Vessel pitch can be controlled by either the 'bridge or engine room thrust lever' shown in the illustration; but only with one engine on the line whether in 'cruise or maneuver' mode. The cause is most likely a faulty relay _____________.  EL-0095 A. #1 B. #2 C. #3 D. #4

1 Answer

Answer :

Answer: D

Related questions

Description : A faulty 'function generator' shown in the illustration may prevent _____________. EL-0095 A. proper pitch control from both the 'bridge' and 'engine room thrust levers' B. the 'split potentiometer ... control pitch C. the pitch meter from indicating accurately D. relays #2 and/or #3 from energizing

Last Answer : Answer: A

Description : As shown in the two illustrations for 'pitch control' and engine speed control', when the plant is in 'AUTO / CRUISE' propeller pitch is controlled by ___________. EL-0095 A. the 'trim potentiometer' and ... and speed by its 'trim pot'. D. either 'thrust lever' and speed by the 'trim potentiometer'

Last Answer : Answer: D

Description : Considering the function of the circuit shown in the illustration, what is the purpose of supplying the thrust lever potentiometers with both (+) and (-) 15 volts? EL-0095 A. To select which ... alternate voltage supply if the other fails. D. So as to automatically select the position of Relay #

Last Answer : Answer: B

Description : If Relay #5 changed contact position grounding the 'auto' input to the 'pitch controller module', pitch control would be effected by the _________________. EL-0095 A. pitch feedback potentiometer B. Engine room thrust split potentiometer C. Engine room thrust lever only D. Bridge thrust lever only

Last Answer : Answer: B

Description : In the pitch control diagram shown in the illustration, what are the present plant operating conditions? EL-0095 A. One engine is on the line, cruise mode is selected and the engine room is in control. ... . D. Both engines are on line, maneuvering mode is selected and the engine room is in control.

Last Answer : Answer: D

Description : The meter indicating the position of the 'bridge Thrust lever' shown in the illustration is located ___________________. EL-0095 A. in the Engine Control Room B. on the Bridge C. in the Captain's office D. in the Chief Engineer's office

Last Answer : Answer: A

Description : As shown in the illustration, the circuit which 'shapes' the linear output of the thrust lever so that the steady-state ship speed is linear with respect to that lever's setting is the _____________. EL-0095 A. 'pitch controller' B. 'error amplifier' C. 'function generator' D. 'servo amplifier'

Last Answer : Answer: C

Description : What are the plant conditions existing in the 'engine speed control' diagram shown in the illustration? EL-0096 A. The Bridge is in control in the 'auto. maneuver' mode. B. The Engine Room is in control in ... in the 'auto. split' mode. D. The Engine Room is in control in the 'auto. maneuver' mode.

Last Answer : Answer: D

Description : As shown in the illustration, a 'pitch cutback' feature is incorporated in the system. This circuit reduces pitch amount to prevent engine overload when it senses ____________. EL-0095 A. pitch error of ... servo' C. excessive propeller speed or fuel to either engine D. only one engine on the line

Last Answer : Answer: C

Description : The 'pitch controller module' shown in the illustration is fed the actual pitch position of the propeller from the _____________. EL-0095 A. 'pitch meter' B. 'pitch feedback potentiometer' C. #5 relay position D. pitch error signal

Last Answer : Answer: B

Description : If someone were to write a biography about us, the following could be reported: #1 - Every basketball player needs a good one. #2 - we can be seen on most Christmas trees. #3 - One of us is ... accompany a line and a sinker. Based on the biographical information above --- Who/what are we? -Riddles

Last Answer : We are Hooks/hook.

Description : If someone were to write a biography about us, the following could be reported: #1 - A golfer faces many of us when playing 18 holes. #2 - we are frequently served with fish. #3 - On T. V. ... hands on us as often as possible. Based on the biographical information above --- Who/what are we? -Riddles

Last Answer : The biography of Chips.

Description : If someone were to write a biography about us, the following could be reported: #1 - We are always present in multiple-choice exams. #2 - Sherlock Homes kept a close eye on us after he retired. #3 - ... in reality, one of us. Based on the biographical information above --- Who/what are we? -Riddles

Last Answer : We are Bs, Bees, or Beas (as in Aunt Bea and actress Bea Benaderet.)

