Which of the following are constant losses in Transformers?

(1) Winding losses

(2) Core losses

(3) Both Winding & core losses

(4) None of these

1 Answer

Answer :

Which of the following are constant losses in Transformers?

(1) Winding losses

(2) Core losses

(3) Both Winding & core losses

(4) None of these

Related questions

Description : Losses which occur in rotating electric machines and do not occur in transformers are?

Last Answer : Friction losses windage losses 

Description : In a given transformer for a given applied voltage, losses which remain constant irrespective of load changes are?

Last Answer : In a given transformer for a given applied voltage, losses which remain constant irrespective of load changes are hysteresis and eddy current losses.

Description : State and justify which of the following two transformers is better:  Transformer A = 4% voltage regulation  Transformer B = 6% voltage regulation

Last Answer : Transformer A with 4% voltage regulation is better.  Justification: Voltage regulation refers to the percentage change in secondary voltage when load is changed from no-load to full-load with primary voltage ... 4% voltage regulation, which is less as compared to 6% of transformer B, it is better.

Description : Which of the following company is associated with manufacture of high capacity transformers in India? A) M/S National Thermal Power Corporation Limited B) M/S Bharat Heavy Electricals Limited C) M/S Heavy Engineering Corporation Limited D) M/S Electricity Authority of India

Last Answer : Which of the following company is associated with manufacture of high capacity transformers in India? A) M/S National Thermal Power Corporation Limited B) M/S Bharat Heavy Electricals Limited C) M/S Heavy Engineering Corporation Limited D) M/S Electricity Authority of India

Description :  Impulse testing of transformers is done to determine the ability of: A) bushings to withstand vibrations B) insulation to withstand transient voltages C) windings to withstand voltage fluctuations D) all of the above

Last Answer :  Impulse testing of transformers is done to determine the ability of: insulation to withstand transient voltages

Description : Instruments transformers are used on a.c. circuits for extending the range of (a) ammeters (b) voltmeters (c) wattmeters (d) all of these 

Last Answer : is the load PF is 0.866 then the average PF of the VV bank is

Description : The potential transformers Nominal Ratio is defined as the ratio of:

Last Answer : The potential transformers Nominal Ratio is defined as the ratio of: rated primary winding voltage and rated secondary winding voltage

Description : Two transformers with identical voltage ratings are working in parallel to supply common load. The percentage impedance of one transformer is higher compared to that of other. The load sharing ... respective impedance (4) Depend on the resistance to leakage reactance ratio of each transformer

Last Answer : Two transformers with identical voltage ratings are working in parallel to supply common load. The percentage impedance of one transformer is higher compared to that of other. The load sharing between the two transformer will: Be inversely proportional of their respective impedance

Description : Two transformers are to be operated in parallel such that they share load in proportion to their kVA ratings. The rating of the first transformer is 500 kVA ratings. The rating of the first transformer is 500 kVA and its pu ... its pu leakage impedance is  (A) 0.20 (B) 0.10 (C) 0.05 (D) 0.025

Last Answer : Two transformers are to be operated in parallel such that they share load in proportion to their kVA ratings. The rating of the first transformer is 500 kVA ratings. The rating of the first transformer is ... .05 pu. If the rating of second transformer is 250 kVA, its pu leakage impedance is 0.10

Description : In transformers, which ofthe following statements is valid?  A) In an open circuit test, copper losses are obtained while in short circuit test, core losses are obtained B) In an open circuit test, ... drawn at zero power factor D) In an open circuit test, current is drawn at low power factor

Last Answer : In transformers, which ofthe following statements is valid?  A) In an open circuit test, copper losses are obtained while in short circuit test, core losses are obtained B) In an open circuit test, ... drawn at zero power factor D) In an open circuit test, current is drawn at low power factor

Description : Two transformers operating in parallel will share the load depending upon their

Last Answer : Two transformers operating in parallel will share the load depending upon their Per unit impedance

Last Answer : Natural oil cooling is used for transformers up to a rating of 3000 kVA.

Description : If the percentage impedances of the two transformers working in parallel are different, then?

