A 0-10 A ammeter has a guaranteed accuracy of 1% of full scale deflection, the limiting error while reading 2.5 A will be (a) 1% (b) 2% (c) 4% (d) None of these 

2 Answers

Answer :

A 0-10A ammeter has a guaranteed accuracy of 1% of full scale deflection, the limiting error while reading 2.5 A will be  4%

error = (10*1)/100 = 0.1

%error = (0.1/2.5)*100 = 4%

Answer :

A

Related questions

Description : A 0 to 300V voltmeter has a guaranteed accuracy of 1% of full scale reading. The voltage measured by the instrument is 83V. The percentage limiting error is

Last Answer : A 0 to 300V voltmeter has a guaranteed accuracy of 1% of full scale reading. The voltage measured by the instrument is 83V. The percentage limiting error is 4.85%.

Description :  In the case of an instrument reading of 8.3 V with a 0 to 150 voltmeter having a guaranteed accuracy of 1% full scale reading, the percentage limiting error is   (A) 1.810% (B) 0.181% (C)12.45% (D) 0.0018%

Last Answer :  In the case of an instrument reading of 8.3 V with a 0 to 150 voltmeter having a guaranteed accuracy of 1% full scale reading, the percentage limiting error is 12.45%

Description : A milliammeter, with a full scale deflection reading of 100 milliamps, is known to have an accuracy of + or - 2%. A meter reading of 10 milliamps would indicate a line current of between _____________. A. 9.8 ... 9.8 and 10.2 milliamperes C. 8.0 and 12.0 milliamperes D. 8.0 and 10.0 milliamperes

Last Answer : Answer: B

Description : A permanent magnet moving coil ammeter has a coil resistance of 99 ohm and Full Scale Deflection (FSD) current of 0.1mA. Shunt resistance is 1 ohm. Current through the meter at 0.5 F.S.D is:

Last Answer : A permanent magnet moving coil ammeter has a coil resistance of 99 ohm and Full Scale Deflection (FSD) current of 0.1mA. Shunt resistance is 1 ohm. Current through the meter at 0.5 F.S.D is: 0.05mA

Description : The full-scale deflection current of an ammeter is 1 mA and its internal resistance is 100Ohm. This is to have full deflection when 100V is measured. What is the value of series resistor to be used?

Last Answer : The full-scale deflection current of an ammeter is 1 mA and its internal resistance is 100Ohm. This is to have full deflection when 100V is measured. 99.99 K ohms is the value of series resistor to be used.

Description :  The full-scale deflection current of an ammeter is 1 mA and its internal resistance is 100Ohm. If this meter is to have full deflection at 5A, what is the value of the shunt resistance to be used?

Last Answer :  The full-scale deflection current of an ammeter is 1 mA and its internal resistance is 100Ohm. If this meter is to have full deflection at 5A, 1/49.99 ohms is the value of the shunt resistance to be used.

Description : Load cells used for the measurement of weight has (A) Compact & rugged construction with an accuracy of 0.1 to 1% (B) No moving parts and incurs negligible deflection under load (C) Provision of thermal compensation and is hermetically sealed (D) All 'a', 'b' & 'c'

Last Answer : (D) All 'a', 'b' & 'c'

Description :  The percentage limiting error, in the case of an instrument reading of 8.3V with a 0 to 150V voltmeter having a guaranteed accuracy of 1% full-scale reading is

Last Answer :  The percentage limiting error, in the case of an instrument reading of 8.3V with a 0 to 150V voltmeter having a guaranteed accuracy of 1% full-scale reading is 18.10%.

Description : A galvanometer of 65 Ω resistance gives full scale deflection with 4 mA current. In order to convert it into ammeter, the range of 10 A is connected with it, the shunt resistance should be a) 0.1 Ω b) 0.2 Ω c) 0.06 Ω d) 0.03 Ω

Last Answer : d) 0.03 Ω

Description : An ammeter has a full-scale deflection current of 100mA. If the same ammeter is used to measure a full-scale current of 1.0ampere, what is the value of the shunt resistor in ohms if the voltage across the meter is 9.0 volts?

