Coast Guard Regulations (46 CFR) require that lighting fixture globes must be protected by guards if the fixtures are located in the ____________. A. steering gear room B. galley C. living quarters D. wheelhouse

1 Answer

Answer :

Answer: A

Related questions

Description : Coast Guard Regulations (46 CFR) require manual contactors for operating the general emergency alarm on tank vessels to be located in the navigating bridge, engine room and the ____________. A ... C. crew accommodations and sleeping spaces D. engineering officers' quarters furthest from the bridge

Last Answer : Answer: A

Description : According to Coast Guard Regulations (46 CFR), which of the following systems must be arranged so as to be energized by the final emergency power source? A. at least one light in the ... operated watertight door system C. each charging panel for temporary emergency batteries D. all of the above

Last Answer : Answer: D

Description : Coast Guard Regulations (46 CFR), require that an indicating light at the propulsion control station will operate if overloading or overheating occurs in a _______________. A. forced draft blower motor B. steering gear motor C. fuel pump motor D. condensate pump motor

Last Answer : Answer: B

Description : In accordance with Coast Guard Regulations (46 CFR), a steering gear feeder circuit from the emergency switchboard or alternate power supply must have the capacity for continuous operation of the rudder 15° side to side in not more than 60 seconds for a A. 1/4 hour B. 1/2 hour C. 1 hour D. 2 hours

Last Answer : Answer: B

Description : According to Coast Guard Regulations (46 CFR), a battery installation must be in a room that is only for batteries or a box on deck. This would be termed a ____________. A. small installation B. moderate installation C. large installation D. high amp/hour capacity installation

Last Answer : Answer: C

Description : Coast Guard Regulations (46 CFR 199) require that each lifesaving appliance, including lifeboat equipment, must be inspected at least once every _____________. A. week B. 2 weeks C. month D. 3 months

Last Answer : Answer: C

Description : If the illustrated lighting branch distribution box is not for cargo or deck lighting, the Coast Guard Regulations (46 CFR) requires the designed load attached to Branch NO.2 to be no more than _________. EL-0013 A. 5 amps B. 16 amps C. 30 amps D. 50 amps

Last Answer : Answer: B

Description : Coast Guard Regulations (46 CFR) state that the minimum conductor size allowed for use in flexible electrical cords is ____________. A. 10 AWG B. 14 AWG C. 18 AWG D. 20 AWG

Last Answer : Answer: C

Description : Coast Guard Regulations (46 CFR) require that each alternating current generator arranged for parallel operation shall be provided with _____________. A. more than one means of excitation B. individual circuit fuses C. a high back-pressure trip D. a reverse-power trip

Last Answer : Answer: D

Description : Coast Guard Regulations (46 CFR) require instrument and control wiring in a switchboard to be of what minimum size? A. 12 AWG B. 14 AWG C. 16 AWG D. 18 AWG

Last Answer : Answer: B

Description : Where automatic restart does not present a hazard after a power failure, Coast Guard Regulations (46 CFR) require motor controllers for auxiliaries vital to the propelling equipment to be provided ... overload protection B. low voltage protection C. low voltage release D. reverse current protection

Last Answer : Answer: C

Description : Coast Guard Regulations (46 CFR) require each switchboard to have ___________. A. non-conductive deck covering at the frount B. non-conductive deck coverings at the rear C. a name plate for each circuit breaker D. all the above

Last Answer : Answer: D

Description : Coast Guard Regulations (46 CFR) require that the emergency diesel generator engine shut down when _____________. A. lubricating oil pressure is lost B. the engine overspeeds dangerously C. fixed CO2 is released into the emergency diesel generator space D. all of the above

Last Answer : Answer: D

Description : Coast Guard Regulations (46 CFR) require that fire door holding and release systems are to comply with subpart _________. A. 111.15 B. 111.54 C. 111.99 D. 111.112

Last Answer : Answer: C

Description : According to U. S. Coast Guard Regulations (46 CFR), the motor controller for a submersible electric motor driven bilge pump should be installed _____________. A. in the shaft alley B. at the submersible bilge pump C. above the uppermost continuous deck D. at the engine room emergency control panel

Last Answer : Answer: C

Description : When portable cords are connected to devices such as portable tools, you must eliminate direct tension on the joints or terminal screws. Coast Guard Regulations (46 CFR), allow this to be done by ... the plugs together C. installing a special fitting to eliminate plug separation D. all of the above

Last Answer : Answer: D

Description : In accordance with Coast Guard Regulations (46 CFR), each battery operated relay-controlled lantern must _____________. A. be readily portable B. contain a dry cell battery having a minimum capacity of ... automatic battery charger to maintain the battery in a fully charged state D. all of the above

Last Answer : Answer: C

Description : According to Coast Guard Regulations (46 CFR), the talking and calling circuits of a sound powered telephone system must be _____________. A. intrinsically safe B. independent of each other C. independently grounded D. connected to a common ground

Last Answer : Answer: B

Description : According to Coast Guard Regulations (46 CFR), which of the following is an acceptable lining for battery trays containing alkaline batteries? A. Brass B. Lead C. Steel D. Zinc

Last Answer : Answer: C

Description : Coast Guard Regulations (46 CFR) state that a continuous trickle charge, supplied from the ship's service power system, is required for batteries supplying power to the ___________. A. emergency diesel ... system for the radar C. portable radios for the lifeboats D. radios installed in the lifeboats

Last Answer : Answer: A

Description : According to Coast Guard Regulation (46 CFR) for emergency power and lighting systems, which of the listed items is the only permissible starting aid for the emergency diesel generator engine? A. Ether B. Lube oil heater C. Jacket water heater D. Fuel oil heater

Last Answer : Answer: C

Description : In the illustration if BRANCH NO. 1 is a lighting circuit for crew's berthing, Federal Regulations (46 CFR) require the maximum fuse rating for that branch to be _________. EL-0013 A. 80% of the connected load B. 15 amps C. 20 amps D. 30 amps

Last Answer : Answer: C

Description : In the illustration if BRANCH NO. 1 is a lighting circuit for crew's berthing, 46 CFR requires the maximum fuse rating for that branch to be _________. EL-0013 A. 15 amps B. 80% of the connected load C. 20 amps D. 30 amps

Last Answer : Answer: C

Description : When power is restored after a complete power failure, a steering gear pump motor will ____________. A. have to be restarted B. have to be reset C. restart automatically D. trip its overload relays

Last Answer : Answer: C

Description : Receptacle outlets aboard ship should be designed so those mounted according to 46 CFR 111 have _____________. A. there must be a sufficient number of receptacle outlets in the crew accommodations for an ... outlet must not have any exposed parts with the plug opening uncovered D. all of the above

Last Answer : Answer: D

Description : Why must a personal watercraft operator follow US coast guard rules and regulations?

Last Answer : Because they are considered a class A motor vessel

Description : The Department of Transportation regulations 49 CFR require which parameter to be recorded on the shipping paper for hazard class 2.2 nonflammable compressed gases?

Last Answer : no

Description : Which type of splice is used to splice a lighting fixture to a branch circuit?

Last Answer : Fixture joint.

Description : As shown in the illustration, what is the meaning of the numbers in brackets [ ] at location '31/33U'? EL-0100 A. Four separate devices with these part numbers feed signals into this point. ... continues on those four pages and connects to devices at the indicated coordinates. D. None of the above.

Last Answer : Answer: C

Description : As shown in the illustrations, ordered rudder angle is fed back from the ________________. EL-0097 A. power unit to the magnetic amplifier B. steering gear to the control potentiometer C. magnetic amplifier to the steering gear D. rudder yoke to the non-followup controller

Last Answer : Answer: A

Description : If the steering stand selector switch is allowed to remain in the 'Non-Followup' mode after testing of the steering gear, the rudder will _____________. EL-0097 A. not respond to commands from the ... actuator D. stop moving only when the helm is counter-rotated to put the pump at neutral stroke

Last Answer : Answer: A

Description : Which of the following is/are true concerning electric power operated watertight door systems? A. Each motor driven door must use the main bus as its source of power. B. Each distribution panel for ... to permit quick activation of the system. D. Each system must have a separate branch circuit.

