An insulation resistance test is performed on a particular piece of electric equipment. In addition to the resistance reading, what information listed below should be entered in the electrical log? A. The maximum allowable operating temperature of the machine. B. The temperature of the machine at the time the resistance reading was taken. C. The normal temperature rise of the machine.  D. The complete nameplate data from the resistance test instrument used to obtain the reading.

1 Answer

Answer :

Answer: B

Related questions

Description : When working on electrical circuits containing large capacitors, in addition to deenergizing the circuit, which of the listed precautions should also be taken? A. Keep all radio equipment ... capacitor insulation resistance. C. Ground the capacitor terminals. D. Check capacitor circuit polarity.

Last Answer : Answer: C

Description : Motor name plate data includes '°°C rise'. This indicates the _____________. A. actual running temperature of the winding from no load to full load B. permissible temperature rise ... above normal full load operating temperature D. maximum allowable temperature rise for continuous no load service

Last Answer : Answer: B

Description : Which of the conditions listed will indicate the need to clean the insulation on the windings of an electric motor? A. Higher than normal operating temperature. B. Excessive vibration at normal speed. C. Sparking at the brushes. D. High megger readings.

Last Answer : Answer: A

Description : The insulation resistance of electric equipment and machinery should be tested for the lowest normal insulation values _____________. A. immediately after shutting down the machine B. every time the brush rigging is ... starting up the machine D. every 30 days whether the machine is in use or not

Last Answer : Answer: A

Description : When you are making a high potential test on a piece of repaired electrical machinery, a rise in leakage current indicates ____________. A. good insulation B. bad insulation C. high insulation power factor D. a high slot discharge factor

Last Answer : Answer: B

Description : The operator of electrical motors should keep a constant check on the loads they carry because _____________. A. low loads necessitate frequent insulation cleaning B. exceeding nameplate values shortens ... wasted if full loading is not utilized D. power factor correction methods are load dependent

Last Answer : Answer: B

Description : Which of the listed conditions could indicate the need for cleaning electrical insulation? A. Low ambient temperature B. Low operating temperature C. High dielectric strength D. Low megger readings

Last Answer : Answer: D

Description : Which of the listed classes of electrical insulation is suited for the highest operating temperature? A. Class 90 (O) B. Class 105 (A) C. Class 130 (B) D. Class 180 (H)

Last Answer : Answer: D

Description : Air gap readings should be taken periodicly on electrical generation equipment to __________. A. determine the amount of varnish that can be applied to correct insulation problems B. determine the ... field coil bolts and correct lateral adjustment of the field coils D. increase machine efficiency

Last Answer : Answer: B

Description : When using a megohmmeter to test insulation, good insulation will be indicated by _____________. A. slight kicks of the needle down scale B. a downward dip followed by a gradual climb to the true resistance ... C. a gradual rise in the pointer reading at the outset D. the initial dip of the pointer

Last Answer : Answer: B

Description : When a megohmmeter is used to test insulation, the gradual rise of the pointer reading as a result of continued cranking, is caused by _____________. A. good conductor resistance B. the ... insulation C. the inductive reactance of the windings D. the dielectric-absorption effect of the insulation

Last Answer : Answer: D

Description : A galvanometer is an instrument used to measure ___________. A. thickness of galvanized metal B. resistance of electrical wiring insulation C. very small amounts of current or voltage D. quantity of galvans in an electric circuit

Last Answer : Answer: C

Description : Which of the listed groups of electrical insulation materials is best suited for the highest operating temperatures? A. impregnated cotton and silk B. unimpregnated paper and cotton C. pure glass and quartz D. mica and porcelain with bonding agents

Last Answer : Answer: C

Description : Which of the listed procedures is the best way to tell if a motor has become overloaded? A. Measure the current flow and compare it with the motor full load current flow as shown on the nameplate. ... Watch for telltale signs of smoke coming from the motor. D. Periodic opening of the O/L relay coil

Last Answer : Answer: A

Description : You are testing the insulation in an AC generator with a megohmeter. The resistance value of a dry, clean winding will ____________. A. continue to rise as the test potential is maintained, ... fairly steady after 5 to 7 minutes D. stabilize after approximately 2 to 4 minutes of fluctuation

