To send 10% of the main current through a moving coil galvanometer of resistance `99omega`, the shunt required is –

1 Answer

Answer :

To send 10% of the main current through a moving coil galvanometer of resistance `99omega`, the shunt ... `11Omega` C. `10Omega` D. `9.9Omega`

Related questions

Description : A moving coil galvanometer is converted into an ammeter reads upto `0.03 A` by connecting a shunt of resistance `4r` across it and ammeter reads up `0

Last Answer : A moving coil galvanometer is converted into an ammeter reads upto `0.03 A` by connecting a shunt of resistance `4r` ... `0.02A` C. `0.03A` D. `0.04A`

Description : To limit the current flow through a DC voltmeter to as low a value as possible, the moving coil circuit is provided with a/an _____________. A. high series resistance B. high parallel resistance C. series inductor D. external shunt

Last Answer : Answer: A

Description : A galvanometer has resistance of 120 Ω. In order to pass 5% of the main current in it, the value of shunt resistance Rs must be equal to a) 6.3 Ω b) 6 Ω c) 2 Ω d) 2.3 Ω

Last Answer : a) 6.3 Ω

Description : A permanent magnet moving coil instrument gives full scale deflection of 25mA when a voltage of 75mV is applied across it. Calculate: (i) Resistance of shunt required for full scale deflection of 150 A. (ii) Series resistance for full scale deflection of 500 V.

Last Answer : Answer :

Description : In a moving coil galvanometer, the deflection of the coil q is related to the electrical current i by the relation

Last Answer : In a moving coil galvanometer, the deflection of the coil q is related to the electrical current i by the ... theta^(2)` D. `I prop sqrt(theta)`

Description : A moving coil galvanometer has 150 equal divisions. Its current sensitivity is 10-divisions per milliampere and voltage sensitivity is 2 divisions per

Last Answer : A moving coil galvanometer has 150 equal divisions. Its current sensitivity is 10-divisions per milliampere and voltage ... `10^(3)` D. `10^(5)`

Description : A galvanometer of 65 Ω resistance gives full scale deflection with 4 mA current. In order to convert it into ammeter, the range of 10 A is connected with it, the shunt resistance should be a) 0.1 Ω b) 0.2 Ω c) 0.06 Ω d) 0.03 Ω

Last Answer : d) 0.03 Ω

Last Answer : A moving-coil permanent-magnet instrument can be used as ammeter by using a low resistance shunt.

Description : A galvanometer has a coil of resistance `100 Omega` and gives a full-scale deflection for `30 mA` current. If it is to work as a voltmeter of `30 V` r

Last Answer : A galvanometer has a coil of resistance `100 Omega` and gives a full-scale deflection for `30 mA` current. ... Omega` C. `1000 Omega` D. `1800 Omega`

Description : The coil of a moving coil galvanometer has an effective area of 4xx10^(-2)m^(2)`. It is suspended in a magnetic field of `5xx10^(-2)` Wb `m^(-2)`. If

Last Answer : The coil of a moving coil galvanometer has an effective area of 4xx10^(-2)m^(2)`. It is suspended in a ... D. current sensitivity is `40 deg` `A^(-1)`

Description : In order to increase the sensitivity of a moving coil galvanometer, one should decrease

Last Answer : In order to increase the sensitivity of a moving coil galvanometer, one should decrease A. the strength of ... in its coil D. the area of its coil

Description : The pole faces of U-shaped magnet in a moving coil galvanometer are made concave to a) decrease the strength of magnetic field b) create a non-uniform magnetic field c) make the magnetic field radial d) All of these

Last Answer : c) make the magnetic field radial

Description : What happens when the shunt resistance of a galvanometer circuit is increased?  (A) Its current sensitivity increases. (B) Its current sensitivity decreases. (C) It’s damping increases. (D) It’s controlling torque increases.  

Last Answer : current sensitivity increase

Description : Current range extension in moving coil instruments can be achieved by placing a ___ in shunt with the instrument.

Last Answer : low resistance resistor

Description : Assertion current sensitivity of a galvanometer is directley proportionall to the current through the coil. Reason Voltage sensitivity is inversely pr

Last Answer : Assertion current sensitivity of a galvanometer is directley proportionall to the current ... sensitivity is inversely proportional to voltage.

