Condenser type bushing

Porcelain type bushing 

Related questions

Description : What is the function of transformer bushing ?

Last Answer : Answer : The transformer is brought out of the tank by bushing at the winding terminals. These bushings are made of very fine porcelain. These are attached to the lid of the tank with a gasket ... the transformer winding. Their number , size and method of connection depend on the amount of voltage.

Description : införmation for pruning bushing bush

Last Answer : Burning bush (Euonymus alatus) is grown for its brilliant red fall foliage. Growing to heights of 9 to 12 feet, this bush may spread to an equivalent width. An ornamental shrub, hardy in U. S. ... to mature and may pose a risk of damage to tender new growth during the winter months. -Birdy

Description : In case of partial bearing, the angle of contact of the bushing with the journal is (A) 270° (B) More than 180° (C) Less than 180° (D) 360°

Last Answer : (C) Less than 180°

Description : In case of full journal bearing, the angle of contact of the bushing with the journal is (A) 60° (B) 90° (C) 180° (D) 360°

Last Answer : (D) 360°

Description : In case of partial bearing, the angle of contact of the bushing with the journal is usually (A) 120° (B) 180° (C) 45° (D) 360°

Last Answer : (A) 120°

Description : Threaded Bushing

Last Answer : What is a Threaded Bushing? First off, a threaded bushing is a helical or tapered bushing used to convert between rotational and linear movement or force. It connects threaded pipes ... installation, and therefore many municipal plumbing codes restrict the use of threaded plastic pipe fittings.

Description : Plastic Bushing

Last Answer : Plain bearings and sleeve bearings (also referred to as bushings or journal bearings) are used to constrain, guide or reduce friction in rotary or linear applications. They function via a sliding action ... plastic, and each having a flanged end for abutting the central opening of a wheel assembly.

Description : Aluminum Bushing

Last Answer : Aluminum bushings are usually utilized for relatively light, low-speed work compared to bearings, and are made from aluminum and alloy composites, depending on the frictional and mechanical ... are operating with oil clearances appreciably below those of equivalent bronze or Babbitt bearings.

Description : Aircraft Bushing

Last Answer : A typical bushing/plain bearing is a cylindrical lining designed to reduce friction and wear, or constrict and restrain motion of mechanical parts. One type of bushing is a hardened threaded ... high accuracy. Reliability, accuracy and smooth operation are paramount in most ball screw applications.

Description : Why we do 2 types of earthing on transformer i.e.: body earthing & neutral earthing, what is function. I am going to install a 5oo kva transformer & 380 kva DG set what should the earthing value?

Last Answer : The two types of earthing are Familiar as Equipment earthing and system earthing. In Equipment earthing: body (non conducting part) of the equipment should be earthed to safeguard the human ... earthing will be further classified into directly earthed, Impedance earthing, resistive (NGRs) earthing.

Description : How Many Types Of Colling System It transformer ?

Last Answer : ONAN (oil natural, air natural). ONAF (oil natural, air forced). OFAF (oil forced, air forced). ODWF (oil direct, water forced). OFAN (oil forced,air forced).

Description : What are the various types of three phase transformer connections?

Last Answer : The most common types of transformer connections are, i. Star-Star (Y-Y) ii. Delta-Delta(∆-∆) iii. Star-Delta (Y-∆) iv. Delta-Star (∆-Y) v. Open Delta (V-V) vi. Scott Connection (T-T)

Description : What are the different types of faults in a transformer?

Last Answer : The internal faults include phase faults, ground faults, inter-turn faults, tap-changer failure, and leakage oil from tank. The external faults include system phase faults, system ground faults, over loads and over fluxing.

Description : What are the types of oil used for in transformer for cooling? 

Last Answer : Paraffin based and naphtha based (in INDIA)  

Description : What are the types of cooling in transformer?

Last Answer : 1. Natural cooling. a. Air natural cooling (Dry type). b. Oil immersed natural cooling. c. Oil immersed, forced oil circulation with natural cooling. 2. Artificial cooling. a. Oil immersed forced ... This is the method of cooling combining oil natural, water, air natural, air blast and forced oil.

Description : What are the types of transformer core?

Last Answer : a. Core type transformer core. b. Shell type transformer core. c. Berry type transformer core. d. Spiral type transformer core.

Description : In conversion of 3-phase to 2-phase supply with T connection, the transformation ratio of the teaser will be__ times to that of main transformer: a) 1.732 b) 1.15 c) 0.866 d) Unity

Last Answer : Ans: C

Description : The harmonic currents in a power transformer does not cause increase in: a) Secondary voltage b) Core loss c) Copper loss d) Magnetic interference with protective relays

Last Answer : Ans: A

Description : An auto transformer is preferred over an ordinary two winding transformer due to: a) Safety of operation b) Availability of taps on secondary c) Copper savings d) All the above

Last Answer : Ans: C

Description : In a transformer, with closed magnetic coupling between primary and secondary __ will improve: a) Efficiency b) All day efficiency c) Regulation d) None of the above

Last Answer : Ans: C

Description : Booster transformer should never: a) Have fuse in the HV winding b) Be left open circuited c) Be left closed circuited d) None of the above

Last Answer : Ans: B

Description : The rating of the Transformer __ when the supply frequency is increased: a) Remains unchanged b) Increases c) Decreases d) None of the above

Last Answer : Ans: B

Description : Stones are provided in the substation to: a) To avoid fire accident by draining oil from transformer if leaks b) To avoid growing of weeds and plants c) To provide insulation d) All the above

Last Answer : Ans: D

Description : A transformer has negative voltage regulation when its load power factor is- (a) Zero (b) Unity (c) Leading (d) Lagging

