In case of parallel flow heat exchanger, the lowest temperature
theoretically attainable by the hot fluid is __________ the outlet
temperature of the cold fluid.
(A) Equal to
(B) More than
(C) Less than
(D) Either more or less than (depending upon the fluid)

1 Answer

Answer :

(A) Equal to

Related questions

Description : Pick out the wrong statement. (A) The controlling resistance in case of heating of air by condensing steam is in the air film (B) The log mean temperature difference (LMTD) for ... a pure fluid at a given pressure from liquid to vapor or vice-versa occurs at saturation temperature

Last Answer : (C) In case of a 1 - 2 shell and tube heat exchanger, the LMTD correction factor value increases sharply, when a temperature cross occurs

Description : LMTD for counter-flow and parallel flow heat exchanger will be the same, when the (A) Cold fluid is heated to a certain temperature by condensing steam (isothermal fluid) (B) Outlet temperature of ... temperature of hot fluid is less than the outlet temperature of the cold fluid (D) None of these

Last Answer : (A) Cold fluid is heated to a certain temperature by condensing steam (isothermal fluid)

Description : In a parallel flow heat exchanger, if the outlet temperature of hot and cold fluids are the same, then the log mean temperature difference (LMTD) is (A) Minimum (B) Maximum (C) Zero (D) Infinity

Last Answer : (C) Zero

Description : In a 1-1 concurrent heat exchanger, if the tube side fluid outlet temperature is equal to the shell side fluid outlet temperature, then the LMTD is (A) ∞ (B) 0 ... temperature (D) Equal to the difference between hot fluid inlet temperature and cold fluid outlet temperature

Last Answer : (B) 0

Description : In a counter flow heat exchanger, hot fluid enters at 170°C & leaves at 150°C, while the cold fluid enters at 50°C & leaves at 70°C. The arithmetic mean temperature difference in this case is __________ °C. (A) 20 (B) 60 (C) 120 (D) ∞

Last Answer : (D) ∞

Description : Parallel straight line pattern of temperature distribution for both hot and cold fluids is observed in case of heat exchanger of the type (A) Parallel flow with equal heat capacities (B) Counter ... (C) Counter flow with unequal heat capacities (D) Parallel flow with unequal heat capacities

Last Answer : (B) Counter flow with equal heat capacities

Description : For the same heat load and mass flow rate in the tube side of a shell and tube heat exchanger, one may use multipass on the tube side, because it (A) Decreases the pressure drop (B) ... the outlet temperature of cooling medium (C) Increases the overall heat transfer coefficient (D) None of these

Last Answer : (C) Increases the overall heat transfer coefficient

Description : In an extended surface heat exchanger, fluid having lower co-efficient (A) Flows through the tube (B) Flows outside the tubes (C) Can flow either inside or outside the tubes (D) Should not be used as it gives very high pressure drop

Last Answer : (B) Flows outside the tubes

Description : In a heat exchanger, the rate of heat transfer from the hot fluid to the cold fluid (A) Varies directly as the area and the LMTD (B) Directly proportional to LMTD and inversely proportional to the area (C) Varies as square of the area (D) None of these

Last Answer : (A) Varies directly as the area and the LMTD

Description : If the baffle spacing in a shell and tube heat exchanger increases, then the Reynolds number of the shell side fluid (A) Remains unchanged (B) Increases (C) Increases or decreases depending on number of shell passes (D) Decreases

Last Answer : (D) Decreases

Description : Pick out the wrong statement. (A) Superheated steam is preferably not used for process heating because of its low heat transfer film co-efficient (B) In a shell and tube heat exchanger ... surface heat exchangers, when the direction of fluid flow is parallel to the axis of the tube

Last Answer : (C) S.I. unit of fouling factor is Watt/m2 .°K

Description : In a heat exchanger with steam outside the tubes, a liquid gets heated to 45°C, when its flow velocity in the tubes is 2 m/s. If the flow velocity is reduced to 1 m/s, other things remaining ... than 45°C (B) More than 45°C (C) Equal to 45°C (D) Initially decreases and remains constant thereafter

Last Answer : (B) More than 45°C

Description : The outlet temperature of cooling water in a heat exchanger is generally not allowed to exceed above 50°C in industrial practice mainly to avoid (A) Its evaporation loss (B) Excessive corrosion (C) Uneconomic LMTD (D) Decrease in heat exchanger efficiency

Last Answer : (B) Excessive corrosion

Description : Pick out the wrong statement. (A) Heat transfer by radiation cannot occur across an absolute volume (B) In case of a shell and tube heat exchanger, the pressure drop through the shell is ... The amount of heat involved in the condensation or vaporisation of 1 kg of a fluid is the same

Last Answer : (A) Heat transfer by radiation cannot occur across an absolute volume

Description : In case of a multipass shell and tube heat exchanger, the temperature drop in the fluid (A) Is inversely proportional to the resistance across which the drop occurs (B) And the wall are proportional to individual resistances (C) And the wall is not related (D) None of these