Description : The current I passing through the galvanometer coil is related to the angle of deflection θ as a) I ∝ θ b) I 1/∝ θ c) I ∝ θ 2 d) I 1/∝ θ 2

Last Answer : a) I ∝ θ

Description : In a ammeter `0.2%` of main current passes through the galvanometer. If resistance of galvanometer is `G`, the resistance of ammeter will be

Last Answer : In a ammeter `0.2%` of main current passes through the galvanometer. If resistance of galvanometer is `G`, the ... 1)/(500)G` D. `(500)/(499)G`

Description : Which one of the following is the way in which a galvanometer is converted into a voltmeter? Is it by connecting: w) a high resistance coil in parallel with its moveable coil x) a low resistance ... coil in series with its moveable coil z) a low resistance coil in series with its moveable coil 

Last Answer : ANSWER: Y -- A HIGH RESISTANCE COIL IN SERIES WITH ITS MOVEABLE COIL 

Description : A galvanometer having resistance of `50 Omega` requires a current of `100 Omega A` to given full scale deflection. How much resistance is required to

Last Answer : A galvanometer having resistance of `50 Omega` requires a current of `100 Omega A` to given full scale ... in series D. `10^(5)Omega` in parallel

Description : A galvanometer with 20 ohms coil resistence has a full-scale deflection of 10 mA. A 0.02 ohm is placed across the meter to increase its rating capacity. What is the new full scale current for the meter?

Last Answer : False.

Description : The simplest method of controlling the terminal voltage of compound-wound DC generator is with a _____________. A. hand-operated field rheostat connected in series with the shunt field circuit B. ... in series with the load D. balance coil diverting neutral current through the shunt field

Last Answer : Answer: A

Last Answer : An Aryton shunt is used to make a D'Arsonval galvanometer into a multi range ammeter.

Description : Which of the listed electrical devices is represented by the symbol shown in the illustration? EL-0055 A. Fixed resistance resistor B. Coil with magnetic core C. DC motor or generator shunt field D. Transformer

Last Answer : Answer: D

Description : When a resistor is used as a shunt and is connected in parallel with a meter movement coil, it will provide _____________. A. a measurement of circuit resistance B. an increased accuracy of approximately 1.5 percent C. an extended meter range D. none of the above

Last Answer : Answer: C

Description : A d.c. shunt motor runs at no load speed of 1140 r.p.m. At full load, armature reaction weakens the main flux by 5% whereas the armature circuit voltage drops by 10%. The motor full load speed in r.p.m. is (A) 1080 (B) 1203 (C) 1000 (D) 1200

Last Answer : (A) 1080

Description : When using a megohmmeter to determine which shunt field coil is grounded in a DC machine, you must ____________. A. insulate the field frame from the ship's hull B. disconnect each shunt ... C. use a motor driven high capacity megohmmeter D. remove all main line lead connections before testing

Last Answer : Answer: B

Description : A galvanometer having internal resistance `10 Omega` required `0.01` A for a full scale deflection. To convert this galvanometer to a voltmeter of ful

Last Answer : A galvanometer having internal resistance `10 Omega` required `0.01` A for a full scale deflection. ... Omega` in series D. `12010 Omega` in parallel

Description : Calculate the resistance of shunt required to make a milliammeter which gives maximum deflection for a current of 15 mA and which has a resistance of 5 Ω; read up to 10 Amp.

Last Answer : Answer :

Description : The pole pieces of the magnet used in a pivoted coil galvanometer are

Last Answer : The pole pieces of the magnet used in a pivoted coil galvanometer are A. plane surfaces of a ... magnet D. cylindrical sufaces of a horse-shoe magnet

Description : Aboard ship, a grounded field coil in an AC motor can be determined by using a _________________. A. portable growler B. galvanometer C. visual inspection D. megohmmeter

Last Answer : Answer: D

Description : In a galvanometer, what two methods are used to indicate the amount of coil rotation?

Last Answer : The pointer arrangement and the light and mirror arrangement.

Description : What physical component of a galvanometer provides the restoring force for the coil?

Last Answer : Phosphor bronze ribbons.

Description : In a galvanometer, what two methods are used to indicate the amount of coil rotation?

Last Answer : he pointer arrangement and the light and mirror arrangement.

Description : What physical component of a galvanometer provides the restoring force for the coil?

Last Answer : Phosphor bronze ribbons.