Last Answer : Ans: C

Description : The electrical schematic illustrated in figure A, depicts a/an _____________. EL-0059 A. autotransformer B. Delta Wye transformer C. primary EMF generator D. potential transformer

Last Answer : Answer: D

Description : Which of the listed electrical devices is represented by the symbol shown in the illustration? EL-0055 A. Fixed resistance resistor B. Coil with magnetic core C. DC motor or generator shunt field D. Transformer

Last Answer : Answer: D

Description : The symbol shown as figure 'A' represents a/an ____________. EL-0059 A. transformer B. coil C. shunt field D. inductor

Last Answer : Answer: A

Description : The diagram shown in the illustration represents a/an _____________. EL-0082 A. stepup transformer B. magnetic amplifier C. autotransformer D. Scott-connected transformer

Last Answer : Answer: A

Description : In electric circuit schematics, a transformer is represented by which of the symbols shown in the illustration? EL-0059 A. A B. B C. C D. D

Last Answer : Answer: A

Description : Which of the following statements identifies the difference between the primary windings and the secondary windings of a 2:1 stepdown transformer? A. The secondary windings have twice as much resistance ... primary windings. D. The secondary windings have half as many turns as the primary windings.

Last Answer : Answer: D

Description : An open coil in a transformer will be indicated by which of the listed conditions? A. 'zero' resistance accompanied by high inductance B. no resistance accompanied by stray inductance C. infinite resistance in addition to no inductance D. infinite resistance in addition to normal inductance

Last Answer : Answer: C

Description : A load with an impedance of 440 ohms is connected across the secondary of the transformer illustrated. If the input voltage is 110 VAC and the step-up ratio is 10 to 1, what will be the primary current? EL-0055 A. 2.5 amps B. 25 amps C. 250 amps D. current cannot be determined with information given

Last Answer : Answer: B

Description : The turns ratio of transformer 'A' shown in the illustration is four to one and all taps are evenly spaced. If 120 volts were applied to terminals 'H1' and 'H3', what would appear at 'X1' and 'X2'? EL-0082 A. 15 volts B. 30 volts C. 480 volts D. 960 volts

Last Answer : Answer: A

Description : A load is connected to the secondary of the transformer illustrated and the current through the load is 10 amps. If the step-up ratio is 10 to 1 and the input voltage is 110 VAC, what will be the current flow through the primary? EL-0055 A. 1 amp B. 10 amps C. 100 amps D. 1000 amps

Last Answer : Answer: C

Description : Which of the following statements is true concerning stepdown transformer operation? A. The inductance on the primary side is the same as the inductance on the secondary side. B. The voltage to the primary ... . D. The voltage to the primary side is greater than the voltage from the secondary side.

Last Answer : Answer: D

Description : When a low input voltage is imparted to a device which then delivers a high output voltage, the device is known as a _____________. A. primary transformer B. secondary transformer C. stepdown transformer D. stepup transformer

Last Answer : Answer: D

Description : In the illustrated circuit, if the input to leads 'B' and 'Y' was 24 VDC the output between 'A' and 'X' will be _________. EL-0069 A. 24 VDC B. 22.8 VDC, 24 VDC minus the 1.2 VDC voltage drop across two diodes C. undeterminable without knowing the turns ratio of the transformer D. 0 VDC

Last Answer : Answer: D

Description : A device used in an electrical circuit to change alternating current to direct current, is known as a _____________. A. current transformer B. rectifier C. condenser D. shunt

Last Answer : Answer: B

Description : When used for taking resistance measurements, a volt-ohm-milliammeter is normally powered by _____________. A. a hand cranked generator B. internal storage batteries C. the current in the circuit being tested D. a step down transformer

Last Answer : Answer: B

Description : In the illustrated electronic governor, the circuit card connected to the potential and current transformers is for ________. EL-0046 A. increasing the signal strength to the governor to ... from motorization D. conditioning the load through the use of a magnetic amplifier current transformer

Last Answer : Answer: A

Description : The transistors in the illustrated circuit are connected using what type of coupling? EL-0049 A. RC coupling B. transformer coupling C. LC coupling D. direct coupling

Last Answer : Answer: B

Description : In the illustrated 450 VAC system, what should be provided between the bus and the device labeled 'F'? EL-0003 A. a potential transformer B. a current transformer C. an emergency disconnect device D. an audible alarm and indicating light

Last Answer : Answer: A

Description : The transistors in the illustrated circuit are connected using what type of coupling? EL-0048 A. RC coupling B. transformer coupling C. LC coupling D. direct coupling

Last Answer : Answer: A

Description : The transistors in the illustrated circuit are connected using what type of coupling? EL-0051 A. RC coupling B. transformer coupling C. impedance coupling D. direct coupling

Last Answer : Answer: D

Description : In replacing a defective transformer with a new one, which of the following actions must be carried out to insure proper operation of the equipment it serves? A. The secondary leads must be grounded ... magnetize it. D. The iron core must be grounded for 10 minutes to remove any residual magnetism.

Last Answer : Answer: B

Description : The transistors in the illustrated circuit are connected using what type of coupling? EL-0050 A. RC coupling B. transformer coupling C. Impedance coupling D. direct coupling

Last Answer : Answer: C

Description : When a fluorescent lamp has reached the end of its useful life, it should be replaced immediately, or the resultant flashing may _____________. A. blow the lamp's circuit breaker B. explode, ... fly in all directions C. short circuit the ballast transformer D. damage the starter and the ballast

Last Answer : Answer: D

Description : In a three-phase, open-delta connected transformer, the line current is equal to _____________. A. the phase current B. three times the phase current C. the sum of any two phase currents D. the difference of any two phase currents