Last Answer : (B) And the wall are proportional to individual resistances

Description : Hot water (0.01 m3 /min) enters the tube side of a counter current shell and tube heat exchanger at 80°C and leaves at 50°C. Cold oil (0.05 m3 /min) of density 800 kg/m3 and specific heat of ... mean temperature difference in °C is approximately (A) 32 (B) 37 (C) 45 (D) 50

Last Answer : (A) 32

Description : __________ heat exchanger is the most suitable, when the temperature of shell side fluid is much higher than that of tube side. (A) Single pass, fixed tube sheet (B) U-tube (C) Three pass, fixed tube sheet (D) None of these

Last Answer : (B) U-tube

Description : In a liquid-liquid heat exchanger, for the same process temperature, the ratio of the LMTD in parallel flow to the LMTD in counter flow is always (A) < 1 (B) > 1 (C) 1 (D) ∞

Last Answer : (A) < 1

Description : Shell side pressure drop in a shell and tube heat exchanger does not depend upon the (A) Baffle spacing & shell diameter (B) Tube diameter & pitch (C) Viscosity, density & mass velocity of shell side fluid (D) None of these

Last Answer : (D) None of these

Description : The inside heat transfer co-efficient in case of turbulent flow of liquid in the tube side in a 1-2 shell and tube heat exchanger is increased by __________ times, when the number of tube passes is increased to 8. (A) 2 0.8 (B) 4 0.8 (C) 4 0.4 (D) 2 0.4

Last Answer : (B) 4 0.8

Description : LMTD for evaporators & condensers for a given terminal parameters & set of conditions for counter-flow is equal to that for parallel flow. In such heat exchangers, with one of the fluids condensing or evaporating, the surface ... Parallel (B) Mixed (C) Counter flow (D) Same in either 'a', b' or 'c'

Last Answer : (D) Same in either 'a', b' or 'c'

Description : Vibrations in the tubes of a shell and tube heat exchanger is induced due to the (A) Flow of fluid on the tube and shell sides (B) Oscillations in the flow of shell/tube sides fluid (C) Vibrations ... piping and/or supports due to external reasons (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : A fluid is flowing inside the inner tube of a double pipe heat exchanger with diameter 'd'. For a fixed mass flow rate, the tube side heat transfer co￾efficient for turbulent flow conditions is proportional to (A) d 0.8 (B) d -0.2 (C) d -1 (D) d -1.8

Last Answer : (B) d -0.2

Description : Use of transverse baffles in a shell and tube heat exchanger is done to increase the (A) Rate of heat transfer (B) Flow velocity (C) Turbulence of shell side fluid (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : In a co-current double pipe heat exchanger used for condensing saturated steam over the inner tube, if the entrance and exit conditions of the coolant are interchanged, then the rate of condensation ... Decrease (C) Remain unchanged (D) Either increase or decrease; depends on the coolant flow rate

Last Answer : (C) Remain unchanged

Description : Pick out the wrong statement. (A) Theoretical flame temperature is the temperature attained by the products of combustion, when the fuel is burned without loss or gain of heat (B) ... flame temperature (D) Adiabatic flame temperatures of actual combustions are always less than the maximum values

Last Answer : (C) Burning the fuel with excess pure oxygen results in maximum theoretical flame temperature

Description : A 2-4 heat exchanger involves (A) Only counter-flow of fluids (B) Only parallel-flow of fluids (C) Both counter and parallel-flow of the fluids (D) Smaller pressure drop compared to 1-2 exchanger

Last Answer : (C) Both counter and parallel-flow of the fluids

Description : Baffles in the shell side of a shell and tube heat exchanger (A) Increase the cross-section of the shell side liquid (B) Force the liquid to flow parallel to the bank (C) Increase the shell side heat transfer co-efficient (D) Decrease the shell side heat transfer co-efficient

Last Answer : (C) Increase the shell side heat transfer co-efficient

Description : A process stream of dilute aqueous solution flowing at the rate of10 Kg.s -1 is to be heated. Steam condensate at 95°C is available for heating purpose, also at a rate of 10 Kg.s -1 . A 1 ... side (C) Parallel flow with process stream on shell side (D) Parallel flow with process stream on tube side

Last Answer : (A) Counter flow with process stream on shell side

Description : Though, theoretically the adsorption & desorption isotherms is expected to coincide but sometimes at least a part of the isotherms does not coincide and this phenomenon is known as adsorption hysteresis. In such ... (B) Higher than (C) Same as (D) Either same or higher than

Last Answer : (A) Lower than

Description : In a shell and tube heat exchanger, putting a longitudinal baffle across the shell, forces the shell side fluid to pass __________ through the heat exchanger. (A) Once (B) Twice (C) Thrice (D) Four times

Last Answer : (B) Twice

Description : case of condensers & evaporators operating under given terminal conditions, LMTD (logarithmic mean temperature difference) for counter flow as compared to that for parallel flow is (A) More (B) Less (C) Equal (D) Much more

