List the errors occuring in single phase electronic energy meter.

1 Answer

Answer :

Errors in Single Phase Electronic Energy Meter:

1) Error due to wrong sensor opeartion.

2) Error due to temperature.

3) Error due to wrong CT opeartion.

4) Error due to wrong PT opeartion.

5) Error due to wrong opeartion of scaling network.

6) Error due to wrong ADC opeartion.

7) Error due to wrong Display. 

Related questions

Description : Explain the calibration of single phase electronic energy meter using direct loading.

Last Answer : Calibration of Single-phase Electronic Energy Meter by Direct Loading Method: The following figure shows the arrangement of calibration for single phase electronic energy meter. A phase shifter is connected for ... are taken for different values of current at different power factors. 

Description : Describe with block diagram; the construction of single phase electronic energy meter. 

Last Answer : Construction of Single Phase Electronic Energy Meter: 1. CT reduces current to reasonable value for current scaling network. 2. Voltage & current scaling networks reduce proportionally the ... The ADC converts the square wave frequency analog output to display the energy in Watt-hour.

Description :  Draw a neat labeled block diagram of 3-phase Electronic Energy meter.

Last Answer : Labeled diagram of 3-phase electronic energy meter:

Description : State the advantages of electronic energy meter. 

Last Answer : Advantages of Electronic Energy Meter: 1) Low cost. 2) High accuracy. 3) More flexibility. 4) High sensitivity 5) No frictional losses. 6) Less loading effect. 7) High frequency ... for external adjustment. 11) Low load, full load, power factor and creeping adjustments are not required.

Description : List the types of systematic errors and state the reasons due to which these errors occur.

Last Answer : Systematic Error: i) Instrumental Error: These errors are caused due to the mechanical structure of measuring instrument such as: a) Inherent shortcomings of instruments: Instrument may ... or electrostatic fields. iii) Observational Error: Parallax errors, incorrect multiplying factor.

Description : Describe different types of errors in analog measuring instruments. 

Last Answer : Types of Errors in Analog Measuring Instruments: A) Gross error: These are due to mistakes on the part of person using the instrument. B) Systematic Error: It has three sub types as ... multiplying factor. C) Random error: These persist even after gross and systematic errors are removed.

Description : State the meaning of energy meter constant K. State its unit.

Last Answer : Meaning of Energy Meter Constant (K): Energy Meter Constant is the no. of revolutions made by disc in meter per unit (kWh) consumption of energy. Unit of energy meter constant K is rev/kWH

Description : A single phase wattmeter rated for 500 V; 5A is having full scale deflection of 1000 watt. What is multiplying factor of the wattmeter?

Last Answer : Answer :

Description : List any four errors in induction type energy meter. Give method of compensation for each.

Last Answer : Errors in Induction Type Energy Meter with their Compensation:  1) Error due to friction: This error can be compensated by the additional shading band provided on the shunt electromagnet.  2) Phase ... error: This error can be compensated by providing a flux diverter' to the current magnet. 

Description : Draw the block diagram of tri-vector meter. State the various measurements possible from tri-vector meter.

Last Answer : Various measurements possible from tri-vector meter are: Tri-vector meter is a measuring instrument which measures the kWh, kVArh, the kVAh of a power line. Tri-vector meter is an energy meter ... of supply such as voltage, current, power factor, active load, reactive load, apparent load etc.

Description : Describe with block diagram the working of digital frequency meter.

Last Answer : Digital frequency meter: Amplifier: The signal whose frequency is to be measured is first amplified and supplied to the schmitt trigger. Schmitt Trigger: The schmitt trigger convert ... count displayed on counter  t = time interval between start and stop condition of the gate 

Description : State the purpose of four quadrant meter.

Last Answer : Purpose of four quadrant meter:  Four-quadrant meter is basically a bidirectional energy-meter with additional measurement facility. The purposes of four-quadrant meter are: 1) Measurement of energy/power ... and kVARh 3) Time-of-use metering: Bidirectional consumption and demand.

Description : Draw the circuit diagram for:- i) Measurement of active power in 3-phase load circuit using two wattmeter. ii) Measurement of reactive power in 3-phase load circuit using one wattmeter.

Last Answer : (i) Measurement of active power in 3- phase load circuit using two- wattmeter: (ii) Measurement of reactive power in 3- phase load circuit using one wattmeter

Description : What are the possible errors in induction (energy meter) measuring instruments?