Last Answer : Answer: D

Description : Time delayed or delayed action-type fuses are designed to _____________. A. prevent grounds in branch circuits B. prevent opens in motor circuits C. permit momentary overloads without melting D. guard lighting and electronic circuits

Last Answer : Answer: C

Description : In the early 1900's in England, there was two towns: town A and town B, and there was a huge river in between them. The only way across to each town was by a long bridge with a guard ... back. Many people have tried to cross but have always been caught, even very fast runners have only ab -Riddles

Last Answer : Did you get it? The answer is that they went up close to the guards tower, turned around and started walking back to the town they came from, the guard caught them and assumed that they came ... way and sent them back! Hope you enjoyed this, please subscribe and check back soon for more riddles!

Description : As shown in the illustrations, fine adjustments such as 'weather' and 'turning rate' have no effect on steering stand operation when the 'operation control switch' is in ____________. EL-0097 A. GYRO B. HAND C. NFU D. DIFF

Last Answer : Answer: C

Description : Electrical insulation is classed by the _____________. A. International Association of Electrical Manufacturers B. approximate operating voltage and current expected C. U.S. Coast Guard D. temperature stability of the manufacturing material(s)

Last Answer : Answer: D

Description : In the lighting distribution circuit shown in the illustration, if all switches are closed and fuse 'F2' were to open, all lights on branches ____________. EL-0013 A. '1', '2', and '3' would go out B. '1' ... and '3' would burn dimly D. '1' and '3' would go out, while branch '2' would remain lit

Last Answer : Answer: D

Description : The signal to the circuit on card 'A0AA2' at coordinate '29Q' shown in the illustration is on the ____________. EL-0099 A. non-inverting input at pin '20' B. inverting input at pin '16' C. non-inverting input at pin '14' D. inverting input at pin '46'

Last Answer : Answer: B

Description : Sound Technical advice for wiring a room that already has a sconce light for a ceiling fixture?

Last Answer : If the wall is an interior wall then it should be an empty cavity. If it is an old home you may have fire stops inside the walls that will be a dead end when you attempt to fish the wire down. Make ... a good idea to know how much load is already on the circuit if you want to still use the sconce.

Description : Is the steering gear box the same on a 1954 and a 1956 International 300 tractor?

Last Answer : Yes it is check it out here http://www.hemmings.com/hmn/stories/2008/08/01/hmn_feature37.html

Description : The tie rod connects the front wheel spindle arms and is actuated by the steering shaft through a) chain link b) gear link c) tension link d) drag link

Last Answer : d) drag link

Description : What is special about Steering gear Overload safety?

Last Answer : Short Circuit protection and were appropriate-single phase protection is fitted. In addition instead of over current protection an Overload alarm is fitted set to operate at not less than twice normal running current.

Description : Describe the working of recirculating ball type steering gear box with sketch.

Last Answer : Working of Recirculating ball type steering gear box: It consists of worm at the end of steering rod. A nut is mounted on the worm with two sets of balls in the grooves of the worm, in between ... and actual the link rod through the drop arm, resulting in the desired steering of the wheels.

Description : Name the steering gear box used in following:  (i) Maruti ‘Alto’  (ii) Tata ‘Sumo’  (iii) Ashok Leyland Truck (iv) Road Roller

Last Answer : (i) Maruti ‘Alto’=========Rack and Pinion Type Gear Box. (ii) Tata ‘Sumo’==========Recireulating Ball Type Gear Box. (iii) Ashok Leyland Truck === Worm and Nut Type Gear Box (iv) Road Roller=========== Worm and Roller Type Steering Gear Box

Description : Draw a sketch of rack and pinion steering gear mechanism. Explain its working.

Last Answer : Working: The rotary motion of the steering wheel is transmitted to the pinion of the steering gear through universal joints. The pinion is mesh with a rack. The circular motion of the pinion is ... relayed through the ball joints and the rods to the stub axles for the wheels to be steered.