Coast Guard Regulations (46 CFR) require that the emergency diesel generator engine shut down when _____________. A. lubricating oil pressure is lost B. the engine overspeeds dangerously C. fixed CO2 is released into the emergency diesel generator space D. all of the above

1 Answer

Answer :

Answer: D

Related questions

Description : Coast Guard Regulations (46 CFR) require that each alternating current generator arranged for parallel operation shall be provided with _____________. A. more than one means of excitation B. individual circuit fuses C. a high back-pressure trip D. a reverse-power trip

Last Answer : Answer: D

Description : According to Coast Guard Regulation (46 CFR) for emergency power and lighting systems, which of the listed items is the only permissible starting aid for the emergency diesel generator engine? A. Ether B. Lube oil heater C. Jacket water heater D. Fuel oil heater

Last Answer : Answer: C

Description : Coast Guard Regulations (46 CFR) require manual contactors for operating the general emergency alarm on tank vessels to be located in the navigating bridge, engine room and the ____________. A ... C. crew accommodations and sleeping spaces D. engineering officers' quarters furthest from the bridge

Last Answer : Answer: A

Description : According to U. S. Coast Guard Regulations (46 CFR), the motor controller for a submersible electric motor driven bilge pump should be installed _____________. A. in the shaft alley B. at the submersible bilge pump C. above the uppermost continuous deck D. at the engine room emergency control panel

Last Answer : Answer: C

Description : Coast Guard Regulations (46 CFR) state that a continuous trickle charge, supplied from the ship's service power system, is required for batteries supplying power to the ___________. A. emergency diesel ... system for the radar C. portable radios for the lifeboats D. radios installed in the lifeboats

Last Answer : Answer: A

Description : Coast Guard Regulations (46 CFR 199) require that each lifesaving appliance, including lifeboat equipment, must be inspected at least once every _____________. A. week B. 2 weeks C. month D. 3 months

Last Answer : Answer: C

Description : In accordance with Coast Guard Regulations (46 CFR), a steering gear feeder circuit from the emergency switchboard or alternate power supply must have the capacity for continuous operation of the rudder 15° side to side in not more than 60 seconds for a A. 1/4 hour B. 1/2 hour C. 1 hour D. 2 hours

Last Answer : Answer: B

Description : According to Coast Guard Regulations (46 CFR), which of the following systems must be arranged so as to be energized by the final emergency power source? A. at least one light in the ... operated watertight door system C. each charging panel for temporary emergency batteries D. all of the above

Last Answer : Answer: D

Description : Coast Guard Regulations (46 CFR) require instrument and control wiring in a switchboard to be of what minimum size? A. 12 AWG B. 14 AWG C. 16 AWG D. 18 AWG

Last Answer : Answer: B

Description : Where automatic restart does not present a hazard after a power failure, Coast Guard Regulations (46 CFR) require motor controllers for auxiliaries vital to the propelling equipment to be provided ... overload protection B. low voltage protection C. low voltage release D. reverse current protection

Last Answer : Answer: C

Description : Coast Guard Regulations (46 CFR) require each switchboard to have ___________. A. non-conductive deck covering at the frount B. non-conductive deck coverings at the rear C. a name plate for each circuit breaker D. all the above

Last Answer : Answer: D

Description : Coast Guard Regulations (46 CFR) require that fire door holding and release systems are to comply with subpart _________. A. 111.15 B. 111.54 C. 111.99 D. 111.112

Last Answer : Answer: C

Description : Coast Guard Regulations (46 CFR), require that an indicating light at the propulsion control station will operate if overloading or overheating occurs in a _______________. A. forced draft blower motor B. steering gear motor C. fuel pump motor D. condensate pump motor

Last Answer : Answer: B

Description : Coast Guard Regulations (46 CFR) require that lighting fixture globes must be protected by guards if the fixtures are located in the ____________. A. steering gear room B. galley C. living quarters D. wheelhouse

