1 Answer

Answer :

The multiplier and the meter coil in a voltmeter are in series.

Related questions

Description : A moving coil of meter has 100 turns, and a length and depth of 10mm and 20mm respectively. It is positioned in a uniform radial flux density of 200 mT. The coil carrier current capacity is 50 mA. The torque on the coil is

Last Answer : A moving coil of meter has 100 turns, and a length and depth of 10mm and 20mm respectively. It is positioned in a uniform radial flux density of 200 mT. The coil carrier current capacity is 50 mA. The torque on the coil is 200µNm

Description : A moving coil meter has a resistance of 3 Ω and gives full scale deflection with 30 mA. To measure voltage up to 300 V, the external resistance to be connected in series with the instrument is (A) 9997 Ω (B) 10000 Ω (C) 997 Ω (D) 10003 Ω

Last Answer : A moving coil meter has a resistance of 3 Ω and gives full scale deflection with 30 mA. To measure voltage up to 300 V, the external resistance to be connected in series with the instrument is 9997 Ω

Last Answer : A moving-coil permanent-magnet instrument can be used as flux-meter by eliminating the control springs.

Description : An ac voltmeter using full -wave rectification and having a sinusoidal input has an ac sensitivity equal to  (1) 1.414 times dc sensitivity (2) dc sensitivity (3) 0.9 times dc sensitivity (4) 0.707 times dc sensitivity

Last Answer : An ac voltmeter using full -wave rectification and having a sinusoidal input has an ac sensitivity equal to 0.9 times dc sensitivity

Description : An unshielded moving iron voltmeter is used to measure the voltage in an AC circuit. The stray DC magnetic field having a component along the axis will be  (1) unaffected (2) decreased (3) increased (4) either decreased or increased depending on the direction of the DC field

Last Answer : An unshielded moving iron voltmeter is used to measure the voltage in an AC circuit. The stray DC magnetic field having a component along the axis will be either decreased or increased depending on the direction of the DC field

Last Answer : Voltmeter is used to measure voltage in a circuit.Ohmmeter is used to measure the resistance of a component in a circuit.

Description : Permanent magnet moving coil instruments are used for

Last Answer : PMME are mostly used for measuring voltage and current.

Description : The self inductance of a coil can be measured using (A) Wien’s Bridge (B) Schering Bridge (C) Anderson’s Bridge (D) Wheatstone Bridge

Last Answer : The self inductance of a coil can be measured using Anderson’s Bridge

Description : A PMMC instrument has FSD of 100 μA and a coil resistance of 1 kΩ. To convert the instrument into an ammeter with full scale deflection of 100 mA, the required shunt resistance is (A) 1 Ω (B) 1.001 Ω (C) 0.5 Ω (D) 10 Ω

Last Answer : A PMMC instrument has FSD of 100 μA and a coil resistance of 1 kΩ. To convert the instrument into an ammeter with full scale deflection of 100 mA, the required shunt resistance is 1.001 Ω

Last Answer : In a low power factor wattmeter the compensating coil is connected in series with pressure coil.

Last Answer : In a low power factor wattmeter the pressure coil is connected to the load side of the current coil.

Last Answer : A moving-coil permanent-magnet instrument can be used as ammeter by using a low resistance shunt.

Description : Use Voltmeter, ammeter, wattmeter to determine active, reactive and apparent power consumed in given R—C series circuit, draw phasor diagram.

Last Answer : Use Voltmeter, ammeter, wattmeter to determine active, reactive and apparent power consumed in given R-C series circuit, draw phasor diagram. Practical Significance In the industry environment ... autotransformer position to zero and switch OFF the supply. 8. Draw the phasor diagram.

Description : Use Voltmeter, ammeter, wattmeter to determine active, reactive and apparent power consumed in given R-L series circuit, draw phasor diagram.

Last Answer : Practical Significance In the industry environment Electrical Engineering diploma graduate are expected to measure basic parameters like voltage, frequency, time period etc. for R-L series circuits. Therefore ... /varying L. 7. Draw the phasor diagram for each of reading for verification.

