a single phase full wave midpoint thyristor converter uses a 230/200V transformer with centre tap on the secondary side. The P.I.V per thyristor is 

 (A) 100V (B)141.4V (C)200V (D)282.8V

2 Answers

Answer :

a single phase full wave midpoint thyristor converter uses a 230/200V transformer with centre tap on the secondary side. The P.I.V per thyristor is 282.8V

Answer :

d

Related questions

Description : A single-phase, 230 V, 50 Hz ac mains fed step down transformer (4:1) is supplying power to a half-wave uncontrolled ac-dc converter used for charging a battery (12 V dc) with the series current limiting resistor being 19.04 Ohm. The charging current is  (A) 2.43 A (B) 1.65 A (C) 1.22 A (D) 1.0 A

Last Answer : A single-phase, 230 V, 50 Hz ac mains fed step down transformer (4:1) is supplying power to a half-wave uncontrolled ac-dc converter used for charging a battery (12 V dc) with the series current limiting resistor being 19.04 Ohm. The charging current is 1.0 A

Description : A single-phase fully controlled thyristor bridge ac-dc converter is operating at a firing angle of 25o and an overlap angle of 10o with constant dc output current of 20 A. The fundamental power factor (displacement factor) at input ac mains is  (A) 0.78 (B) 0.827 (C) 0.866 (D) 0.9

Last Answer : A single-phase fully controlled thyristor bridge ac-dc converter is operating at a firing angle of 25o and an overlap angle of 10o with constant dc output current of 20 A. The fundamental power factor (displacement factor) at input ac mains is 0.78

Description : A three-phase, fully controlled thyristor bridge converter is used as line commutated inverter to feed 50 kW power 420 V dc to a three-phase, 415 V(line), 50 Hz ac mains. Consider dc link current to be constant. The rms current of the thyristor is  (A) 119.05 A (B) 79.37 A (C) 68.73 A (D) 39.68 A

Last Answer : A three-phase, fully controlled thyristor bridge converter is used as line commutated inverter to feed 50 kW power 420 V dc to a three-phase, 415 V(line), 50 Hz ac mains. Consider dc link current to be constant. The rms current of the thyristor is 68.73 A

Description : A single phase full-wave half-controlled bridge converter feeds an inductive load. The two SCRs in the converter are connected to a common DC bus. The converter has to have a freewheeling diode.  (A) ... to one of the SCRs is missed, it will subsequently cause a high load current in the other SCR.

Last Answer : A single phase full-wave half-controlled bridge converter feeds an inductive load. The two SCRs in the converter are connected to a common DC bus. The converter has to have a freewheeling diode. because the converter does not provide for free-wheeling for high values of triggering angles

Description : A three-phase, 440 V, 50 Hz ac mains fed thyristor bridge is feeding a 440 V dc, 15 kW, 1500 rpm separately excited dc motor with a ripple free continuous current in the dc link under all operating conditions, Neglecting the ... at half the rated speed is  (A) 0.354 (B) 0.372 (C) 0.90 (D) 0.955

Last Answer : A three-phase, 440 V, 50 Hz ac mains fed thyristor bridge is feeding a 440 V dc, 15 kW, 1500 rpm separately excited dc motor with a ripple free continuous current in the dc link under all operating conditions, Neglecting the losses, the power factor of the ac mains at half the rated speed is 0.354

Description : A 230 V, 50 Hz phase controlled single-phase full-controlled SCR bridge converter draws 15 A constant dc current. If the source inductance is 3 mH, the drop in dc output voltage is (A) 4.5 V (B) 6.75 V (C) 9 V (D) 13.5 V

Last Answer : A 230 V, 50 Hz phase controlled single-phase full-controlled SCR bridge converter draws 15 A constant dc current. If the source inductance is 3 mH, the drop in dc output voltage is 9 V

Description : A freewheeling diode in a phase controlled converter  A) Deceases the possibility of discontinuous conduction in the load B) Increases the possibility of discontinuous conduction in the load C) Reduces the power factor and causes over voltages D) Causes over voltages

Last Answer : A freewheeling diode in a phase controlled converter Deceases the possibility of discontinuous conduction in the load 

Description : A 3-phase fully controlled bridge converter with free wheeling diode is fed from 400 V, 50 Hz AC source and is operating at a firing angle of 60o. The load current is assumed constant at 10 A due to high load inductance. The input ... 0.552 (C) IDF IPF = = 0.5; 0.478 (D) IDF IPF = = 0.5; 0.318 

