Minimum temperature upto which water can be theoretically cooled
down in the cooling tower by evaporative cooling is equal to the __________
temperature of air.
(A) Wet bulb
(B) Dry bulb
(C) Saturation
(D) Dew point

1 Answer

Answer :

Option A

Related questions

Description : The minimum temperature to which the water can be cooled in a cooling tower is the __________ temperature of air. (A) Ambient (B) Dry bulb (C) Dew point (D) Wet bulb

Last Answer : C) Dew point

Description : Moist air is cooled along the line of constant __________ , when it is passed over a cold & dry cooling coil, such that no condensation occurs? (A) Enthalpy (B) Relative humidity (C) Wet bulb temperature (D) Dew point temperature

Last Answer : (D) Dew point temperature

Description : The temperature of water cooled in cooling tower is always __________ temperature of entering air. (A) More than the wet bulb (B) Less than the wet bulb (C) Equal to the wet bulb (D) Equal to the dry bulb

Last Answer : (A) More than the wet bulb

Description : Which of the following can be calculated theoretically using steam table and Dalton's law of partial pressure; if the relative humidity and dry bulb temperature of moist air is known? (A) Dew point (B) Humidity ratio (C) Wet bulb temperature (D) None of these

Last Answer : (C) Wet bulb temperature

Description : __________ temperature remains constant during adiabatic saturation process of unsaturated air. (A) Dew point (B) Dry bulb (C) Wet bulb (D) None of these

Last Answer : (C) Wet bulb

Description : Steady state temperature reached by a small amount of liquid evaporating into a large amount of unsaturated vapour-gas mixture is called the __________ temperature. (A) Dry-bulb (B) Wet-bulb (C) Dew point (D) Adiabatic saturation

Last Answer : (B) Wet-bulb

Description : __________ is the temperature at which a gas-vapor mixture becomes saturated, when cooled at constant total pressure out of contact with a liquid. (A) Dew point (B) Bubble point (C) Dry bulb temperature (D) Wet bulb temperature

Last Answer : (A) Dew point

Description : The temperature to which a vapour gas mixture must be cooled (at varying humidity) to become saturated is called the __________ temperature. (A) Dew point (B) Wet bulb (C) Dry bulb (D) None of these

Last Answer : (D) None of these

Description : Unsaturated air (with dry bulb temperature and dew point being 35°C and 18°C respectively) is passed through a water spray chamber maintained at 15°C. The air will be cooled (A) And ... (C) At the same relative humidity (D) And dehumidified with decrease in wet bulb temperature

Last Answer : (D) And dehumidified with decrease in wet bulb temperature

Description : The dew point temperature lines on psychrometric charts are straight inclined sloping downwards to the right. When relative humidity of moist air is 100%, then (A) Wet bulb temperature=dry bulb temperature (B) ... temperature (C) Saturation temperature=dew point temperature (D) All 'a', 'b' & 'c

Last Answer : Option D

Description : Pick out the wrong statement (A) A horizontal line on the humidity chart indicates the temperature changes at constant molal humidity (B) When water is cooled from 80 to 70°C by exposure ... & air cannot be increased by either reducing the mixture temperature or by increasing the total pressure

Last Answer : (D) Relative saturation of unsaturated mixture of water vapor & air cannot be increased by either reducing the mixture temperature or by increasing the total pressure

Description : The term "cooling range" in a cooling tower refers to the difference in the temperature of (A) Cold water leaving the tower and the wet bulb temperature of the surrounding air (B) Hot water entering the ... air (C) Hot water entering the tower and the cooled water leaving the tower (D) None of these

Last Answer : (C) Hot water entering the tower and the cooled water leaving the tower

Description : In a forced draft cooling tower, water is cooled from 95 to 80°F by exposure to air with a wet bulb temperature of 70°F. In this case, the (A) Range is 15°F (B) Approach is 10°F (C) Both (A) & (B) (D) Neither (A) nor (B)

Last Answer : (C) Both (A) & (B)

Description : The term "approach" in a cooling tower refers to the difference in the temperature of the (A) Cold water leaving the tower and the wet bulb temperature of the surrounding air (B ... (C) Hot water entering and the cooled water leaving the cooling tower (D) None of these

Last Answer : (A) Cold water leaving the tower and the wet bulb temperature of the surrounding air

