1 Answer

Answer :

The instrument used normally to check the insulation Megger.

Related questions

Description : Mastic asphalt is normally used for (A) Sound insulation (B) Water proofing (C) Fire proofing (D) None to these

Last Answer : Answer: Option B

Description : A galvanometer is an instrument used to measure ___________. A. thickness of galvanized metal B. resistance of electrical wiring insulation C. very small amounts of current or voltage D. quantity of galvans in an electric circuit

Last Answer : Answer: C

Description : An insulation resistance test is performed on a particular piece of electric equipment. In addition to the resistance reading, what information listed below should be entered in the electrical log? A. ... D. The complete nameplate data from the resistance test instrument used to obtain the reading.

Last Answer : Answer: B

Description : What instrument is used for measuring the insulation resistance of cables?

Last Answer : Megohmmeter (megger).

Description : Resistance measuring instrument particularly used in determining the insulation resistance

Last Answer : Megger/Megaohmmeter

Last Answer : Meggar is an instrument which measures the insulation resistance of an electric circuit relative to earth and one another.

Description : As part of a routine maintenance program for deck machinery, you should ___________. A. inspect electrical wiring and pushbutton switches for evidence of corrosion or burned insulation B. disassemble ... covers and ventilate as weather permits D. Check drum switch contact pressure every three months

Last Answer : Answer: A

Description : On some electrical generating equipment one outboard bearing pedestal is insulated from the bedplate. To check this insulation with the machine assembled you should use a____________. A. millivolt meter and a jumper B. ohmmeter C. megohm meter D. high potential tester

Last Answer : Answer: A

Description : If air gap readings for an electical generating machine have changed significantly from the last reading, you should check _________. A. the bearings B. insulation readings and machine cleanliness C. the prime mover thrust bearing D. the field coil bolts for the proper torque values

Last Answer : Answer: A

Description : If deck machinery is expected to be idle for an extended period of time you should____________. A. have electrical safety gloves available in case of electrical shock before running B. perform ... run at regular intervals to inusre correct operation and to renew the internal coating of lubrication

Last Answer : Answer: D

Description : On some electrical generating equipment one outboard bearing pedestal is insulated from the bedplate. To check this insulation with the machine assembled you should use a____________. A. ohmmeter with the ... C. megohm meter with the machine running D. voltmeter and ampmeter with the machine running

Last Answer : Answer: B

Description : When working on electrical circuits containing large capacitors, in addition to deenergizing the circuit, which of the listed precautions should also be taken? A. Keep all radio equipment ... capacitor insulation resistance. C. Ground the capacitor terminals. D. Check capacitor circuit polarity.

Last Answer : Answer: C

Description : Which of the instruments listed is used to check insulation resistance? A. Magneto B. Megohmmeter C. Dynamometer D. Rheostat

Last Answer : Answer: B

Description : The operator of electrical motors should keep a constant check on the loads they carry because _____________. A. low loads necessitate frequent insulation cleaning B. exceeding nameplate values shortens ... wasted if full loading is not utilized D. power factor correction methods are load dependent

Last Answer : Answer: B

Description : A generator has been exposed to water and is being checked for its safe operation. Therefore, it is necessary to _______________. A. check for shorted coils with a growler B. take moisture readings with a ... a megger D. ground the commutator, or slip rings and run it at half load for 12 hours

Last Answer : Answer: C

Description : What is the procedure for using a megger to check the insulation of a conductor?

Last Answer : Connect one lead to the insulation and one lead to the conductor. Turn the handcrank until it starts to slip. Note the reading

Description : A trad-able form of loan is normally termed as ________ A. Certificate of Deposit (CD) B. Inter Bank term Money C. Bill Re-discounting D. Debt Instrument E. None of the Above

Last Answer : D. Debt Instrument Explanation: A trad-able form of loan is normally termed as a Debt Instrument. They are usually obligations of issuer of such instrument as regards certain future cash flow representing Interest & Principal, which the issuer would pay to the legal owner of the Instrument.

Description : What instrument normally measures the virtual height of ionosphere? A. Ionosonde B. Altimeter C. Field meter D. Radar

Last Answer : A. Ionosonde

Last Answer : The error of an instrument is normally given as a percentage of full-scale value.

Description : Check rails should normally be provided where the radius is …. M or less in B.G. (a) 150m (b) 200m (c) 218m* (d) 240m

Last Answer : (c) 218m*

Description : Check rails should normally be provided where the radius is ……. M or less in B.G. (a) 150m (b) 200m (c) 208m* (d) 225m

Last Answer : (c) 208m*

Description : In order to check the performance of a transistor removed from its circuit, the instrument to be used should be a/an ____________. A. voltmeter or transistor tester B. impedance meter C. ohmmeter or transistor tester D. sensitive potentiometer

Last Answer : Answer: C

Description : To properly use a hook-on-type volt/ammeter to check current flow, you must FIRST _____________. A. de-energize the circuit to allow connection of the instrument in series B. hook the jaws ... test leads to the appropriate terminals D. short the test leads and calibrate the instrument to zero

Last Answer : Answer: B

Description : Select insulating materials for following parts : (i) Insulation between heating element and base plate of electric iron. (ii) Insulation used over copper or aluminium conductor used for making coils. (iii) Transformer bushings. (iv) Insulation between transmission line and pole.

Last Answer : Parts Insulating Materials  Insulation between heating element and base plate of electric iron. Mica Insulation used over copper or aluminium conductor used for making coils.  ... Transformer bushings Porcelain  Insulation between transmission line and pole. Porcelain

Description : Name the method used to measure following resistances:- (i) Low resistance (ii) Medium resistance (iii) Insulation resistance (iv) Earth resistance.

Last Answer : Following are the methods used to measure resistances:-  (i) Low resistance: 1.Voltmeter-Ammeter Method 2. Kelvin's Double bridge Method  (ii) Medium resistance: 1.Voltmeter-Ammeter Method 2. ... of Charge Method  (iv) Earth resistance : 1. Fall of Potential Method 2. Earth tester

Description : In a 3-phase extra-high voltage cable, a metallic screen around each core insulation is provided to  (a) Facilitate heat dissipation (b) Give mechanical strength (c) Obtain longitudinal electric stress (d) Obtain radial electric stress 

Last Answer : In a 3-phase extra-high voltage cable, a metallic screen around each core insulation is provided to Give mechanical strength

Description :  The insulation resistance of earth of an installation should be nearly: -  a) 0.1 M ohm b) 0.2 M ohm c) 0.5 M ohm d) 1 M ohm.

Last Answer :  The insulation resistance of earth of an installation should be nearly: - 1 M ohm.

Description : A megger is to measure insulation resistance of a cable. The cable should be connected to   (a) Battery (b) DC supply (c) AC supply (d) No supply  

Last Answer : majorly in DC as well as AC......but ans is Battery

Description : To measure insulation resistance of equipments of voltage rating upto 440 V the megger generator must generate   (a) 220 V (b) 440 V (c) 500 V (d) None of these 

Last Answer : 500 V

Description : The insulation strength of EHV lines is mainly governed by   (a) Switching overvoltages (b) Lightning overvoltages (c) Power frequency overvoltages (d) Dynamic overvoltages 

Last Answer : 1 P

Last Answer :  In RE cable the insulation resistance will be above 20 mega ohms.