A moving coil galvanometer has 150 equal divisions. Its current sensitivity is 10-divisions per milliampere and voltage sensitivity is 2 divisions per

1 Answer

Answer :

A moving coil galvanometer has 150 equal divisions. Its current sensitivity is 10-divisions per milliampere and voltage ... `10^(3)` D. `10^(5)`

Related questions

Description : Assertion current sensitivity of a galvanometer is directley proportionall to the current through the coil. Reason Voltage sensitivity is inversely pr

Last Answer : Assertion current sensitivity of a galvanometer is directley proportionall to the current ... sensitivity is inversely proportional to voltage.

Description : In order to increase the sensitivity of a moving coil galvanometer, one should decrease

Last Answer : In order to increase the sensitivity of a moving coil galvanometer, one should decrease A. the strength of ... in its coil D. the area of its coil

Description : Sensitivity of a galvanometer can be increased by a) Increasing the number of turns of the coil b) Decreasing the magnetic field c) Increasing the ratio c ⁄BAN d) Decreasing the area of the coil

Last Answer : a) Increasing the number of turns of the coil

Last Answer : If we increase the current sensitivity of a galvanometer the voltage sensitivity will Decrease.

Description : In a moving coil galvanometer, the deflection of the coil q is related to the electrical current i by the relation

Last Answer : In a moving coil galvanometer, the deflection of the coil q is related to the electrical current i by the ... theta^(2)` D. `I prop sqrt(theta)`

Description : To send 10% of the main current through a moving coil galvanometer of resistance `99omega`, the shunt required is –

Last Answer : To send 10% of the main current through a moving coil galvanometer of resistance `99omega`, the shunt ... `11Omega` C. `10Omega` D. `9.9Omega`

Description : The scale of a galvanometer of resistance `100 ohms` contains 25 divisions. It gives a defelction of one division on passing a current of `4xx 10 ^(-4

Last Answer : The scale of a galvanometer of resistance `100 ohms` contains 25 divisions. It gives a defelction of one division ... is A. 150 B. 170 C. 110 D. 220

Description : The coil of a moving coil galvanometer has an effective area of 4xx10^(-2)m^(2)`. It is suspended in a magnetic field of `5xx10^(-2)` Wb `m^(-2)`. If

Last Answer : The coil of a moving coil galvanometer has an effective area of 4xx10^(-2)m^(2)`. It is suspended in a ... D. current sensitivity is `40 deg` `A^(-1)`

Description : A moving coil galvanometer is converted into an ammeter reads upto `0.03 A` by connecting a shunt of resistance `4r` across it and ammeter reads up `0

Last Answer : A moving coil galvanometer is converted into an ammeter reads upto `0.03 A` by connecting a shunt of resistance `4r` ... `0.02A` C. `0.03A` D. `0.04A`

Description : The pole faces of U-shaped magnet in a moving coil galvanometer are made concave to a) decrease the strength of magnetic field b) create a non-uniform magnetic field c) make the magnetic field radial d) All of these

Last Answer : c) make the magnetic field radial

Description : A permanent magnet moving coil instrument gives full scale deflection of 25mA when a voltage of 75mV is applied across it. Calculate: (i) Resistance of shunt required for full scale deflection of 150 A. (ii) Series resistance for full scale deflection of 500 V.

Last Answer : Answer :

Description : A galvanometer with 20 ohms coil resistence has a full-scale deflection of 10 mA. A 0.02 ohm is placed across the meter to increase its rating capacity. What is the new full scale current for the meter?

Last Answer : False.

Description : In the reverse biased p-n junction, the current is of the order of (a) Ampere (b) Milliampere (c) Microampere (d) Nano-ampere

Last Answer : (d) Nano-ampere

Description : A galvanometer has a coil of resistance `100 Omega` and gives a full-scale deflection for `30 mA` current. If it is to work as a voltmeter of `30 V` r

Last Answer : A galvanometer has a coil of resistance `100 Omega` and gives a full-scale deflection for `30 mA` current. ... Omega` C. `1000 Omega` D. `1800 Omega`

Description : The current I passing through the galvanometer coil is related to the angle of deflection θ as a) I ∝ θ b) I 1/∝ θ c) I ∝ θ 2 d) I 1/∝ θ 2

Last Answer : a) I ∝ θ

Description : An analog voltmeter has a sensitivity of 10kΩ/volt. The galvanometer used in constructing the instrument will produce a full scale deflection when the current passed through it is  (a) 10 mA (b) 20 mA (c) 50 mA (d) 100 μA

Last Answer : An analog voltmeter has a sensitivity of 10kΩ/volt. The galvanometer used in constructing the instrument will produce a full scale deflection when the current passed through it is 100 μA

Description : The desired sensitivity of a bubble tube with 2 mm divisions is 30". The radius of the bubble tube should be (A) 13.75 m (B) 3.44 m (C) 1375 m (D) None of these

Last Answer : (A) 13.75 m

Description : (True or False) The larger the current required to produce full-scale deflection of the meter coil, the better the sensitivity of the meter.

Last Answer : False.

Description : Which one of the following is the way in which a galvanometer is converted into a voltmeter? Is it by connecting: w) a high resistance coil in parallel with its moveable coil x) a low resistance ... coil in series with its moveable coil z) a low resistance coil in series with its moveable coil 

Last Answer : ANSWER: Y -- A HIGH RESISTANCE COIL IN SERIES WITH ITS MOVEABLE COIL 

Description : Increasing which of the following factors will decrease the density of a radiograph: A. Milliampere B. Time C. KvP Kilovoltage D. Object-film distance E. Focal spot-object distance

Last Answer : E. Focal spot-object distance

Description : The pole pieces of the magnet used in a pivoted coil galvanometer are

Last Answer : The pole pieces of the magnet used in a pivoted coil galvanometer are A. plane surfaces of a ... magnet D. cylindrical sufaces of a horse-shoe magnet

Description : Aboard ship, a grounded field coil in an AC motor can be determined by using a _________________. A. portable growler B. galvanometer C. visual inspection D. megohmmeter

Last Answer : Answer: D

Description : In a galvanometer, what two methods are used to indicate the amount of coil rotation?

Last Answer : The pointer arrangement and the light and mirror arrangement.

Description : What physical component of a galvanometer provides the restoring force for the coil?

Last Answer : Phosphor bronze ribbons.

Description : In a galvanometer, what two methods are used to indicate the amount of coil rotation?

Last Answer : he pointer arrangement and the light and mirror arrangement.

Description : What physical component of a galvanometer provides the restoring force for the coil?

Last Answer : Phosphor bronze ribbons.

Description : A galvanometer in which the coil quickly comes to rest is called a ________ galvanometer a) Ballistic b) Mirror c) Astatic d) Dead beat

Last Answer : d) Dead beat

Description : The device used ' for the measurement of current, voltage and resistance is: A. AVO meter B. Galvanometer C. Ammeter D. Ohm meter

Last Answer : ANSWER: A

Description : Instruments of Measure The device used ' for the measurement of current, voltage and resistance is: A. AVO meter B. Galvanometer C. Ammeter D. Ohm meter

Last Answer : ANSWER: A

Description : The device used ' for the measurement of current, voltage and resistance is: A. AVO meter B. Galvanometer C. Ammeter D. Ohm meter

Last Answer : ANSWER: A

Description : The device used ' for the measurement of current, voltage and resistance is: A. AVO meter B. Galvanometer C. Ammeter D. Ohm meter

Last Answer : ANSWER: A

Description : A galvanometer is an instrument used to measure ___________. A. thickness of galvanized metal B. resistance of electrical wiring insulation C. very small amounts of current or voltage D. quantity of galvans in an electric circuit

Last Answer : Answer: C

Description : Which one of the following is the name of a device used to measure voltage without drawing ANY current from the circuit being measured? Is it: w) a wattmeter x) a galvanometer y) an ammeter z) a potentiometer

Last Answer : ANSWER: Z -- A POTENTIOMETER

Description : An open shunt field in a direct current machine may be located by connecting the field circuit to an external power source, equal to the rated field voltage or less, and tested with a voltmeter from ... C. any suitable ground to any available line lead D. any field pole to each field coil lead

Last Answer : Answer: A

Description : : Moving a coil in and out of magnetic field induces A. force B. potential difference C. e.m.f D. voltage

Last Answer : e.m.f

Description : What is the mathematical formula for computing the output voltage from a moving coil in a magnetic field?

