In a single phase induction energy meter, in order to obtain true value of energy, the shunt magnetic flux should lag behind the applied voltage by 

 (a) 90o (b) 0o (c) 45o (d) 60o

1 Answer

Answer :

In a single phase induction energy meter, in order to obtain true value of energy, the shunt magnetic flux should lag behind the applied voltage by 90o

Related questions

Description : The disc of a single phase Induction-type energy meter makes 60 revolutions in 6 minutes. Meter Constant is 1200 rev/kWh. Power consumption in the load is (A) 1.2 kW (B) 1 kW (C) 600 W (D) 500 W

Last Answer : The disc of a single phase Induction-type energy meter makes 60 revolutions in 6 minutes. Meter Constant is 1200 rev/kWh. Power consumption in the load is 500 W

Description :  In a household single phase induction type wattmeter, the meter can be reversed by: - a) reversing the supply terminals b) reversing the load terminal c) opening the meter connection ... opening the meter and reversing the connection of both the potential coil terminals and current coil terminals

Last Answer :  In a household single phase induction type wattmeter, the meter can be reversed by: - opening the meter connection and reversing either the potential coil terminals or current coil terminals 

Description : State the function and shape of following parts used in induction type energy meter: i) Series magnet ii) Shunt magnet iii) Al disc iv) Brake magnet

Last Answer : i) Series magnet: produce flux proportional to current (load current) of circuit and interact in the aluminum disc with flux produced by voltage magnet for torque production. Its shape is like letter U.  ii) ... : brakes the motion of the aluminum disc or slows it down. Its shape is like letter C. 

Description : If a single-phase induction motor fails to start, the problem may be _____________. A. an open in the main winding B. a shorted shunt field C. a closed centrifugal switch D. low circuit frequency

Last Answer : Answer: A

Description : If a single-phase induction motor fails to start, the problem may be _____________. A. an open in the run winding B. a shorted shunt field C. a closed centrifugal switch D. low circuit frequency

Last Answer : Answer: A

Description : In the illustrated device, the part labeled '1A' _________. EL-0001 A. are start and run windings for a single phase shaded pole induction motor B. is the stator for a polyphase induction ... armature for a squirrel cage rotor motor D. are direct current shunt field windings for a universal motor

Last Answer : Answer: B

Description : The meter constant of a single-phase 230 V induction watt hour meter is 400 revolutions per kWh. The speed of the meter disc for a current of 10 A of 0.9 pf lagging will be

Last Answer : The meter constant of a single-phase 230 V induction watt hour meter is 400 revolutions per kWh. The speed of the meter disc for a current of 10 A of 0.9 pf lagging will be 13.80 rpm

Description : The rotation of a three-phase induction motor can be reversed by _____________. A. interchanging any two of the three line leads to the stator B. disconnecting one of the three line leads to the ... the shunt field coil leads D. permanently disconnecting any two of the three line leads to the stator

Last Answer : Answer: A

Description : The most suitable servomotor for low power applications is (A) a dc series motor. (B) a dc shunt motor. (C) an ac two-phase induction motor. (D) an ac series motor.

Last Answer : (B) a dc shunt motor.

Description :  Damping torque used in energy meter is : - a) Electrostatic b) Electro magnetic c) Eddy Current d) None

Last Answer : Damping torque used in energy meter is : - Eddy Current

Description : The potential coil of a single phase dynamometer wattmeter has 4840 Ohm resistance. Voltage across the load is 220 V. With the potential coil connected on the load side, the meter indicates 100 W. Approximate percentage error due to wattmeter connection is (A) 11% (B) 9% (C) 1.1% (D) 3%

Last Answer : The potential coil of a single phase dynamometer wattmeter has 4840 Ohm resistance. Voltage across the load is 220 V. With the potential coil connected on the load side, the meter indicates 100 W. Approximate percentage error due to wattmeter connection is 11%

Description : An ammeter has a full-scale deflection current of 100mA. If the same ammeter is used to measure a full-scale current of 1.0ampere, what is the value of the shunt resistor in ohms if the voltage across the meter is 9.0 volts?

Last Answer : 10 ohms

Description : Which one of the following frequency meter is suitable for measuring radio frequency?   (a) Vibrating reed frequency meter (b) Weston frequency meter (c) Electrical resonance frequency meter (d) Heterodyne frequency meter 

Last Answer : Which one of the following frequency meter is suitable for measuring radio frequency?   (a) Vibrating reed frequency meter (b) Weston frequency meter (c) Electrical resonance frequency meter (d) Heterodyne frequency meter 

Description :  A 0 -10 mAPMMC ammeter reads 5 mA in a circuit; its bottom control spring snaps out suddenly the meter will now read:- a) 5 mA b) 10 mA c) 2.5 mA d). 0

Last Answer :  A 0 -10 mAPMMC ammeter reads 5 mA in a circuit; its bottom control spring snaps out suddenly the meter will now read:- 0

Last Answer : Induction type single phase energy meters measure electric energy in kWh.

