According to Coast Guard Regulations (46 CFR), a battery installation must be in a room that is only for batteries or a box on deck. This would be termed a ____________. A. small installation B. moderate installation C. large installation D. high amp/hour capacity installation

1 Answer

Answer :

Answer: C

Related questions

Description : In accordance with Coast Guard Regulations (46 CFR), each battery operated relay-controlled lantern must _____________. A. be readily portable B. contain a dry cell battery having a minimum capacity of ... automatic battery charger to maintain the battery in a fully charged state D. all of the above

Last Answer : Answer: C

Description : According to Coast Guard Regulations (46 CFR), which of the following systems must be arranged so as to be energized by the final emergency power source? A. at least one light in the ... operated watertight door system C. each charging panel for temporary emergency batteries D. all of the above

Last Answer : Answer: D

Description : Coast Guard Regulations (46 CFR) require manual contactors for operating the general emergency alarm on tank vessels to be located in the navigating bridge, engine room and the ____________. A ... C. crew accommodations and sleeping spaces D. engineering officers' quarters furthest from the bridge

Last Answer : Answer: A

Description : According to U. S. Coast Guard Regulations (46 CFR), the motor controller for a submersible electric motor driven bilge pump should be installed _____________. A. in the shaft alley B. at the submersible bilge pump C. above the uppermost continuous deck D. at the engine room emergency control panel

Last Answer : Answer: C

Description : According to Coast Guard Regulations (46 CFR), which of the following is an acceptable lining for battery trays containing alkaline batteries? A. Brass B. Lead C. Steel D. Zinc

Last Answer : Answer: C

Description : Coast Guard Regulations (46 CFR) require that lighting fixture globes must be protected by guards if the fixtures are located in the ____________. A. steering gear room B. galley C. living quarters D. wheelhouse

Last Answer : Answer: A

Description : In accordance with Coast Guard Regulations (46 CFR), a steering gear feeder circuit from the emergency switchboard or alternate power supply must have the capacity for continuous operation of the rudder 15° side to side in not more than 60 seconds for a A. 1/4 hour B. 1/2 hour C. 1 hour D. 2 hours

Last Answer : Answer: B

Description : If the illustrated lighting branch distribution box is not for cargo or deck lighting, the Coast Guard Regulations (46 CFR) requires the designed load attached to Branch NO.2 to be no more than _________. EL-0013 A. 5 amps B. 16 amps C. 30 amps D. 50 amps

Last Answer : Answer: B

Description : Coast Guard Regulations (46 CFR) require each switchboard to have ___________. A. non-conductive deck covering at the frount B. non-conductive deck coverings at the rear C. a name plate for each circuit breaker D. all the above

Last Answer : Answer: D

Description : According to Coast Guard Regulations (46 CFR), the talking and calling circuits of a sound powered telephone system must be _____________. A. intrinsically safe B. independent of each other C. independently grounded D. connected to a common ground

Last Answer : Answer: B

Description : Coast Guard Regulations (46 CFR) state that a continuous trickle charge, supplied from the ship's service power system, is required for batteries supplying power to the ___________. A. emergency diesel ... system for the radar C. portable radios for the lifeboats D. radios installed in the lifeboats

Last Answer : Answer: A

Description : Coast Guard Regulations (46 CFR) state that the minimum conductor size allowed for use in flexible electrical cords is ____________. A. 10 AWG B. 14 AWG C. 18 AWG D. 20 AWG

Last Answer : Answer: C

Description : Coast Guard Regulations (46 CFR 199) require that each lifesaving appliance, including lifeboat equipment, must be inspected at least once every _____________. A. week B. 2 weeks C. month D. 3 months

Last Answer : Answer: C

Description : When portable cords are connected to devices such as portable tools, you must eliminate direct tension on the joints or terminal screws. Coast Guard Regulations (46 CFR), allow this to be done by ... the plugs together C. installing a special fitting to eliminate plug separation D. all of the above

