Description : The frequency output of an operating alternator is controlled by the _____________. A. relative speed of the rotor poles B. number of turns of wire in the armature coil C. strength of the magnets used D. output voltage
Last Answer : Answer: A
Description : One factor that determines the frequency of an alternator is the ____________. A. number of turns of wire in the armature coil B. number of magnetic poles C. strength of the magnets used D. output voltage
Last Answer : Answer: B
Description : What is the frequency of the output voltage of an alternator with four poles that is rotated at 3600 rpm?
Last Answer : 120 Hz.
Description : The output voltage of a 440 volt, 60 hertz, AC generator is controlled by the _____________. A. prime mover speed B. exciter output voltage C. load on the alternator D. number of poles
Description : The speed of a multi-speed, squirrel-cage, induction motor operating in a fixed frequency system can be changed by _____________. A. reconnecting stator windings for different numbers of poles B. ... sequence of the applied voltage D. reconnecting the stator so that no poles have the same polarity
Description : The output voltage of a three-phase alternator is regulated by the _____________. A. AC voltage to the armature B. AC voltage to the field C. DC voltage to the armature D. DC voltage to the field
Last Answer : Answer: D
Description : The division of kilowatt load between two paralleled alternators is determined by the _____________. A. amount of field excitation to the leading machine B. load-speed characteristics of the governors C. amount of field excitation to the lagging machine D. number of field poles per alternator
Description : A synchronous motor maintains synchronism with the rotating field because _____________. A. field strength varies directly with rotor slip B. DC current applied to the rotor coils causes the rotor ... the flux created by the excitation current D. the stator flux rotates in the opposite direction
Description : The amount of voltage induced in the windings of an AC generator depends mainly on _____________. A. the number of field poles energized B. the speed at which the stator windings rotate through the magnetic field C. the strength of the magnetic field D. all of the above
Last Answer : Answer: C
Description : The most practical method of controlling the RPM of a step-speed AC motor is to _____________. A. change input voltage B. vary the number of poles C. vary power factor D. change the number of brushes
Description : True or False The strength of the magnetic poles in an electromagnet decreases with an increase in the number of turns of wire and the current flowing through them.?
Last Answer : FALSE
Description : An electrical device which employs a stationary armature and a rotating electromagnetic field is used aboard ship as a ____________. A. magnetic amplifier B. ship's service alternator C. three-wire DC generator D. saturable core reactor
Description : A change in field excitation of an alternator operating in parallel will cause a change in its _____________. A. alternator frequency B. kilowatt load C. voltage output D. all of the above
Description : The standard method of controlling the output voltage of a 440 volt, 60 Hz, AC generator is accomplished by adjusting the ____________. A. prime mover speed droop B. number of poles C. alternator field excitation D. load on the alternator
Description : The purpose of a main switchboard circuit breaker's reverse-power trip is to _____________. A. prevent main circuit overload B. protect the circuit breaker blowout coil C. prevent alternator motorization D. prevent low voltage tripout
Description : The cycles per second developed by the alternator aboard your vessel is determined by _____________. A. the speed of the engine driving the alternator B. the resistance applied to the field rheostat C. the synchronous speed of induction D. the adjustments made to the voltage regulator
Description : The most practical way to control the voltage output of an AC generator is to vary the _____________. A. number of windings B. speed of the rotating field C. strength of the rotating magnetic field D. power factor of the load
Description : When troubleshooting a motor controller, all indications are that a relay coil should be energized. If there were no magnetic pull, with rated voltage measured across the coil, the most probable cause ... open C. auxiliary contact in series with the coil is defective D. relay armature is stuck
Description : An AC circuit has capacitance arranged in series. If the line voltage remains constant, the capacitive reactance value can be varied by changing the _____________. A. line frequency B. resistance C. number of commutating poles D. number of interpoles
Description : The voltage output of an AC generator is accurately controlled by _____________. A. changing the sensitivity of the prime mover to large changes in voltage B. varying the reluctance of the air gap C. varying the DC exciter voltage D. shorting out part of the armature windings
Description : The frequency of an alternator is controlled from the main switchboard by adjusting the _____________. A. frequency meter B. voltage regulator C. governor control D. sychroscope switch
Description : The synchronous speed for a 3 phase 6-pole induction motor is 1200 rpm. If the number of poles is now reduced to 4 with the frequency remaining constant, the rotor speed with a slip of 5% will be _________. (A) 1690 rpm (B) 1750 rpm (C) 1500 rpm (D) 1710 rpm
Last Answer : (D) 1710 rpm
Description : A 3 phase 50 Hz induction motor has full load speed of 970 rpm. Calculate no of poles and slip frequency.
Last Answer : The number of poles in an induction motor can be calculated using the following formula: No. of poles = (120 * frequency) / speed In this case, the number of poles would be calculated as follows: No. of poles = ( ... ) - 50 Hz = 8.08 Hz So the motor has 6 poles and a slip frequency of 8.08 Hz.
