What is mean by the AC coil split?

1 Answer

Answer :

Feel Free to Answer

Related questions

Description :  In dynamometer type of wattmeter, which of the coil is split up into two parts?

Last Answer :  In dynamometer type of wattmeter, which of the coil is split up into two parts?  current coil

Description : Why should one choose a split AC over a window AC?

Last Answer : Advantages of Split ACs They are a lot quieter, even the normal split ACs are quieter than inverter window ACs. They could be more efficient depending on how it was installed. It gives you more flexibility in designing your room. You can put your indoor unit anywhere as long as there are provisions.

Description : Which types of problems occur in a split AC?

Last Answer : without a doubt the major problem is poor installation. this include but not limited to poor or inadequate evacuation procedures, failure to level the FCU and apply a reasonable fall on drains, failure to run pipework correctly for good oil return, and so on.

Description : Which split AC is best?

Last Answer : The best split ac as of now is Voltas 1.5 ton 3 star split ac After looking at a number of alternative split acreages, this is the one that I believe will be the best in 2021. You will ... the settings after a power outage. I come with a one-year product warranty and a five-year compressor warranty.

Description : How is split AC serviced?

Last Answer : TWO TYPES OF SERVICES ARE DONE HERE. Regular service (indoor unit alone is serviced, with a standard cost). Complaint service (indoor and outdoor units are serviced, cost depends on the service done) ... . So it is always better to book a complaint over service in spite of having no complaints.

Description : When three-phase AC power is supplied to the device shown in the illustration, the output will be _____________. EL-0063 A. single-phase AC B. split-phase AC C. three-phase DC D. unidirectional DC

Last Answer : Answer: D

Description : The hook-on AC volt-ammeter consists essentially of a split-core and a rectifiertype instrument connected to the secondary winding of a _____________. A. potential transformer B. control transformer C. current transformer D. reactance transformer

Last Answer : Answer: C

Description : Which type of AC single-phase motor will also operate on direct current? A. Split-phase B. Series-wound C. Shaded-pole D. Repulsion-start

Last Answer : Answer: B

Description : An AC circuit consists of a resistance and a choke coil in series . The resistance is of 220 `Omega` and choke coils is of 0.7 H . The power abosorbed

Last Answer : An AC circuit consists of a resistance and a choke coil in series . The resistance is of 220 ` ... 50 Hz , source connected with the circuit , is

Description : Three factors responsible for the change in voltage as load is applied to an AC generator are: 1) the drop in resistance in the armature circuit, 2) the change in flux, and 3) the ____________. A. armature winding speed B. inductance load drop C. coil pitch factor D. armature reactance voltage drop

Last Answer : Answer: D

Description : A short in the shunt field of a DC motor is best located by _____________. A. visual inspection of the commutator B. applying AC voltage to each field coil and measuring the voltage drop across ... using a growler and hacksaw blade D. isolating each coil from the others and using a megohmmeter

Last Answer : Answer: B

Description : If two AC generators have just been placed in parallel, the true power load is initially distributed evenly by _____________. A. a balance coil B. changing field excitation C. adjusting the governor control settings D. a rheostat

Last Answer : Answer: C

Description : The leads from a megohmmeter are attached to the leads of an AC motor field coil. A reading of infinity is obtained indicating a/an ____________. A. open field coil B. shorted field coil C. grounded field coil D. shunted field coil

Last Answer : Answer: A

Description : In an AC circuit, the inductive reactance of a coil varies with the _______________. A. resistance of the circuit B. frequency of the circuit C. voltage of the circuit D. current of the circuit

Last Answer : Answer: B

Description : Excessive humming of AC contactors may be caused by ______________. A. burnt arc shields B. shorted armature coils C. a broken shading coil D. high voltage

Last Answer : Answer: C

Description : A loud buzzing noise in an AC controller is probably caused by _____________. A. poor contact with the overload relay B. an incorrectly sized heater C. a broken shading coil D. abnormal starting current

Last Answer : Answer: C

Description : Which of the following methods should be used to test for an 'open' coil in an AC motor stator? A. Test with an ohmmeter, one test lead on the shaft, and the other test lead to the stator leads ... an open coil. D. Use a growler, listening for noise and vibration to increase when over an open coil.

