Why the tap changers are always connected to HV side of the transformer? 

1 Answer

Answer :

During tap changing action the load current has to be shifted from one tap to another tap. In case HV wining the load current will be less. Hence lesser arcing will take place. 

Related questions

Description : In a Tap changing transformer on which side is the tap connected, primary side or secondary side?

Last Answer : A. Tapings are always connected to high voltage winding side, because of low current. If we connect tapings to low voltage side, sparks will produce while tap changing operation due to high current.

Description : Why SC test is generally performed on HV side of a transformer?

Last Answer : The rated current is less on HV side. This will also permit to use ammeter and wattmeter of lower current range.

Description : Why in transformer the LV CB also be tripped along with HV CB for a primary side fault?

Last Answer : Auxiliary transformer 415v delta star transformer, if HV CB alone tripped then back feeding from LV side (say DG runs parallel with transformer)—arcing voltage at the fault on primary—fault fed for more time – more damage.  

Description : Booster transformer should never: a) Have fuse in the HV winding b) Be left open circuited c) Be left closed circuited d) None of the above

Last Answer : Ans: B

Description : A 400/200 volts transformer has pu impedance of 0.05. The HV side voltage required to circulate full load current during short circuit test is

Last Answer : A 400/200 volts transformer has pu impedance of 0.05. The HV side voltage required to circulate full load current during short circuit test is 20 V

Description : Why the tapings are placed on HV side?

Last Answer : 1.A fine voltage regulation is possible with hV side as it has large number of turns. 2.LV side carries large current 3. HV side is placed outside so its feasible 4. In case of step ... large no. of turns the flux and flux density decreases. Hence core losses decreases results in higher efficiency.

Description : Why REF is now is used for HV side also in GT/SUT?

Last Answer : The E/F setting of differential is poor.  

Description : Why there is no mixing of oil of tap changer and transformer?

Last Answer : When the tap changing takes place arc is struck between the contacts. Due to this the oil inside the tap changer will be highly carbonised. If both oil get mixed up the quality of transformer tank oil will come down. This is not advisable. Hence both oils are kept separately. 

Description : In a three phase transformer, if the primary side is connected in star and secondary side is connected in delta, what is the angle difference between phase voltage in the two cases. (A) delta side lags by -30°. (B) star side lags by -30°. (C) delta side leads by 30°. (D) star side leads by -30°.

Last Answer : Ans: C This is vector group and has +30° displacement. Therefore, delta side leads by +30°.

Description : An autotransformer is equipped with a 50% tap, a 65% tap, and an 80% tap. Which of the following statements is true concerning a load connected to the 50% tap? A. The load is ... is receiving maximum voltage and minimum current. D. The load is receiving maximum voltage and maximum current.

Last Answer : Answer: B

Description : Before touching a small capacitor connected to a de-energized circuit, or even one that is completely disconnected, you should ____________. A. gently tap the body with a screwdriver B. tag it ... insulated fuse puller D. short circuit the terminals to make sure that the capacitor is discharged

Last Answer : Answer: D

Description : Mention the various tests carried out in a circuit breaker at HV labs.

Last Answer : Short circuit tests, Synthetic tests& direct tests.

Description : What is the purpose of HV / leakage current test on stator?  

Last Answer : This is to find out weakness in the stator winding. If the ambient conditions are right, and the insulation is weak, the leakage current will increase non-linearly.  The record of voltage ... current. In HV test starting leakage current should be more than switching off current in μ Amps. 

Description : What is the DC HV test voltage range?

Last Answer : 1.7* 1.5* rated voltage.

Description : When did Fluther get started? Any major milestones and game changers since the beginning?

Last Answer : Welcome to Fluther. I believe it started in 2007. I've been here since the end of 2009. It was a large-ish site. What set it apart was the rule requiring high writing standards. Also, we ... us their questions, and the community will do its best to try to get accurate information. Enjoy yourself.

Description : Will I find any used tire changers on Craig's List?

Last Answer : You can find umpteen used tire changers on Craig's List. You will be surprised to see the number of items that appear when you search, with the used tire changers appearing in Craig's list of most cities ... on the website and sign up for an account and type in used tire changers on the search box.

Description : are cd changers durable?

Last Answer : Most CD changers are very durable, and handle very well even on rough, bumpy roads.

Description : Do all CD changers play MP3s, or do I need special ones?

Last Answer : All current CD changers can play mp3 files taht are recorded on CD

Description : Which car CD changers come with remote controls?

Last Answer : The Clarion FMC250 has a remote control option available.

Description : What car cd changers come with a remote?

Last Answer : The Pioneer AVH-P4100 and the Jensen VM9312HD are both excellent car stereos with changes and remotes.

Last Answer : In motor circuit static frequency changers are used for speed regulation.

Description : For what is the center tap on a transformer used?

