Why AVR changes over to manual on AVR PT fuse failure? 

1 Answer

Answer :

Because loss of feedback to voltage corrector.  

Related questions

Description : What are the protective parameters to changeover AVR auto to manual? 

Last Answer : a. PT supply fail. b. Auto pulse fail. c. Supply of limiter fail. d. Supply of auto channel fail. e. Regulated supply fail. f. High auto reference. 

Description : Why PT fuse fails protection?  

Last Answer : Mho relays will mal-operate if PT voltage is lost to the relay, so tripping blocked by sensing PT fuse failure. 

Description : What is the rating of generator PT fuse?

Last Answer : 24 kV, 3.15 Amps.  

Description : In the event of a power failure during cargo loading operations, the movement of an electric powered cargo winch will be stopped by ____________. A. a manual override switch B. the weight of the load on the boom C. a spring set brake D. a hand operated band brake

Last Answer : Answer: C

Description : What is Automatic Voltage regulator (AVR)?

Last Answer : AVR is an abbreviation for Automatic Voltage Regulator. It is important part in Synchronous Generators; it controls the output voltage of the generator by controlling its excitation current. Thus it can control the output Reactive Power of the Generator.

Description : What Is Automatic Voltage Regulator(avr)?

Last Answer : AVR is an abbreviation for Automatic Voltage Regulator. It is important part in Synchronous Generators, it controls the output voltage of the generator by controlling its excitation current. Thus it can control the output Reactive Power of the Generator.

Description : What is Automatic Voltage regulator (AVR)?

Last Answer :  AVR is an abbreviation for Automatic Voltage Regulator.  It is important part in Synchronous Generators; it controls the output voltage of the generator by controlling its excitation current. Thus it can control the output Reactive Power of the Generator.

Description : which is the best kardon avr?

Last Answer : It all depends on what you're looking for in your AVR. I'd go with a basic one if you don't need some of the more advanced features.

Description : A database of information that is maintained by human editors and lists websites by category and subcategory with categorization is known as: 1. A search directory 2. Automated voice response (AVR) 3. Apps 4. Search Engine Optimization (SEO

Last Answer : A search directory

Description : If the AVR, is defective, when additional loads come on will the generator be able to take it?

Last Answer : No. Ask E/O and refer to Dennis T Hall.

Description : Which instruction set architecture is used in Raspberry Pi? A. X86 B. MSP C. AVR D. ARM

Last Answer : D. ARM 

Description : AVR microcontroller executes most of the instruction in _________________. A. Single execution cycle. B. Double execution cycle. C. Both A& B D. None of the above.

Last Answer : architecture of embedded system consists of

Description : AVR stands for_____________________. A. Advanced Virtual RISC. B. Alf-Egil Bogen and Vegard Wollan RISC C. Both A & B D. None of the above

Last Answer : C. Both A & B 

Description : ______________ was developed in the year 1996 by ATMEL Corporation A. PIC B. AVR C. ARM D. ASIC

Last Answer : B. AVR 

Description : ______________ is the smallest microcontrollers which can be programmed to perform a large range of tasks. A. PIC microcontrollers B. ARM microcontrollers C. AVR microcontrollers D. ASIC microcontrollers

Last Answer : A. PIC microcontrollers 

Description : Compare features of PIC and AVR microcontrollers

Last Answer : Parameters PIC AVR Bus width 8/16/32-bit 8/32-bit Communication Protocols UART, USART, LIN, CAN, Ethernet, SPI, I2C UART, USART, SPI, I2C, (special ... Average Atmel Popular Microcontrollers PIC18fXX8, PIC16f88X, PIC32MXX Atmega8, 16, 32, Arduino Community

Description : In the head and neck: a. the lymph from the upper lid drains to the parotid and submandibular lymph nodes b. the facial nerve comes from the first pharyngeal arch c. branches of the ... e. an unilateral cleft lip is a failure of the maxillary process to fuse with the medial nasal process

Last Answer : branches of the ophthalmic division of the trigeminal nerve supply the skin of the scalp as far backward as the vertex

Description : A circuit breaker and a fuse have a basic similarity in that they both _____________. A. can be reset to energize the circuit B. should open the circuit when overloaded C. will burn out when an over current flow develops D. all of the above

Last Answer : Answer: B

Description : When the fuse will take over?