Last Answer : 10 ohms

Description : The limiting length of an offset does not depend upon (A) Accuracy of the work (B) Method of setting out perpendiculars (C) Scale of plotting (D) Indefinite features to be surveyed

Last Answer : (D) Indefinite features to be surveyed

Description : A moving coil instrument has a resistance of 10 W and gives full scale deflection when carrying a current of 50 mA. To measure current upto 100 A, we will have to connect • 10 W resistance in series • 10 W resistance in parallel • 10/1999 W resistance in series • 10/1999 W resistance in parallel

Last Answer : A moving coil instrument has a resistance of 10 W and gives full scale deflection when carrying a current of 50 mA. To measure current upto 100 A, we will have to connect 10/1999 W resistance in parallel

Description : Full scale Ammeter reading is 10 mA, Voltage across Ammeter is 100 mV. Then for 100 A measurements the power loss in the circuit is a) 1 W b) 10 W c) 100 W d) 1000 W

Last Answer : Ans: 10 W*

Last Answer : If two meters X and Y requires 40mA and 50mA respectively, to give full scale deflection, then: X is more sensitive

Description : Offsets are measured with an accuracy of 1 in 40. If the point on the paper from both sources of error (due to angular and measurement errors) is not to exceed 0.05 cm on a scale of 1 cm = 20 m, the maximum length of ... should be limited to (A) 14.14 m (B) 28.28 m (C) 200 m (D) None of these

Last Answer : (B) 28.28 m

Description : A digital voltmeter has a read-out range from 0 to 9999 counts. When full scale reading is 9.999 V, the resolution of the instrument will be (a) 100 mV (b) 99 mV (c) 9 mV (d) 1 mV 

Last Answer : d) 1mV 9.999v÷9999v

Description :  Minimum number of bits required to represent maximum value of given analogue signal with 0.1% accuracy is: a. 8 bits b. 9 bits c. 10 bits d. 12 bits

Last Answer : 10

Description : Error in ammeter reading is due to

Last Answer : insertion

Description : An ammeter with an internal resistance of 50 ohm(s) is used to measure a current thorugh a lod resistor Rl = 1 kohm(s). Determine the percentage error of the reading due to ammeter insertion.

Last Answer : 50/(50+1k)*100 = 4.76%

Description : While performing services for their clientsprofessionals have always had a duty to provide a level of care which is a. Reasonable. b. Greater than average. c. Superior. d. Guaranteed to be free from error

Last Answer : Reasonable.

Description : While performing services for their clients professionals have always had a duty to provide a level of care which is a. Reasonable. b. Greater than average. c. Superior. d. Guaranteed to be free from error

Last Answer : Reasonable.

Description : True value has been 50 whereas measured value is 40 then the percentage error in the reading will be ______.  (A) 20% (B) 40% (C) 50% (D) 30%

Last Answer : True value has been 50 whereas measured value is 40 then the percentage error in the reading will be 20%. 

Description : A 150 V moving iron voltmeter of accuracy class 1.0 reads 75 V when used in a circuit under a standard conditions. The maximum possible percentage error in the reading is:

Last Answer : A 150 V moving iron voltmeter of accuracy class 1.0 reads 75 V when used in a circuit under a standard conditions. The maximum possible percentage error in the reading is:  2.0.

Description : A multimeter may be damaged by taking a _____________. A. voltage reading while in the ammeter mode B. current reading while in the voltmeter mode C. resistance reading while in the ammeter mode D. resistance reading while in the voltmeter mode

Last Answer : Answer: A

Description : A 10A DC Ammeter has a resistance of 0.1 Ω is to be extended to 50 A, the required shunt wire is A) Manganin wire of 20 m Ω B) Constantan wire of 20 m Ω C) Manganin wire of 25 m Ω D) Constantan wire of 25 m Ω

Last Answer : A 10A DC Ammeter has a resistance of 0.1 Ω is to be extended to 50 A, the required shunt wire is Manganin wire of 25 m Ω

Description : An ammeter has a current change of 0-5A and its internal resistance is 0.2 ohm. In order to Change the range to 0-25 A, wear need to add a resistance of  A) 0.8 ohm in series with the meter B) ... series with the meter C) 0.04 ohm in parallel with the meter D) 0.05 ohm in parallel with the meter

