What is the rating of generator PT fuse?

1 Answer

Answer :

24 kV, 3.15 Amps.  

Related questions

Description : Why PT fuse fails protection?  

Last Answer : Mho relays will mal-operate if PT voltage is lost to the relay, so tripping blocked by sensing PT fuse failure. 

Description : Why AVR changes over to manual on AVR PT fuse failure? 

Last Answer : Because loss of feedback to voltage corrector.  

Description : Which of the following precautions should be taken when a blown fuse, rated at 10 amperes, is replaced? A. Short out the fuse before removing it from the circuit. B. Use needle-nose pliers to ... D. Fuses of 10 ampere rating and less are virtually harmless when energized and may be handled freely.

Last Answer : Answer: C

Description : In the illustration if BRANCH NO. 1 is a lighting circuit for crew's berthing, Federal Regulations (46 CFR) require the maximum fuse rating for that branch to be _________. EL-0013 A. 80% of the connected load B. 15 amps C. 20 amps D. 30 amps

Last Answer : Answer: C

Description : In the illustration if BRANCH NO. 1 is a lighting circuit for crew's berthing, 46 CFR requires the maximum fuse rating for that branch to be _________. EL-0013 A. 15 amps B. 80% of the connected load C. 20 amps D. 30 amps

Last Answer : Answer: C

Description : Using a fuse whose rating is higher than necessary ________. A. endangers the apparatus it is supposed to protect B. reduces the possibility of short circuits C. increases the efficiency of the equipment by allowing more current to be used D. wastes money because they are more expensive

Last Answer : Answer: A

Description : If a fuse of correct size and type blows frequently, ________________. A. try the next higher amperage rating B. try the next lower amperage rating C. look for trouble within the circuit D. reduce the applied voltage 10%

Last Answer : Answer: C

Description : When replacing fuses, always make sure _______________. A. to stand on a rubber mat and use rubber gloves B. to use insulated pliers or screwdriver C. the fuse clips are straight, tight, and in good contact D. to increase the fuse rating 10% to guard against 'nuisance blowing'

Last Answer : Answer: C

Description : A fuse that blows often should be replaced only with a fuse of _____________. A. the recommended current and voltage rating B. higher current and voltage rating C. higher current and lower voltage rating D. lower current and higher voltage rating

Last Answer : Answer: A

Description : In order to safely carry out repairs to a generator circuit breaker, it must be isolated from the bus. This is accomplished by opening the _____________. A. reverse power relay B. bus disconnect link C. generator bus fuse connections D. power directional relay

Last Answer : Answer: B

Description : What is the fuse rating in HT side of 11.4kv500kva transformer?

Last Answer : You need to specify the phase. I assume it is 3 phase system.Then the HT current is 30.3 amps

Description : What does the voltage rating of a fuse indicate?

Last Answer : The ability of the fuse to quickly extinguish the arc after the fuse element melts and the maximum voltage that cannot jump across the gap of the fuse after the fuse opens.

Description : What does the current rating of a fuse indicate?

Last Answer : The amount of current the fuse will allow without opening.

Description : The rating of fuse wire is always expressed in   (a) volts (b) amperes (c) ampere-volt (d) ampere-hours 

Last Answer : The rating of fuse wire is always expressed in Amperes 

Last Answer : The fuse rating is expressed in terms of current.

Description : To measure insulation resistance of equipments of voltage rating upto 440 V the megger generator must generate   (a) 220 V (b) 440 V (c) 500 V (d) None of these 

Last Answer : 500 V

Description : Difference between Current Transformer (CT) and Potential Transformer (PT)

Last Answer : Current Transformers (CT) and Potential Transformers (PT) are used to measure the current and voltage in a circuit of the order of hundreds of amperes and volts respectively. A CT has large number of ... and flux density vary over a wide range whereas in PT, they vary over a limited range only

Description : What are the checks on CT & PT?

