Last Answer : 1. Connected Load: It is the sum of load of all equipment's connected to supply system which are in use or not in use of each consumer. OR   The sum of connected load of all consumers ... is the maximum load which a consumer uses at a particular time period out of his total connected load. 

Description : Define the terms: i) Tariff ii) Fuel surcharge iii) Electricity Duty iv) Connected load

Last Answer : i) Tariff: The rate at which a consumer is charged for the consumption of electricity is called as tariff. OR The amount of money framed by the supplier for the supply of electrical energy ... is the total wattage of all appliances which are used by the consumer on his sanctioned connection. 

Description : Define the following terms related to tariff: (i) Connected load (ii) Unit consumed (iii) Fixed charges (iv) Electricity Tax 

Last Answer : (i) Connected load  It is the sum of the power ratings (Watts or kW or MW) of all devices and machines existing (installed) in the premises of consumer. It is used to decide the ... a percentage of the total electricity bill which includes all amounts that go to the electricity supply agency. 

Description : Define each of following terms: i) Connected load ii) Spinning reserve. 

Last Answer : i) Connected Load :- It is the sum of load of all equipment connected to supply system which are in use or not in use of each consumer. ii) Spinning Reserve:- It is reserved generating capacity in operation and connected to bus bar and ready to take a load.

Description :  A connected graph has ‘5’ number of branches and ‘4’ number of nodes. It's rank is A) 1 B) 2 C) 3 D) 4 

Last Answer :  A connected graph has ‘5’ number of branches and ‘4’ number of nodes. It's rank is 3 

Description : In an R-C phase shift oscillator, the minimum no. of R-C networks to be connected in cascade will be -

Last Answer : In an R-C phase shift oscillator, the minimum no. of R-C networks to be connected in cascade will be 3

Description : Two 100W, 200V lamps are connected in series across a 200V supply. The total power consumed by each lamp will be in Watts

Last Answer : 4800

Description : Three identical resistors connected in star consume 5000 W. If the resistors are connected in delta across the same supply, the power consumed will be

Last Answer : Three identical resistors connected in star consume 5000 W. If the resistors are connected in delta across the same supply, the power consumed will be 15000 W

Description : A four -quadrant operation requires two full converters connected in  (1) Series (3) Back to back (2) Parallel (4) Series Cascade

Last Answer : A four-quadrant operation requires two full converters connected in Parallel 

Description : Consider a circuit with three parallel branches connected across a DC supply. What is the ratio of the branch currents I1 : I2 : I3 if the branch resistances are in the ratio of 2 : 3 : 4 respectively? A) 2 : 3 : 4 B) 6 : 4 : 3 C) 4 : 3 : 2 D) None of these

Last Answer : Consider a circuit with three parallel branches connected across a DC supply. What is the ratio of the branch currents I1 : I2 : I3 if the branch resistances are in the ratio of 2 : 3 : 4 respectively? A) 2 : 3 : 4 B) 6 : 4 : 3 C) 4 : 3 : 2 D) None of these

Description : When three resistors with unequal values are connected in parallel, _______ A) The current across the resistors is the same  B) The voltage drop across the resistors is the same C) The voltage drops across the resistors is proportional to the resistance of each resistor D) None of these

Last Answer : When three resistors with unequal values are connected in parallel, The voltage drop across the resistors is the same

Description : What is the total resistance if 5 resistors of 20 Ω each are connected in series? A) 100 Ω B) 4 Ω C) 20 Ω D) None of these

Last Answer : What is the total resistance if 5 resistors of 20 Ω each are connected in series? A) 100 Ω B) 4 Ω C) 20 Ω D) None of these

Description : The sequence components of current of a single-phase load connected to a 3-phase system are (A) equal positive and negative sequence components (B) equal positive, negative and zero sequence components (C) vector sum of sequence currents is zero (D) algebraic sum of sequence currents is zero

Last Answer : The sequence components of current of a single-phase load connected to a 3-phase system are equal positive, negative and zero sequence components

Description : If non-linear loads are connected to the power system, then (A) displacement power factor is same as the total power factor (B) displacement power factor is not equal to the total power ... factor is due to harmonic currents (D) total power factor is due to fundamental component of current

Last Answer : If non-linear loads are connected to the power system, then displacement power factor is not equal to the total power factor

Description :  With three resistances connected in parallel, if each dissipates 20 W the total power supplied by the voltage source equals?

Last Answer : Power is the only thing which is additive in both connection whether it is parallel or series connection so total power consumed will addition of all individual power =20+20+20 = 60 watt

Last Answer : If a D.C. motor is connected across the A.C. supply it will burn due to heat produced in the field winding by eddy currents.

Last Answer : A fuse is connected in series with circuit.

Description : Cells are connected in series in order to?

Last Answer : Cells are connected in series in order to increase voltage available.

Description : Explain Three Phase Bidirectional Delta Connected Controller.

Last Answer : Three Phase Bidirectional Delta Connected Controller: