Current range extension in moving coil instruments can be achieved by placing a ___ in
shunt with the instrument.

1 Answer

Answer :

low resistance resistor

Related questions

Description : What is the typical full-scale deflection current of a moving coil instrument?

Last Answer : 50mA

Description : In a moving coil ammeter, a ___ is connected in series with the coil to compensate for temperature variations

Last Answer : swamping resistors

Description : Permanent-magnet moving coil instrument can be used in

Last Answer : dc work only

Description : What is the reason why the scale of a permanent-magnet moving coil instrument is uniform?

Last Answer : because it is spring controlled

Description : Induction type instruments are mostly used as ___

Last Answer : watt-hour meter

Description : A moving system force in an analog instruments which causes the moving system to deflect from its zero position.

Last Answer : deflecting force

Description : A moving system force in analog instruments which ensures that the deflection of the pointer for a given value of measured quantity always has the same value

Last Answer : controlling force

Description : Which of the following forces does not act on the moving systems of analog instruments?

Last Answer : an electrostatic force

Description : A small swamping resistance is connected in series with operating coil of a moving coil ammter in order to compensate for the effects of ____

Last Answer : temperature variation

Description : Meters with moving coil are normally used for measuring ____

Last Answer : dc only

Description : What is the typical full-scale voltage across a moving coil voltmeter?

Last Answer : 50mV

Description : Moving-iron instrument has a/an scale

Last Answer : squared

Description : As the deflection of the moving system increases, the controlling torque in an indicating instrument.

Last Answer : increases

Description : A force in analog instrument which quickly brings the moving system to rest in its final position.

Last Answer : damping force

Description : A device or instrument, which delivers signals of precise frequency and amplitude, usually over a wide range

Last Answer : signal generators

Description : This instrument measures temperatures by electric means, especially temperatures beyong the range of mercury thermometers

Last Answer : pyrometer

Description : In an oscilloscope, ___ adjusts the brightness of the spot by chaning the current on the control grid.

Last Answer : intensity control

Description : For a dynamometer to be able to measure high current, a ___ should be used.

Last Answer : current transformer

Description : Decreasing the value of the shunt resistor of an ammeter, it current measuring capability

Last Answer : increases

Description : An ammeter has a full-scale deflection current of 100mA. If the same ammeter is used to measure a full-scale current of 1.0ampere, what is the value of the shunt resistor in ohms if the voltage across the meter is 9.0 volts?

Last Answer : 10 ohms

Description : A permanent magnet moving coil instrument gives full scale deflection of 25mA when a voltage of 75mV is applied across it. Calculate: (i) Resistance of shunt required for full scale deflection of 150 A. (ii) Series resistance for full scale deflection of 500 V.

Last Answer : Answer :

Last Answer : A moving-coil permanent-magnet instrument can be used as ammeter by using a low resistance shunt.

Description : A galvanometer with 20 ohms coil resistence has a full-scale deflection of 10 mA. A 0.02 ohm is placed across the meter to increase its rating capacity. What is the new full scale current for the meter?

Last Answer : False.

Description : An instrument used to detect and measure the presence of electrical current is generally called

Last Answer : galvanometer

Description : An instrument used for measuring the amount of current flowing in a circuit.

Last Answer : ammeter

Description : ___ has a series RC combination in one arm and a parallel RC combination in the adjoining arm and used as a notch filter in harmonic distortion analyzer.

Last Answer : wein bridge

Description : When the capacitors of a Wein Bridge are replaced by inductors, the bridge becomes ___

Last Answer : Wein Inductance Bridge

Description : For amplitude measurements, ___ scale is calibrated in either volts per centimeter (V/cm), or millivolts per centimeter (mV/cm)

Last Answer : vertical

Description : When the meter is unsufficiently damped, it is considered as ___

Last Answer : underdamped

Description : ___ ammeter is used to measure high-frequency currents.

Last Answer : thermocouple

Description : A wheatstone bridge is balanced if ___

Last Answer : the ratio of resistors on one side of the bridge equals the ratio of resistors on the other side

Description : In VTVMS, ___ refers to the smallest signal that can be reliably measured

Last Answer : sensitivity

Description : The time interval that a waveform is high (or low) is the ___ of the signal.

Last Answer : pulse width

Description : The time interval between pulses is called ___

Last Answer : pulse delay

Description : A measure of consistency or repeatability of measurements is called. ___

Last Answer : precision

Description : ___ is used for measuring medium Q coils

Last Answer : Maxwell Bridge

Description : Error in voltmeter is due to ___

Last Answer : loading

Description : For time measurements, ___ scale of the scope is used.

Last Answer : horizontal

Description : High sensitive DC voltmeter provides accurate reading when measuring ___ circuits.

Last Answer : high resistance

Description : High sensitive DC voltmeter provides accurate reading when measuring ___ circuits.

Last Answer : high resistance

Description : The ___ provides the visual display showing the form of the signal applied as a waveform on the front screen of a cathode ray oscilloscope

Last Answer : CRT

Description : ___ meter is the most sensitive

Last Answer : 1uA

Description : Calculate the shunt resistance needed to increase the FSD of an ammeter 5 times if the meter resistance is 1kohm

Last Answer : 250ohms

Description : Electrostatic instruments are exclusively used as

Last Answer : voltmeters

Description : Electrostatic instruments are exclusively used as

Last Answer : voltmeters

Description : Which electrical instruments below is the most sensitive?

Last Answer : PMMC

Description : Attraction and repulsion instruments are considered

Last Answer : moving iron instruments

Description : Errors due to frictions of the meter movement, incorrect spring tension, improper calibration or faulty instruments:

Last Answer : instrument errors

Description : How can electric currents be induced with a coil and a magnet?

Last Answer : by moving either the magnet or the coil

Description : To send 10% of the main current through a moving coil galvanometer of resistance `99omega`, the shunt required is –

Last Answer : To send 10% of the main current through a moving coil galvanometer of resistance `99omega`, the shunt ... `11Omega` C. `10Omega` D. `9.9Omega`