A gas turbine power plant is best suited for (a) base load (b) peak load (c) emergency purpose (d) None of the above

1 Answer

Answer :

A gas turbine power plant is best suited for peak load operation

Related questions

Description : List the types of turbine used in hydro power plant.  

Last Answer : Following types of turbine used in hydro power plant:  1.Pelton wheel 2.Francis Turbine 3.Kaplan Turbine 4.Propeller Turbine 

Description : A gas turbine works on: A) Carnot cycle B) Brayton cycle C) Dual cycle D) Rankine cycle

Last Answer : A gas turbine works on: Brayton cycle

Description : Reheating in a gas turbine (1) increases the compressor work (2) decreases the compressor work (3) increases the turbine work (4) decreases the turbine work

Last Answer : Reheating in a gas turbine increases the turbine work

Description : The use of regenerator in a gas turbine cycle  (1) increases efficiency but has no effect on output (2) increases output but has no effect on efficiency (3) increases both efficiency and output (4) increases efficiency but decreases output

Last Answer : The use of regenerator in a gas turbine cycle increases efficiency but has no effect on output

Description : Which source is best suited for electricity generation in a remote rural area? (A) Nuclear Power plant (B) Solar farm (C) Wind farm (D) Biomass

Last Answer : Which source is best suited for electricity generation in a remote rural area? (A) Nuclear Power plant (B) Solar farm (C) Wind farm (D) Biomass

Description : With a neat diagram explain pelton wheel turbine.

Last Answer : Diagram of Pelton Wheel:-  Construction of Pelton Wheel Turbine:  1. Runner with Bucket: The runner of a pelton turbine consists of a number of double cupped buckets surrounded ... necessary to avoid accidents, splashing race and to support the housing for the bearing and the nozzle. 

Description : For high head and low discharge, the water turbine used is

Last Answer : For high head and low discharge, the water turbine used is Pelton wheel

Description : In steam turbine terminology, diaphragm refers to  (1) separating wall between rotors carrying nozzles (2) the ring of guide blades between rotors (3) a partition between low and high pressure sides (4) the flange connecting the turbine exit to the condenser

Last Answer : In steam turbine terminology, diaphragm refers to separating wall between rotors carrying nozzles 

Description : Which power plant has minimum operating cost? a) Hydroelectric power plant b) Thermal power plant c) Nuclear power plant d) Gas Turbine Power Plant Ans: A 42. Which of the following have ... a) Hydroelectric power plant b) Thermal power plant c) Nuclear power plant d) Solar electric power plant

Last Answer : Ans: B

Description : Why gas turbine power plant needs efficient compressor ?

Last Answer : Because a large portion of turbine work is eaten away by compressor and its inefficiency will affect net power output and cost of generation.

Description : What is the purpose of intercooler in gas turbine power plant?

Last Answer : Since the power required to compress the air is less in isothermal process it is required to maintain the, temperature of air constant as far as possible. Hence the air leaving the L.P. compressor is cooled by intercooler and then passed to the H.P compressor.

Description : What Is The Purpose Of Inter Cooler In Gas Turbine Power Plant?

Last Answer : Since the power required compressing the air is less in isothermal process it is required to maintain the, temperature of air constant as far as possible. Hence the air leaving the L.P. compressor is cooled by intercooler and then passed to the H.P compressor.

Description : Draw and label the gas turbine power plant

Last Answer : OR

Description : What are the criteria for selection of site for hydroelectric power plant?

Last Answer : Following Factors to be kept while site selecting for Hydro power plant:  1. It should be located where high rain fall occurs. 2. A large catchments area must be available to store water. 3. It ... 12. Cost of land should be less. 13. Skilled and unskilled man power should be available nearby.

Description : Explain the function of different parts of a typical nuclear power plant with neat sketch. 

Last Answer : Functions of each part of Nuclear power plant:-  1) Nuclear Reactor: In nuclear reactor the fuel rod of U235 is placed through which tremendous amount of heat energy is ... is mechanically coupled with steam turbine. 8) Alternator: It converts mechanical energy into electrical energy.

Description : With a neat diagram explain pumped storage hydro power plant. 

Last Answer : Diagram of pumped storage hydro power plant: Explanation: In this power plant, generator is so designed that it Converts mechanical power into electrical power and also works as a ... helps in reducing a reserve capacity of PP as it provides additional power during peak load period. 

Description : Draw a layout of a thermo-chemical based power plant. 

Last Answer : Layout of a thermo-chemical based power plant:  In this process dry biomass fuels converted to produce gas ,liquid fuels or oil by thermo chemical conversion Thermo-Chemical conversion are of following ways:- 1. Direct combustion 2. Gasification 3. Pyrolysis

Description : With a neat diagram explain solar photovoltaic power plant. 

Last Answer : Diagram of solar photovoltaic power plant :  Explanation:  Solar power plant consists of following components:  1. Photovoltaic cell panel: Its function is to convert sunrays directly into DC ... .  5. Step-up transformer: It step-up input voltage to utilization voltage e.g. 230V

Description : Explain the choice of size and number of generator units in a power plant. 

Last Answer : Selection of Size and Number of Generating Units:  1. The size/rating and number of generating units in such way that they approximately match with the load curve/load duration curve as ... power plant is connected to grid system then generating unit of higher capacity can be installed.

Last Answer : Because of following advantages concentrating type collector are used in solar power plant: -  1. Temperature: Temperature obtained is high because absorber area is less and collector/reflector area ... results: As tracking system is used better results are obtain than flat type collector.