Description : Explain the calibration of single phase electronic energy meter using direct loading.

Last Answer : Calibration of Single-phase Electronic Energy Meter by Direct Loading Method: The following figure shows the arrangement of calibration for single phase electronic energy meter. A phase shifter is connected for ... are taken for different values of current at different power factors. 

Description : Describe with block diagram; the construction of single phase electronic energy meter. 

Last Answer : Construction of Single Phase Electronic Energy Meter: 1. CT reduces current to reasonable value for current scaling network. 2. Voltage & current scaling networks reduce proportionally the ... The ADC converts the square wave frequency analog output to display the energy in Watt-hour.

Description : List the errors occuring in single phase electronic energy meter.

Last Answer : Errors in Single Phase Electronic Energy Meter: 1) Error due to wrong sensor opeartion. 2) Error due to temperature. 3) Error due to wrong CT opeartion. 4) Error due to wrong PT opeartion. 5 ... of scaling network. 6) Error due to wrong ADC opeartion. 7) Error due to wrong Display. 

Description : The current coil of a single-phase energy meter is wound on (a) One limb of the laminated core (b) Both the limbs of the laminated core with same number of turns (c) Both the limbs of the laminated core with different number of turns (d) The centre of the limb on the laminated core

Last Answer : The current coil of a single-phase energy meter is wound on Both the limbs of the laminated core with same number of turns

Description : One single-phase energy meter operating on 230 V and 5 A for 5 hours makes 1940 revolutions. Meter constant is 400 rev/kWh. The power factor of the load is

Last Answer : One single-phase energy meter operating on 230 V and 5 A for 5 hours makes 1940 revolutions. Meter constant is 400 rev/kWh. The power factor of the load is 0.8

Description : A single phase energy meter has a constant of 1200 revolution/kWh. When a load of 200 W is connected, the disc rotates at 4.2 revolutions per min. If the load is on for 10 hours, the meter records an excess of   (a) 0.1 kWh (b) 0.2 kWh (c) 1.0 kWh (d) 2.0 kWh 

Last Answer : 2

Last Answer : The series magnet of a single phase Energy meter consists of coil of thick wire of few turns.

Description : The purpose of resistor bank 'R1-R5' in the winch circuit shown in the illustration is to ______________. EL-0102 A. limit armature current in lower and 'series field' current in hoist to ... required speeds D. regulate the strength of the brake solenoid 'B1-B2' in both directions of operation

Last Answer : Answer: C

Description : A true rms reading voltmeter uses two thermocouple in order: -  a) to increase sensitivity b) that a second thermocouple cancels out the no linear effect of the first thermocouple c) to prevent drift in the dic. Amplifier d) all of the above

Last Answer : A true rms reading voltmeter uses two thermocouple in order: -  that a second thermocouple cancels out the no linear effect of the first thermocouple

Description : The torque and current curves for a three-phase induction motor with a cage rotor, are shown in the illustration. Which of the following statements is true concerning the depicted curves? EL-0056 A. As slip ... D. If the motor is loaded to the point where 40% slip has resulted, it will stall.

Last Answer : Answer: D

Description : Why Speed Control of Induction Motor is difficult compared to DC shunt motor?

Last Answer : Answer: Speed Control of DC shunt motor can be possible by providing resistance in the armature and field circuits and varying the resistors speed changes can be carried out over a wide range. ... employed. Care should be taken that in the process efficiency and power factor should be maintained.

Description : A motor which can conveniently be operated at lagging as well as leading power factors is the (A) squirrel cage induction motor. (B) wound rotor induction motor. (C) synchronous motor. (D) DC shunt motor.

Last Answer : (C) synchronous motor.

Description : The length cf air gap to be provided in ______ is primarily determined by power factor consideration. (a) d.c. series motor . (b) d.c. shunt motor (c) induction motor (d) synchronous motor

Last Answer : (c) induction motor

Description : When a resistor is used as a shunt and is connected in parallel with a meter movement coil, it will provide _____________. A. a measurement of circuit resistance B. an increased accuracy of approximately 1.5 percent C. an extended meter range D. none of the above

Last Answer : Answer: C

Description : Which of the following meters uses a shunt connected in series with the load, but parallel with the meter movement? A. voltmeter B. power factor meter C. wattmeter D. ammeter

Last Answer : Answer: D

Description : Which of the following statements represents the correct method of connecting the shunt of an ammeter prior to taking a reading? A. In series with the load and in series with the meter movement. B. In ... with the meter movement. D. In parallel with the load and in parallel with the meter movement.