Last Answer : When the current increases beyond 700% then the fuse will take over from the thermal overload protection.  

Description : ACSR (Aluminium Conductor Steel Reinforced) are used as (A) over head transmission lines. (B) super conductors. (C) fuse (D) underground cables.

Last Answer : (A) over head transmission lines.

Description : Difference between Current Transformer (CT) and Potential Transformer (PT)

Last Answer : Current Transformers (CT) and Potential Transformers (PT) are used to measure the current and voltage in a circuit of the order of hundreds of amperes and volts respectively. A CT has large number of ... and flux density vary over a wide range whereas in PT, they vary over a limited range only

Description : What are the checks on CT & PT?

Last Answer : a) Polarity checks b) Insulation checks c) Ratio checks d) Knee point voltage (only for PS class CT)- magnetising characteristic test. 

Description : What is the purpose of CT & PT?

Last Answer : For transformation of current, voltage to a lower level for the purpose of Measurement, Protection and Control. 

Description : What is the equation for resistance measurement of PT 100 thermocouple? 

Last Answer : °C = (R-100) / 0.39  

Description : What is the difference between PT and normal transformer?  

Last Answer : Burden of PT is less and burden of normal transformer is high.  

Description : Draw a neat sketch and explain the use of CT and PT for measurement of power in a single-phase circuit?

Last Answer : If wattmeter of proper range is not available or if voltage and current ranges are high we can usr CT and PT of suitable ratio. Connect the CT and PT as shown in figure. The reading of wattmeter can be multiplied by the ratio to get the actual power.   

Description : To achieve low PT error, the burden value should be ____________. (A) low (B) high (C) medium (D) none of the above

Last Answer : Ans: A In a Potential transformer, burden should be in permissible range to maintain errorless measurement.

Description : The boundary of the protective zone is determined by the (A) Location of CT (B) sensitivity of relay used (C) Location of PT (D) None of these

Last Answer : Ans: B The boundary of the protective zone is determined by the sensitivity of relay used. If the relay is more sensitive, the protective zone will be increased.

Description : Coast Guard Regulations (46 CFR) require manual contactors for operating the general emergency alarm on tank vessels to be located in the navigating bridge, engine room and the ____________. A ... C. crew accommodations and sleeping spaces D. engineering officers' quarters furthest from the bridge

Last Answer : Answer: A

Description : As shown in the illustration, all 'MS' contacts are opened and closed by means of ________. EL-0073 A. operating coils B. magnets C. manual operation of the master switches D. solenoid switches

Last Answer : Answer: C

Description : As shown in the illustration, which of the following conditions will occur as a result of a momentary loss of power? EL-0017 A. The motor will automatically restart when power is restored. B. 'H-4' will open, ... the motor. D. 'A-1' or 'A-2' will open, necessitating a manual restarting of the motor.

Last Answer : Answer: B

Description : The device labeled 'REG SW' in the illustration is used to ___________. EL-0003 A. shift from the automatic voltage regulator to the manual voltage regulator B. shift the governor control from manual to ... device 'REG ADJ' or device 'MAN ADJ' D. supply regulated control power to the switchboard

Last Answer : Answer: A

Description : When securing an AC generator, you should FIRST ___________. A. open the generator circuit breaker B. switch the voltage regulator to 'manual' C. decrease the field excitation to minimum D. reduce the load on the unit

Last Answer : Answer: D

Description : Prior to starting an AC generator prime mover, the voltage regulator cutout switch should be placed in the __________. A. manual position B. bus neutral position C. raise voltage position D. transfer position

Last Answer : Answer: A

Description : Low voltage releases as used in some shipboard motor starter and control equipment will have which of the following characteristics? A. They trip circuit contactors when the motor starts to overspeed. B. ... coil of the starter. D. They allow the motor to restart upon restoration of normal voltage.

