Surge point is the point on the performance curve where a further decrease inflow (typically in the region of 50-70 % of rated capacity) causes instability, resulting in a pulsating flow, which may lead to overheating, failure of bearings due to thrust reversals, or excessive vibration. Bypass valves advents are commonly used to prevent surging.