Last Answer : A 3-phase fully controlled bridge converter with free wheeling diode is fed from 400 V, 50 Hz AC source and is operating at a firing angle of 60o. The load current is assumed constant at 10 A due to high ... (IDF) and the input power factor (IPF) of the converter will be IDF IPF = = 0.5; 0.478

Description : A three phase fully controlled bridge converter is feeding a load drawing a constant and ripple free load current of 10 A at a firing angle of 30o. The approximate Total harmonic Distortion (%THD) and the rms value of fundamental component ... (B) 31% and 7.8 A (C) 66% and 6.8 A (D) 66% and 7.8 A

Last Answer : A three phase fully controlled bridge converter is feeding a load drawing a constant and ripple free load current of 10 A at a firing angle of 30o. The approximate Total harmonic Distortion (%THD) and the rms value of fundamental component of input current will respectively be 31% and 7.8 A

Description : In a 230 V, 50 Hz single-phase SCR bridge converter operating at a firing delay angle, α and with large R-L load, the input source current is (A) sinusoidal current (B) constant dc current (C) continuous rectangular pulses (D) alternating rectangular pulses

Last Answer : In a 230 V, 50 Hz single-phase SCR bridge converter operating at a firing delay angle, α and with large R-L load, the input source current is alternating rectangular pulses

Description : The kVA rating of Three-phase transformer with Voltage = 200V and Current = 100A will be :  (A) 34.64 kVA (B) 75 kVA (C) 20 kVA (D) None of the above

Last Answer : The kVA rating of Three-phase transformer with Voltage = 200V and Current = 100A will be : 34.64 kVA

Description : The output voltage waveform of a three-phase square-wave inverter contains  (A) only even harmonics (B) both odd and even harmonic (C) only odd harmonics (D) only triple harmonics

Last Answer : C

Description : A 230 V/460 V single-phase transformer operating at 20 A and unity power factor has primary referred resistance of 0.2 Ω and reactance of 0.5 Ω. The approximate primary induced emf is (A) 216 V (B) 226 V (C) 234 V (D) 236 V

Last Answer : A 230 V/460 V single-phase transformer operating at 20 A and unity power factor has primary referred resistance of 0.2 Ω and reactance of 0.5 Ω. The approximate primary induced emf is 226 V

Description : Draw single phase full wave mid-point converter for inductive load. Draw input and output waveforms for it. 

Last Answer : Circuit Diagram: Waveforms:

Description : Give the operation of single phase full wave bridge controlled converter with RL load with a neat diagram. Also draw its waveform.

Last Answer : Single phase fully control bridge converter with RL load: 1. During positive half cycle of input voltage, T1 and T2 are forward biased and during negative half cycle, T3 and T4 are forward biased. Therefore, T1-T2 ... cycle till the firing of next pair of SCRs as shown in the waveform.

Description : The ripple content of load current of a converter feeding RL load is decided by  A) Load resistance alone B) Load inductance alone C) Both load resistance and load inductance D) Neither resistance nor inductance

Last Answer : The ripple content of load current of a converter feeding RL load is decided by Both load resistance and load inductance

Description : A converter which can operate in both 3 pulse and 6 pulse mode is a  (A) 1 phase full converter (B) 3 phase half wave converter (C) 3 phase semi converter (D) 3 phase full converter.

Last Answer : A converter which can operate in both 3 pulse and 6 pulse mode is a 3 phase semi converter

Description : In which type of AC to DC converter efficiency is higher :

Last Answer : In which type of AC to DC converter efficiency is higher : solid state rectifier

Description : A single phase CSI has capacitor C as the load. For a constant source current, the voltage across the capacitor is   (A) square wave (B) triangular wave (C) step function (D) pulsed wave

Last Answer : Step function

Description : Full wave centre tap rectifier?

Last Answer : In this method only two diodes are used. But it requires a center tap transformer. During the positive half cycle diode D1 conducts. In the negative half cycle diode D2 conducts. So in ... rectification converts both polarities of the input waveform to DC (direct current), and is more efficient.

Description : Draw circuit diagram and waveforms for centre-tap full wave rectifier.