Description : If the synchronous speed of a 12 pole, polyphase, induction motor operating at 60 Hz were 600 RPM, how many poles will be required in a similar motor operating at the same frequency but having a synchronous speed of 900 RPM? A. 4 B. 6 C. 8 D. 18
Description : The speed of a squirrel cage induction motor is determined by the _____________. A. diameter of the stator B. number of stator poles C. rotor winding resistance D. bar resistance of the conducting rotor
Description : Basic electrical motor action depends on _______________. A. a conductor rotated within a magnetic field B. a current carrying conductor placed in a magnetic field C. the relative force of the commutator and commutating poles D. the relative force of the armature and interpoles
Description : The function of the commutator in a DC motor is to ________. A. reverse the flow of current through the armature B. reverse the flow of current in the field poles C. reduce the reluctance of the magnetic path through the motor D. shift the neutral running plane of the brushes to prevent sparking
Description : The spring constant of a helical compression spring does not depend on a. Coil diameter b. Material strength c. Number of active turns d. wire diameter
Last Answer : b. Material strength
Description : A shorted armature coil in a DC motor can be detected by _____________. A. sparking at the brushes B. shiny armature coil C. worn grooves in the armature D. undercut mica
Description : The electrical device shown in the illustration is a/an _____________. EL-0077 A. operating coil B. indicating lamp C. motor armature D. potentiometer
Description : A flickering ground detection lamp on a DC system would indicate a _____________. A. multiple-ground condition in the distribution system B. ground in an armature coil of an operating machine C. ground in a motor accompanied with a short D. short between two adjacent bars of the generator commutator
Description : Temporary repairs to an open DC propulsion armature coil can be made by _____________. A. connecting the coil ends directly to a pair of negative brushes B. disconnecting coil ends, insulating ... C. grounding the coil ends and short circuiting the commutator bar D. removing the sparking brushes
Description : If a magnetic controller contactor fails to pick up when the coil voltage is applied to the contactor coil, the cause may be _____________. A. overload B. misalignment of the affected contactor contacts C. low spring pressure D. an open contactor coil
Description : Magnetic controller contacts may become welded together during operating conditions as a result of _____________. A. high spring pressure B. high ambient temperature C. an open coil D. low voltage on operating coil
Description : When troubleshooting a magnetic controller, it is found that the contacts are welded together. The most probable cause is _____________. A. excessive operation at low load B. high ambient temperature C. low voltage on the operating coil D. high voltage on the operating coil
Description : If a magnetic controller relay fails to drop out when the coil voltage is removed from the relay, the probable cause may be _____________. A. excessive spring tension B. overvoltage C. excessive current D. welded contacts
Description : The main difference between a motor control circuit containing low voltage protection and low voltage release is that the latter contains _____________. A. a magnetic operating coil B. normally open line contacts C. thermal-overload protection D. a momentary-contact start button
Description : The division of kilowatt load between two paralleled alternators is determined by the _____________. A. amount of field excitation of the leading machine B. load-speed characteristics of the governors C. amount of field excitation to the lagging machine D. type of alternator
Description : A coil of wire is placed in a changing magnetic field. If the number of turns in the coil is decreased, the voltage induced across the coil will: A. increase B. decrease C. remain constant D. be excessive
Last Answer : A coil of wire is placed in a changing magnetic field. If the number of turns in the coil is decreased, the voltage induced across the coil will: decrease
Description : The synchronous speed of an induction motor is the ________. A. speed at which the rotor turns B. speed of the rotating field C. frequency of the rotor current D. slip in per cent of rotor RPM
Description : E.M.F for a coil depends upon A. the cross sectional area B. no. of turns of wire C. the magnitude of magnetic flux density D. all of above
Last Answer : all of above
Description : In an AC synchronous motor electric propulsion plant, propeller speed is controlled by varying the _____________. A. prime mover speed B. electric coupling field strength C. number of energized main motor poles D. propulsion generator field strength
Description : If many turns of an alternating current coil for a contactor become short circuited, the coil _____________. A. will continue to operate B. will probably burn out immediately C. will operate on reduced current D. temperature will drop
Description : If many turns of an alternating current coil for a contactor become short circuited, the coil _____________. A. temperature will drop B. will probably burn out immediately C. will continue to operate D. will operate on reduced current
Description : Three factors responsible for the change in voltage as load is applied to an AC generator are: 1) the drop in resistance in the armature circuit, 2) the change in flux, and 3) the ____________. A. armature winding speed B. inductance load drop C. coil pitch factor D. armature reactance voltage drop
Description : Excessive humming of AC contactors may be caused by ______________. A. burnt arc shields B. shorted armature coils C. a broken shading coil D. high voltage
Description : A low voltage source is being used for testing armature coils. A coil short circuit will be indicated by a _______. A. high voltage reading, while the other coil readings will have an ... the other coil readings are steady D. steady voltmeter reading, while the other coil readings are fluctuating
Description : Regarding an AC generator connected to the main electrical bus; as the electric load and power factor vary, a corresponding change is reflected in the generator armature reaction. These changes in ... . governor speed droop setting B. voltage regulator C. balance coil D. phase-balance relay
Description : Which of the following statements is true concerning all three-phase alternators? A. Each has three separate but identical armature windings acted on by one system of rotating magnets. B. Each has one ... The three phases always provide power to the load through three sets of slip rings and brushes.
Description : The conversion of the throttle command voltage to the signal necessary to achieve the desired shaft RPM is accomplished by the _____________. A. ahead or astern function generator of the ... circuit C. operational amplifiers in the autorotation circuit D. long time constant amplifier circuit