Last Answer : An ammeter has a current change of 0—5A and its internal resistance is 0.2 ohm. In order to Change the range to 0-25 A, wear need to add a resistance of 0.05 ohm in parallel with the meter

Description : A galvanometer having internal resistance `10 Omega` required `0.01` A for a full scale deflection. To convert this galvanometer to a voltmeter of ful

Last Answer : A galvanometer having internal resistance `10 Omega` required `0.01` A for a full scale deflection. ... Omega` in series D. `12010 Omega` in parallel

Description : A galvanometer with 20 ohms coil resistence has a full-scale deflection of 10 mA. A 0.02 ohm is placed across the meter to increase its rating capacity. What is the new full scale current for the meter?

Last Answer : False.

Last Answer : The repeat accuracy of an instrument can be judged from its standard deviation of error.

Last Answer : The electrostatic instruments can be used without serious loss of accuracy upto 100kHz frequency.

Last Answer : For high accuracy the meter has Hand drawn scale.

Last Answer : In order to achieve high accuracy, the slide wire of a potentiometer should be as long as possible.

Description : Hot wire ammeter is used (a) only for dc circuit (b) only for ac circuit (c) both (a) and (b) (d) Either (a) or (b) 

Last Answer : Either  a  or   b.

Description : The measurement range of an ammeter can be increased by using a:

Last Answer : The measurement range of an ammeter can be increased by using a: low resistance in shunt

Description : Clamp on ammeter is used for measurement of:

Last Answer : Clamp on ammeter is used for measurement of: large alternating currents

Description : Identify the instrument that does not exist (A) Dynamo-meter type ammeter (B) Dynamo-meter type wattmeter (C) Moving-iron voltmeter (D) Moving-iron wattmeter

Last Answer : Identify the instrument that does not exist (A) Dynamo-meter type ammeter (B) Dynamo-meter type wattmeter (C) Moving-iron voltmeter (D) Moving-iron wattmeter

Last Answer : The internal resistance of the ammeter should ideally be Zero.

Last Answer : The internal resistance of an ammeter should be Very small.

Last Answer : A moving iron ammeter may be compensated for frequency errors by shunt capacitance.

Last Answer :  If a DC voltmeter is made from an ammeter having a fed of 100μA then its sensitivity (in KΩ/V) will be 10.

Last Answer : If a voltmeter is connected, like an ammeter in series to the load: Almost no current will flow in the circuit

Last Answer : The function of shunt in an ammeter is to by pass the current.

Last Answer : An ammeter is a secondary instrument.

Last Answer : Ammeter is a current measuring device having low internal resistance so as to direct all the current flowing in the circuit through it. Hence Ammeter is always connected in series with the circuit. If ... If Ammeter is connected in parallel with the supply, then the supply will be a short circuit.

Last Answer : Yes it can...

Description : How do I calculate an allowed deviation of Full Scale based on a known accuracy?

Last Answer : What is the answer ?

Description : In the schematic diagram of the DC compound generator shown in the illustration, the positive ammeter reading is 500 amps and the negative ammeter reading is 475 amps. What is the current flow through the neutral bus? EL-0037 A. 0 amp B. 12.5 amp C. 25 amp D. 975 amp

Last Answer : Answer: C

Description : A three-phase alternator operates at 450 volts with a power factor of 0.8. If the ammeter indicates 250 amperes, what should be the KW meter reading? A. 90.00 KW B. 127.27 KW C. 155.70 KW D. 194.85 KW

Last Answer : Answer: C

Description : A three-phase alternator is operating at 450 volts with the switchboard ammeter indicating 300 amps. The kw meter currently indicates 163.6 KW, with a power factor of 0.7. If the power factor increases to 0.8, the KW meter reading would increase by ___ A. 17.8 KW B. 23.2 KW C. 30.6 KW D. 37.8 KW

Last Answer : Answer: B

Description : While measuring power in a three phase load by two wattmeter method, the reading of two wattmeter are equal and opposite, when (a) load is balanced (b) power factor is unity (c) phase angle is between 60° to 90° (d) the load is purely inductive 

Last Answer :  Option (d)  Load is purely inductive