How can you start-up the 40w tube light with 230v AC/DC without using any choke/Coil?

1 Answer

Answer :

It’s possible by means of Electronic choke. Otherwise it's not possible to ionize the particles in tube light, with normal voltage.

Related questions

Description : How can we start-up the 40w tube light with 230v AC/DC without using any choke/Coil?

Last Answer :  It is possible by means of Electronic choke. Otherwise it’s not possible to ionize the particles in tube. Light, with normal voltage.

Description : Two bulbs of 100w and 40w respectively are connected in series across a 230v supply which bulb will glow bright and why?

Last Answer : A:Since two bulbs are in series they will get equal amount of electrical current but as the supply voltage is constant across the bulb(P=V^2/R).So the resistance of 40W bulb is greater and voltage across 40W is more (V=IR) so 40W bulb will glow brighter.

Description : Two bulbs of 100w and 40w respectively connected in series across a 230v supply which bulb will glow bright and why?

Last Answer : Since two bulbs are in series they will get equal amount of electrical current but as the supply voltage is constant across the Bulb (P=V^2/R).So the resistance of 40W bulb is greater and voltage across 40W is more (V=IR) so 40W bulb will glow brighter.

Description : If 200w, 100 w and 60 w lamps connected in series with 230V AC , which lamp glow brighter? Each lamp voltage rating is 230V.

Last Answer :  Each bulb when independently working will have currents (W/V= I)  For 200 Watt Bulb current (I200) =200/230=0.8696 A  For 100 Watt Bulb current (I100) =100/230=0.4348 A  ... current through it. So minimum power dissipated across it as min current X equal Voltage across =s min power dissipation

Description : A short in the shunt field of a DC motor is best located by _____________. A. visual inspection of the commutator B. applying AC voltage to each field coil and measuring the voltage drop across ... using a growler and hacksaw blade D. isolating each coil from the others and using a megohmmeter

Last Answer : Answer: B

Description : An AC circuit consists of a resistance and a choke coil in series . The resistance is of 220 `Omega` and choke coils is of 0.7 H . The power abosorbed

Last Answer : An AC circuit consists of a resistance and a choke coil in series . The resistance is of 220 ` ... 50 Hz , source connected with the circuit , is

Description : The 'Choke' used with a tube light is basically – (1) an inductor (2) a capacitor (3) a transformer (4) a resistor

Last Answer : (1) an inductor Explanation: In electronics, a choke is an inductor used to block higher-frequency alternating current (AC) in an electrical circuit, while passing lower-frequency or direct ... created by suddenly interrupting the current in choke, which is connected in series with the tubelight.

Description : Why the choke is used with tube light?

Last Answer : Ans. Choke is used as inductance and check voltage surge at starting and limit the current in Running.

Description : The ‘Choke’ used with a tube light is basically (1) an inductor (2) a capacitor (3) a transformer (4) a resistor

Last Answer : an inductor

Description : When using a megohmmeter to determine which shunt field coil is grounded in a DC machine, you must ____________. A. insulate the field frame from the ship's hull B. disconnect each shunt ... C. use a motor driven high capacity megohmmeter D. remove all main line lead connections before testing

Last Answer : Answer: B

Description : One method of testing for a reversed shunt field coil in a DC generator or motor is by connecting the field to a direct current source, at reduced field rated voltage, and test for ... placed near each field C. test lamp across adjacent fields D. copper jumper across the interpole connections

Last Answer : Answer: B

Description : Aboard ship, a grounded field coil in an AC motor can be determined by using a _________________. A. portable growler B. galvanometer C. visual inspection D. megohmmeter

Last Answer : Answer: D

Description : Fluorescent tubes are fitted with a choke. What does the choke coil? -Do You Know?

Last Answer : answer:

Description : Fluorescent tubes are fitted with a choke. What does the choke coil?

Last Answer : Reduces current in the circui

Description : When an AC or a DC motor fails to start, the FIRST step in troubleshooting should be to check the ____________. A. motor windings for obvious opens B. motor controller leads for continuity C. fuse or circuit breaker D. motor controller leads for grounds

Last Answer : Answer: C

Description : One of the following is a possible cause of an abrupt frequency variation in a self exited transmitter oscillator circuits resulting to a poor frequency stability to hold a constant frequency ... capacitor in the oscillator D. Loose connections in the oscillator, amplifier, or antenna circuits.