Last Answer : If the percentage impedances of the two transformers working in parallel are different, then parallel operation will still be possible, but the power factors at which the two transformers operate will be different from the power factor of the common load.

Last Answer : Distribution transformers are generally designed for maximum efficiency around 50% load.

Last Answer : Star/star transformers work satisfactorily when load is balanced .

Last Answer : Power transformers are generally designed to have maximum efficiency around near full-load.

Description : Two transformers are connected in parallel. These transformers do not have equal percentage impedance. This is likely to result in?

Last Answer : Two transformers are connected in parallel. These transformers do not have equal percentage impedance. This is likely to result in loading of the transformers not in proportion to their kVA ratings.

Last Answer : Short circuit test on transformers is conducted to determine copper losses.

Last Answer : Necessary conditions required to be satisfied in order to ensure successful parallel operation of single phase transformers:  1. Only transformers having the same phase displacement between primary and secondary ... . 7. The phase sequence must be followed strictly on HV and LV side connection.

Last Answer : Natural air cooling is generally restricted for transformers up to 1.5 MVA .

Description : The efficiency of two identical transformers under load conditions can be determined by?

Last Answer : The efficiency of two identical transformers under load conditions can be determined by back-to-back test.

Description : The efficiencies of transformers compared with that of electric motors of the same power are?

Last Answer : Transformers have high efficiency than the same ratted motors

Description : A 500 kVA, 3-phase transformer has iron losses of 300 W and full load copper losses of 600 W. The percentage load at which the transformer is expected to have maximum efficiency is  (A) 50.0% (B) 70.7% (C) 141.4% (D) 200.0%

Last Answer : A 500 kVA, 3-phase transformer has iron losses of 300 W and full load copper losses of 600 W. The percentage load at which the transformer is expected to have maximum efficiency is 70.7%

Description : Which losses in a transformer varies significantly with load  a. Hysteresis losses b. Eddy current losses c. Copper losses d. Core losses 

Last Answer : Which losses in a transformer varies significantly with load Copper losses

Description : The hysteresis and eddy current losses of a single phase transformer working on 200 V, 50 Hz supply are Ph and Pe respectively. The percentage decrease in these when operated on a 160 V, 40 Hz supply are   (a) 32, 36 (b) 20, 36 (c) 25, 50 (d) 40, 80 

Last Answer : The hysteresis and eddy current losses of a single phase transformer working on 200 V, 50 Hz supply are Ph and Pe respectively. The percentage decrease in these when operated on a 160 V, 40 Hz supply are 20, 36

Description : During short circuit test iron losses are negligible because?

Last Answer : During short circuit test iron losses are negligible because the voltage applied on primary side is low.

Description : Reduction in core losses and increase in permeability are obtained with transformer employing?

Last Answer : Reduction in core losses and increase in permeability are obtained with transformer employing core built-up of laminations of cold rolled grain oriented steel.

Description : Auto-transformer makes effective saving on copper and copper losses, when its transformation ratio is?

Last Answer : Auto-transformer makes effective saving on copper and copper losses, when its transformation ratio is approximately equal to 1.

Description : What are the losses of transformers ?

Last Answer : 1. Copper loss 2. Core loss

Description : [75] Two transformers are connected in parallel. These transformers do not have equal percentage impedance which results A. Short-circuiting of the secondaries B. Power factor of one of the ... have negligible core losses D. Loading of the transformers not in proportion to their kVA ratings.

Last Answer : D. Loading of the transformers not in proportion to their kVA ratings

Description : 1 Sumpner's test is conducted on transformers to find A. Temperature B. Stray losses C. All-day efficiency D. None of the above

Last Answer : A. Temperature

Description : The friction losses in Real Transformers are :  (A) 0% (B) 5% (C) 25% (D) 50%

Last Answer : A

Description : Distribution transformers have core losses:  (1) More than full load copper losses (2) Equal to full load copper losses (3) Less than full load copper losses (4) W Negligible compared to full load copper losses

Last Answer : Distribution transformers have core losses:  Less than full load copper losses.

