As shown in the illustration, which of the following conditions will occur as a result of a momentary loss of power? EL-0017 A. The motor will automatically restart when power is restored. B. 'H-4' will open, necessitating a manual restarting of the motor. C. '10L' and '20L' will open, necessitating a manual restarting of the motor. D. 'A-1' or 'A-2' will open, necessitating a manual restarting of the motor.

1 Answer

Answer :

Answer: B

Related questions

Description : As shown in the illustration, which listed action will occur first when push button 'Q' is depressed? EL-0017 A. Contacts 'H-1', 'H-2' and 'H-3' close. B. Contact 'H-4' closes. C. Operating coil 'C' energizes. D. Switch 'R' opens.

Last Answer : Answer: C

Description : If the motor shown in the illustration will not start when 'Q' is depressed, which of the listed components should be checked FIRST? EL-0017 A. Fuses 'F-1' and 'F-2'. B. Operating coil 'C'. C. Contacts 'H-1', 'H-2', and 'H-3'. D. Contact 'H-4'.

Last Answer : Answer: A

Description : The type of control circuit that will not permit automatic restarting after power is restored, following a power failure is called _____________. A. low voltage protection B. low voltage release C. overload lockout D. reduced voltage restart

Last Answer : Answer: A

Description : A low-voltage protection circuit is used in electric motor starting equipment to _____________. A. trip circuit contactors when the motor overspeeds due to low voltage B. trip circuit ... voltage without manually resetting D. prevent the motor from restarting automatically on restoration of voltage

Last Answer : Answer: D

Description : When power is restored after a complete power failure, a steering gear pump motor will ____________. A. have to be restarted B. have to be reset C. restart automatically D. trip its overload relays

Last Answer : Answer: C

Description : 'A-1', as shown in the illustration, is/are ____________. EL-0017 A. normally-closed overload relay contacts B. a double pole knife switch C. normally-open overload relay contacts D. a single pole knife switch

Last Answer : Answer: A

Description : What operational characteristics do the components labeled as 'S' and 'R' represent in the motor controller diagram shown in the illustration? EL-0080 A. Standard and Reverse directions B. Stop and Restart features C. Subnormal and Regular loading D. Start and Run functions

Last Answer : Answer: D

Description : The electrical schematic shown in the illustration represents a/an ____________. EL-0017 A. across-the-line starter B. primary-resistor starter C. autotransformer starter D. part-winding starter

Last Answer : Answer: A

Description : As shown in the illustration, 'S' is the __________. EL-0017 A. safety switch B. overload trip C. start button D. stop button

Last Answer : Answer: D

Description : If fuse 'F-1' in the illustrated schematic diagram opens, ____________. EL-0017 A. the motor will run slowly B. 'A-1' and 'A-2' will open C. the motor will not start D. the start button will jam in the closed position

Last Answer : Answer: C

Description : Which of the listed items will stop a motor due to a reduction in voltage and restart it when the voltage is restored to normal? A. Low voltage protection circuit B. Non-renewable link fuse C. Renewable link fuse D. Low voltage release circuit

Last Answer : Answer: D

Description : Which of the listed conditions occur when '4th point lower' is selected on the winch shown in the illustration? EL-0102 A. Master switch contacts '3', '4', '6', '8', '9', & '10' close. B. Contactors '2, 3, & 4M' and ' ... , '7', '8', and '9' close. D. Contactors '1 & 3M' and '1, 2, & 3A' pick up.

Last Answer : Answer: B

Description : Which of the listed conditions occur when selection is made for 'third point hoist' on the winch shown in the illustration? EL-0102 A. Master switch contacts '5', '6', '7', '8', and '9' close. B. Contactors '2M', ' ... ' and '2A' drop out. D. Master switch contacts '3','4', '6', '8', and '9' close.

Last Answer : Answer: D

Description : What type of service is NOT provided by the circuit shown in the illustration? EL-0094 A. Logging of engine order signals from the bridge. B. Printed record of alarms as they ... . Visual metering of temperature and pressure conditions. D. Periodic recording of pressure and temperature conditions.