Last Answer : Answer: A

Description : When portable cords are connected to devices such as portable tools, you must eliminate direct tension on the joints or terminal screws. Coast Guard Regulations (46 CFR), allow this to be done by ... the plugs together C. installing a special fitting to eliminate plug separation D. all of the above

Last Answer : Answer: D

Description : In accordance with Coast Guard Regulations (46 CFR), each battery operated relay-controlled lantern must _____________. A. be readily portable B. contain a dry cell battery having a minimum capacity of ... automatic battery charger to maintain the battery in a fully charged state D. all of the above

Last Answer : Answer: C

Description : According to Coast Guard Regulations (46 CFR), the talking and calling circuits of a sound powered telephone system must be _____________. A. intrinsically safe B. independent of each other C. independently grounded D. connected to a common ground

Last Answer : Answer: B

Description : According to Coast Guard Regulations (46 CFR), a battery installation must be in a room that is only for batteries or a box on deck. This would be termed a ____________. A. small installation B. moderate installation C. large installation D. high amp/hour capacity installation

Last Answer : Answer: C

Description : According to Coast Guard Regulations (46 CFR), which of the following is an acceptable lining for battery trays containing alkaline batteries? A. Brass B. Lead C. Steel D. Zinc

Last Answer : Answer: C

Description : Coast Guard Regulations (46 CFR) state that the minimum conductor size allowed for use in flexible electrical cords is ____________. A. 10 AWG B. 14 AWG C. 18 AWG D. 20 AWG

Last Answer : Answer: C

Description : If the illustrated lighting branch distribution box is not for cargo or deck lighting, the Coast Guard Regulations (46 CFR) requires the designed load attached to Branch NO.2 to be no more than _________. EL-0013 A. 5 amps B. 16 amps C. 30 amps D. 50 amps

Last Answer : Answer: B

Description : In the illustration if BRANCH NO. 1 is a lighting circuit for crew's berthing, Federal Regulations (46 CFR) require the maximum fuse rating for that branch to be _________. EL-0013 A. 80% of the connected load B. 15 amps C. 20 amps D. 30 amps

Last Answer : Answer: C

Description : Diesel generators #1 and #2 are operating in parallel at near full load capacity. Diesel generator #1 suddenly trips out mechanically due to low lube oil pressure. The reverse power relay functions ... all nonvital circuits. D. Secure alarms, reset reverse power relay, and restart #1 engine.

Last Answer : Answer: C

Description : Receptacle outlets aboard ship should be designed so those mounted according to 46 CFR 111 have _____________. A. there must be a sufficient number of receptacle outlets in the crew accommodations for an ... outlet must not have any exposed parts with the plug opening uncovered D. all of the above

Last Answer : Answer: D

Description : A low-voltage protection circuit is used in electric motor starting equipment to _____________. A. trip circuit contactors when the motor overspeeds due to low voltage B. trip circuit ... voltage without manually resetting D. prevent the motor from restarting automatically on restoration of voltage

Last Answer : Answer: D

Description : The Department of Transportation regulations 49 CFR require which parameter to be recorded on the shipping paper for hazard class 2.2 nonflammable compressed gases?

Last Answer : no

Description : Undervoltage trips are frequently installed on switchboard circuit breakers to trip ____________. A. out generators in the event of severe arcing or sparking B. out generators when there is reversal of power ... , but continues to run D. out generators when there is low voltage in the main circuit

Last Answer : Answer: D

Description : Which of the listed devices may be installed on a large diesel-electric alternating current propulsion generator? A. Temperature detector coils inserted in the stator slots for measuring stator temperature. B. ... . C. Electric space heaters to prevent condensation of moisture. D. All of the above.

