How does the emergency generator start automatically?

1 Answer

Answer :

It is activated by a under voltage relay. When there is blackout, the under voltage relay senses loss of voltage and starts up the emergency generator. Similarly when the power is restored, the relay stops the emergency generator. Ask E/) for more details.

Related questions

Description : After a black out the emergency generator comes on; On restoring the main supply we are closing the circuit breaker of the main generator without bothering about synchronizing. How is this possible?

Last Answer : There is a power link connection breaker between the main generator and the emergency generator. During black out, this breaker trips. The emergency generator starts and its breaker closes and feeds only ... , there is no paralleling between main and emergency generator. Ask E/O for more details.

Description : In the illustration, if one of the devices labeled 'TURB' should fail the ___________. EL-0003 A. device labeled 'EXC' will drive the alternator B. device labeled 'BKR' for that ... -alternator D. emergency generator should automatically start and be placed on line to supply emergency load centers

Last Answer : Answer: B

Description : How does the air compressor start and stop automatically?

Last Answer : The air reservoir has pressure switch which is set for cut-off and cut-in depending on the pressure desired. When the pressure drops below the cut-in setting, the switch energises the contactor ... its closed contact in series with the power circuit to contactor and cuts supply to the contactor.

Description : What are the parts of a brushless AC generator?

Last Answer : Yoke, armature, stator, rotor, primary exciter, main exciter, rotary diode rectifier assembly, impeller, bearing & housing, end cover, terminal block, AVR.

Description : What is a shaft generator?

Last Answer : A shaft generator is coupled to the main engine. It uses the main engine as its prime mover and has a frequency converter (thyristor controlled) that converts the variable engine speed to near constant speed and ... speed (full speed) and not at manoeuvring speed. Ask E/O and 2/E for more details.

Description : If the AVR, is defective, when additional loads come on will the generator be able to take it?

Last Answer : No. Ask E/O and refer to Dennis T Hall.

Description : If you press the ACB Close button on an idle generator what will happen?

Last Answer : Ask E/O. Normally, the breaker won’t close until you synchronise, so even if you press the breaker close, it will not close. The breaker has under-voltage protection which will not let you close it.

Description : Which of the following converts electric energy into mechanical energy: a. Transformer b. DC generator c. Motor d. AC generator

Last Answer : d. AC generato

Description : Which component is mainly used in a DC generator: a.slip ring b. commutator c. magnet d. coil

Last Answer : b. commutator

Description : In the plane of AC generator coil is parallel to the field, then emf induced in coil is: a. maximum b. minimum c. zero d. intermediate

Last Answer : b. minimum

Description : Which one is not present in AC generator: a. Armature b. magnet c. slip ring d. commutator

Last Answer : c. slip ring

Description : The most common source of AC voltage is: a. motor b. generator c. cell d. transformer

Last Answer : c. cell

Description : The principle of AC generator is: a. Mutual induction b. self induction c. electromagnetic induction d. Induction

Last Answer : b. self induction

Description : In the plane of the A.C generator coil is perpendicular to the field, then induced emf in the coil is: a. Maximum b. minimum c. zero d. intermediate value

Last Answer : b. minimum

Description : Alternating current generator converts.......... energy into electrical energy? a. mechanical energy b. chemical energy c. solar energy d. potential energy

Last Answer : a. mechanical energy

Description : The Principle of an alternating current generator is based on: a. Coulomb’s law b. Ampere’s law c. Faraday’s law d. Lenz’s law

Last Answer : a. Coulomb’s law

Description : The output waveform produced due to time base generator in a CRO is a) saw tooth b) sinusoidal c) linear d) helical

Last Answer : a) saw tooth

Description : A circuit which develops voltage across the horizontal deflection plates is known as a) Time base generator b) Electron gun c) Thermionic diode d) Zener diode

Last Answer : a) Time base generator

Description : Briefly explain how an electrical generator converts mechanical energy into electrical energy.

Last Answer : Working principle of DC generator: * Working principle of DC generator is the principle of dynamically induced emf or electromagnetic induction. * According to this principle, when flux is cut by a conductor, an ... , the flux is cut by the armature winding and an emf is dynamically induced in it. 

Description : Diesel generators #1 and #2 are operating in parallel at near full load capacity. Diesel generator #1 suddenly trips out mechanically due to low lube oil pressure. The reverse power relay functions ... all nonvital circuits. D. Secure alarms, reset reverse power relay, and restart #1 engine.

Last Answer : Answer: C

Description : Two paralleled alternators are operating near rated load. If one trips out mechanically, which of the listed actions should be taken FIRST? A. Restart the tripped machine immediately. B. Strip the board ... circuits. C. Start the emergency generator. D. Transfer all vital loads to the emergency bus.

Last Answer : Answer: B

Description : What can be possible reasons for a motor failing to start?

Last Answer : No power , Fuse blown , Overload trip, contactor coil burnt , Contactors contacts bad, control circuit relay faulty, stop switch open circuit and start switch does not operate, hold on contact does not make and motor burnt

Description : If all your air bottles are at low pressure and there is a blackout how do you start the generators?