Description : A galvanometer in which the coil quickly comes to rest is called a ________ galvanometer a) Ballistic b) Mirror c) Astatic d) Dead beat

Last Answer : d) Dead beat

Description : Sensitivity of a galvanometer can be increased by a) Increasing the number of turns of the coil b) Decreasing the magnetic field c) Increasing the ratio c ⁄BAN d) Decreasing the area of the coil

Last Answer : a) Increasing the number of turns of the coil

Description : An open shunt field in a direct current machine may be located by connecting the field circuit to an external power source, equal to the rated field voltage or less, and tested with a voltmeter from ... C. any suitable ground to any available line lead D. any field pole to each field coil lead

Last Answer : Answer: A

Description : One method of testing for a reversed shunt field coil in a DC generator or motor is by connecting the field to a direct current source, at reduced field rated voltage, and test for ... placed near each field C. test lamp across adjacent fields D. copper jumper across the interpole connections

Last Answer : Answer: B

Description : The scale of a galvanometer of resistance `100 ohms` contains 25 divisions. It gives a defelction of one division on passing a current of `4xx 10 ^(-4

Last Answer : The scale of a galvanometer of resistance `100 ohms` contains 25 divisions. It gives a defelction of one division ... is A. 150 B. 170 C. 110 D. 220

Description : The device used ' for the measurement of current, voltage and resistance is: A. AVO meter B. Galvanometer C. Ammeter D. Ohm meter

Last Answer : ANSWER: A

Description : Instruments of Measure The device used ' for the measurement of current, voltage and resistance is: A. AVO meter B. Galvanometer C. Ammeter D. Ohm meter

Last Answer : ANSWER: A

Description : The device used ' for the measurement of current, voltage and resistance is: A. AVO meter B. Galvanometer C. Ammeter D. Ohm meter

Last Answer : ANSWER: A

Description : The device used ' for the measurement of current, voltage and resistance is: A. AVO meter B. Galvanometer C. Ammeter D. Ohm meter

Last Answer : ANSWER: A

Description : A galvanometer is an instrument used to measure ___________. A. thickness of galvanized metal B. resistance of electrical wiring insulation C. very small amounts of current or voltage D. quantity of galvans in an electric circuit

Last Answer : Answer: C

Description : A multipurpose instrument for measuring current, potential difference and resistance is a) Ohmmeter b) Astatic galvanometer c) Rheostat d) AVO Meter

Last Answer : d) AVO Meter

Description : A small swamping resistance is connected in series with operating coil of a moving coil ammter in order to compensate for the effects of ____

Last Answer : temperature variation

Description : A permanent magnet moving coil ammeter has a coil resistance of 99 ohm and Full Scale Deflection (FSD) current of 0.1mA. Shunt resistance is 1 ohm. Current through the meter at 0.5 F.S.D is:

Last Answer : A permanent magnet moving coil ammeter has a coil resistance of 99 ohm and Full Scale Deflection (FSD) current of 0.1mA. Shunt resistance is 1 ohm. Current through the meter at 0.5 F.S.D is: 0.05mA

Description : A moving coil instrument has a resistance of 10 W and gives full scale deflection when carrying a current of 50 mA. To measure current upto 100 A, we will have to connect • 10 W resistance in series • 10 W resistance in parallel • 10/1999 W resistance in series • 10/1999 W resistance in parallel

Last Answer : A moving coil instrument has a resistance of 10 W and gives full scale deflection when carrying a current of 50 mA. To measure current upto 100 A, we will have to connect 10/1999 W resistance in parallel

Description : A moving coil meter has a resistance of 3 Ω and gives full scale deflection with 30 mA. To measure voltage up to 300 V, the external resistance to be connected in series with the instrument is (A) 9997 Ω (B) 10000 Ω (C) 997 Ω (D) 10003 Ω

Last Answer : A moving coil meter has a resistance of 3 Ω and gives full scale deflection with 30 mA. To measure voltage up to 300 V, the external resistance to be connected in series with the instrument is 9997 Ω

Description : A moving coil instrument of resistance 5 Ohm requires a potential difference of 75 mV to give a full scale deflection. The value of shunt resistance needed to give a full scale deflection at 30 A is

Last Answer : A moving coil instrument of resistance 5 Ohm requires a potential difference of 75 mV to give a full scale deflection. The value of shunt resistance needed to give a full scale deflection at 30 A is 2.5 milliOhm