Last Answer : a) Polarity checks b) Insulation checks c) Ratio checks d) Knee point voltage (only for PS class CT)- magnetising characteristic test. 

Description : What is the purpose of CT & PT?

Last Answer : For transformation of current, voltage to a lower level for the purpose of Measurement, Protection and Control. 

Description : What is the equation for resistance measurement of PT 100 thermocouple? 

Last Answer : °C = (R-100) / 0.39  

Description : What is the difference between PT and normal transformer?  

Last Answer : Burden of PT is less and burden of normal transformer is high.  

Description : Draw a neat sketch and explain the use of CT and PT for measurement of power in a single-phase circuit?

Last Answer : If wattmeter of proper range is not available or if voltage and current ranges are high we can usr CT and PT of suitable ratio. Connect the CT and PT as shown in figure. The reading of wattmeter can be multiplied by the ratio to get the actual power.   

Description : To achieve low PT error, the burden value should be ____________. (A) low (B) high (C) medium (D) none of the above

Last Answer : Ans: A In a Potential transformer, burden should be in permissible range to maintain errorless measurement.

Description : The boundary of the protective zone is determined by the (A) Location of CT (B) sensitivity of relay used (C) Location of PT (D) None of these

Last Answer : Ans: B The boundary of the protective zone is determined by the sensitivity of relay used. If the relay is more sensitive, the protective zone will be increased.

Description : Booster transformer should never: a) Have fuse in the HV winding b) Be left open circuited c) Be left closed circuited d) None of the above

Last Answer : Ans: B

Description : Which one of the following applications software’s is used to obtain an accurate root locus for? a) LISP b) MATLAB c) dBase d) Oracle Ans: B 6.Lenz devised a rule to find out direction of a)current induced in a circuit b)electromagneticdifference c)potential difference d)flow of power in fuse

Last Answer : Ans: A

Description : When changing fuses, you should always _____________. A. wear rubber boots B. use a fuse puller C. stand on a rubber mat D. wear safety glasses

Last Answer : Answer: B

Description : If a voltage tester is being used to check for defective fuses in the circuit, shown in the illustration, which of the readings will indicate that fuse #2 is open? EL-0062 A. C-B full voltage B. A-D full voltage C. A-D no voltage D. C-B no voltage

Last Answer : Answer: C

Description : If fuse 'F-1' in the illustrated schematic diagram opens, ____________. EL-0017 A. the motor will run slowly B. 'A-1' and 'A-2' will open C. the motor will not start D. the start button will jam in the closed position

Last Answer : Answer: C

Description : In the lighting distribution circuit shown in the illustration, if all switches are closed and fuse 'F2' were to open, all lights on branches ____________. EL-0013 A. '1', '2', and '3' would go out B. '1' ... and '3' would burn dimly D. '1' and '3' would go out, while branch '2' would remain lit

Last Answer : Answer: D

Description : The schematic diagram shown in the illustration uses symbol 'A' to represent a/an _________. EL-0011 A. non-renewable fuse link B. circuit breaker coil C. overload relay coil D. thermal overload heater

Last Answer : Answer: D

Description : If fuse #1 shown in the illustration is defective, a voltage tester connected across points 'C' and 'B' will ____________. EL-0062 A. show a reading of 55 volts B. show full line voltage ... C. give positive indication that fuse #2 is good D. give positive indication that fuse #1 is defective

Last Answer : Answer: D

Description : In order to determine whether or not 'fuse 2' shown in the illustration is defective, you should connect the voltage tester leads across points _____________. EL-0062 A. AC B. AD C. BC D. BD

Last Answer : Answer: B

Description : In order to determine whether or not 'Fuse 1', shown in the illustration is defective, you should connect the voltage tester leads across points _____________. EL-0062 A. AC B. AD C. BC D. BD

Last Answer : Answer: C

Description : What is represented by the electric symbol figure 'D' in the illustration? EL-0005 A. Fuse B. Plug-in contact resistor C. Variable capacitor D. Electrolytic capacitor