Last Answer : Answer: D

Description : What is the difference between an auto reset and manual reset overload relay?

Last Answer : a. Auto reset relay closes its contacts when the bimetallic strip gets cooled. In manual reset relay we have to manually reset the relay because even though bimetallic strip cools its contacts are not ... . Manual over load relay is reseted by pushing the reset button provided on the MCC cell. 

Description : Booster transformer should never: a) Have fuse in the HV winding b) Be left open circuited c) Be left closed circuited d) None of the above

Last Answer : Ans: B

Description : Which one of the following applications software’s is used to obtain an accurate root locus for? a) LISP b) MATLAB c) dBase d) Oracle Ans: B 6.Lenz devised a rule to find out direction of a)current induced in a circuit b)electromagneticdifference c)potential difference d)flow of power in fuse

Last Answer : Ans: A

Description : When changing fuses, you should always _____________. A. wear rubber boots B. use a fuse puller C. stand on a rubber mat D. wear safety glasses

Last Answer : Answer: B

Description : Which of the following precautions should be taken when a blown fuse, rated at 10 amperes, is replaced? A. Short out the fuse before removing it from the circuit. B. Use needle-nose pliers to ... D. Fuses of 10 ampere rating and less are virtually harmless when energized and may be handled freely.

Last Answer : Answer: C

Description : If a voltage tester is being used to check for defective fuses in the circuit, shown in the illustration, which of the readings will indicate that fuse #2 is open? EL-0062 A. C-B full voltage B. A-D full voltage C. A-D no voltage D. C-B no voltage

Last Answer : Answer: C

Description : If fuse 'F-1' in the illustrated schematic diagram opens, ____________. EL-0017 A. the motor will run slowly B. 'A-1' and 'A-2' will open C. the motor will not start D. the start button will jam in the closed position

Last Answer : Answer: C

Description : In the lighting distribution circuit shown in the illustration, if all switches are closed and fuse 'F2' were to open, all lights on branches ____________. EL-0013 A. '1', '2', and '3' would go out B. '1' ... and '3' would burn dimly D. '1' and '3' would go out, while branch '2' would remain lit

Last Answer : Answer: D

Description : The schematic diagram shown in the illustration uses symbol 'A' to represent a/an _________. EL-0011 A. non-renewable fuse link B. circuit breaker coil C. overload relay coil D. thermal overload heater

Last Answer : Answer: D

Description : In order to safely carry out repairs to a generator circuit breaker, it must be isolated from the bus. This is accomplished by opening the _____________. A. reverse power relay B. bus disconnect link C. generator bus fuse connections D. power directional relay

Last Answer : Answer: B

Description : If fuse #1 shown in the illustration is defective, a voltage tester connected across points 'C' and 'B' will ____________. EL-0062 A. show a reading of 55 volts B. show full line voltage ... C. give positive indication that fuse #2 is good D. give positive indication that fuse #1 is defective

Last Answer : Answer: D

Description : In order to determine whether or not 'fuse 2' shown in the illustration is defective, you should connect the voltage tester leads across points _____________. EL-0062 A. AC B. AD C. BC D. BD

Last Answer : Answer: B

Description : In order to determine whether or not 'Fuse 1', shown in the illustration is defective, you should connect the voltage tester leads across points _____________. EL-0062 A. AC B. AD C. BC D. BD

Last Answer : Answer: C

Description : What is represented by the electric symbol figure 'D' in the illustration? EL-0005 A. Fuse B. Plug-in contact resistor C. Variable capacitor D. Electrolytic capacitor

Last Answer : Answer: A