factor of 0.8. If the ammeter indicates 250 amperes, what should be the KW meter reading? A. 90.00 KW B. 127.27 KW C. 155.70 KW D. 194.85 KW

Last Answer : Answer: C

Description : A three-phase alternator is operating at 450 volts with the switchboard ammeter indicating 300 amps. The kw meter currently indicates 163.6 KW, with a power factor of 0.7. If the power factor increases to 0.8, the KW meter reading would increase by ___ A. 17.8 KW B. 23.2 KW C. 30.6 KW D. 37.8 KW

Last Answer : Answer: B

Description : Which one of the following is the name of a device used to measure voltage without drawing ANY current from the circuit being measured? Is it: w) a wattmeter x) a galvanometer y) an ammeter z) a potentiometer

Last Answer : ANSWER: Z -- A POTENTIOMETER

Description : A moving coil instrument of resistance 5 Ohm requires a potential difference of 75 mV to give a full scale deflection. The value of shunt resistance needed to give a full scale deflection at 30 A is

Last Answer : A moving coil instrument of resistance 5 Ohm requires a potential difference of 75 mV to give a full scale deflection. The value of shunt resistance needed to give a full scale deflection at 30 A is 2.5 milliOhm

Description : A galvanometer has a coil of resistance `100 Omega` and gives a full-scale deflection for `30 mA` current. If it is to work as a voltmeter of `30 V` r

Last Answer : A galvanometer has a coil of resistance `100 Omega` and gives a full-scale deflection for `30 mA` current. ... Omega` C. `1000 Omega` D. `1800 Omega`

Description : What is the direction of current through the load resistor in the circuit shown in the illustration? EL-0085 A. Always from point 'Z' to the grounded end. B. Always from the grounded end to ... on the instantaneous polarity at point 'W'. D. It cannot be determined without a directional ammeter.

Last Answer : Answer: B

Description : A potentiometer having the potential gradient of `2 mV//cm` is used to measure the difference of potential across a resistance of `10 ohm`. If a lengt

Last Answer : A potentiometer having the potential gradient of `2 mV//cm` is used to measure the difference of potential across a ... `) A. 1 B. 2 C. 5 D. 10

Description : A potentiometer having the potential gradient of `2 mV//cm` is used to measure the difference of potential across a resistance of `10 ohm`. If a lengt

Last Answer : A potentiometer having the potential gradient of `2 mV//cm` is used to measure the difference of potential across a ... `) A. 1 B. 2 C. 5 D. 10

Description : The potential difference across the gap of a spark plug ranges between a) 10-20 mV b) 10-20 V c) 10-20 kV d) 10-20 MV

Last Answer : ans a

Description : An LED is operated on a 12 volt automobile circuit. The voltage drop across the LED is 2 volts and the current must be limited to 50 milliamps to prevent its overheating and destruction. What size resistor must be used? w) 60 ohms x) 100 ohms y) 120 ohms z) 200 ohms

Last Answer : ANSWER: Z -- 200 OHMS

Description : When troubleshooting most electronic circuits, 'loading effect' can be minimized by using a voltmeter with a/an ___________________. A. input impedance much greater than the impedance across which the voltage ... sensitivity of less than 1000 ohms/volt D. sensitivity of more than 1000 volts/ohm

Last Answer : Answer: A

Description : A d.c. shunt motor runs at no load speed of 1140 r.p.m. At full load, armature reaction weakens the main flux by 5% whereas the armature circuit voltage drops by 10%. The motor full load speed in r.p.m. is (A) 1080 (B) 1203 (C) 1000 (D) 1200

Last Answer : (A) 1080

Description : The illustrated circuit is a wheatstone bridge. If the meter 'G' reads 0 with the switch closed then ________. EL-0024 A. the current through R1 - R2 is equal to the current through R3 - Rx B. the voltage ... of E C. the resistance of Rx is equal to the resistance of R2 D. all the above are true

Last Answer : Answer: A

Description : When troubleshooting motor controllers, a shorted relay or contactor coil is often indicated by _______________. A. a resistance reading of 'infinity' on an ohmmeter B. charred insulation and/or a blown ... of the coil's leads to ground D. a higher-than-normal voltage reading across the winding

Last Answer : Answer: B

Description : When there is 12 mA of current through a 1.2 k ohms resistor, the voltage across the resistor is? A.14.4 V B.1.4 V C.100 V D.10 V

Last Answer : When there is 12 mA of current through a 1.2 k ohms resistor, the voltage across the resistor is? A.14.4 V B.1.4 V C.100 V D.10 V

Description : The voltage across a coil, when di/dt = 20 mA/s and L = 8 H, is: A. 16 mV B. 160 mV C. 1.6 mV D. 2.5 mV

Last Answer : The voltage across a coil, when di/dt = 20 mA/s and L = 8 H, is: 160 mV

Description : What is the standard test tone used for audio measurements? A. 100 Hz B. 500 Hz C. 1000 Hz D. 2000 Hz

Last Answer : C. 1000 Hz

Description : In a DC series circuit, all the conductors have the same ____________. A. power expended in them B. voltage drop across them C. resistance to current flow D. current passing through them

Last Answer : Answer: D

Description : In the schematic diagram of the DC compound generator shown in the illustration, the positive ammeter reading is 500 amps and the negative ammeter reading is 475 amps. What is the current flow through the neutral bus? EL-0037 A. 0 amp B. 12.5 amp C. 25 amp D. 975 amp

Last Answer : Answer: C

Description : A switchboard ammeter indicates a reading slightly above 'zero' when the leads are disconnected, this is caused by _____________. A. mechanical misalignment of the meter pointer B. a poor ground for the meter case C. static electricity in the air D. capacitors inside the meter storing charges

Last Answer : Answer: A

Description : In order to take a current reading with a 'clamp-on' ammeter, the instrument's jaws _________________. A. should remain open B. cannot touch the adjacent conductor C. must be fully closed D. will act as a transformer primary

Last Answer : Answer: C

Description : Which of the following statements represents the correct method of connecting the shunt of an ammeter prior to taking a reading? A. In series with the load and in series with the meter movement. B. In ... with the meter movement. D. In parallel with the load and in parallel with the meter movement.

Last Answer : Answer: B