Last Answer : Answer: D

Description : Chattering of the collector ring brushes on a generator may be remedied by _____________. A. lubricating brush holders B. reinsulating the brushes C. cleaning the collector rings D. increasing length of pigtail

Last Answer : Answer: C

Description : On some diesel-electric ships, the DC propulsion motor will only attain half speed when the generator fields are fully excited. Speeds above this are obtained by _____________. A. rotating brush ... B. raising the generator engine speed C. lowering the generator engine speed D. decreasing excitation

Last Answer : Answer: B

Description : Which of the following medium is compressed in a diesel engine cylinder? a. air b. air and fuel c. air and lubricating oil d. fuel

Last Answer : ANSWER a. air

Description : An emergency generator, driven by an internal combustion engine, shall be tested under load for a minimum of 2 hours at least once every _____________. A. week B. 2 weeks C. month D. 3 months

Last Answer : Answer: C

Description : If the bearings of an electrical generator are failing more frequently than expected and the lubricating oil is sludging then you should ______________. A. check the connections to the output leads B. ... replace the bearing with a sealed roller type D. replace the thrust bearing of the prime mover

Last Answer : Answer: B

Description : Electrical insulation is classed by the _____________. A. International Association of Electrical Manufacturers B. approximate operating voltage and current expected C. U.S. Coast Guard D. temperature stability of the manufacturing material(s)

Last Answer : Answer: D

Description : In the illustration if BRANCH NO. 1 is a lighting circuit for crew's berthing, 46 CFR requires the maximum fuse rating for that branch to be _________. EL-0013 A. 15 amps B. 80% of the connected load C. 20 amps D. 30 amps

Last Answer : Answer: C

Description : Why must a personal watercraft operator follow US coast guard rules and regulations?

Last Answer : Because they are considered a class A motor vessel

Description : Testing of the knocking characteristics of petrofuels is done in a __________ engine. (A) Carnot (B) CFR (Co-operative fuel research) (C) Stirling (D) Diesel

Last Answer : (B) CFR (Co-operative fuel research)

Description : The main purpose of an electric space heater installed in a large AC generator is to _____________. A. keep the lube oil warm for quick starting B. prevent moisture from condensing in the ... is shutdown C. prevent the windings from becoming brittle D. prevent acidic pitting of the slip rings

Last Answer : Answer: B

Description : The main purpose of an electric space heater installed in a large AC generator is to _____________. A. prevent the windings from becoming brittle B. prevent moisture from condensing in the windings during ... C. prevent acidic pitting of the slip rings D. keep the lube oil warm for quick starting

Last Answer : Answer: B

Description : The standard procedure for maintaining the charge in an emergency diesel starting battery is to trickle charge the battery _____________. A. continuously B. at least once each week C. whenever the charge falls to 75% of full charge D. whenever the electrolyte specific gravity falls to 1.250 or lower

Last Answer : Answer: A

Description : A diesel driven emergency generator is prevented from being paralleled with the ship's service generators by __________. A. an electrical interlock system B. an automatic paralleling trip switch C. the synchronizing oscilloscope D. the reverse current relay

Last Answer : Answer: A

Description : Under normal conditions, storage batteries used for starting the emergency diesel generator are maintained in a charged state by which of the following methods? A. Trickle charging B. Fast charging C. Equalizing charge D. Reverse charging

Last Answer : Answer: A

Description : Which one of the following petroleum refinery products has the lowest boiling point? (1) Kerosene (2) Gasoline (3) Diesel (4) Lubricating oil

Last Answer : (4) Lubricating oil Explanation: Lubricating oil is the most commonly used lubricant because of its wide range of possible applications. The two basic categories of lube oil are mineral and synthetic.

Description : Aniline point is the (A) Characteristic property of diesel & lubricating oils (B) Measure of aromatic content of oil (C) Both (A) and (B) (D) Neither (A) nor (B)

Last Answer : (C) Both (A) and (B

Description : The proper arrangement of the petroleum fractions in order of their boiling points is (A) Lubricating oil > diesel > petrol > LPG (B) Lubricating oil > petrol > diesel > LPG (C) Petrol > lubricating oil > diesel > LPG (D) Petrol > diesel > LPG > lubricating oil

Last Answer : (A) Lubricating oil > diesel > petrol > LPG