Last Answer : Answer: D

Description : Coast Guard Regulations (46 CFR) require that each alternating current generator arranged for parallel operation shall be provided with _____________. A. more than one means of excitation B. individual circuit fuses C. a high back-pressure trip D. a reverse-power trip

Last Answer : Answer: D

Description : Coast Guard Regulations (46 CFR) require instrument and control wiring in a switchboard to be of what minimum size? A. 12 AWG B. 14 AWG C. 16 AWG D. 18 AWG

Last Answer : Answer: B

Description : Where automatic restart does not present a hazard after a power failure, Coast Guard Regulations (46 CFR) require motor controllers for auxiliaries vital to the propelling equipment to be provided ... overload protection B. low voltage protection C. low voltage release D. reverse current protection

Last Answer : Answer: C

Description : Coast Guard Regulations (46 CFR) require that the emergency diesel generator engine shut down when _____________. A. lubricating oil pressure is lost B. the engine overspeeds dangerously C. fixed CO2 is released into the emergency diesel generator space D. all of the above

Last Answer : Answer: D

Description : Coast Guard Regulations (46 CFR) require that fire door holding and release systems are to comply with subpart _________. A. 111.15 B. 111.54 C. 111.99 D. 111.112

Last Answer : Answer: C

Description : Coast Guard Regulations (46 CFR), require that an indicating light at the propulsion control station will operate if overloading or overheating occurs in a _______________. A. forced draft blower motor B. steering gear motor C. fuel pump motor D. condensate pump motor

Last Answer : Answer: B

Description : According to Coast Guard Regulation (46 CFR) for emergency power and lighting systems, which of the listed items is the only permissible starting aid for the emergency diesel generator engine? A. Ether B. Lube oil heater C. Jacket water heater D. Fuel oil heater

Last Answer : Answer: C

Description : When choosing a battery for a particular application, major consideration should be given to the battery's ____________. A. amp-hour capacity B. terminal polarity C. stability under charge D. ambient temperature rise

Last Answer : Answer: A

Description : In the illustration if BRANCH NO. 1 is a lighting circuit for crew's berthing, Federal Regulations (46 CFR) require the maximum fuse rating for that branch to be _________. EL-0013 A. 80% of the connected load B. 15 amps C. 20 amps D. 30 amps

Last Answer : Answer: C

Description : Receptacle outlets aboard ship should be designed so those mounted according to 46 CFR 111 have _____________. A. there must be a sufficient number of receptacle outlets in the crew accommodations for an ... outlet must not have any exposed parts with the plug opening uncovered D. all of the above

Last Answer : Answer: D

Description : Which of the listed safety features should be provided in small rooms or lockers where batteries are stored? A. Installation of a fixed CO2 system. B. An exhaust duct is to be provided and led from within ... An exhaust duct is to be provided and led from the top of the locker to the open air.

Last Answer : Answer: D

Description : Why must a personal watercraft operator follow US coast guard rules and regulations?

Last Answer : Because they are considered a class A motor vessel

Description : The state of charge of a lead-acid battery is best indicated by the ____________. A. individual cell voltage B. ampere-hour capacity C. electrolyte specific gravity D. total cell voltage

Last Answer : Answer: C

Description : Batteries used for diesel engine starting should __________. A. be located in a locker on the weather deck B. be located as close as possible to the engine C. have sufficient capacity to provide at least 50 starts consecutively without recharging D. only be of the nickel alkaline type

Last Answer : Answer: B

Description : In the illustration if BRANCH NO. 1 is a lighting circuit for crew's berthing, 46 CFR requires the maximum fuse rating for that branch to be _________. EL-0013 A. 15 amps B. 80% of the connected load C. 20 amps D. 30 amps

Last Answer : Answer: C

Description : In a heat treatment shop, steel components are heat-treated in batches of 80 Tons. The  heat treatment cycle is as follows;  Increase temperature from 30 OC to 850 OC in 3 hours.  ... efficiency of 80%, for same requirement. The investment towards installation of  the new furnace is Rs. 50