Last Answer : 8. e = Emax sine θ.

Description : What is the typical full-scale voltage across a moving coil voltmeter?

Last Answer : 50mV

Description : A moving coil meter has a resistance of 3 Ω and gives full scale deflection with 30 mA. To measure voltage up to 300 V, the external resistance to be connected in series with the instrument is (A) 9997 Ω (B) 10000 Ω (C) 997 Ω (D) 10003 Ω

Last Answer : A moving coil meter has a resistance of 3 Ω and gives full scale deflection with 30 mA. To measure voltage up to 300 V, the external resistance to be connected in series with the instrument is 9997 Ω

Description : A galvanometer has resistance of 120 Ω. In order to pass 5% of the main current in it, the value of shunt resistance Rs must be equal to a) 6.3 Ω b) 6 Ω c) 2 Ω d) 2.3 Ω

Last Answer : a) 6.3 Ω

Description : A CRO screen has ten divisions on the horizontal scale. If a voltage signal 5 sin 314t+45 deg)is examined with a line base settings of 5 msec/div, the number of cycles of signal displayed on the screen will be a) 0.5 cycles b) 2.5 cycles c) 5 cycles d) 10 cycles

Last Answer : Ans: 2.5 cycles

Description : A galvanometer of 65 Ω resistance gives full scale deflection with 4 mA current. In order to convert it into ammeter, the range of 10 A is connected with it, the shunt resistance should be a) 0.1 Ω b) 0.2 Ω c) 0.06 Ω d) 0.03 Ω

Last Answer : d) 0.03 Ω

Description : To limit the current flow through a DC voltmeter to as low a value as possible, the moving coil circuit is provided with a/an _____________. A. high series resistance B. high parallel resistance C. series inductor D. external shunt

Last Answer : Answer: A

Description : Current range extension in moving coil instruments can be achieved by placing a ___ in shunt with the instrument.

Last Answer : low resistance resistor

Description : What is the typical full-scale deflection current of a moving coil instrument?

Last Answer : 50mA

Description : The induced current can be increased by: a. Using strong magnetic field b. moving loop faster c. Replacing loop by coil d. all of above

Last Answer : d. all of above

Description : A coil is wound with 400 feet of No. 16 tinned copper wire and connected to a 12 volt battery. What is the current if the resistance per 1000 feet of No. 16 tinned copper wire is 4.26 ohms? A. 4.8 amps B. 7.06 amps C. 10.65 amps D. 11.27 amps

Last Answer : Answer: B

Description : A coil is wound with 200 feet of No. 16 tinned copper wire and connected to a 12 volt battery. What is the current if the resistance per 1000 feet of No. 16 tinned copper wire is 4.26 ohms? A. 1.14 amps B. 7.04 amps C. 10.22 amps D. 14.08 amps

Last Answer : Answer: D

Description : A low voltage source is being used for testing armature coils. A coil short circuit will be indicated by a _______. A. high voltage reading, while the other coil readings will have an ... the other coil readings are steady D. steady voltmeter reading, while the other coil readings are fluctuating

Last Answer : Answer: B

Description : The main plate of a transit is divided into 1080 equal divisions. 60 divisions of the Vernier coincide exactly with 59 divisions of the main plate. The transit can read angles accurate upto (A) 5" (B) 10" (C) 15" (D) 20"

Last Answer : (D) 20"

Description : The Q factor of a coil at resonant frequency 1.5 MHz of an RLC series circuit is 150. The Bandwidth is : - a) 225 MHz b) 1.06 MHz c) 10 KHz d) 10 MHz

Last Answer : The Q factor of a coil at resonant frequency 1.5 MHz of an RLC series circuit is 150. The Bandwidth is : - 10 KHz