Last Answer : Answer: A

Description : As shown in the illustration, which set of conditions, evident to the operator and the 'setpoint module' respectively, will result in a high exhaust temperature alarm on the 'starboard main engine'? EL-0094 A. 50°F and 3.3 volts B. 180°F and 6.0 volts C. 750°F and 0-10 volts D. 900°F and 7.5 volts

Last Answer : Answer: D

Description : Which component will stop the motor shown in the illustration in case of an overload in the control circuit? EL-0080 A. 'E' B. 'G' C. 'H' D. 'I'

Last Answer : Answer: B

Description : Which device will stop the motor shown in the illustration in case of a short-circuit (high current) motor overload? EL-0080 A. 'F' B. 'G' C. 'H' D. 'I'

Last Answer : Answer: A

Description : Which two components, shown in the illustration, acting together will disconnect the motor from the line in case of a sustained motor overload? EL-0080 A. 'G' and 'H' B. 'E' and 'I' C. 'F' and 'H' D. 'E' and 'G'

Last Answer : Answer: B

Description : Which of the following statements describes what will occur if the motor shown in the illustration is required to carry 150% of full load? EL-0056 A. The primary counter emf will be increased. B. ... slip will decrease. D. The slip value, stator current curve, and torque curve will all coincide.

Last Answer : Answer: B

Description : As shown in the illustration, all 'MS' contacts are opened and closed by means of ________. EL-0073 A. operating coils B. magnets C. manual operation of the master switches D. solenoid switches

Last Answer : Answer: C

Description : As shown in the illustration, what happens when 'A' is closed, 'B' is in position '2' and component 'E2' burns out? EL-0058 A. 'H' energizes and 'D' makes contact. B. 'F' goes out allowing 'G' to disconnect. C. 'G' sounds an alarm and 'F' illuminates. D. 'C' opens causing 'A' to also open.

Last Answer : Answer: C

Description : In the illustration, if one of the devices labeled 'TURB' should fail the ___________. EL-0003 A. device labeled 'EXC' will drive the alternator B. device labeled 'BKR' for that ... -alternator D. emergency generator should automatically start and be placed on line to supply emergency load centers

Last Answer : Answer: B

Description : Which of the devices shown in the illustration automatically prevents the simultaneous operation of the windlass from both master switches? EL-0073 A. Selector switch B. Contact 'CR1a' C. Contact 'CR2a' D. Contact 'CR1D'

Last Answer : Answer: D

Description : Considering the function of the circuit shown in the illustration, what is the purpose of supplying the thrust lever potentiometers with both (+) and (-) 15 volts? EL-0095 A. To select which ... alternate voltage supply if the other fails. D. So as to automatically select the position of Relay #

Last Answer : Answer: B

Description : To stop the electric motor shown in the illustration, the stop button is depressed, causing ____________. EL-0012 A. coil 'MS' to become de-energized B. contacts 'CR1' and 'MR4' to open C. contacts 'MR1', 'MR2', and 'MR3' to open D. contacts 'MS1', 'MS2', and 'MS3' to open

Last Answer : Answer: C

Description : When the motor shown in the illustration is running and the stop button is pushed, which of the following statements will hold true? EL-0010 A. Coil 'M' will now be energized. B. Coil 'CR' will now be energized. C. Contact 'M' will close as contact 'CR' opens. D. Contacts 'M' and 'CR' will open.

Last Answer : Answer: D

Description : Low voltage releases as used in some shipboard motor starter and control equipment will have which of the following characteristics? A. They trip circuit contactors when the motor starts to overspeed. B. ... coil of the starter. D. They allow the motor to restart upon restoration of normal voltage.

Last Answer : Answer: D

Description : Which of the following statements is correct concerning the motor performance curves and data table shown in the illustration? EL-0006 A. The motor RPM at full load is 1737 RPM. B. The motor draws 12.62 kw ... If the motor was developing 10 HP its power factor would be 0.92. D. All of the above.

Last Answer : Answer: D

Description : RC time constant characteristics, as shown in the illustration, are important in _____________. EL-0086 A. bridge rectifiers for alternator excitation B. timing and pulse shaping circuits C. transistor power amplifier biasing D. motor controller overload protection

Last Answer : Answer: B

Description : If the three-phase motor, shown in the illustrated schematic diagram, is running in the forward direction, which of the following actions must occur before the motor will reverse rotation? EL-0011 A. Normally-closed ... 'L1' and 'L3' must be interchanged via the 'R' contacts. D. All of the above.