Description : As shown in the illustration, when the 'speed control' system is in 'SPLIT' _______________. EL-0096 A. Relays #1, #5 and #8 are not used B. the 'slew rated controller' is grounded through Relay ... E/P converters' are bypassed and air is fed directly to the governors via the 'load sharing valve'

Last Answer : Answer: C

Description : If fuse #1 shown in the illustration is defective, a voltage tester connected across points 'C' and 'B' will ____________. EL-0062 A. show a reading of 55 volts B. show full line voltage ... C. give positive indication that fuse #2 is good D. give positive indication that fuse #1 is defective

Last Answer : Answer: D

Description : Before servicing the device indicated as 'A' in panels #1 and #3 of the illustration, the device labeled 'CT' must __________. EL-0003 A. have the disconnected leads taped to prevent ... D. have one lead grounded to discharge static electricity for the prevention of damage to electronic components

Last Answer : Answer: C

Description : Diesel generators #1 and #2 are operating in parallel at near full load capacity. Diesel generator #1 suddenly trips out mechanically due to low lube oil pressure. The reverse power relay functions ... all nonvital circuits. D. Secure alarms, reset reverse power relay, and restart #1 engine.

Last Answer : Answer: C

Description : The 'function generator' of the control circuit illustrated _______________. EL-0095 A. can be programmed to produce a non-linear output for a linear input depending on operating conditions B. is used for ... which or how many engines are needed for a required vessel speed D. all of the above

Last Answer : Answer: A

Description : The motor starts when the start button in the illustration is pushed, but stops when the button is released the trouble is _________. EL-0007 A. the incorrect thermal overload coil B. a faulty 'M' coil C. a dirty contact on the Disc.Sw. at 'L3' D. a faulty holding relay contact

Last Answer : Answer: D

Description : Which plant parameters shown in the illustration would produce an alarm if they exceeded preset values? EL-0094 A. SME #7 CYL. EXH. and L.O. TO RDCN. GR. B. L.O. PRESS. TO MN. ENG. and PME #3 MN. BRG. C. L.O. PRESS. TO MN. ENG. and L.O. TO RDCN. GR. D. PME #3 MN. BRG. and SME #7 CYL. EXH.

Last Answer : Answer: D

Description : Which plant parameters shown in the illustration would produce an alarm if they fell below preset values? EL-0094 A. SME #7 CYL. EXH. and L.O. PRESS. TO RDCN. GR. B. L.O. PRESS TO MN. ENG. and PME #3 MN. BRG. C. ... . TO MN. ENG and L.O. PRESS. TO RDCN. GR. D. PME #3 MN. BRG. and SME #7 CYL. EXH.

Last Answer : Answer: C

Description : A vessel is equipped with two ship's service generators. Generator #1 is rated at 900 kw and generator #2 is rated at 600 kw. During parallel operation, with a hotel load of 1,000 kw, what should be the kw load on generator #2? A. 100 kw B. 400 kw C. 500 kw D. 600 kw

Last Answer : Answer: B

Description : Power necessary to operate the horn shown in the illustration _____________. EL-0093 A. comes from each station's magneto B. is supplied from a 115 volt source C. is conducted through a relay coil D. also lights lamps 'R' and 'T'

Last Answer : Answer: B

Description : As shown in the illustration, once the "LV" relay is energized for operation, what contacts must remain closed to maintain the "LV" relay energized when the control lever is moved away from the "off" or "stop" ... . B. Reset contacts. C. Upper set of "LVa" contacts. D. Lower set of "LVa" contacts.

