The device labeled 'REG SW' in the illustration is used to ___________. EL-0003 A. shift from the automatic voltage regulator to the manual voltage regulator B. shift the governor control from manual to automatic/zero droop C. enable the operator to read the field voltage on device 'REG ADJ' or device 'MAN ADJ' D. supply regulated control power to the switchboard  

1 Answer

Answer :

Answer: A

Related questions

Description : In the illustration, the component labeled 'EXC' is _______. EL-0003 A. a separate class II regulated DC generator for critical direct current loads B. a generator feeding the FLD ... to drive the governor for turbogenerator speed. D. the electronic driver for the switchboard metering circuits

Last Answer : Answer: B

Description : In the illustration, if one of the devices labeled 'TURB' should fail the ___________. EL-0003 A. device labeled 'EXC' will drive the alternator B. device labeled 'BKR' for that ... -alternator D. emergency generator should automatically start and be placed on line to supply emergency load centers

Last Answer : Answer: B

Description : The purpose of the automatic bus transfer shown in the illustration is to ___________. EL-0014 A. stepdown voltage to the lighting distribution panel B. provide emergency power to ... emergency switchboard from the main switchboard D. provide overcurrent protection to the lighting distribution panel

Last Answer : Answer: B

Description : Before servicing the device indicated as 'A' in panels #1 and #3 of the illustration, the device labeled 'CT' must __________. EL-0003 A. have the disconnected leads taped to prevent ... D. have one lead grounded to discharge static electricity for the prevention of damage to electronic components

Last Answer : Answer: C

Description : As shown in the illustration, the function of the switch labeled 'PFSW' is to determine the ______________. EL-0003 A. bus frequency B. reactive volt amperes of the bus C. frequency of either generator D. power factor of either generator

Last Answer : Answer: D

Description : Regarding an AC generator connected to the main electrical bus; as the electric load and power factor vary, a corresponding change is reflected in the generator armature reaction. These changes in ... . governor speed droop setting B. voltage regulator C. balance coil D. phase-balance relay

Last Answer : Answer: B

Description : The frequency of an alternator is controlled from the main switchboard by adjusting the _____________. A. frequency meter B. voltage regulator C. governor control D. sychroscope switch

Last Answer : Answer: C

Description : In the illustrated 450 VAC system, what should be provided between the bus and the device labeled 'F'? EL-0003 A. a potential transformer B. a current transformer C. an emergency disconnect device D. an audible alarm and indicating light

Last Answer : Answer: A

Description : The instantaneous reduction in voltage of an AC generator, resulting from an increase in load, and prior to the automatic voltage regulator correcting the situation, is called voltage ____________. A. droop B. drop C. dip D. regulation

Last Answer : Answer: C

Description : Equal power factors on paralleled AC generators are maintained by an automatic _____________. A. voltage regulator B. reverse power relay C. reverse current relay D. governor control switch

Last Answer : Answer: A

Description : A switchboard for an AC electrical system requires the use of which of the following devices? A. Frequency meter. B. Ohmmeter. C. Induction voltage regulator. D. Current transformer governor.

Last Answer : Answer: A

Description : When securing an AC generator, you should FIRST ___________. A. open the generator circuit breaker B. switch the voltage regulator to 'manual' C. decrease the field excitation to minimum D. reduce the load on the unit

Last Answer : Answer: D

Description : Automatic voltage regulators provided on switchboards function to _____________. A. regulate the AC load on the generator B. protect the switchboard from high voltage C. govern prime mover speed to control voltage D. vary the field excitation to the generators

Last Answer : Answer: D

Description : The +5 volt regulated power supply shown in the illustration is fed directly from the _______________. EL-0094 A. 115 volt AC bus B. Annunciator Module C. +24 volt supply D. Annunciator Controller

Last Answer : Answer: C

Description : When paralleling two AC generators, the frequency of the incoming machine immediately prior to closing its breaker should be ____________. A. controlled by placing the governor switch in the automatic ... regulator C. slightly greater than the bus frequency D. slightly less than the bus frequency