Last Answer : Answer: A

Description : One item listed on the name plate of a cargo pump motor is 'degrees centigrade rise.' This number is based on _____________. A. normal temperature change from cold to hot B. an ambient temperature ... . minimum heat rise from no load to full load D. maximum degrees centigrade rise from absolute zero

Last Answer : Answer: B

Description : On some electrical generating equipment one outboard bearing pedestal is insulated from the bedplate. To check this insulation with the machine assembled you should use a____________. A. millivolt meter and a jumper B. ohmmeter C. megohm meter D. high potential tester

Last Answer : Answer: A

Description : On some electrical generating equipment one outboard bearing pedestal is insulated from the bedplate. To check this insulation with the machine assembled you should use a____________. A. ohmmeter with the ... C. megohm meter with the machine running D. voltmeter and ampmeter with the machine running

Last Answer : Answer: B

Description : When a megohmmeter is being used on a alternating current machine, the meter pointer will dip toward 'zero' and then gradually rise to the true resistance value if the motor insulation is _____________. A. grounded B. good C. shorted D. dirty

Last Answer : Answer: B

Description : An insulation resistance reading is taken at 20°C and found to be 10 megohms. What would you expect the resistance reading to be at 40°C? A. 2.5 megohms B. 10 megohms C. 15 megohms D. 20 megohms

Last Answer : Answer: A

Description : An open coil in a transformer will be indicated by which of the listed conditions? A. 'zero' resistance accompanied by high inductance B. no resistance accompanied by stray inductance C. infinite resistance in addition to no inductance D. infinite resistance in addition to normal inductance

Last Answer : Answer: C

Description : Two paralleled alternators are operating near rated load. If one trips out mechanically, which of the listed actions should be taken FIRST? A. Restart the tripped machine immediately. B. Strip the board ... circuits. C. Start the emergency generator. D. Transfer all vital loads to the emergency bus.

Last Answer : Answer: B

Description : When troubleshooting motor controllers, a shorted relay or contactor coil is often indicated by _______________. A. a resistance reading of 'infinity' on an ohmmeter B. charred insulation and/or a blown ... of the coil's leads to ground D. a higher-than-normal voltage reading across the winding

Last Answer : Answer: B

Description : Moisture absorbed in the windings or condensed on the surface of electrical machinery insulation ________. A. is good for long term preserving since most insulation is organic and contains some amount B. ... D. reduces the amount of current supplied or drawn by the machine so horsepower is limited

Last Answer : Answer: B

Description : Before testing insulation with a megohmmeter, the windings of large machines should be grounded for about 15 minutes just prior to the test, because the ___________. A. static charge of the machine ... number of leakage paths C. insulation may be damaged D. insulation may be covered with moisture

Last Answer : Answer: A

Description : When a megohmmeter is being used to test insulation resistance, current leakage along the surface of the insulation is indicated by the megohmmeter pointer _____________. A. fluctuating around a ... slightly downscale as voltage is applied D. continually rising as the test voltage is applied

Last Answer : Answer: C

Description : When a megohmmeter is being used to test insulation resistance, current leakage along the surface of the insulation is indicated by the megohmmeter's pointer _____________. A. dipping toward ... kicking slightly down scale as voltage is applied D. fluctuating around a constant resistance reading

Last Answer : Answer: C

Description : Electrical insulation is classed by the _____________. A. International Association of Electrical Manufacturers B. approximate operating voltage and current expected C. U.S. Coast Guard D. temperature stability of the manufacturing material(s)

Last Answer : Answer: D

Description : The life expectancy of electrical insulation, is approximately halved for an increased operating temperature of _______________. A. 10°C B. 25°C C. 50°C D. 100°C

Last Answer : Answer: A

Description : Cleaning of electrical insulation should be _____________. A. done every six months B. accomplished every 12 months C. determined by need and not the calendar D. performed whenever the electrician is not otherwise busy