Last Answer : If main air bottles are empty, the emergency air bottle can be used to start the main generator. If even the emergency air bottle is empty, then it can be filled by running emergency air compressor ( ... ). Once the emergency air bottle is filled, this air can be used to start the main generator.

Description : Which proclamation of National Emergency automatically suspends? -General Knowledge

Last Answer : The answer is 'Right to freedom '

Description : Which proclamation of National Emergency automatically suspends? -Do You Know?

Last Answer : Suspension of Fundamental rights under Article 19: According to Article 358, when a proclamation of National Emergency is made, the six fundamental rights under article 19 are automatically suspended. Article 19 is automatically revived after the expiry of the emergency.

Description : Which proclamation of National Emergency automatically suspends? -General Knowledge

Last Answer : Suspension of Fundamental rights under Article 19: According to Article 358, when a proclamation of National Emergency is made, the six fundamental rights under article 19 are automatically suspended. Article 19 is automatically revived after the expiry of the emergency.

Description : Which proclamation of National Emergency automatically suspends? -General Knowledge

Last Answer : Suspension of Fundamental rights under Article 19: According to Article 358, when a proclamation of National Emergency is made, the six fundamental rights under article 19 are automatically suspended. Article 19 is automatically revived after the expiry of the emergency.

Description : Which proclamation of National Emergency automatically suspends?

Last Answer : Right to freedom

Description : Which proclamation of National Emergency automatically suspends?

Last Answer : Right to freedom

Description : Which proclamation of National Emergency automatically suspends?

Last Answer : Right to freedom

Description : An equalizing connection between two compound-wound DC generators when paralleled, serves to _____________. A. reverse the polarity of the incoming generator as the series field weakens B. automatically ... the series field of the incoming generator D. parallel the series fields of the generators

Last Answer : Answer: D

Description : A reverse-current relay will prevent AC generator motorization by ____________. A. automatically redirecting the load B. automatically speeding up the prime mover C. tripping the panel board main switch D. tripping the generator circuit breaker

Last Answer : Answer: D

Description : The 'function generator' of the control circuit illustrated _______________. EL-0095 A. can be programmed to produce a non-linear output for a linear input depending on operating conditions B. is used for ... which or how many engines are needed for a required vessel speed D. all of the above

Last Answer : Answer: A

Description : Can an emergency generator survive an EMP?

Last Answer : I am not sure what you are asking is an EMP. Emergency generators are powerful and very helpful if power is lost but I am not sure if they can withstand that as I am not sure what they are.

Description : Test Your Emergency Power Generator ?

Last Answer : You should not just leave your emergency power generator in the basement all of the time without looking at it to make sure that it is working. Test it once a month to be sure that nothing has gone ... been broken for months or years. Testing it will allow you to know that it is ready and reliable.

Description : What is the best choice of emergency power generator?

Last Answer : A less-expensive and fairly reliable power generator is made by Home Standby. These models have a good reputation and are meant specifically for home use. You could also talk to your local hardware or building supply store to see what models they recommend, however.

Description : According to Coast Guard Regulation (46 CFR) for emergency power and lighting systems, which of the listed items is the only permissible starting aid for the emergency diesel generator engine? A. Ether B. Lube oil heater C. Jacket water heater D. Fuel oil heater

Last Answer : Answer: C

Description : An emergency generator, driven by an internal combustion engine, shall be tested under load for a minimum of 2 hours at least once every _____________. A. week B. 2 weeks C. month D. 3 months

Last Answer : Answer: C

Description : Coast Guard Regulations (46 CFR) require that the emergency diesel generator engine shut down when _____________. A. lubricating oil pressure is lost B. the engine overspeeds dangerously C. fixed CO2 is released into the emergency diesel generator space D. all of the above

Last Answer : Answer: D

Description : The shipboard general alarm system must receive its main source of power from _____________. A. a storage battery B. the emergency generator C. an auxiliary generator D. the ship's service generator

Last Answer : Answer: A

Description : The source of emergency lighting and power at loss of normal ship's power on a cargo vessel should be obtained from the ______________. A. emergency generator supply to the emergency ... switchboard C. battery supply to the main switchboard D. turbogenerator supply to the emergency switchboard

Last Answer : Answer: A

Description : Upon failure of the normal power supply, the emergency generator is placed on the line by the _____________. A. bus tie feeder B. automatic bus transfer device C. line connection feeder D. power failure alarm bus

Last Answer : Answer: B

Description : A diesel driven emergency generator is prevented from being paralleled with the ship's service generators by __________. A. an electrical interlock system B. an automatic paralleling trip switch C. the synchronizing oscilloscope D. the reverse current relay

Last Answer : Answer: A

Description : Under normal conditions, storage batteries used for starting the emergency diesel generator are maintained in a charged state by which of the following methods? A. Trickle charging B. Fast charging C. Equalizing charge D. Reverse charging

Last Answer : Answer: A

Description : Which of the listed sections of an emergency switchboard is used to supply power for alarm signals under emergency conditions? A. The generator and bus transfer section B. The 450 volt, 60 cycle, 3 phase bus C. The 120 volt, 3 phase, 60 cycle bus D. The 24 volt DC bus

Last Answer : Answer: D