Last Answer : Answer: C

Description : The component labeled 'CR1' in the circuit shown in the illustration __________________. EL-0085 A. varies its anode/cathode polarity depending on 'RL' current B. rectifies the varying voltage from the ... reactance to smooth ripple D. establishes a constant reference voltage for the base of 'Q1'

Last Answer : Answer: D

Description : Which of the following statements is correct concerning the motor performance curves and data table shown in the illustration? EL-0006 A. The motor RPM at full load is 1737 RPM. B. The motor draws 12.62 kw ... If the motor was developing 10 HP its power factor would be 0.92. D. All of the above.

Last Answer : Answer: D

Description : Section II of the circuit shown in the illustration is the ____________. EL-0085 A. voltage regulator B. filter C. rectifier D. voltage transformer

Last Answer : Answer: C

Description : Section IV of the circuit shown in the illustration is the _____________. EL-0085 A. voltage regulator B. filter C. rectifier D. voltage transformer

Last Answer : Answer: A

Description : Section III of the circuit shown in the illustration is a _____________. EL-0085 A. voltage regulator B. filter C. rectifier D. voltage transformer

Last Answer : Answer: B

Description : In the illustration, the component VR2 on the A1 AMPLIFIER MODULE is _________. EL-0060 A. a zener diode to regulate the +9 volt power supply from common B. a variable resistor diode to control the output to terminal ... 2 at 9.1 volts DC D. a tunnel diode with a breakdown voltage of 6.6 Volts DC

Last Answer : Answer: C

Description : In the illustration, the component VR1 on the A1 AMPLIFIER MODULE is _________. EL-0060 A. a zener diode to regulate the +9 volt power supply from common B. a variable resistor diode to control the output to ... terminal 9 at 6.6 volts DC D. a tunnel diode with a breakdown voltage of 6.6 Volts DC

Last Answer : Answer: A

Description : In the illustration, the component VR1 on the A1A1 PCB is _________. EL-0060 A. a zener diode to regulate the +9 volt power supply B. a variable resistor diode to control the output to terminal 9 that controls ... terminal 9 at 6.6 volts DC D. a tunnel diode with a breakdown voltage of 6.6 Volts DC

Last Answer : Answer: C

Description : Two AC generators of the same capacity are operating in parallel. One with a zero speed droop setting and the other with a 5% speed droop. If its capacity is not exceeded, the unit whose ... B. maintain the frequency of the system C. have poor sensitivity characteristics D. have poor power response

Last Answer : Answer: B

Description : The motor starts when the start button in the illustration is pushed, but stops when the button is released the trouble is _________. EL-0007 A. the incorrect thermal overload coil B. a faulty 'M' coil C. a dirty contact on the Disc.Sw. at 'L3' D. a faulty holding relay contact

Last Answer : Answer: D

Description : The graph shown in the illustration represents the speed droop curves of two equal capacity alternators about to be paralleled. When paralleled, the greater portion of the total load above 60% for each unit will be picked up ... unit 'A' B. by unit 'B' C. equally by each unit D. none of the above

Last Answer : Answer: A

Description : A loss of field excitation to an AC generator while operating in parallel will cause it to ____________. A. absorb more and more load due to decreased armature reaction B. lose its load due to ... polarity D. lose its load, begin to motorize, trip out on reverse power relay, and possibly overspeed

Last Answer : Answer: D

Description : The kilowatt load can be adjusted on a paralleled generator by using the _____________. A. field rheostat B. governor control C. automatic voltage regulators D. hand tachometer

Last Answer : Answer: B

Description : The 'reset' contacts of the master switch shown in the illustration are ______________. EL-0102 A. closed only when the master switch is 'off' B. closed only when the master switch selects a 'run' condition C. opened separately by the winch operator D. opened when line voltage drops 10%

