Explain the measurement of voltage and frequency using CRO.

1 Answer

Answer :

Voltage Measurement: CRO displays the voltage signal as a function of time on its screen. The amplitude of that voltage signal is constant, but we can vary the number of divisions that cover the voltage signal in vertical direction by varying volt/division knob on the CRO panel. Therefore, we will get the amplitude of the signal, which is present on the screen of CRO by using following formula.

A=j×nv

Where,

A is the amplitude

j is the value of volt/division

nv is the number of divisions that cover the signal in vertical direction.

image

Related questions

Description : Explain how CRO is used for measurement of frequency & amplitude with suitable diagram

Last Answer : Voltage measurement/Amplitude: The most direct voltage measurement that can be made with the help of oscilloscope is the peak to peak value. The RMS value can be calculated from peak to peak value. ... is the time between two identical points of successive cycle of the waveform.

Description : Compare CRO and DSO. State the formula for phase measurement using CRO with necessary diagram.

Last Answer : CRO DSO Directly reads analog voltage and displays it on screen. It reads the analog voltage and converts it into digital form before being displayed on the screen. ... algorithms available and ported on microprocessor which can operate on stored samples of input voltage.

Description : Explain measurement of phase and frequency using Lissajous pattern. Write the formula for each one.

Last Answer : Phase measurement of Lissajous pattern: The phase measurement can be done by using Lissajous figures. The CRO is set to operate in the X- Y mode, then the display obtained on the screen of a ... or sub- multiple of the unknown frequency.  The Lissajous pattern appears stationary.     

Description : Explain the concept of single beam dual trace CRO with its block diagram.

Last Answer : Diagram:   Explanation: The single beam dual trace CRO consists of one electron gun, an electronic switch which switches the two signals to a single vertical amplifier and a single pair of ... Amplifier are identical & have the same delay time, accurate X-Y measurements can be taken. 

Description : Draw block diagram of CRO and explain function of each block of it. 

Last Answer : The functions of various blocks are: 1) CRT: This is cathode ray tube which emits electrons that strike phosphor screen internally to provide visual display of signal. 2) VERTICAL AMPLIFIER ... are two power supplies a high voltage supply for CRT & low voltage supply for all circuits.

Description : Define Lissajous pattern. Explain how Lissajous pattern is useful for frequency and phase measurement.

Last Answer : Lissajous Pattern : The CRO is set to operate in the X- Y mode, when two sine waves of the same frequency are applied to the CRO (One vertical and one horizontal deflection plates) then the display obtained on ... 1. Lissajous pattern for ratio 3:1    2. Lissajous pattern for ratio 3:2  

Description : State and describe different triggering available in CRO

Last Answer : A trigger is an external signal or input signal condition that initiates one or more instrument functions. Trigger settings include digital edges, software functions, and analog levels. This tutorial ... the external trigger input. The following figure shows an entering window trigger.  

Description : Draw the basic block diagram of single trace CRO and describe the function of delay line.

Last Answer : Function of Delay line: This block is used to delay the signal for a period of time in the vertical section of CRT. The input signal is not applied directly to the vertical plates because the part ... when the delay time is not used. Therefore, the input signal is delayed by a period of time. 

Description : State the difference between CRO and DSO.

Last Answer : CRO DSO Direcly reads analog voltage and displays it on screen. It reads the analog voltage and converts it into digital form before being displayed on the screen. ... DSP algorithms available and ported on microprocessor which can operate on stored samples of input voltage. 

Description : List different types of CRO probes

Last Answer : 1. Passive probes 2. Active probes 3. High voltage probes 4. Current probes 5. Differential probes

Description : Draw and describe horizontal deflection system in CRO 

Last Answer : Block Diagram: Explanation: Input from vertical amplifier is given to Horizontal system. Trigger circuit: a. A trigger circuit is used to convert the incoming signal into trigger ... : Horizontal amplifier amplifies the signal & passes the signal to horizontal plates of CRT. 

Description : Sketch block diagram of single trace CRO. State function of delay line.