Description : operation of half wave rectifier type AC Voltmeter.

Last Answer :  Half-wave Rectifier Voltmeter The d'Arsonval meter movement only responds to the average or dc value of the current through the moving coil. In order to measure alternating ... ) input voltage signal alternating signal needs to be rectified first by using diode rectifier to produce 

Description : advantages of DVM over electric voltmeter?

Last Answer : Advantages:  1) In case of digital volt meter the output signals is available in the form of discrete numerical. Where as in analog voltmeter, output is made available by using pointer ... using a suitable transducer the quantities such as temperature, pressure, etc. can also be measured.

Description : How range of A.C. ammeter & A.C. voltmeter is extended? Draw suitable diagram.

Last Answer : Extension of A.C. Ammeter Range: The range of a.c. ammeter can be extended by using CT, the arrangement is shown in figure. The CT is current transformer having less number of primary turns carrying high ... high magnitude of source voltage. In this way range of a.c. voltmeter can be extended.

Description : Draw a typical electric circuit including ammeter and voltmeter.

Last Answer : The figure shows typical electric circuit including ammeter and voltmeter. Ammeter is connected in series for measurement of current. Voltmeter is connected in parallel for measurement of voltage. Fuse is use ... are used. If the electric supply is DC the DC ammeter and DC voltmeter are used.

Description : The operation of a ramp type Digital Voltmeter is based on the principle of (A) Voltage-to-current conversion. (B) Voltage-to-time conversion. (C) Current-to-time conversion. (D) Current-to-frequency conversion.

Last Answer : The operation of a ramp type Digital Voltmeter is based on the principle of Voltage-to-time conversion.

Description : what is voltmeter ?

Last Answer : Voltmeter is an instrument which is use for measuring voltage in volts.

Description : If the fault current is 6000 A, the relay plug setting is 150% and the CT ratio is 400/5, the plug setting multiplier will be

Last Answer : If the fault current is 6000 A, the relay plug setting is 150% and the CT ratio is 400/5, the plug setting multiplier will be 10

Description : For measurement of radio frequency ac signals __________ type meter is used

Last Answer : For measurement of radio frequency ac signals thermo-couple type meter is used

Description : The meter which does not have any component in it to provide control torque is (A) Electrodynamometer for current measurement (B) Electrodynamometer for voltage measurement (C) Electrodynamometer for power measurement. (D) Electrodynamometer for power factor measurement.

Last Answer : The meter which does not have any component in it to provide control torque is Electrodynamometer for power factor measurement.

Description : An induction type energy meter is found to run fast. Correction for this error can be made by  (A) Over-load compensation. (B) Voltage compensation. (C) Moving the brake magnet away from the centre of the disc. (D) Moving the brake magnet towards the centre of the disc.

Last Answer : An induction type energy meter is found to run fast. Correction for this error can be made by Moving the brake magnet away from the centre of the disc.

Description : A 200 V, 5 A d.c. energy meter is tested at its marked ratings. The resistance of the pressure circuit is 8000 Ω and that of current coil is 0.1 Ω. The power consumed when testing the meter with phantom loading with current circuit excited by a 6 V battery is (A) 2.5 W (B) 5 W (C) 32.5 W (D) 35 W

Last Answer : A 200 V, 5 A d.c. energy meter is tested at its marked ratings. The resistance of the pressure circuit is 8000 Ω and that of current coil is 0.1 Ω. The power consumed when testing the meter with phantom loading with current circuit excited by a 6 V battery is 35 W

Last Answer : A Weston frequency meter is moving iron instrument.

Last Answer : In a Weston frequency meter, the magnetic axes of the two fixed coils are perpendicular.

Last Answer : In a vibrating reed frequency meter the natural frequencies of two adjacent reeds have a difference of 0.5 Hz.

Last Answer : In a dynamometer 3-phase power factor meter, the planes of the two moving coils are at 120°.

Last Answer : In a single phase power factor meter the phase difference between the currents in the two pressure coils is exactly 90°.

Last Answer : The two pressure coils of a single phase power factor meter have the same dimensions and the same number of turns.