Description : In a forced draft cooling tower, water is cooled from 95 to 80°F by exposure to air with a wet bulb temperature of 70°F. In this case, the (A) Range is 15°F (B) Approach is 10°F (C) Both (A) & (B) (D) Neither (A) nor (B)

Last Answer : (C) Both (A) & (B)

Description : During dehumidification of unsaturated air wet bulb temperature & partial pressure of vapor are not constant. However, during evaporative cooling process with recirculated water supply, the __________ remains ... pressure of water vapor (C) Relative humidity (D) None of these

Last Answer : (A) Wet bulb temperature

Description : The dew point of moist air becomes __________ with decrease in its relative humidity. (A) Less than the wet bulb temperature (B) More than the wet bulb temperature (C) More than the dry bulb temperature (D) Equal to wet bulb temperature

Last Answer : Option A

Description : Air initially at 101. 3 kPa and 40°C and with a relative humidity of 50%, is cooled at constant pressure to 30°C. The cooled air has a (A) Higher dew point (B) Higher absolute (specific) humidity (C) Higher relative humidity (D) Higher wet bulb temperature

Last Answer : (C) Higher relative humidity

Description : The cooling water reduces the water temperature close to _____. • Dry bulb temperature • Ambient wet bulb temperature • Dew point temperature • None of the above

Last Answer : Ambient wet bulb temperature

Description : Dry bulb temperature of unsaturated air is more than its __________ temperature. (A) Dew point (B) Wet bulb (C) Both 'a' & 'b' (D) Neither 'a' nor 'b

Last Answer : (C) Both 'a' & 'b

Description : psychrometer does not measure the __________ temperature of moist air. (A) Dew point (B) Dry bulb (C) Wet bulb (D) None of these

Last Answer : Option A

Description : During sensible cooling of air, its wet bulb temperature (A) Decreases but dew point remains constant (B) Increases but dew point remains constant (C) Increases & the dew point decreases (D) Decreases & the dew point increases

Last Answer : (B) Increases but dew point remains constant

Description : Which of the following processes is followed by unsaturated air (with dry bulb temperature 12°C and relative humidity 47%) passing through water spray washer (temperature of water being constant at 40°C ... (B) Heating only (C) Both heating and humidification (D) Evaporative cooling

Last Answer : (C) Both heating and humidification

Description : Which of the following remains constant during evaporative cooling process with recirculated water supply? (A) Relative humidity (B) Partial pressure of vapour (C) Wet bulb temperature (D) None of these

Last Answer : (C) Wet bulb temperature

Description : Which of the following decreases during evaporative cooling process with recirculated water supply? (A) Wet bulb temperature (B) Relative humidity (C) Partial pressure of vapour (D) None of these

Last Answer : (D) None of these

Description : Which of the following increases during evaporative cooling process with recirculated water supply? (A) Wet bulb temperature (B) Relative humidity (C) Partial pressure of vapour (D) Both (B) and (C)

Last Answer : (D) Both (B) and (C)

Description : __________ temperature is the steady state temperature attained by a small amount of liquid evaporating into a large quantity of unsaturated gas￾vapor mixture. (A) Dry bulb (B) Wet bulb (C) Dew point (D) None of these

Last Answer : (B) Wet bulb

Description : When dry bulb temperature & wet bulb temperature of moist air is the same, it means that the (A) Partial pressure of water vapour is less than the total pressure (B) Humidity is < 100% & dew ... Dew point temperature of air has not reached & air is not saturated fully (D) Air is fully saturated

Last Answer : (D) Air is fully saturated

Description : In case of unsaturated air (A) Dew point < wet bulb temperature (B) Wet bulb temperature < dry bulb temperature (C) Both (A) and (B) (D) Neither (A) not (B)

Last Answer : (C) Both (A) and (B)

Description : During sensible heating of humid air (A) Relative humidity increases (B) Dew point remains constant (C) Dry bulb & wet bulb temperature increases (D) Both 'b' & 'c'

Last Answer : (D) Both 'b' & 'c'

Description : _________ is the temperature to which the air must be cooled, at constant pressure, to produce saturation.  a. relative humidity  b. triple point temperature  c. dew point  d. critical point