Last Answer : Answer: C

Description : The rated temperature rise of an electric motor is the _____________. A. average temperature at any given latitude B. normal temperature rise above the standard ambient temperature at rated load ... D. permissible difference in the ambient temperature of the motor due to existing weather conditions

Last Answer : Answer: B

Description : The piston rod of a hydraulic cylinder exerts an operating force of 10kN. The allowable stress in the cylinder is 45N/mm². Calculate the thickness of the cylinder using Lame's equation. Diameter of the cylinder is 40mm and ... is 10MPa. a) 2.05mm b) 4.2mm c) 5.07mm d) None of the listed

Last Answer : c) 5.07mm

Description : Which of the listed statements is correct when using an analog multimeter as an ohmmeter? A. The pointer should be adjusted to zero each time a new resistance range is selected. B. The ... C. Ohmmeters are not sufficiently sized to measure conductor insulation resistance. D. All of the above.

Last Answer : Answer: D

Description : Which of the listed precautions should be observed before spraying liquid solvent on the insulation of an electric motor? A. Slow the motor down to low speed. B. Disconnect the motor from the power source. C. Secure all ventilation in the area. D. Preheat the insulation to assist in cleaning.

Last Answer : Answer: B

Description : Which of the instruments listed is used to check insulation resistance? A. Magneto B. Megohmmeter C. Dynamometer D. Rheostat

Last Answer : Answer: B

Description : Air gap readings should be taken on electrical generation equipment periodicly to ________. I. check machine effeciency II. determine the need for cleaning A. I only B. II only C. both I and II D. neither I or II

Last Answer : Answer: D

Description : To carry out an insulation resistance test, one terminal of the megohmmeter should be connected to the winding, with the other terminal being connected to the ____________________. A. power supply B. variable resistor C. frame of the machine D. armature

Last Answer : Answer: C

Description : The removal of paint from electrical equipment, such as generators, should be cautiously undertaken because ____________. A. the mechanical shock of paint removal lessens the dielectric strength ... phase windings frequently become isolated from each other due to dust interference at the terminals

Last Answer : Answer: B

Description : The greatest detrimental effect on idle electrical equipment, such as cargo pump motors, is the _____________. A. loss of residual magnetism B. absorption of moisture in the insulation C. insulation varnish flaking D. dirt collecting on the windings

Last Answer : Answer: B

Description : Which of the spaces listed is defined as a 'location requiring an exceptional degree of protection' when considering the installation of shipboard electrical equipment? A. Machinery space B. Chart room C. Console room D. Accommodation space

Last Answer : Answer: A

Description : Which of the listed procedures should be carried out to prevent moisture damage to electrical apparatus during extended periods of idleness? A. Fill the motor housing with CO2 to inert the space. B. Strap ... C. Place heat lamps in the motor housings. D. Cover the equipment with a canvas tarpaulin.

Last Answer : Answer: C

Description : Electrical machinery insulation will break down more rapidly due to _________________. A. low loading of motors and generators B. frequent megger testing C. high temperatures and vibration D. high operating frequencies

Last Answer : Answer: C

Description : Before any work on electrical or electronic equipment is performed, which of the following precautions should be carried out? A. De-energize the applicable switchboard bus. B. Bypass the interlocks. C. ... supply circuit breaker in the open position. D. Station a man at the circuit supply switch.

Last Answer : Answer: C

Last Answer : Meggar is an instrument which measures the insulation resistance of an electric circuit relative to earth and one another.

Description : If air gap readings for an electical generating machine have changed significantly from the last reading, you should check _________. A. the bearings B. insulation readings and machine cleanliness C. the prime mover thrust bearing D. the field coil bolts for the proper torque values

Last Answer : Answer: A

Description : Ambient temperature is the _____________. A. amount of temperature rise with no load B. amount of temperature developed by an operating motor C. temperature of the compartment where the motor is located D. normal operating temperature, less the room temperature

Last Answer : Answer: C

Description : Ambient temperature is the _____________. A. amount of temperature rise with no load B. temperature of the compartment where the motor is located C. normal operating temperature, less the room temperature D. amount of temperature developed by an operating motor

Last Answer : Answer: B