Last Answer : Function of Delay line: This block is used to delay the signal for a period of time in the vertical section of CRT. The input signal is not applied directly to the vertical plates because the part ... when the delay time is not used. Therefore, the input signal is delayed by a period of time.

Description : Give any four points of comparison between dual trace CRO & dual beam CRO.

Last Answer : Sr.N o Single Beam Dual Trace CRO Dual Beam Dual Trace CRO 1 A single electron beam is used to display two traces.  Two electron beams are used for displaying two traces/signals. ... two traces is very simple in Dual Beam oscilloscope. 6 Cost is less  Cost is high

Description : List four controls on front panel of dual trace CRO. 

Last Answer : (i)X-shift on CRO: Controls the horizontal position of the display i.e moves the spot across the screen left and right. ii) CT MODE Button on CRO: To test different components iii) Symmetry knob on ... Button on CRO: In DUAL, operates as a DUAL trace scope in ALT or CHOP mode as selected.

Description : List four applications of CRO.

Last Answer : Applications of CRO: 1. It is used in laboratory for measurement of AC/DC voltage, current, frequency, phase and study nature of waveform. 2. It is used in TV receiver for creation of ... modulation percentage of modulated wave. 10. It is also used to check radiation pattern generated by antenna.

Description : State need of delay line in CRO. 

Last Answer : The delay line is used in CRO to delay the signal for some time in thevertical sections. As horizontal channel consists of trigger circuit andtime based generator. This causes more time to reach ... vertical plates. For synchronization of reachinginput signal at same time to both the plates in CRT. 

Description : Sketch Block diagram of vertical deflection system used in CRO.

Last Answer : Block diagram of vertical deflection system used in CRO

Description : Sketch DC signal conditioning circuit for pressure measurement using strain gauge. Justify it.

Last Answer : Diagram: Figure: DC signal conditioning circuit for pressure measurement using strain gauge Where, Rg= strain gauge resistance. Explanation: In order to measure strain with ... millivolts output per volt input. The Wheatstone circuit is also well suited for temperature compensation.

Description : State need of level measurement.

Last Answer : In almost all industries, vast quantities of liquid such as water solvents, chemicals etc. are used in number of processes. It is widely employed to monitor as well as measure ... and therefore its measurement becomes important in a variety of processes encountered in modern manufacturing plants.

Description : Sketch and describe pressure measurement system for 800 mm pressure, that contain Bourdon tube and LVDT.

Last Answer : Diagram: Explanation: The pressure measurement using bourdon tube and LVDT is shown in above figure. In this the, the bourdon tube act as primary transducer and LVDT which follows ... This set up is used for measurement of pressure which is converted into electrical signal by LVDT.

Description : Describe working principle of radiation level measurement with neat diagram.

Last Answer : Radiation type level measurement. Is non contact type detector which is used where electrical method would not survive. working principle 1.It consist of gamma ray source holder on one side ... 7. Thus, when liquid level rises, the amount of radiation received is reduced and vice versa.

Description : Define the term ‘Measurement’.

Last Answer : Measurement is the result or act of a quantitative comparison between a predetermined standard and an unknown magnitude. Or Measurement is the result of an opinion formed by one or more observers about the relative size or intensity of some physical quantity.

Description : Draw block diagram of digital frequency meter in time mode and describe its operation.

Last Answer : OR Operation: The input signal is amplified and converted to a square wave by a Schmitt Trigger circuit. In this diagram the square wave is differentiated and clipped to ... thereby closing it. The decimal counter and display unit output correspond to the number of input pulses. 

Description : State applications of digital frequency meter.

Last Answer : 1. For testing radio equipment 2. Measuring the temperature, pressure, and other physical values. 3. Measuring vibration, strain 4. Measuring transducers

Description : Draw block diagram of frequency meter and state it’s principle of operation

Last Answer : Block diagram Principle  The signal may be amplified before being applied to the Schmitt trigger. The Schmitt trigger converts the input signal into a square wave with fast rise and fall times, ... time interval between start and stop gate then, frequency of unknown signalis, f = N / t

Description : Suggest instrument to measure unknown frequency above 5 MHz and store result. Justify it.

