Description : A faulty 'function generator' shown in the illustration may prevent _____________. EL-0095 A. proper pitch control from both the 'bridge' and 'engine room thrust levers' B. the 'split potentiometer ... control pitch C. the pitch meter from indicating accurately D. relays #2 and/or #3 from energizing
Last Answer : Answer: A
Description : Considering the function of the circuit shown in the illustration, what is the purpose of supplying the thrust lever potentiometers with both (+) and (-) 15 volts? EL-0095 A. To select which ... alternate voltage supply if the other fails. D. So as to automatically select the position of Relay #
Last Answer : Answer: B
Description : Vessel pitch can be controlled by either the 'bridge or engine room thrust lever' shown in the illustration; but only with one engine on the line whether in 'cruise or maneuver' mode. The cause is most likely a faulty relay _____________. EL-0095 A. #1 B. #2 C. #3 D. #4
Last Answer : Answer: D
Description : If Relay #5 changed contact position grounding the 'auto' input to the 'pitch controller module', pitch control would be effected by the _________________. EL-0095 A. pitch feedback potentiometer B. Engine room thrust split potentiometer C. Engine room thrust lever only D. Bridge thrust lever only
Description : As shown in the two illustrations for 'pitch control' and engine speed control', when the plant is in 'AUTO / CRUISE' propeller pitch is controlled by ___________. EL-0095 A. the 'trim potentiometer' and ... and speed by its 'trim pot'. D. either 'thrust lever' and speed by the 'trim potentiometer'
Description : As shown in the illustration, the circuit which 'shapes' the linear output of the thrust lever so that the steady-state ship speed is linear with respect to that lever's setting is the _____________. EL-0095 A. 'pitch controller' B. 'error amplifier' C. 'function generator' D. 'servo amplifier'
Last Answer : Answer: C
Description : In the pitch control diagram shown in the illustration, what are the present plant operating conditions? EL-0095 A. One engine is on the line, cruise mode is selected and the engine room is in control. ... . D. Both engines are on line, maneuvering mode is selected and the engine room is in control.
Description : The 'pitch controller module' shown in the illustration is fed the actual pitch position of the propeller from the _____________. EL-0095 A. 'pitch meter' B. 'pitch feedback potentiometer' C. #5 relay position D. pitch error signal
Description : The potentiometers shown in the illustration are supplied with both (+) and (-) voltages as well as a reference to ground ________________. EL-0095 A. so there is always a spare power ... , the other for relay operation and the potentiometers are in positions where they can be accidentally touched
Description : As shown in the illustration, a 'pitch cutback' feature is incorporated in the system. This circuit reduces pitch amount to prevent engine overload when it senses ____________. EL-0095 A. pitch error of ... servo' C. excessive propeller speed or fuel to either engine D. only one engine on the line
Description : What are the plant conditions existing in the 'engine speed control' diagram shown in the illustration? EL-0096 A. The Bridge is in control in the 'auto. maneuver' mode. B. The Engine Room is in control in ... in the 'auto. split' mode. D. The Engine Room is in control in the 'auto. maneuver' mode.
Description : As shown in the illustrations of console schematic diagrams, each circuit card and component, such as a relay or indicating lamp, has an identifier attached. This identifier, which is composed of ... where the item may actually be found on the console by section, surface and possible subassembly
Description : The small circular symbols to which wire '52N57E' is connected at coordinates '57L' and '57P' shown in the illustration represent ___________________. EL-0100 A. relay contact solder points B. wire wrap connections C. terminal board screws D. switch contact terminals
Description : As shown in the illustration, when the 'speed control' system is in 'SPLIT' _______________. EL-0096 A. Relays #1, #5 and #8 are not used B. the 'slew rated controller' is grounded through Relay ... E/P converters' are bypassed and air is fed directly to the governors via the 'load sharing valve'
Description : As shown in the illustration, once the "LV" relay is energized for operation, what contacts must remain closed to maintain the "LV" relay energized when the control lever is moved away from the "off" or "stop" ... . B. Reset contacts. C. Upper set of "LVa" contacts. D. Lower set of "LVa" contacts.