Description : For a constant load current, transformer maximum efficiency occurs at   (a) any power factor (b) zero power factor leading (c) zero power factor lagging (d) unity power factor 

Last Answer : For a constant load current, transformer maximum efficiency occurs at unity power factor 

Last Answer : The power transformer is a constant main flux device.

Description : In an actual transformer the iron loss remains practically constant from no load to full load because?

Last Answer : In an actual transformer the iron loss remains practically constant from no load to full load because core flux remains practically constant.

Description : For a transformer, operating at constant load current, maximum efficiency will occur at?

Last Answer : For a transformer, operating at constant load current, maximum efficiency will occur at unity power factor.

Description : In the illustrated electronic governor, the circuit card connected to the potential and current transformers is for ________. EL-0046 A. increasing the signal strength to the governor to ... from motorization D. conditioning the load through the use of a magnetic amplifier current transformer

Last Answer : Answer: A

Description : The rotor slots of a repulsion-type motor are generally skewed (placed nonparallel to the rotor axis) to _________. A. produce a constant starting torque B. permit a greater air gap with the starter C. permit a smaller air gap with the starter D. reduce eddy current losses

Last Answer : Answer: A

Description : Why are iron losses considered as constant losses in transformer?

Last Answer : Iron losses depend on supply frequency and flux density in the core. For all normal operations, the frequency of flux reversals which is same as supply frequency is constant and the value of flux density ... . Hence iron losses remain constant under all load conditions. i-e from no-load to full-load

Description : To pump water from a water reservoir 3 m deep and maximum water level at 135 m, a pump is  installed to lift water up to R.L. 175 m at a constant rate of 36,00,000 litres per hour. If the length  of the ... the water horse power of the pump is  (A) 400  (B) 450  (C) 500 (D) 600

Last Answer : (D) 600

Description : [53] The iron loss of the transformer is negligible during short circuit test because A. The entire input is just sufficient to meet Cu losses only B. Flux produced is a small fraction of the normal flux C. Iron core becomes fully saturated D. Supply frequency is held constant

Last Answer : B. Flux produced is a small fraction of the normal flux

Description : Explain direct loading test on single phase transformer with neat circuit diagram. 

Last Answer : Direct loading test on single phase transformer with neat circuit diagram:   Direct loading test on transformer is carried out to calculate the losses, efficiency and voltage regulation of the ... voltage.  Efficiency and regulation can be calculated by using following formulae:   

Description : Explain the effect of Harmonics on the Transformer.

Last Answer : Effect of Harmonics on the Transformer:  1. Core loss: Harmonic voltage increases the hysteresis and eddy current losses in the lamination. The amount of the core loss depends on ... small core vibrations.  5. Saturation problem: Sometimes additional harmonic voltage causes core saturation.

Description : Explain with the neat circuit diagram only the scott connection scheme for conversion of three phase supply to two phase supply. Name one application of the same.

Last Answer : Three-phase to Two-phase Transformation (Scott Connection of Transformers): Working: i) Scott connection can be used for three-phase to two-phase conversion using two single-phase transformers ... a 3-phase system with a two-phase system with the flow of power in either direction. 

Description : List two special feature of welding transformer.

Last Answer : Special features of welding transformer: i) It is a step down transformer that reduces the source voltage to a voltage desired according to the demands of the welding process. ii) Having large primary turns and less ... V ii) Secondary voltage - 40 to 60 V iii) Secondary current - 200 to 600 A

Description : State two applications of isolation transformer

Last Answer : Applications of isolation transformer: i) Isolates the load equipment from supply ground: ii) Reduction of voltage spikes iii) It acts as a decoupling device. iv) Protects loads from harmonic distortion.

Description : State why a transformer always have an efficiency of more than 90%.

Last Answer : As transformer is static device with no moving parts, the losses due to friction & windage are completely absent. Hence transformer has efficiency of more than 90%.

Description : Equivalent circuit of transformer

Last Answer : Equivalent Circuit Diagram of Transformer Referred to Primary: V1 -Primary Input voltage I1 - Input Current I0- Exciting current/ No load current Im- Magnetizing component ... equivalent of secondary terminal voltage ZL- Load impedance ZL ′- Primary equivalent of load impedance