Last Answer : dew point

Description : Wet-bulb temperature is: a. The temperature indicated by a thermometer whose bulb covered by a water-wetted wick and exposed to a rapidly moving stream of air b. The same as the dry-bulb ... point temperature d. Always less than the dry-bulb temperature e. Not required to find the relative humidity

Last Answer : Answer: A

Description : An indication of sensible heat content in air-water vapour mixture is a) wet bulb temperature b) dew point temperature c) density of air d) dry bulb temperature

Last Answer : d) dry bulb temperature

Description : At any point on the saturation curve in psychometric chart, the dry bulb temperature is always A. less than the corresponding wet bulb temperature B. more than the corresponding wet bulb temperature C. equal to the corresponding wet bulb temperature D. cannot predict

Last Answer : ANSWER : C

Description : Dry-bulb temperature is: a. The absolute temperature corresponding to the atmospheric pressure b. The same as the wet-bulb temperature if the relative humidity is less than 100% c. Not required ... d. The temperature of the air measured with an ordinary thermometer e. The dew point temperature

Last Answer : Answer: D

Description : A better indicators for cooling tower performance is _____. • Wet bulb temperature • Dry bulb temperature • Range • Approach

Last Answer : Approach

Description : In ________ cooling tower there is no direct contact between the water and Air. • Dry type • Evaporative type • Once through • All of the above

Last Answer : All of the above

Description : At 100% relative humidity, the dew point temperature of moist air is (A) Less than the wet bulb temperature (B) More than the wet bulb temperature (C) Equal to the wet bulb temperature (D) Equal to the ambient temperature

Last Answer : (B) More than the wet bulb temperature

Description : Can a cooling tower cool water below the wet bulb temperature of inlet air? (A) Yes (B) No (C) Yes; but height of cooling tower will be prohibitively high (D) Yes; but the air flow rate should be excessively high

Last Answer : (B) No

Description : Unsaturated air (with dry bulb and wet bulb temperatures being 45°C and 25°C respectively) is passed through a water spray chamber maintained at 23°C. The air will be cooled and (A) ... temperature decreasing B) Humidified at constant wet bulb temperature (C) Dehumidified (D) None of these

Last Answer : (A) Humidified with wet bulb temperature decreasing

Description : In chemical dehumidification process (A) Wet bulb temperature increases (B) Dry bulb temperature remains constant (C) Dew point temperature increases (D) Dry bulb temperature increases

Last Answer : Option B

Description : Pick out the wrong statement pertaining to the cooling towers. (A) In case of induced draft cooling tower, the fan is placed at the top of the tower (B) Effectiveness of ... Effectiveness of a mechanical draft cooling tower is reduced with increase in air wet-bulb temperature

Last Answer : (D) Effectiveness of a mechanical draft cooling tower is reduced with increase in air wet-bulb temperature

Description : __________ remains constant during the adiabatic cooling of moist air. (A) Wet bulb temperature (B) Dry bulb temperature (C) Relative humidity (D) Specific humidity

Last Answer : Option A

Description : When sizing a cooling tower the highest anticipate__________ should be used? • Dry bulb • Wet bulb • Both dry and wet bulb • None of the above

Last Answer : Wet bulb

Description : When the psychometric ratio is __________ then the adiabatic saturation temperature and wet bulb temperature becomes equal. (A) 1 (B) < 1 (C) > 1 (D) ∞

Last Answer : (A) 1

Description : For the air water system under ambient conditions, the adiabatic saturation temperature and the wet bulb temperature are nearly equal, because (A) Water has a high latent heat of evaporation (B) Lewis number is close to unity (C) They are always equal under all circumstances

Last Answer : (A) Water has a high latent heat of evaporation

Description : The dew point of a saturated gas phase equals the __________ temperature. (A) Gas (B) Room (C) Wet bulb (D) None of these

Last Answer : (A) Gas

Description : Wet bulb and dry bulb temperatures becomes identical at __________ percent saturation curve. (A) 100 (B) 50 (C) 78 (D) None of these

Last Answer : (A) 100

Description : Unsaturated air (with dry and wet bulb temperatures being 35 and 25°C respectively) is passed through water spray chamber maintained at 35°C. The air will be (A) Cooled (B) Humidified (C) Both (A) & (B) (D) Dehumidified

Last Answer : (B) Humidified