Last Answer : D. Loose connections in the oscillator, amplifier, or antenna circuits.

Description : The device shown in the illustration is a/an ____________. EL-0083 A. noise filtering choke B. autotransformer C. fluorescent light ballast D. power factor correction inductor

Last Answer : Answer: B

Description : What happen if we give 220 volts dc supply to the bulb or tube light?

Last Answer : Bulbs [devices] for AC are designed to operate such that it offers high impedance to AC supply. Normally they have low resistance. When DC supply is applied, due to low resistance, the current through lamp would be so high that it may damage the bulb element.

Description : What Happen If We Give 220 Volts Dc Supply To D Bulb R Tube Light?

Last Answer : Bulbs [devices] for AC are designed to operate such that it offers high impedance to AC supply. Normally they have low resistance. When DC supply is applied, due to low resistance, the current through lamp would be so high that it may damage the bulb element.

Description : what happens if we give 220 volts dc supply to the bulb or tube light?

Last Answer : A:Bulbs [devices] for AC are designed to operate such that it offers high impedance to AC supply. Normally they have low resistance. When DC supply is applied, due to low resistance, the current ... be so high that it may damage the bulb element. Low dc voltage will not damage the appliances

Description : What happen if we give 220 volts dc supply to bulb or tube light?

Last Answer : Bulbs or devices for AC are designed to operate such that it offers high impedance to AC supply. Normally they have low resistance. When DC supply is applied, due to low resistance, the current through lamp would be so high that it may damage the bulb element.

Description : An ideal choke takes a current of 8A when connectd to an AC source of 100V and 50 Hz. A pure resistor under the same condition strikes a current of 10

Last Answer : An ideal choke takes a current of 8A when connectd to an AC source of 100V and 50 Hz. A pure ... resistor and inductor `sqrt(10x)`A. Find value of x

Description : Is it okay to shoot 12 gauge slugs out of a barrel with a modified choke tube in it?

Last Answer : Trenchcoat mafia? Of course it’s okay, try it out… let me know how it goes…

Description : Draw the wiring diagram of fluorescent tube. Explain the working of choke and starter. 

Last Answer : Fluorescent lamp:- Operation:- When switch is ON current flows through the choke-filament no1- starter-filament no. 2- to neutral, At that time choke induces high voltage which is applied to ... at the time of starting. ii) Starter: To make and break the circuit to start the tube. 

Description : The purpose of a choke in a fluorescent tube is (A) To decrease the current (B) To increase the current (C) To decrease the voltage momentarily (D) To increase the voltage momentarily

Last Answer : The purpose of a choke in a fluorescent tube is To increase the voltage momentarily

Description : Shading coils are installed on AC full-voltage starters to _____________. A. eliminate contact chatter B. dissipate opening contact arcs C. delay current build up in the holding coil D. protect the motor windings from momentary starting current overload

Last Answer : Answer: A

Description : Which of the listed electrical devices is represented by the symbol shown in the illustration? EL-0055 A. Fixed resistance resistor B. Coil with magnetic core C. DC motor or generator shunt field D. Transformer

Last Answer : Answer: D

Description : If a DC motor runs faster than designed, with all other conditions being normal, the possible cause could be a/an ______________. A. shorted shunt field coil B. open armature coil C. reversed commutating pole D. overload

Last Answer : Answer: A

Description : A shorted armature coil in a DC motor can be detected by _____________. A. sparking at the brushes B. shiny armature coil C. worn grooves in the armature D. undercut mica

Last Answer : Answer: A

Description : An open armature connection in a DC propulsion motor could be caused by ____________. A. low-load operation B. clogged ventilation ducts C. sparking at the brushes D. a grounded shunt field coil

Last Answer : Answer: B

Description : A flickering ground detection lamp on a DC system would indicate a _____________. A. multiple-ground condition in the distribution system B. ground in an armature coil of an operating machine C. ground in a motor accompanied with a short D. short between two adjacent bars of the generator commutator

Last Answer : Answer: B

Description : To limit the current flow through a DC voltmeter to as low a value as possible, the moving coil circuit is provided with a/an _____________. A. high series resistance B. high parallel resistance C. series inductor D. external shunt

Last Answer : Answer: A

Description : Temporary repairs to an open DC propulsion armature coil can be made by _____________. A. connecting the coil ends directly to a pair of negative brushes B. disconnecting coil ends, insulating ... C. grounding the coil ends and short circuiting the commutator bar D. removing the sparking brushes

Last Answer : Answer: B

Description : If a transformer is connected to a DC source, the transformer will overload at the ____________. A. contacts B. primary coil C. secondary coil D. core

Last Answer : Answer: B

Description : The simplest method of controlling the terminal voltage of compound-wound DC generator is with a _____________. A. hand-operated field rheostat connected in series with the shunt field circuit B. ... in series with the load D. balance coil diverting neutral current through the shunt field

Last Answer : Answer: A

Description : DC relay coil or contactor coils must be connected to which side?