Last Answer : Option C

Description : Select the wrong statement pertaining to flow of an incompressible fluid through a Venturimeter. (A) For frictionless flow, the fluid pressure entering the venturi meter will be exactly equal ... than an orificemeter (D) Venturimeter incurs less power loss compared to an equivalent orificemeter

Last Answer : (C) Venturimeter occupies less space than an orificemeter

Description : Minimum temperature upto which water can be theoretically cooled down in the cooling tower by evaporative cooling is equal to the __________ temperature of air. (A) Wet bulb (B) Dry bulb (C) Saturation (D) Dew point

Last Answer : Option A

Description : For motion of spherical particles in a stationary fluid, the drag co￾efficient in hindered settling compared to that in free settling is (A) More (B) Less (C) Equal (D) More or less, depending on the type of particle

Last Answer : (A) More

Description : Lowering of condenser temperature (keeping the evaporator temperature constant) in case of vapour compression refrigeration system results in (A) Increased COP (B) Same COP (C) Decreased COP (D) Increased or decreased COP; depending upon the type of refrigerant

Last Answer : (A) Increased COP

Description : Absolute zero temperature signifies the (A) Minimum temperature attainable (B) Temperature of the heat reservoir to which a Carnot engine rejects all the heat that is taken in (C) Temperature of the heat reservoir to which a Carnot engine rejects no heat (D) None of these

Last Answer : (C) Temperature of the heat reservoir to which a Carnot engine rejects no heat

Description : Pick out the wrong statement. (A) The form drag is dependent upon the occurrence of a wake (B) The shear stress at any given cross-section of a pipe for steady flow (either laminar or turbulent ... of viscosity (D) Existence of the boundary layer in fluid flow is because of viscosity of the fluid

Last Answer : (C) An ideal fluid is the one, which has negligible surface tension and obeys the Newton's law of viscosity

Description : A solid material shows case hardening properties while drying. Which of the following should be controlled to control the drying process? (A) Flow rate of inlet air (B) Relative humidity of outlet air (C) Humidity of inlet air (D) Temperature of the solid

Last Answer : (D) Temperature of the solid

Description : For a given fluid, as the pipe diameter increases, the pumping cost (A) Decreases (B) Increases (C) Remains the same (D) May increase or decrease, depending upon whether the fluid is Newtonian or non-Newtonian

Last Answer : (A) Decreases

Description : While starting a centrifugal pump, its delivery valve should be kept (A) Opened (B) Closed (C) Either opened or closed; it does not make any difference (D) Either opened or closed; depending on the fluid viscosity

Last Answer : (B) Closed

Description : Economic order quantity is that quantity at which cost of holding and carrying inventory is: (a) Maximum and equal (b) Minimum and equal (c) It can be maximum or minimum depending upon case to case. (d) Minimum and unequal

Last Answer : (b) Minimum and equal

Description : In case of a multipass shell and tube heat exchanger, providing a baffle on the shell side __________ the heat transfer rate. (A) Increases (B) Decreases (C) Does not affect (D) May increase or decrease, depends on the type of baffle

Last Answer : (A) Increases

Description : Using an organic fluid that boils at a low temperature means that energy could be regeneratedfrom waste fluids is known as ________. a) Heat exchanger b) Heat remover c) Heat pumps d) Heat absorber

Last Answer : Heat pumps

Description : Convective heat transfer co-efficient in case of fluid flowing in tubes is not affected by the tube length/diameter ratio, if the flow is in the __________ zone. (A) Laminar (B) Transition (C) Both 'a' & 'b' (D) Highly turbulent

Last Answer : (D) Highly turbulent

Description : Momentum correction factor used in fluid flow problems accounts for the (A) Change in direction of flow (B) Change in total energy (C) Change in pressure (D) Non uniform direction of velocities at inlet & outlet sections

Last Answer : (D) Non uniform direction of velocities at inlet & outlet sections

Description : Terminal point temperature differences between fluids in case of a heat exchanger is termed as (A) Approach (B) Log mean temperature difference (C) Arithmetic mean temperature difference (D) Geometric mean temperature difference

Last Answer : (A) Approach

Description : The equivalent diameter for the annulus of a double pipe heat exchanger, whose inner pipe has fins on the outside is __________ compared to the same size pipes without fins. (A) More (B) Less (C) Same (D) Unpredictable

Last Answer : (B) Less

Description : The maximum adiabatic flame temperature is attained, when the fuel is burnt with (A) Theoretically required amount of air (B) More than theoretically required amount of air (C) Less than theoretically required amount of air (D) Theoretically required amount of oxygen

Last Answer : (D) Theoretically required amount of oxygen

Description : In a multipass shell and tube heat exchanger, tube side return pressure loss is equal to __________ the velocity head. (A) Twice (B) Four times (C) Square root of (D) Square of

Last Answer : (B) Four times