Last Answer : For measurement of frequency CRO, DSO SPECTRUM ANALYZER & FREQUENCY COUNTER can be used. In above specification we can used CRO & DSO for measurement, but the data has to be stored so we ... width or higher bandwidth can be used. Because DSO has measurement facility as well as storage facility.

Description : Draw block diagram of Dual slope integrating voltmeter and also draw waveform for voltage V/s time. 

Last Answer : Block diagram

Description : Describe with suitable example; frequency measurement by Lissajous patterns on CRO. 

Last Answer : * Initially the unknown frequency signal is connected to vertical deflection plates of CRO. * Now switch of the internal sweep generator of the horizontal deflecting system. * A standard source ... explain by following example: Assume horizontal input frequency is 10 kHz for following pattern

Description : Draw and state how Aryton shunt type DC ammeter . State advantage of using Aryton shunt.

Last Answer : OR The Aryton shunt eliminates the possibility of having the meter in the circuit without a shunt. This advantage is gained at the price of slightly higher overall Aryton shunt ammeter. In this ... between shunts. 3. Another advantage is that it may be used as a wide range ammeter. 

Description : Describe working of A.C. voltmeter using half wave rectifier with neat circuit diagram. 

Last Answer : AC Voltmeter using Half Wave Rectifier : The a.c. voltmeter using half wave rectifier is achieved by introducing a diode in a basic d.c. voltmeter. This is shown in the Fig. 1. The diode D ... can be obtained for a.c. voltmeter as, Where Idc is the full scale deflection current..

Description : State any four precautions to be taken while using an Ammeter and Voltmeter. 

Last Answer : Precautions to be taken while using Ammeters: Ammeters are to be connected in series of circuits. 1. While connecting ammeters across emf source always a series resistance should be used. This ... first &then range should be decreased. 4. Loading effect can be minimized by using high sensitivity

Description : Draw Q meter circuit of series connection and explain it.

Last Answer : Q meter circuit of series connection OR Explanation The Q meter works on series resonant. The resonance is the condition exists in the circuit when their inductance and capacitance reactance are ... . Hence E=Q Ec so ,the voltmeter is calibrated for finding the value of Q factor.  

Description : Draw block diagram of distortion factor meter and explain its operation.

Last Answer : Block Diagram Operation This meter consist following four sections 1. Impedance converter along with input circuit 2. Rejection amplifier 3. Metering circuit 4. Power circuit 1. ... of the total input voltage. 4. The power supply unit provides the supply for proper operation 

Description : Draw block diagram of RF signal generator and explain its operation.

Last Answer : RF signal generator contains three other main sections: 1.OSCILLATOR CIRCUIT, 2. MODULATOR, 3. OUTPUT CONTROL CIRCUIT. The modulator modulates the RF signal of the ... . Metal shielding surrounds the unit to prevent signals from the oscillator from affecting the circuit under test

Description : Explain sensitivity and loading effect in voltmeter.

Last Answer : Sensitivity: The sensitivity of a voltmeter is just its capability to detect voltage, usually meaning smaller and smaller voltages. When selecting a meter for a certain voltage measurement, it is ... called loading effect of the voltmeters. It is mainly caused due to low sensitivity instruments.

Description : Draw the construction and explain working principle of PMMC instruments

Last Answer : Working: When current passes through the coil a deflecting torque is produced. This deflecting torque is produced due to interaction between magnetic field produced by permanent magnet ... equilibrium; this is possible only when the controlling torque becomes equal to the deflecting torque 

Description : Draw and explain block diagram of Horizontal deflection system. 

Last Answer :  Trigger circuit: A trigger circuit is used to convert the incoming signal into trigger pulses, so that the input signal and the sweep frequency can be synchronized. The trigger circuit is ... before it is applied to the horizontal section. The block consists of a push- pull amplifier  

Description : Explain gross error, systematic error and random error.