Last Answer : Answer: B

Description : A testing device called a 'growler' is being used to locate a shorted coil in the stator of an AC electrical machine. When the 'feeler' is moved over a slot containing the shorted coil _____________. ... . the meter needle will be deflected to zero D. the meter needle will be deflected to full-scale

Last Answer : Answer: A

Description : Aboard ship, a grounded field coil in an AC motor can be determined by using a _________________. A. portable growler B. galvanometer C. visual inspection D. megohmmeter

Last Answer : Answer: D

Description : Shading coils are installed on AC full-voltage starters to _____________. A. eliminate contact chatter B. dissipate opening contact arcs C. delay current build up in the holding coil D. protect the motor windings from momentary starting current overload

Last Answer : Answer: A

Description : A shading coil used in an AC magnetic controller, functions to _____________. A. reduce vibration and noise in the contactor B. prevent flux buildup in the operating coil C. eliminate arcing when the contacts close D. energize the operating coil and 'pull in' the contacts

Last Answer : Answer: A

Description : Regarding an AC generator connected to the main electrical bus; as the electric load and power factor vary, a corresponding change is reflected in the generator armature reaction. These changes in ... . governor speed droop setting B. voltage regulator C. balance coil D. phase-balance relay

Last Answer : Answer: B

Description : How can you start-up the 40w tube light with 230v AC/DC without using any choke/Coil?

Last Answer : It’s possible by means of Electronic choke. Otherwise it's not possible to ionize the particles in tube light, with normal voltage.

Description : One of the following is a possible cause of an abrupt frequency variation in a self exited transmitter oscillator circuits resulting to a poor frequency stability to hold a constant frequency ... capacitor in the oscillator D. Loose connections in the oscillator, amplifier, or antenna circuits.

Last Answer : D. Loose connections in the oscillator, amplifier, or antenna circuits.

Description : In an AC dynamo, the speed at which the coil rotates is doubled. How would this affect a) the frequency of output voltage b) the maximum output voltage?

Last Answer : a) Frequency is doubled b) Maximum output voltage is doubled.

Description : How can we start-up the 40w tube light with 230v AC/DC without using any choke/Coil?

Last Answer :  It is possible by means of Electronic choke. Otherwise it’s not possible to ionize the particles in tube. Light, with normal voltage.

Description : In the plane of AC generator coil is parallel to the field, then emf induced in coil is: a. maximum b. minimum c. zero d. intermediate

Last Answer : b. minimum

Description : Turn ratio of a transformer is 5. If 220 V AC is applied to its primary coil, voltage in the secondary coil will be: a. 44V b. 4.4 V c. 220V d. 1100V

Last Answer : c. 220V

Description : The primary coil of a transformer is connected to a 60 V ac source. The secondary coil is connected to a 330 ohms load. The turns ratio is 3:1. What is the secondary voltage? A.2 V B.20 V C.180 V D.18 V

Last Answer : The primary coil of a transformer is connected to a 60 V ac source. The secondary coil is connected to a 330 ohms load. The turns ratio is 3:1. What is the secondary voltage? A.2 V B.20 V C.180 V D.18 V

Description : A two-phase generator is connected to two 90Ω load resistors. Each coil generates 120 V ac. The value of current flowing through the common neutral line will be: A. 1.33 A B. 1.88 A C. 2.66 A D. 1.77 A

Last Answer : A two-phase generator is connected to two 90Ω load resistors. Each coil generates 120 V ac. The value of current flowing through the common neutral line will be: 1.77 A

Description : With English muffins, what does "fork split" even mean?

Last Answer : It means it’s not cut open with a knife, where the opening is sharp and distinct. It’s so the butter can melt into the little nooks and crannies which are natural in yeast breads.