Last Answer : Quantity of steel treated per batch - 80 Tons a. Efficiency of Furnace: Useful heat supplied to steel - 80000 x 0.12 x (850 - 30)   = 7872000 kcal/batch .1 mark Total heat ... = Rs. 64400/batch Efficiency of new LPG furnace - 80% Heat supplied in new LPG furnace - 7872000/0.8

Description : A hydrometer is used to measure the ____________. A. specific gravity of a battery electrolyte B. water pressure in a deck pipeline C. amount of potable water a vessel is taking on D. power developed by a salt water service pump

Last Answer : Answer: A

Description : When charging a 100 amp-hour lead-acid battery, ___________. A. the temperature of the electrolyte should not be allowed to exceed 90°F B. the charging rate should be no greater than 125% of the ... nearing full charge and it will be necessary to reduce the charging current to a low finishing rate

Last Answer : Answer: C

Description : When charging lead-acid batteries, the charging rate should be reduced as the battery nears its full charge to ____________. A. prevent damaging battery plates B. allow equalization of cell voltages C. reduce lead sulfate deposits D. increase lead peroxide formation

Last Answer : Answer: A

Description : Regarding battery charging rooms, ventilation should be provided __________. A. at the lowest point of the room B. horizontally near the batteries C. at the highest point of the room D. only when charging is in progress

Last Answer : Answer: C

Description : The Department of Transportation regulations 49 CFR require which parameter to be recorded on the shipping paper for hazard class 2.2 nonflammable compressed gases?

Last Answer : no

Description : A lead-acid battery can deliver 20 amperes continuously for 10 hours with an ampere-hour rating of ____________. A. 20 B. 40 C. 200 D. 400

Last Answer : Answer: C

Description : Which of the following statements concerning nickel-cadmium batteries is true? A. When mixing electrolyte always add acid to the water. B. Nickel-cadmium batteries can be charged and ... The electrolyte of an idle nickel-cadmium battery must be replaced monthly to maintain battery condition.

Last Answer : Answer: C

Description : When charging lead-acid batteries, you should reduce the charging rate as the battery nears its full charge capacity to ______________. A. prevent excessive gassing and overheating B. allow equalization of cell voltages C. reduce lead sulfate deposits D. increase lead peroxide formation

Last Answer : Answer: A

Description : When using a megohmmeter to determine which shunt field coil is grounded in a DC machine, you must ____________. A. insulate the field frame from the ship's hull B. disconnect each shunt ... C. use a motor driven high capacity megohmmeter D. remove all main line lead connections before testing

Last Answer : Answer: B

Description : A ____________ can run a completely isolated guest operating system installation within a normal host operating system. a) Virtual Monitor b) Virtual Machine Managerc) Virtual Box d) Virtual Machine

Last Answer : Virtual Machine

Description : According to the US coast guard statistics, what is the main cause of most fatal boating accidents?

Last Answer : poor operator judgment and lack of awareness.

Description : The state of charge of a lead acid storage battery is best indicated by the _____________. A. testing of the individual cell voltages B. ampere hour capacity of the battery C. specific gravity of the electrolyte D. total cell voltages

Last Answer : Answer: C

Description : Electrical insulation is classed by the _____________. A. International Association of Electrical Manufacturers B. approximate operating voltage and current expected C. U.S. Coast Guard D. temperature stability of the manufacturing material(s)

Last Answer : Answer: D

Description : How many hours will a 200 amp hour battery last at 168 watt?

Last Answer : If it is a car battery (as given in the category) it is reasonably safe to assume that under load it is about 12V. I = P/E = 168W / 12V = 14A T = 200AH / 14A = 14.29H However ... battery. This is also assuming that the car battery is not being charged at any time while the load is present.

Description : The signal to the circuit on card 'A0AA2' at coordinate '29Q' shown in the illustration is on the ____________. EL-0099 A. non-inverting input at pin '20' B. inverting input at pin '16' C. non-inverting input at pin '14' D. inverting input at pin '46'

Last Answer : Answer: B

Description : When two batteries are connected in parallel, it should be ensured that A. They have same emf B. They have same make C. They have same ampere hour capacity D. They have identical internal resistance

Last Answer : A. They have same emf