Last Answer : Explanation of 'Nuclear shielding' in Nuclear Power Plant:  Shielding is provided to absorb alpha, beta particles and gama rays which are produced during nuclear chain reaction (fission process) The ... of Water or concerate wall are provided all around the reactor vessel for stopping neutrons.  

Description : Explain thermal power plant with diagram.

Last Answer : Thermal power plant  Thermal power plants (referred to as thermal power plants ) can generate large amounts of electricity continuously. In many countries, most of the electricity is provided by thermal ... Creative Commons Attribution-Share Alike : https://zh.wikipedia.org/zh-hans/火力發電廠

Description : The overall efficiency of Thermal Power Plant is equal to _______________ .  (A) Regenerative Cycle Efficiency (B) Renkine Cycle Efficiency (C) Carnot cycle efficiency (D) None of the above

Last Answer : The overall efficiency of Thermal Power Plant is equal to Regenerative Cycle Efficiency. 

Description : In a thermal power plant, ash is collected in

Last Answer : In a thermal power plant, ash is collected in hoppers or bunkers

Description : The rankine cycle efficiency of steam power plant is  (1) 60-80% (3) 30-45% (2) 45-80% (4) 20-30%

Last Answer : The rankine cycle efficiency of steam power plant is 30-45%

Last Answer : In a power plant if the maximum demand on the plant is equal to the plant capacity, then plant reserve capacity will be zero.

Last Answer : Maximum demand on a power plant is the greatest of all "short time interval averaged" demand during a period.

Last Answer : Annual operating expenditure of a power plant consists of fixed charges, semi-fixed charges, running charges.

Description : What is the largest power plant in the world?

Last Answer : japam

Description : What is the most common type of power plant?

Last Answer : Hydroelectric  power  plant.

Description : Why thermal efficiency of I.C. engines is more than that of gas turbine plant ?

Last Answer : In I.C. engine maximum temperature attained is higher than in gas turbine.

Description : How can I run a gas turbine power generator efficiently?

Last Answer : www.muellerenvironmental.com/documents/GER3567H.pdf discusses many factors affecting gas turbine efficiency. It specifically addresses GE turbines, but the factors discussed are relevant to all gas turbine power generators.

Description : Gas cooling as compared to water cooling of nuclear reactors (A) Cannot attain a high temperature (B) Is more efficient as gas has a higher specific heat (C) Can produce only saturated steam for feeding to power turbine (D) None of these

Last Answer : (D) None of these

Description : Which of the following is considered a renewable resource? w) Coal fired power plant x) Hydroelectric dam y) Combustion turbine facility z) Nuclear fission power plant 

Last Answer : ANSWER: X -- HYDROELECTRIC DAM

Description : Draw and explain fixed dome type biogas plant. 

Last Answer : Diagram of fixed dome type biogas plant: Explanation of layout of biogas plant by the method of fermentation conversion  1. Foundation : Biomass plant consists of pit excavated to desire ... the slurry from the top of the dome with the help of stirrer which is at digester chamber.

Description : Compare base load plant with peak load plant. 

Last Answer : Sr.No. Points Base load plant Peak load plant  1 Definition The power plant which supplies base load of load curve is known as base load plant The power ... power station   Small capacity storage hydro, pumped storage hydro, gas, diesel power station. 

Description : Which of the following components is not a part of hydro-electric plant ? (a) Penstock (b) Spillway (c) Surge tank (d) Economiser 

Last Answer : Economiser

Last Answer : Nuclear power plant is invariably used as base load plant.

Last Answer : Hydroelectric power plant is expected to have the longest life.

Last Answer : A low utilization factor for a plant indicates that plant is used for stand by purpose.

Last Answer : Peak load plant can never have 100 percent load factor.

Description : List any two Thermal Power Station in Maharashtra with their installed capacity. 

Last Answer :  Thermal Power Station in Maharashtra with their installed capacity :

Description : With a neat diagram explain medium head hydro-electric power plants. 

Last Answer : Diagram of medium head hydro-electric power plants:  Explanation:- If head of water is between 30 and 100 m, the plant is called a medium-head plant. Potential energy of ... Francis turbines are normally used. Alternator required in these plants is of low speed and large in diameter. 

Last Answer : Diagram explain solar power tower : All concentrating solar thermal power (STP) basic elements: Concentrator Receiver Transport-storage (a portion of the thermal energy ... with alternator which converts mechanical power to electrical energy Exhaust steam is condensate in condenser

Description :  Overall thermal efficiency of a steam power station in India is in the range: A) 18-24 percent B) 30-40 percent C) 44-62 percent D) 68-79 percent

Last Answer :  Overall thermal efficiency of a steam power station in India is in the range: 30-40 percent 

Description : The type of alternator used in hydroelectric power stations is

Last Answer : The type of alternator used in hydroelectric power stations is salient pole alternator

Description : In a power station, the cost of generation of power reduces when (A) diversity factor alone increases (B) both diversity factor and load factor increase. (C) load factor alone increases. (D) both diversity factor and load factor decrease,

Last Answer : In a power station, the cost of generation of power reduces when both diversity factor and load factor increase.

Description : Power generation cost reduces as (A) Diversity factor increases and load factor decreases. (B) Diversity factor decreases and load factor increases. (C) Both diversity factor and load factor increase. (D) Both diversity factor and load factor decrease

Last Answer : Power generation cost reduces as Both diversity factor and load factor increase.

Description : In hydroelectric power plants  (1) both operating and initial cost are high (2) both operating and initial cost are low (3) operating cost is low and initial cost is high (4) operating cost is high and initial cost is low

Last Answer : In hydroelectric power plants operating cost is low and initial cost is high