Description : What does the arrangement at coordinates '62E' shown in the illustration represent? EL-0099 A. Position recording drum and stylus B. Temperature compensating thyristor C. Miniature bridge rectifier D. Twisted wire pair within a shield
Description : What type of service is NOT provided by the circuit shown in the illustration? EL-0094 A. Logging of engine order signals from the bridge. B. Printed record of alarms as they ... . Visual metering of temperature and pressure conditions. D. Periodic recording of pressure and temperature conditions.
Description : Which of the following statements is true concerning the motor controller diagram shown in the illustration? EL-0023 A. Terminal 'T2' is hot only on high speed. B. Both indicating lights will be lit on ... high speed operation only. D. 'L2' is always connected to 'T2' whenever the motor is running.
Description : The electrical device shown in the illustration is a/an _____________. EL-0077 A. operating coil B. indicating lamp C. motor armature D. potentiometer
Description : The devices labeled 'L' in the illustration are _________. EL-0003 A. load lights indicating that the generator breaker is closed and the generator is supplying power to the main bus B. ... o'clock position the lights are at their dimmest or out indicating the the generators are in phase
Description : In an emergency, the fastest way to interrupt power and stop the winch shown in the illustration is for the ____________. EL-0102 A. mate to open the disconnect switch at 'L1' and 'L2' B. ... watch engineer to open the winch circuit breaker D. electrician to open the test link at the controller
Description : The device in figure 'B' shown in the illustration can be used to control an AC load yet maintain its high gain by ______________. EL-0091 A. connecting the load to the output side of the ... connecting the load to the input side of the bridge D. reversing the current flow through the bias winding
Description : Peripheral components for the operation of the astern valve position amplifier circuit shown in the illustration are _____________. EL-0099 A. resistors B. operated on +28 volts D.C. C. located on a separate circuit card D. all of the above
Description : As shown in the illustration, what is the meaning of the numbers in brackets [ ] at location '31/33U'? EL-0100 A. Four separate devices with these part numbers feed signals into this point. ... continues on those four pages and connects to devices at the indicated coordinates. D. None of the above.
Description : The schematic diagram shown in the illustration represents which of the listed solid-state circuits? EL-0069 A. Bridge rectifier B. Magnetic amplifier C. Flip-flop generator D. Cathodic amplifier
Description : Component 'B' of section 'I' shown in the illustration represents a _____________. EL-0093 A. bridge rectifier B. selsyn motor C. small generator D. shielded lamp
Description : The circuit shown in the illustration represents a/an ____________. EL-0085 A. operational amplifier B. Wheatstone bridge C. magnetic amplifier D. power supply
Description : RC time constant characteristics, as shown in the illustration, are important in _____________. EL-0086 A. bridge rectifiers for alternator excitation B. timing and pulse shaping circuits C. transistor power amplifier biasing D. motor controller overload protection
Description : In the illustration, 'D' is the symbol for a/an __________. EL-0005 A. thermal overload heater B. portable cable C. fuse D. indicating lamp
Description : The 'function generator' of the control circuit illustrated _______________. EL-0095 A. can be programmed to produce a non-linear output for a linear input depending on operating conditions B. is used for ... which or how many engines are needed for a required vessel speed D. all of the above
Description : As shown in the illustration, which of the listed actions of the synchroscope pointer is occurring? EL-0002 A. Revolving slowly in the slow direction. B. Revolving rapidly in the slow direction. C. ... stationary at the 12 o'clock position since the leading edges of the A phases are in phase.
Description : When reassembling the equipment shown in the illustration, _____________. El-0001 A. item 2A and 2B should not be installed on assembly #2 until assembly #3 or #4 have been secured to assembly ... be secured to assembly #1 to provide support to assembly #2 during the reassembling of the entire unit
Description : As shown in the illustration, what is responsible for maintaining the "LV" relay energized when the master switch handle is moved away from the "off" position? EL-0102 A. "DBa" contact. B. Reset contacts. C. Upper set of "LVa" contacts. D. Lower set of "LVa" contacts.
