Calculate the shunt resistance needed to increase the FSD of an ammeter 5 times if the
meter resistance is 1kohm

1 Answer

Answer :

250ohms

Related questions

Description : Calculate the series resistance needed to convert a D' Arsonval meter with FSD of 100uA and a meter resistance of 1kohm to a voltmeter with 10V FSD.

Last Answer : Rs=10V/100uA - 1kohm = 99kohm

Description : An ammeter has a full-scale deflection current of 100mA. If the same ammeter is used to measure a full-scale current of 1.0ampere, what is the value of the shunt resistor in ohms if the voltage across the meter is 9.0 volts?

Last Answer : 10 ohms

Description : Decreasing the value of the shunt resistor of an ammeter, it current measuring capability

Last Answer : increases

Description : A permanent magnet moving coil ammeter has a coil resistance of 99 ohm and Full Scale Deflection (FSD) current of 0.1mA. Shunt resistance is 1 ohm. Current through the meter at 0.5 F.S.D is:

Last Answer : A permanent magnet moving coil ammeter has a coil resistance of 99 ohm and Full Scale Deflection (FSD) current of 0.1mA. Shunt resistance is 1 ohm. Current through the meter at 0.5 F.S.D is: 0.05mA

Description : An ammeter with an internal resistance of 50 ohm(s) is used to measure a current thorugh a lod resistor Rl = 1 kohm(s). Determine the percentage error of the reading due to ammeter insertion.

Last Answer : 50/(50+1k)*100 = 4.76%

Description : To increase the measuring capability of a moving-iron ac ammeter, a __ should be used.

Last Answer : different number of turns of coils

Description : Insulation resistance is measured by which meter?

Last Answer : megger

Description : A type of meter that gives a precise reading of voltage, current or resistance where there is the generation of samples at the input and then feeds it to a digital read-out.

Last Answer : DMM

Description : A galvanometer with 20 ohms coil resistence has a full-scale deflection of 10 mA. A 0.02 ohm is placed across the meter to increase its rating capacity. What is the new full scale current for the meter?

Last Answer : False.

Description : What ammeter is mostly used in measuring high frequency currents?

Last Answer : thermocouple

Description : ___ ammeter is used to measure high-frequency currents.

Last Answer : thermocouple

Description : In a moving coil ammeter, a ___ is connected in series with the coil to compensate for temperature variations

Last Answer : swamping resistors

Description : Error in ammeter reading is due to

Last Answer : insertion

Description : Which is the best type of ammeter movement?

Last Answer : D'Arsonval

Description : Which of the ammeter below has no insertion error?

Last Answer : clamp-meter

Description : What kind of instrument is an ammeter?

Last Answer : an indicating

Description : Current range extension in moving coil instruments can be achieved by placing a ___ in shunt with the instrument.

Last Answer : low resistance resistor

Description : Which of the following meters uses a shunt connected in series with the load, but parallel with the meter movement? A. voltmeter B. power factor meter C. wattmeter D. ammeter

Last Answer : Answer: D

Description : Which of the following statements represents the correct method of connecting the shunt of an ammeter prior to taking a reading? A. In series with the load and in series with the meter movement. B. In ... with the meter movement. D. In parallel with the load and in parallel with the meter movement.

Last Answer : Answer: B

Description : The shunt of a DC ammeter should be connected in __________. A. series with the load and in parallel with the meter movement B. parallel with the load and in series with the meter movement C. ... and in parallel with the meter movement D. series with the load and in series with the meter movement

Last Answer : Answer: A

Description : Which of the listed meters uses a shunt connected in series with the load, but parallel with the meter movement? A. Voltmeter B. Power factor meter C. Ammeter D. Wattmeter

Last Answer : Answer: C

Description : The shunt used in an ammeter should be connected in ____________. A. series with the load and in parallel with the meter movement B. parallel with the load and in series with the meter movement C. ... in parallel with the meter movement D. series with the load and in series with the meter movement

Last Answer : Answer: A

Description : An electrodynamic meter used t measure power

Last Answer : wattmeter

Description : Type of power-line frequency meter composed of vibrating iron reed placed in alternating magnetic field

Last Answer : Vibrating Reed Type

Description : The only use of voltage senstive meter movement

Last Answer : very low voltage measurement

Description : When the meter is unsufficiently damped, it is considered as ___

Last Answer : underdamped

Description : It is the reciprocal of the full-scale current of a meter

Last Answer : sensitivity

Description : A meter when __ will become insensitive to small signals

Last Answer : overdamped

Description : Type of power-line frequency meter device utilizing a principle of balancing an indicator needle at center of a scale using magnetic fields opposing each other.