Last Answer : Answer: A

Description : If an electric motor fails to start, you should FIRST check the _____________. A. phase sequence B. ampere load C. fuse or circuit breaker D. line frequency

Last Answer : Answer: C

Description : When testing for blown fuses in a three-phase supply circuit to a motor, you should first ___________________. A. apply the megger across the tops of the line fuses B. apply an ammeter diagonally across ... of the line fuses D. ensure the circuit is de-energized, and then use a continuity tester

Last Answer : Answer: D

Description : When an AC or a DC motor fails to start, the FIRST step in troubleshooting should be to check the ____________. A. motor windings for obvious opens B. motor controller leads for continuity C. fuse or circuit breaker D. motor controller leads for grounds

Last Answer : Answer: C

Description : In the illustrated motor controller, the motor fails to start. A voltmeter reading between 1 and 6 reads line voltage, while the voltmeter reading between 2 and 6 reads 0 VAC. The problem is __________. EL- ... in the 'M' coil, 'Ma' contact/start switch or overload contacts D. fuse '10a' is blown

Last Answer : Answer: B

Description : A circuit with a blown fuse would be described as a/an _____________. A. short circuit B. open circuit C. bonded circuit D. grounded circuit

Last Answer : Answer: B

Description : A fuse will 'blow' if _____________. A. an electric motor is stopped suddenly by opening a switch B. the flow of current to the protection device is reversed C. the electrical current exceeds the rated value of the fuse D. unequal resistors are connected in parallel

Last Answer : Answer: C

Description : In addition to short circuits and sustained overloads, fuses are likely to blow due to _____________. A. loose fuse clips B. low ambient temperatures C. low contact resistance D. all of the above

Last Answer : Answer: A

Description : In the illustration, 'D' is the symbol for a/an __________. EL-0005 A. thermal overload heater B. portable cable C. fuse D. indicating lamp

Last Answer : Answer: C

Description : A fuse will blow for all the listed reasons EXCEPT ________. A. excessive vibration B. extremely hot surroundings C. loose fuse clips D. low contact resistance within the fuse

Last Answer : Answer: D

Description : When troubleshooting a motor controller, all indications are that a relay coil should be energized. If there were no magnetic pull, with rated voltage measured across the coil, the most probable cause ... open C. auxiliary contact in series with the coil is defective D. relay armature is stuck

Last Answer : Answer: A

Description : When troubleshooting motor controllers, a shorted relay or contactor coil is often indicated by _______________. A. a resistance reading of 'infinity' on an ohmmeter B. charred insulation and/or a blown ... of the coil's leads to ground D. a higher-than-normal voltage reading across the winding

Last Answer : Answer: B

Description : You are using a mechanical voltage tester to check the fuses in a three-phase circuit supplying an electric motor. For which of the following reasons must the motor be stopped during the test? A. ... circuit would be indicated by the voltage tester with the circuit energized. D. All of the above.

Last Answer : Answer: B

Description : If the motor fails to start and a voltmeter reading between 1 and 6, as illustrated, indicates line voltage, your next step should be to ________. EL-0007 A. replace fuse '10a' B. replace or repair contact 'Ma' C. reset and determine the cause of the overload D. check line voltage between L1 and L3

Last Answer : Answer: C

Description : An instantaneous-trip-type fuse will _____________. A. open as soon as the load current exceeds its set point B. allow a preset delay between overcurrent and melting C. open a circuit by using a time delay element with a magnetic trip D. reset itself when the overcurrent is corrected

Last Answer : Answer: A

Description : Component 'C' in section 'I' shown in the illustration represent ____________. EL-0093 A. a selectable holding coil arrangement B. a 'fuse blown' indicator circuit C. 'reset' and 'trouble' lamps D. a handset with switch and voice elements

Last Answer : Answer: D