Last Answer : Provides capability of developing two high-voltage outputs

Description : In a tap changing transformer, the tappings are provided on (a) primary winding (b) secondary winding (c) high voltage winding (d) any of the above

Last Answer : (b) secondary winding

Description : Which of the following equipment, for regulating the voltage in distribution feeder, will be most economical ? (a) Static condenser (b) Synchronous condenser (c) Tap changing transformer (d) Booster transformer

Last Answer : (d) Booster transformer

Description : a single phase full wave midpoint thyristor converter uses a 230/200V transformer with centre tap on the secondary side. The P.I.V per thyristor is   (A) 100V (B)141.4V (C)200V (D)282.8V

Last Answer : d

Description : Determine the transformer tap ratios when the receiving end voltage is equal to the sending end voltage, the high voltage line operates at 220 kV and transmit 80 MW at 0.8 pf and the impedance of the line is (40+j140)ohm. Assume tstr=1.0  (A) 0.8 (B) 0.9 (C) 0.7 (D) 0.6 

Last Answer : 0.9 explanation given vs=vr convert in to phase voltage because impedence is always in phase line 220/root 3 then divided by reactive part that is 140 127.01/140=0.9 ans

Description : The diagram shown in the illustration represents a/an _____________. EL-0082 A. stepup transformer B. magnetic amplifier C. autotransformer D. Scott-connected transformer

Last Answer : Answer: A

Description : A load with an impedance of 440 ohms is connected across the secondary of the transformer illustrated. If the input voltage is 110 VAC and the step-up ratio is 10 to 1, what will be the primary current? EL-0055 A. 2.5 amps B. 25 amps C. 250 amps D. current cannot be determined with information given

Last Answer : Answer: B

Description : A load is connected to the secondary of the transformer illustrated and the current through the load is 10 amps. If the step-up ratio is 10 to 1 and the input voltage is 110 VAC, what will be the current flow through the primary? EL-0055 A. 1 amp B. 10 amps C. 100 amps D. 1000 amps

Last Answer : Answer: C

Description : In the illustrated electronic governor, the circuit card connected to the potential and current transformers is for ________. EL-0046 A. increasing the signal strength to the governor to ... from motorization D. conditioning the load through the use of a magnetic amplifier current transformer

Last Answer : Answer: A

Description : The transistors in the illustrated circuit are connected using what type of coupling? EL-0049 A. RC coupling B. transformer coupling C. LC coupling D. direct coupling

Last Answer : Answer: B

Description : The transistors in the illustrated circuit are connected using what type of coupling? EL-0048 A. RC coupling B. transformer coupling C. LC coupling D. direct coupling

Last Answer : Answer: A

Description : The transistors in the illustrated circuit are connected using what type of coupling? EL-0051 A. RC coupling B. transformer coupling C. impedance coupling D. direct coupling

Last Answer : Answer: D

Description : The transistors in the illustrated circuit are connected using what type of coupling? EL-0050 A. RC coupling B. transformer coupling C. Impedance coupling D. direct coupling

Last Answer : Answer: C

Description : In a three-phase, open-delta connected transformer, the line current is equal to _____________. A. the phase current B. three times the phase current C. the sum of any two phase currents D. the difference of any two phase currents

Last Answer : Answer: A

Description : The hook-on AC volt-ammeter consists essentially of a split-core and a rectifiertype instrument connected to the secondary winding of a _____________. A. potential transformer B. control transformer C. current transformer D. reactance transformer

Last Answer : Answer: C

Description : If a transformer is connected to a DC source, the transformer will overload at the ____________. A. contacts B. primary coil C. secondary coil D. core

Last Answer : Answer: B

Description : What is the maximum current allowed to be drawn from the secondary of a 2 KVA step-down transformer with a turns ratio of four to one if connected across a 440 volt line? A. 1.1 amps B. 4.5 amps C. 18.1 amps D. 22.7 amps

Last Answer : Answer: C

Description : What is the maximum allowable primary current of a 2 KVA step-down transformer with a four to one turns ratio if connected across a 440 volt line? A. 1.1 amps B. 4.5 amps C. 18.1 amps D. 27.7 amps

Last Answer : Answer: B

Description : A transformer has a turns ratio of two to one. If a 100 ohm resistor is connected on the high side, its resistance as measured on the low side would be: w) 25 ohms x) 50 ohms y) 100 ohms z) 400 ohms

Last Answer : ANSWER: W -- 25 OHMS

Description : In a three phase transformer, if the primary side is connected in star and secondary side is connected in delta, the angle difference between phase voltage in the two cases will be: (A) delta side will lag by -30° ... will lag by -30° (C) delta side will lead by 30° (D) star side will lead by -30°

Last Answer : In a three phase transformer, if the primary side is connected in star and secondary side is connected in delta, the angle difference between phase voltage in the two cases will be: delta side will lead by 30° 

Description : What is the full form of 'HV' ? -How To ?

Last Answer : The full form of 'HV' is High Voltage

Description : I hv 300 oman baisa where cn I change it plzz?

Last Answer : Western Asia

Description : In the following reaction: `ZnS+O_(2)overset(Delta)rarrA+ZnO` `4HCl+O_(2)overset(CuCl_(2))rarrB+2H_(2)O` `A+B overset(hv)rarrC` Then A, B and C are:

Last Answer : In the following reaction: `ZnS+O_(2)overset(Delta)rarrA+ZnO` `4HCl+O_(2)overset(CuCl_(2))rarrB+2H_(2)O` ` ... SOCl_(2)` D. `SO_(3),HClO_(3),HClO_(4)`

Description : De Broglie equation is (a) h/mv = 1 (b) E1 – E2 = hv (c) C = 1v (d) n1 = 2d sin q

Last Answer : Ans:(a)

Description : The de Broglie equation is (a) h/mv = 1 (b) hv = E2 - E1 (c) n 1 = 2d sin (d) c = hv

Last Answer : Ans:(a)

Description : The unity of Planck's constant 'h' in the equation, E = hv is (A) J/s (B) J.S (C) J/kmol (D) kmol/J

Last Answer : (B) J.S

Description : The probability of a photon ionizing an atom or molecule is maximum when (hv-eVi) is as small as: a. 0.5 b. 1.5 c. 3.5 d. 10 

Last Answer : The probability of a photon ionizing an atom or molecule is maximum when (hv-eVi) is as small as: a. 0.5 b. 1.5 c. 3.5 d. 10