Last Answer : Answer: B

Description : The shunt of a DC ammeter should be connected in __________. A. series with the load and in parallel with the meter movement B. parallel with the load and in series with the meter movement C. ... and in parallel with the meter movement D. series with the load and in series with the meter movement

Last Answer : Answer: A

Description : Which of the listed meters uses a shunt connected in series with the load, but parallel with the meter movement? A. Voltmeter B. Power factor meter C. Ammeter D. Wattmeter

Last Answer : Answer: C

Description : External shunts are sometimes used with ammeters to _______. A. increase meter sensitivity B. permit shunts with larger resistances to be utilized C. prevent damage to the meter movement from heat generated by the shunt D. enable the construction of a compact meter with a virtually unlimited range

Last Answer : Answer: C

Description : The shunt used in an ammeter should be connected in ____________. A. series with the load and in parallel with the meter movement B. parallel with the load and in series with the meter movement C. ... in parallel with the meter movement D. series with the load and in series with the meter movement

Last Answer : Answer: A

Description : A good choice of shunt resistance will place the indicating pointer near what part of the meter scale with a normal load?

Last Answer : Midscale.

Description : Calculate the shunt resistance needed to increase the FSD of an ammeter 5 times if the meter resistance is 1kohm

Last Answer : 250ohms

Description : State the use of shunt and series resistance used in extension of meter.

Last Answer : Use of shunt and series resistance: i) Use of shunt: To extend the range of Ammeter. ii) Use of series resistance: To extend the range of Voltmeter.

Description : What are the possible errors in induction (energy meter) measuring instruments?

Last Answer : a. Phase error: Field flux in induction meter does not lag 90° behind the supply voltage due to its resistance. This can be adjusted by copper shading rings, which are placed at the central limb of the ... to prevent rotation, when one of the holes comes under one of the pole of the shunt magnet.

Description : Draw a neat sketch of 1-ph induction type energy meter and write operating principle of it. 

Last Answer : Operating Principal:- The disc is placed between the two-flux due to pressure coil and flux due to current coil, which will set up torque on the disc which is proportional to power causing the ... is proportional to voltage, the second carries a current coil so its flux is proportional to current.

Description : List any four errors in induction type energy meter. Give method of compensation for each.

Last Answer : Errors in Induction Type Energy Meter with their Compensation:  1) Error due to friction: This error can be compensated by the additional shading band provided on the shunt electromagnet.  2) Phase ... error: This error can be compensated by providing a flux diverter' to the current magnet. 

Description : An induction type energy meter is found to run fast. Correction for this error can be made by  (A) Over-load compensation. (B) Voltage compensation. (C) Moving the brake magnet away from the centre of the disc. (D) Moving the brake magnet towards the centre of the disc.

Last Answer : An induction type energy meter is found to run fast. Correction for this error can be made by Moving the brake magnet away from the centre of the disc.

Description : In an induction type energy meter, the steady speed attained by the rotating disc is  1. Proportional to the deflecting torque. 2. Proportional to the resistance of the path of eddy currents. 3. ... 4. Inversely proportional to the square of brake magnet flux.  Which of the above are correct ?

Last Answer : In an induction type energy meter, the steady speed attained by the rotating disc is 1. Proportional to the deflecting torque. 2. Proportional to the resistance of the path of eddy currents. 3. Inversely proportional to ... brake magnet flux. Which of the above are correct ? 1, 2, 3 and 4 

Description : Difference between single and three phase induction motor?

Last Answer : inverse-square relation to the distance between them. The electromagnetic force is very strong, second only in strength to the strong interaction, but unlike that force it operates over all distances. In ... . Experiment has shown charge to be a conserved quantity, that is, the net charge within

Description : Difference between single induction motor and 3 phase induction motor?

Last Answer : Many of these disciplines overlap with other engineering branches, spanning a huge number of specializations including hardware engineering, power electronics, electromagnetics and waves, microwave engineering, ... (IET) (formerly the IEE). Electrical engineers work in a very wide range

Description : A single-phase induction motor starts, comes up to about 75% rated speed, slows down to a lower speed, and accelerates again. The problem is most likely in the ____________. A. starting winding B. running winding C. starting capacitor D. running centrifugal switch

Last Answer : Answer: B

Description : A single-phase induction motor will only start if you spin the rotor rapidly with the line switch closed. After starting, its speed fluctuates between very slow and half-speed. The problem ... in the ________. A. starting winding B. centrifugal mechanism C. centrifugal switch D. running winding

Last Answer : Answer: D

Description : A single-phase induction motor fails to start. The rotor is spun rapidly with the line switch closed. Having started by this method it is noted that the motor fluctuates between a very slow ... lies in the ______ A. starting winding B. centrifugal mechanism C. centrifugal switch D. running winding

Last Answer : Answer: D

Description : In the illustration, the assembly labeled 2 is a ________. EL-0001 A. wound rotor and shaft for a single phase induction motor B. conduction rotor and shaft for a polyphase induction motor C. ... cage rotor and shaft for a polyphase motor D. squirrel cage rotor for a single phase induction motor

Last Answer : Answer: C

Description : If a three-phase induction motor malfunctions and drops to a single-phase (one supply line open) ____________. A. the motor will continue to run if it is not heavily loaded B. more torque will be ... be able to be restarted D. the motor will immediately stop and can only be restarted at no load

Last Answer : Answer: A