Last Answer : Answer: C

Description : The winch shown in the illustration will not operate in any speed in the lowering direction and at an abnormal speed in 'first point hoist'. The possible cause is that _______________. EL-0102 A. ... '1M' in the power circuit are badly corroded D. master switch contacts 'MS6' have weak springs

Last Answer : Answer: B

Description : The winch shown in the illustration operates in any of the positions with the master switch in the 'lower' direction, but will not 'hoist' in any of the master switch hoist positions. Which of the listed faults ... '2M' in the power circuit may be badly corroded. D. Series relay 'FR' may be open.

Last Answer : Answer: A

Description : In an emergency, the fastest way to interrupt power and stop the winch shown in the illustration is for the ____________. EL-0102 A. mate to open the disconnect switch at 'L1' and 'L2' B. ... watch engineer to open the winch circuit breaker D. electrician to open the test link at the controller

Last Answer : Answer: B

Description : The purpose of the capacitor within component 'B' of the circuit shown in the illustration is to ____________. EL-0081 A. prolong the life of the component's contacts B. discharge the neon within ... the inductive reactance in the circuit D. store power to operate the circuit should 'D' open

Last Answer : Answer: A

Description : The device labeled 'REG SW' in the illustration is used to ___________. EL-0003 A. shift from the automatic voltage regulator to the manual voltage regulator B. shift the governor control from manual to ... device 'REG ADJ' or device 'MAN ADJ' D. supply regulated control power to the switchboard

Last Answer : Answer: A

Description : If the inputs to the diagram shown in the illustration were J=1, K=0, H=0, L=1, M=1, what logic levels would be indicated at points 'X' and 'Y' respectively? EL-0089 A. 0,0 B. 0,1 C. 1,0 D. 1,1

Last Answer : Answer: D

Description : If the inputs to the diagram shown in the illustration were J=1, K=1, H=0, L=1, M=1, what logic levels would be indicated at points 'X' and 'Y' respectively? EL-0089 A. 0,0 B. 0,1 C. 1,0 D. 1,1

Last Answer : Answer: D

Description : If the inputs to the diagram shown in the illustration were J=0, K=0, H=1, L=0, M=1, what logic levels would be indicated at points 'X' and 'Y' respectively? EL-0089 A. 0,0 B. 0,1 C. 1,0 D. 1,1

Last Answer : Answer: C

Description : If the inputs to the diagram shown in the illustration were J=1, K=0, H=1, L=1, M=0, what logic levels would be indicated at points 'X' and 'Y' respectively? EL-0089 A. 0,0 B. 0,1 C. 1,0 D. 1,1

Last Answer : Answer: A

Description : Which set of truth table input signals will result in an output signal value of 1 from the 'AND' gate as shown in the illustration? EL-0035 A. 1-Jan B. Jan-00 C. 0-1 D. 0-0

Last Answer : Answer: A

Description : As shown in the illustration, which set of truth table input signals will result in an output signal at point 'Y'? EL-0035 A. 0-0 B. 0-1 C. Jan-00 D. 1-Jan

Last Answer : Answer: D

Description : Batteries 'A' and 'B' shown in the illustration are 6 volts each and batteries 'C' and 'D' are 24 volts each. If 'A' were connected in series-opposing to 'C' and 'B' was similarly ... the top terminal C. 30 volts, negative at the bottom terminal D. 30 volts, positive at the bottom terminal

Last Answer : Answer: A

Description : Batteries 'A' and 'B' shown in the illustration are 6 volts each and batteries 'C' and 'D' are 24 volts each. If 'A' and 'B' were reconnected to be in series-opposing to 'C' and 'D' ... at the top terminal C. 30 volts, negative at the bottom terminal D. 30 volts, positive at the bottom terminal

Last Answer : Answer: A

Description : The purpose of 'R6' in the winch circuit shown in the illustration is to _______________. EL-0102 A. maintain dry conditions within the winch brake box B. keep the series field current at ... to assist the winch in stopping D. limit the armature current during lowering operation with heavy loads

Last Answer : Answer: C

Description : In the pitch control diagram shown in the illustration, what are the present plant operating conditions? EL-0095 A. One engine is on the line, cruise mode is selected and the engine room is in control. ... . D. Both engines are on line, maneuvering mode is selected and the engine room is in control.

Last Answer : Answer: D

Description : What are the plant conditions existing in the 'engine speed control' diagram shown in the illustration? EL-0096 A. The Bridge is in control in the 'auto. maneuver' mode. B. The Engine Room is in control in ... in the 'auto. split' mode. D. The Engine Room is in control in the 'auto. maneuver' mode.

Last Answer : Answer: D