Last Answer : magnetic type

Description : A meter has a full-scale current of 50uA, what is its sensitivity?

Last Answer : Is=1/50uA=20kohm/V

Description : Errors due to frictions of the meter movement, incorrect spring tension, improper calibration or faulty instruments:

Last Answer : instrument errors

Description : What is that meter that depends for its operation on the forces attraction and repulsion

Last Answer : electrostatic instrument

Description : A tunable RF instrument, which, by means of a sharp dip of an indicating meter, indicates resonance with an external circuit under test

Last Answer : dip meter

Description : What is the most common type of meter movement?

Last Answer : D' Arsonval

Description : In meter movement, how do oyu prevent the meter from oscillating and overswing?

Last Answer : by damping

Description : What type of instrument is the watt-hour meter?

Last Answer : an integrating

Description : ___ meter is the most sensitive

Last Answer : 1uA

Description : What is interface level ? How do you calculate it ?  

Last Answer : When a vessel is filled with two liquids of two different specific gravities the level measurement refers to as interface level. DP = H ( D - d )   On a level set the difference of two specific gravities.   

Description : In order to increase its range of measurement, a resistance would be placed in series with which of the following instruments? A. DC voltmeter B. DC ammeter C. frequency meter D. power factor meter

Last Answer : Answer: A

Description : A PMMC instrument has FSD of 100 μA and a coil resistance of 1 kΩ. To convert the instrument into an ammeter with full scale deflection of 100 mA, the required shunt resistance is (A) 1 Ω (B) 1.001 Ω (C) 0.5 Ω (D) 10 Ω

Last Answer : A PMMC instrument has FSD of 100 μA and a coil resistance of 1 kΩ. To convert the instrument into an ammeter with full scale deflection of 100 mA, the required shunt resistance is 1.001 Ω

Description : A DC ammeter has resistance `0.1 Omega` and its current ranges `0-100 A`. If the range is to be extended to `0-500`, then the following shunt resistan

Last Answer : A DC ammeter has resistance `0.1 Omega` and its current ranges `0-100 A`. If the range is to be extended ... Omega` C. `0.025 Omega` D. `0.25 Omega`

Description : Assertion : Resistance of an ammeter is less than the resistance of a milliammeter. Reason : Value of shunt required in case of ammeter is more than a

Last Answer : Assertion : Resistance of an ammeter is less than the resistance of a milliammeter. Reason : Value of ... . If Assertion is false but Reason is true.

Description : A moving coil galvanometer is converted into an ammeter reads upto `0.03 A` by connecting a shunt of resistance `4r` across it and ammeter reads up `0

Last Answer : A moving coil galvanometer is converted into an ammeter reads upto `0.03 A` by connecting a shunt of resistance `4r` ... `0.02A` C. `0.03A` D. `0.04A`

Description : A galvanometer of 65 Ω resistance gives full scale deflection with 4 mA current. In order to convert it into ammeter, the range of 10 A is connected with it, the shunt resistance should be a) 0.1 Ω b) 0.2 Ω c) 0.06 Ω d) 0.03 Ω

Last Answer : d) 0.03 Ω

Description : Sketch the circuit of basic DC ammeter , derive equation for shunt resistance.

Last Answer : Derivation The basic movement of dc ammeter circuit consists of D' Arsonval galvanometer. When large current is to be measured then some extra modification is required. For measurement of large current by using ... same. Vsh =Vm m IshRsh=ImRm Rsh=ImRm/Ish Rsh=ImRm/(I-Im) 

Description : A 10A DC Ammeter has a resistance of 0.1 Ω is to be extended to 50 A, the required shunt wire is A) Manganin wire of 20 m Ω B) Constantan wire of 20 m Ω C) Manganin wire of 25 m Ω D) Constantan wire of 25 m Ω

Last Answer : A 10A DC Ammeter has a resistance of 0.1 Ω is to be extended to 50 A, the required shunt wire is Manganin wire of 25 m Ω

Description : Which of the following bridges measures dc resistance?

Last Answer : Wheatstone bridge

Description : A dc bridge widely used for the accurate measurements of resistance

Last Answer : Wheatstone bridge

Description : What sensor provides a change of resistance with typical power range of 1uW to 10mW and with maximum frequency greater than 100GHz

Last Answer : thermistor sensor

Description : A small swamping resistance is connected in series with operating coil of a moving coil ammter in order to compensate for the effects of ____

Last Answer : temperature variation