Last Answer : 1) Gross Errors -These errors occur due to human mistakes while taking reading, handling instrument, incorrect setting or adjustment and improper used of instrument. The complete elimination of gross ... remain since the systematic and gross error are removed. Generally these errors are very small.

Description : Define standards. State and explain classification of standards.

Last Answer : Standards:-Standard is a physical representation of a unit of measurement. A known accurate measure of physical quantity is termed as standard. These standards are used to determine ... used to check components and calibrating laboratory instruments to achieve good accuracy and better performance.

Description : Draw block diagram of digital LCR –Q meter and explain its working.

Last Answer : Block diagram Working The output of LCR-Q meter is given to current to voltage converter, AC amplifier or DC amplifer depending upon position of switch Current to voltage ... /D converter. A/D converter converts analog signal into digital output andfinaaly displayed on display.

Description : Explain block diagram of distortion factor meter and explain how it operates

Last Answer : Fig. Distortion factor meter  Working : Initially the switch S is kept at position 1. The attenuator gets excluded and the bridge T network is adjusted for full suppression of ... is obtained on the meter. Thus the total rms distortion is indicated by the reading of attenuator.

Description : Explain function of each block of logic analyzer with proper block diagram

Last Answer : Explanation: A logic analyser is an electronic instrument that captures and displays multiple signals from a digital system or digital circuit. The normal oscilloscope deals with time domain, spectrum ... When the memory receives a trigger signal, it sends the samples to a CRT display.  

Description : Describe block diagram of spectrum analyzer and explain its working

Last Answer : Fig: Block Diagram of Spectrum analyzer. 1. Spectrum analyzer consists of voltage tune oscillator, mixer, IF amplifier, detector, video amplifier, sweep generator and CRT. 2. The input ... on the screen. 8. In this type the signal are broken down into their individual frequency component.

Description : Explain range extension for analog DC voltmeter.

Last Answer : Explanation A DC voltmeter can be converted into a multirange voltmeter by connecting a number of resistors (multipliers) in series with the meter movement 

Description : Draw and explain construction diagram of average responding voltmeter.

Last Answer : Explain: The basic construction of average responding voltmeter is shown in above fig. at the input side of an unknown voltage to be measured is applied. The blocking capacitor is used to ... is connected in the bridge circuit. The bridge circuit consists of two diodes and two capacitors.  

Description : Draw block diagram of AF sine and square wave generator and explain its working

Last Answer : The AF signal generator, which generates either sine wave or square wave in the range of audio frequencies based on the requirement is called AF Sine and Square wave generator. Its block diagram is shown ... can be used to produce either AF sine wave or AF square wave based on the requirement. 

Description : Explain vertical deflection subsystem with neat diagram.

Last Answer : vertical deflection subsystem The main function of the vertical deflection system is to provide an amplified signal of prope r level toderive the vertical deflection plates without any ... suppression, reduced no nlinear effects because none of the plates are at ground potential. 

Description : Define calibration of instruments. Explain why calibration is needed for measuring instruments.

Last Answer : Calibration - It is a process of estimating the value of a quantity by comparing that quantity with a standard quantity. Need of calibration: - Calibration defines the accuracy and quality ... aim of calibration is to minimize any measurement uncertainty by ensuring the accuracy of test equipment.

Description : Explain the electro-magnetic flow meter with neat sketch and write it’s application. 

Last Answer : Electromagnetic flow meter: Principle of Operation: 1. The operation of an Electro-magnetic flow meter is based upon Faraday's Law, which states that the voltage induced across any conductor as it ... rates. It can be also used for measurement of flow rate of slurries, greasy materials.

Description : Explain the sketches , the working principle of Bourdon tube.

Last Answer : Working principle of Bourdon tube:- C type bourdon tube is made up of an elliptically flattened tube bent in such a way as to produce the C shape as shown in the fig. One ... terms of pressure. The relationship between the displacement of the free end and the applied pressure is nonlinear.