Last Answer : Circuit Diagram:    

Description : An AC supply of 230 V is applied to half wave rectifier circuit. A transformer turns ratio is 20 : 1. Find i) Output DC voltage (ii) Peak Inverse Voltage (PIV)

Last Answer : Solution:

Description :  An AC supply of 230 V is applied to a half-wave rectifier circuit through a transformer having primary to secondary turn’s ratio 12:1. The peak inverse voltage is A) 8.62 V B) 12 V C) 19.17 V D) 27.11 V 

Last Answer :  An AC supply of 230 V is applied to a half-wave rectifier circuit through a transformer having primary to secondary turn’s ratio 12:1. The peak inverse voltage is A) 8.62 V B) 12 V C) 19.17 V D) 27.11 V 

Description : The low voltage winding of a 400/230 V, 1-phase, 50 Hz transformer is to be connected to a 25 Hz, the supply voltage should be

Last Answer : The low voltage winding of a 400/230 V, 1-phase, 50 Hz transformer is to be connected to a 25 Hz, the supply voltage should be 115 V.

Description : Single-phase Midpoint controlled rectifier with Resistive load

Last Answer : Single-phase Midpoint controlled rectifier with Resistive load:  1) During positive half cycle of AC supply, a is positive with respect to b , this makes T1 forward biased and T2 is reverse ... voltage reverses the polarity and T2 is turned off. The operation is as shown in waveforms.

Description : A solar cell of 350 V is feeding power to an ac supply of 440 V, 50 Hz through a 3-phase fully controlled bridge converter. A large inductance is connected in the dc circuit to maintain the dc current at 20 A ... thyristor will be reverse biased for a period of  (A) 125o (B) 120o (C) 60o (D) 55o

Last Answer : A solar cell of 350 V is feeding power to an ac supply of 440 V, 50 Hz through a 3-phase fully controlled bridge converter. A large inductance is connected in the dc circuit to maintain the ... the solar cell resistance is 0.5 Ohm ,then each thyristor will be reverse biased for a period of 125o

Description : The voltage of the single phase supply to residential consumers is (a) 110 V (b) 210 V (c) 230 V (d) 400 V

Last Answer : (c) 230 V

Description : The voltage of the single phase supply to residential consumers is (a) 110 V (b) 210 V (c) 230 V (d) 400 V

Last Answer : (c) 230 V

Description : The meter constant of a single-phase 230 V induction watt hour meter is 400 revolutions per kWh. The speed of the meter disc for a current of 10 A of 0.9 pf lagging will be

Last Answer : The meter constant of a single-phase 230 V induction watt hour meter is 400 revolutions per kWh. The speed of the meter disc for a current of 10 A of 0.9 pf lagging will be 13.80 rpm

Description : One single-phase energy meter operating on 230 V and 5 A for 5 hours makes 1940 revolutions. Meter constant is 400 rev/kWh. The power factor of the load is

Last Answer : One single-phase energy meter operating on 230 V and 5 A for 5 hours makes 1940 revolutions. Meter constant is 400 rev/kWh. The power factor of the load is 0.8

Description : Draw and describe working of full wave rectifier using centre tapped transformer.

Last Answer : Full wave Rectifier with Center tapped transformer(FWR): In full wave rectification, the rectifier conducts in both the cycles as two diodes are connected. Circuit diagram: Operation: 1. In ... both half-cycles of input AC voltage. Therefore DC is obtained across the load RL.

Description : In a full wave rectifier circuit using centre tapped transformer, the peak voltage across half of the secondary winding is 30 V. Then PIV is: (1) 30 V (2) 60 V (3) 15 V (4) 10 V

Last Answer : In a full wave rectifier circuit using centre tapped transformer, the peak voltage across half of the secondary winding is 30 V. Then PIV is: 60 V

Description : A separately excited d.c. motor fed from single phase full converter with firing angle 60° runs at 1000 r.p.m. If motor is connected to single phase semiconverter with the same firing angle of 60°, it would run at (a) 2000 rpm (b) 1850 rpm (c) 1500 rpm (d) 1000 rpm 

Last Answer : Ans =1500

Description : In a single-phase full converter, the number of SCRs conducting during overlap is   (a) 1 (b) 2 (c) 3 (d) 4 

Last Answer : 4

Description : single phase full converter

Last Answer : single phase full converter

Description : For a fixed beam with midpoint load point, maximum deflection at the centre is a.PL3/ 192EI b.PL2/ 48EI c.PL4/ 192EI d.PL3/ 48EI