Last Answer : Answer: A

Description : The 'reset' contacts of the master switch shown in the illustration provides the winch controller with ___________. EL-0102 A. low voltage release B. overload protection C. low voltage protection D. high power factor correction

Last Answer : Answer: C

Description : In the illustration, the diode between terminals 16 and 17 is to _________. EL-0046 A. insure that the voltage across the governor coil (EG-3P) never exceeds .6 VDC B. compensate for the ... heating up C. protect the electronic governor from counter EMF D. act as a filter to prevent hunting

Last Answer : Answer: C

Description : The illustrated device is a _______. EL-0064 A. full wave bridge rectifier B. half wave bridge rectifier C. solid state voltage regulator D. direct current (DC) filter

Last Answer : Answer: A

Description : In the illustrated device, the part labeled '1A' _________. EL-0001 A. are start and run windings for a single phase shaded pole induction motor B. is the stator for a polyphase induction ... armature for a squirrel cage rotor motor D. are direct current shunt field windings for a universal motor

Last Answer : Answer: B

Description : The part of the shipboard electrical system used to control the distribution of power to the branch circuits, is the _____________. A. bridge control panel B. disconnect links C. governor relay box D. main switchboard

Last Answer : Answer: D

Description : As shown in the illustration, which of the following conditions will occur as a result of a momentary loss of power? EL-0017 A. The motor will automatically restart when power is restored. B. 'H-4' will open, ... the motor. D. 'A-1' or 'A-2' will open, necessitating a manual restarting of the motor.

Last Answer : Answer: B

Description : Moving the rheostat handle shown in the illustration, that is used to control a DC generator, towards the 'raise' direction will increase the _____________. EL-0030 A. field resistance B. armature resistance C. armature speed D. line voltage

Last Answer : Answer: D

Description : In an emergency, the fastest way to interrupt power and stop the winch shown in the illustration is for the ____________. EL-0102 A. mate to open the disconnect switch at 'L1' and 'L2' B. ... watch engineer to open the winch circuit breaker D. electrician to open the test link at the controller

Last Answer : Answer: B

Description : The governor control switch of an alternator is moved to the 'raise' position. This action will _____________. A. raise the no-load speed setting of the governor B. raise the percentage of speed droop C. lower the no-load speed setting of the governor D. lower the percentage of speed droop

Last Answer : Answer: A

Description : A constant output voltage from an AC generator is maintained by the _____________. A. prime mover governor B. exciter generator C. voltage regulator D. reverse power relay

Last Answer : Answer: C

Description : As shown in the illustration, the purpose of the item labeled 'Z', in assembly No. 2, is to _____________. EL-0001 A. keep the rotor in balance B. align the rotor to the stator C. dynamically balance the rotor D. cool the motor

Last Answer : Answer: D

Description : The purpose of the item labeled 'Z' in assembly No. 2, shown in the illustration is to _____________. EL-0001 A. keep the rotor in balance B. align the rotor to the stator C. dynamically balance the rotor D. cool the motor

Last Answer : Answer: D

Description : In the illustration, the component labeled D is a ______. EL-0033 A. fixed contact B. moving contact C. trip bar D. bimetallic strip

Last Answer : Answer: B

Description : In the illustration, the component labeled 'G' _________. EL-0031 A. is lined with cardboard to maintain a moisture (electrolyte) barrier between cells B. is a one piece container with compartments for each individual cell C. must be UL approved for shipboard use D. can only contain one cell

Last Answer : Answer: B

Description : In the illustration, the assembly labeled 2 is a ________. EL-0001 A. wound rotor and shaft for a single phase induction motor B. conduction rotor and shaft for a polyphase induction motor C. ... cage rotor and shaft for a polyphase motor D. squirrel cage rotor for a single phase induction motor

Last Answer : Answer: C

Description : In the illustration, the component labeled 'G' is ______. EL-0031 A. hard rubber, plastic or bituminous composition B. porous inside to absorb excess positive ions C. precharged for (-) and (+) in manufacturing D. All the above

Last Answer : Answer: A