Description : What is the value of the capacitor in the astern valve position circuit shown in the illustration? EL-0099 A. 100 kFarad B. 0.5 microfarad C. 0.5 millifarad D. 50 kFarad
Description : When the master switch for the winch shown in the illustration is in the 'off' position, and the line & safe switches are closed, which of the listed relays should be energized? EL-0102 A. 'DB' & '2T' B. 'DB' & '4M' C. 'FR-B.O.' & 'LV' D. '1M' & '1A'
Description : When the operating handle is in the 'off' position, which master switch contacts for the winch shown in the illustration are closed? EL-0102 A. 'MS-DB & OL' B. 'MS-3, 5, 6, 7, & 8' C. 'MS-LVa & OL' D. 'MS-3, 7 & Reset'
Description : Pin #8 of the astern valve position sensor shown in the illustration is connected _______________. EL-0099 A. to analog common B. in series with PCOM C. to (-) 50 volts D.C. D. to (+) 50 volts D.C.
Description : Pin #6 of the ahead valve position sensor as shown in the illustration is connected _______________. EL-0099 A. to (-) 50 volts D.C. B. in parallel with PCOM C. to (+) 50 volts D.C. D. to analog common
Description : When 'selector switch' 'SEL8' shown in the illustration is in the 'TEST' position, contacts '3,4' and '7,8' are respectively ____________. EL-0100 A. open; closed B. closed; open C. open; open D. closed; closed
Description : When 'selector switch' 'SEL8' shown in the illustration is in the 'OFF' position, contacts '3,4' and '7,8' are respectively ____________. EL-0100 A. open; closed B. closed; open C. open; open D. closed; closed
Description : If power were lost to the winch shown in the illustration while in 'second point hoist' the winch would stop. When power is restored the winch would ______________. EL-0102 A. continue to run at ' ... switch' is returned to 'off' closing the 'reset' contacts and then moved to any 'run' position
Description : When 'selector switch' 'SEL8' shown in the illustration is in the 'ON' position, contacts '3,4' and '7,8' are respectively ______________. EL-0100 A. open; closed B. closed; open C. open; open D. closed; closed
Description : What controls rudder movement when the Operation Selector Switch shown in the illustration is in the 'NFU' position? EL-0097 A. Steering wheel B. Non-followup controller C. Gyro-compass D. Course selector pointer
Description : What controls the rudder when the 'operation selector switch' of the steering stand shown in the illustration is in the 'HAND' position? EL-OO98 A. Non-followup controller B. Gyro-compass C. Course selector pointer D. Steering wheel
Description : If coil 'R1-R2' on the transmitter in figure 'A' shown in the illustration is turned 30 degrees clockwise, corresponding coil 'R1-R2' on the receiver should ____________. EL-0092 A. make coils 'S1 ... a higher voltage depending on the turns ratio D. align itself to the same position if free to move
Description : As shown in the illustration, what happens when 'A' is closed, 'B' is in position '2' and component 'E2' burns out? EL-0058 A. 'H' energizes and 'D' makes contact. B. 'F' goes out allowing 'G' to disconnect. C. 'G' sounds an alarm and 'F' illuminates. D. 'C' opens causing 'A' to also open.
Description : You are performing an out-of-circuit test of the semi-conductor shown in the illustration. Using an ohmmeter on 'low power' position and with leads properly installed, which of the listed results would you expect the ... lead on 'B' and black lead on 'A'; and a low reading with the leads reversed.
Description : You are performing an out-of-circuit test of the semi-conductor shown in the illustration. Using an ohmmeter on 'low power' position and with leads properly installed, which of the listed results would indicate a good ... lead on 'A' and red lead on 'C'; and a high reading with the leads reversed.
Description : As shown in the illustration, which set of conditions, evident to the operator and the 'setpoint module' respectively, will result in a high exhaust temperature alarm on the 'starboard main engine'? EL-0094 A. 50°F and 3.3 volts B. 180°F and 6.0 volts C. 750°F and 0-10 volts D. 900°F and 7.5 volts
Description : The diagrams shown in the illustration represent a/an _______________. EL-0093 A. engine order telegraph circuit B. rudder angle indicator arrangement C. engine speed tachometer with repeaters D. sound powered telephone system