Last Answer : A power factor meter has one current circuit and two pressure circuits.

Last Answer : The adjustment of position of shading bands, in an energy meter is done to provide friction compensation.

Last Answer : The household energy meter is an integrating instrument.

Last Answer : An induction meter can handle current up to 100 A.

Description : What type of meter is used to measure current?

Last Answer : Ammeter

Description : When the voltage across a battery is measured using a D.C potentiometer, the reading shows 1.08 V. But when the same voltage is measured using a Permanent Magnet Moving Coil (PMMC) voltmeter, the voltmeter reading shows 0.99 ... resistance of the battery, in Ohm , is (A) 150 (B) 100 (C) 50 (D) 200

Last Answer : When the voltage across a battery is measured using a D.C potentiometer, the reading shows 1.08 V. But when the same voltage is measured using a Permanent Magnet Moving Coil (PMMC) voltmeter, ... resistance of the voltmeter is 1100 Ohm , the internal resistance of the battery, in Ohm , is 100

Description : What do you mean by coil?

Last Answer : Ans. Having one or more turns connected in series is called coil.

Description : State the function of overload coil and No volt coil in dc motor starter.

Last Answer : Function of Overload Coil: When DC motor is overloaded, the overload coil carries the overload current and produces strong magnetic field to attract a plunger, which short the terminals of ... dc motor is prevented from restarting automatically on recovery of supply without starter and protected.

Description : Name the material used for :- (i) Moving coil (ii) Permanent magnet in PMMC instrument.

Last Answer : (i) Material used for Moving coil: Copper, Aluminum( some times)  (ii) Permanent magnets are made of special alloys such as :  Aluminum-Nickel-Cobalt (Alnicos)  Strontium-Iron  Neodymium-Iron-Boron  Samarium-Cobalt.

Description : State the material used for moving coil and former for PMMC instruments. 

Last Answer : Material Used for Moving Coil and Former for PMMC Instruments:  Material used for moving coil: Copper  Material used for Former: Aluminium

Description : The purpose of the restraining coil in a biased differential relay is  (A) To reduce CT saturation during fault.  (B) To increase the sensitivity of the relay.  (C) To match the transformation ratio.  (D) To limit the spill current through the relay during heavy external fault.

Last Answer : d

Description : Peterson coil is used for :  (A) shunt compensation of lines (B) grounding of system neutral (B) reduce fault currents (D) connecting interconnected systems

Last Answer : Peterson coil is used for : grounding of system neutral

Description : A Peterson coil is ________ A) An arc generating coil B) An arc suppressing coil C) An arc inducing coil D) None of these

Last Answer : A Peterson coil is An arc suppressing coil

Description : lt the length, number of turns and area of a coil are  doubled, the inductance of the coil

Last Answer : lt the length, number of turns and area of a coil are  doubled, the inductance of the coil is quadrupled

Description : The potential coil of a single phase dynamometer wattmeter has 4840 Ohm resistance. Voltage across the load is 220 V. With the potential coil connected on the load side, the meter indicates 100 W. Approximate percentage error due to wattmeter connection is (A) 11% (B) 9% (C) 1.1% (D) 3%

Last Answer : The potential coil of a single phase dynamometer wattmeter has 4840 Ohm resistance. Voltage across the load is 220 V. With the potential coil connected on the load side, the meter indicates 100 W. Approximate percentage error due to wattmeter connection is 11%

Description : The initial rate of rise of current through a coil of inductance 10 H when suddenly connected to a D.C. supply of 200 V is_______Vs.

Last Answer : The initial rate of rise of current through a coil of inductance 10 H when suddenly connected to a D.C. supply of 200 V is 20 Vs

Description : The rate of rise of current through an inductive coil is maximum?

Last Answer : The rate of rise of current through an inductive coil is maximum at the start of the current flow.

Description : The inductance of a coil can be increased by?

Last Answer : The inductance of a coil can be increased by choosing core material having high relative permeability.

Description : Inductance of coil?

Last Answer : Inductance of coil increases with the increase in supply frequency.