Last Answer : Answer: C

Description : Component 'B' of section 'I' shown in the illustration represents a _____________. EL-0093 A. bridge rectifier B. selsyn motor C. small generator D. shielded lamp

Last Answer : Answer: C

Description : RC time constant characteristics, as shown in the illustration, are important in _____________. EL-0086 A. bridge rectifiers for alternator excitation B. timing and pulse shaping circuits C. transistor power amplifier biasing D. motor controller overload protection

Last Answer : Answer: B

Description : In order to determine whether or not 'fuse 2' shown in the illustration is defective, you should connect the voltage tester leads across points _____________. EL-0062 A. AC B. AD C. BC D. BD

Last Answer : Answer: B

Description : In order to determine whether or not 'Fuse 1', shown in the illustration is defective, you should connect the voltage tester leads across points _____________. EL-0062 A. AC B. AD C. BC D. BD

Last Answer : Answer: C

Description : If a voltage tester is being used to check for defective fuses in the circuit, shown in the illustration, which of the readings will indicate that fuse #2 is open? EL-0062 A. C-B full voltage B. A-D full voltage C. A-D no voltage D. C-B no voltage

Last Answer : Answer: C

Description : The winch shown in the illustration operates in any of the positions with the master switch in the 'lower' direction, but will not 'hoist' in any of the master switch hoist positions. Which of the listed faults ... '2M' in the power circuit may be badly corroded. D. Series relay 'FR' may be open.

Last Answer : Answer: A

Description : What type of service is NOT provided by the circuit shown in the illustration? EL-0094 A. Logging of engine order signals from the bridge. B. Printed record of alarms as they ... . Visual metering of temperature and pressure conditions. D. Periodic recording of pressure and temperature conditions.

Last Answer : Answer: A

Description : The vertical dotted line connecting the small circular symbols at coordinates '05L', '09L', '13L', '21L', '25L', etc., shown in the illustration, indicate that all _______________. EL-0100 A. contacts are ... board 'TB2' C. wires are grounded at both ends of the line D. wires have a common shield

Last Answer : Answer: B

Description : In an emergency, the fastest way to interrupt power and stop the winch shown in the illustration is for the ____________. EL-0102 A. mate to open the disconnect switch at 'L1' and 'L2' B. ... watch engineer to open the winch circuit breaker D. electrician to open the test link at the controller

Last Answer : Answer: B

Description : When a console indicating lamp burns out, attempts to renew it should not be made while maneuvering because _______________. A. the new lamp may be of a higher wattage and cause heat damage to the lens ... D. a socket/wiring fault may cause a ground or short circuit to shut down a vital function

Last Answer : Answer: D

Description : Moving the rheostat handle shown in the illustration, that is used to control a DC generator, towards the 'raise' direction will increase the _____________. EL-0030 A. field resistance B. armature resistance C. armature speed D. line voltage

Last Answer : Answer: D

Description : The device at coordinates '63/1' in the illustration represents a/an _____________. EL-0100 A. A.C. buzzer B. A.C. motor C. D.C. motor D. D.C. relay coil

Last Answer : Answer: D

Description : The schematic diagram shown in the illustration uses symbol 'A' to represent a/an _________. EL-0011 A. non-renewable fuse link B. circuit breaker coil C. overload relay coil D. thermal overload heater

Last Answer : Answer: D

Description : When an operating motor is connected to the controller shown in the illustration, the a path of current flow through the circuit is ____________. EL-0010 A. 'L1', stop button, start button, coil 'CR', 'L2' B. 'L1' ... L2' D. 'L1', stop button, start button, 'CR' contact, 'M' contact, 'CR' coil, 'L2'

Last Answer : Answer: B

Description : As shown in the illustration, what is responsible for maintaining the "LV" relay energized when the master switch handle is moved away from the "off" position? EL-0102 A. "DBa" contact. B. Reset contacts. C. Upper set of "LVa" contacts. D. Lower set of "LVa" contacts.

Last Answer : Answer: C

Description : Which component is responsible for energizing solenoid 'B1-B2' and releasing the brake for the winch motor shown in the illustration? EL-0102 A. Contactor '3M' B. A spring not shown in the schematic diagram C. Resistor 'B2-R1' D. Relay 'FR-B.O.'

Last Answer : Answer: A

Description : The contacts operated by the D.C. relay coil shown in the illustration are located in the schematic diagram prints at coordinates ____________. EL-0100 A. '41Y' on this page B. '52M52M' and '52H35M' C. '57R' on this page D. '52N' on page '57R'

Last Answer : Answer: C