Last Answer : a.PL3/ 192EI

Description : An `L-C-R` series circuit with `100Omega` resistance is connected to an `AC` source of `200V` and angular frequency `300rad//s`. When only the capacit

Last Answer : An `L-C-R` series circuit with `100Omega` resistance is connected to an `AC` source of `200V` and ... and the power dissipated in the `L-C-R` circuit

Description : An a.c series circuit has resistance of 10ohm, inductance of 0.1H and capacitance of 10µf, voltage applied to circuit is 200V. find (i) Resonant frequency (ii) Current at resonance (iii) Power at resonance 

Last Answer : Solution: For RLC series circuit

Description : If the no load voltage of a certain generator is 220V and the rated load voltage is 200V, then the voltage regulation is: a. 1% b. 10% c. 20V d. 9%

Last Answer : If the no load voltage of a certain generator is 220V and the rated load voltage is 200V, then the voltage regulation is: a. 1% b. 10% c. 20V d. 9%

Description : A lamp of 100W at 200V is supplied current at 100 volts. It will be equivalent to the lamp of:   a. 50W b. 40W c. 25W d. 10W 

Last Answer : A lamp of 100W at 200V is supplied current at 100 volts. It will be equivalent to the lamp of: 25W

Description : Two 100W, 200V lamps are connected in series across a 200V supply. The total power consumed by each lamp will be in Watts

Last Answer : 4800

Description : What are the advantages of single phase bridge converter over single phase mid-point converter?

Last Answer : a. SCRs are subjected to a peak-inverse voltage of 2Vm in a fully controlled bridge rectifier. Hence for same voltage and currnt ratings of SCrs, power handled by mid-point configuration is about ... load power. As such, the transformer rating in mid-point converter is double the load rating.

Description : A single phase fully controlled bridge converter supplies a load drawing constant and ripple free load current, if the triggering angle is 30o, the input power factor will be  (A) 0.65 (B) 0.78 (C) 0.85 (D) 0.866

Last Answer : A single phase fully controlled bridge converter supplies a load drawing constant and ripple free load current, if the triggering angle is 30o, the input power factor will be 0.78

Description : The no-load speed of a single-phase SCR bridge converter fed separately excited dc motor operating at a firing delay angle, α and flux, Φ (A) directly proportional to α and Φ (B) ... proportional to α and inversely proportional to Φ (D) directly proportional to Φ and inversely proportional to α

Last Answer : The no-load speed of a single-phase SCR bridge converter fed separately excited dc motor operating at a firing delay angle, α and flux, Φ directly proportional to α and inversely proportional to Φ

Description : What is a thyristor ? What are its uses ?

Last Answer : A thyristor is a special kind of semi conductor device that uses internal feedback to produce latching action. Use : Used for controlling large amounts of load power in motors, heaters, lighting systems etc ... the latches like a open switch. This latch will always stay in open or close position.  

Description : A d.c. voltage of 230 V is imposed on an unloaded 230 V, 50 Hz transformer, it will (A) give high secondary voltage (B) burn out (C) give secondary voltage as per k (D) None of these

Last Answer : A d.c. voltage of 230 V is imposed on an unloaded 230 V, 50 Hz transformer, it will burn out

Description : A two-winding single phase transformer has a voltage regulation of 4.5% at full-load and unity power-factor. At full-load and 0.80 power-factor lagging load the voltage regulation will be (A) 4.5%. (B) less than 4.5%. (C) more than 4.5%. (D) 4.5% or more than 4.5%.

Last Answer : (C) more than 4.5%.

Description : A single-phase, 50 kVA, 250 V/500 V two winding transformer has an efficiency of 95% at full load, unity power factor. If it is re-configured as a 500 V/750 V auto-transformer, its efficiency at its new rated load at unity power factor will be  (A) 95.752% (B) 97.851% (C) 98.276% (D) 99.241%

Last Answer : A

Description : A two -winding single phase transformer has a voltage regulation of 4.5% at full - load and unity power -factor. At full -load and 0.80 lagging power-factor, the voltage regulation will be: (A) 4.5% (B) less than 4.5% (C) more than 4.5% (D) none of the above

Last Answer : A two -winding single phase transformer has a voltage regulation of 4.5% at full - load and unity power -factor. At full -load and 0.80 lagging power-factor, the voltage regulation will be: more than 4.5%