Last Answer : Negative side of the DC supply to avoid galvanic effect on the coil, which will corrode the coil.  

Description : Three factors responsible for the change in voltage as load is applied to an AC generator are: 1) the drop in resistance in the armature circuit, 2) the change in flux, and 3) the ____________. A. armature winding speed B. inductance load drop C. coil pitch factor D. armature reactance voltage drop

Last Answer : Answer: D

Description : If two AC generators have just been placed in parallel, the true power load is initially distributed evenly by _____________. A. a balance coil B. changing field excitation C. adjusting the governor control settings D. a rheostat

Last Answer : Answer: C

Description : The leads from a megohmmeter are attached to the leads of an AC motor field coil. A reading of infinity is obtained indicating a/an ____________. A. open field coil B. shorted field coil C. grounded field coil D. shunted field coil

Last Answer : Answer: A

Description : In an AC circuit, the inductive reactance of a coil varies with the _______________. A. resistance of the circuit B. frequency of the circuit C. voltage of the circuit D. current of the circuit

Last Answer : Answer: B

Description : Excessive humming of AC contactors may be caused by ______________. A. burnt arc shields B. shorted armature coils C. a broken shading coil D. high voltage

Last Answer : Answer: C

Description : A loud buzzing noise in an AC controller is probably caused by _____________. A. poor contact with the overload relay B. an incorrectly sized heater C. a broken shading coil D. abnormal starting current

Last Answer : Answer: C

Description : Which of the following methods should be used to test for an 'open' coil in an AC motor stator? A. Test with an ohmmeter, one test lead on the shaft, and the other test lead to the stator leads ... an open coil. D. Use a growler, listening for noise and vibration to increase when over an open coil.

Last Answer : Answer: B

Description : A testing device called a 'growler' is being used to locate a shorted coil in the stator of an AC electrical machine. When the 'feeler' is moved over a slot containing the shorted coil _____________. ... . the meter needle will be deflected to zero D. the meter needle will be deflected to full-scale

Last Answer : Answer: A

Description : A shading coil used in an AC magnetic controller, functions to _____________. A. reduce vibration and noise in the contactor B. prevent flux buildup in the operating coil C. eliminate arcing when the contacts close D. energize the operating coil and 'pull in' the contacts

Last Answer : Answer: A

Description : Regarding an AC generator connected to the main electrical bus; as the electric load and power factor vary, a corresponding change is reflected in the generator armature reaction. These changes in ... . governor speed droop setting B. voltage regulator C. balance coil D. phase-balance relay

Last Answer : Answer: B

Description : I remember that in times of 220V, tol was allowed. +/- 10%. After switching to 230V, this no longer applies - what are the current limits? And for the 'witnesses' - from which date did the change from 220 to 230V take place? Thank you.

Last Answer : The normalized rated voltage Un for the public low voltage network is Un = 230 V between phase and node. The voltage deviation should not exceed 10%. Under normal operating conditions, during each week, 95% of ... of the customer's supply equipment. The change I think was just 1,1,2008

Description : Blackt Electrotech 230V 24x7 Energy Saving Socket Type Digital Programmable Plastic Electronic Timer (White)

Last Answer : Buy from amazon: https://amzn.to/2SUTSdv Buy: http://bit.ly/2ZqlAkS

Description : what city has these coorinates 23s 40w?

Last Answer : Abkhazia - Republic of Abkhazia List of cities in Afghanistan - Islamic Republic of Afghanistan List of cities in Albania - Republic of Albania List of cities in Algeria - People's Democratic Republic ... cities in the Bahamas - Commonwealth of The Bahamas List of cities in Bahrain - Kingdom of

Description : What city has these coordinates 23s 40w?

Last Answer : Brazil