Last Answer : a. Phase error: Field flux in induction meter does not lag 90° behind the supply voltage due to its resistance. This can be adjusted by copper shading rings, which are placed at the central limb of the ... to prevent rotation, when one of the holes comes under one of the pole of the shunt magnet.

Description : Annual total energy & production chart smoothens out ____ in energy timing of meter readings. a) Errors b) Efficiency c) Accuracy. d) Repeatability

Last Answer : errors

Description : In a single phase induction energy meter, in order to obtain true value of energy, the shunt magnetic flux should lag behind the applied voltage by   (a) 90o (b) 0o (c) 45o (d) 60o

Last Answer : In a single phase induction energy meter, in order to obtain true value of energy, the shunt magnetic flux should lag behind the applied voltage by 90o

Description : The disc of a single phase Induction-type energy meter makes 60 revolutions in 6 minutes. Meter Constant is 1200 rev/kWh. Power consumption in the load is (A) 1.2 kW (B) 1 kW (C) 600 W (D) 500 W

Last Answer : The disc of a single phase Induction-type energy meter makes 60 revolutions in 6 minutes. Meter Constant is 1200 rev/kWh. Power consumption in the load is 500 W

Description : The current coil of a single-phase energy meter is wound on (a) One limb of the laminated core (b) Both the limbs of the laminated core with same number of turns (c) Both the limbs of the laminated core with different number of turns (d) The centre of the limb on the laminated core

Last Answer : The current coil of a single-phase energy meter is wound on Both the limbs of the laminated core with same number of turns

Description : One single-phase energy meter operating on 230 V and 5 A for 5 hours makes 1940 revolutions. Meter constant is 400 rev/kWh. The power factor of the load is

Last Answer : One single-phase energy meter operating on 230 V and 5 A for 5 hours makes 1940 revolutions. Meter constant is 400 rev/kWh. The power factor of the load is 0.8

Description : A single phase energy meter has a constant of 1200 revolution/kWh. When a load of 200 W is connected, the disc rotates at 4.2 revolutions per min. If the load is on for 10 hours, the meter records an excess of   (a) 0.1 kWh (b) 0.2 kWh (c) 1.0 kWh (d) 2.0 kWh 

Last Answer : 2

Last Answer : The series magnet of a single phase Energy meter consists of coil of thick wire of few turns.

Description : Define electrical energy. State its unit.

Last Answer : Electrical Energy: Electrical energy is defined as the work done in moving electrical charge in electrical field. OR The total power delivered or consumed by electrical load over specific unit time ... unit of electrical energy is the joule (or watt-second) OR Kilowatt-hour ( kWH ).

Description : Errors due to frictions of the meter movement, incorrect spring tension, improper calibration or faulty instruments:

Last Answer : instrument errors

Description : Draw a block diagram of electronic energy meter. Write function of each block.

Last Answer : Electronic Energymeter  Functions of components/blocks: - CT reduces current to reasonable value for current scaling network. - Voltage & current scaling networks reduce proportionally the voltage ... ADC converts the square wave frequency analog output to display the energy in watthour.

Description : Draw and describe working of electronic energy meter.

Last Answer : working of electronic energy meter:- 1. CT reduces current to reasonable value for current scaling network. 2. Voltage & current scaling networks reduce proportionally the voltage & ... The ADC converts the square wave frequency analog output to display the energy in watthour. 

Description : What is the power factor when a single phase watt meter operating on 200 V and 5 A for 5 hours makes 2016 revolutions and the meter constant in revolution is 420? A) 0.04 B) 1.04 C) 0.96 D) None of these

Last Answer : What is the power factor when a single phase watt meter operating on 200 V and 5 A for 5 hours makes 2016 revolutions and the meter constant in revolution is 420? A) 0.04 B) 1.04 C) 0.96 D) None of these

Description : The meter constant of a single-phase 230 V induction watt hour meter is 400 revolutions per kWh. The speed of the meter disc for a current of 10 A of 0.9 pf lagging will be

Last Answer : The meter constant of a single-phase 230 V induction watt hour meter is 400 revolutions per kWh. The speed of the meter disc for a current of 10 A of 0.9 pf lagging will be 13.80 rpm

Description :  In a household single phase induction type wattmeter, the meter can be reversed by: - a) reversing the supply terminals b) reversing the load terminal c) opening the meter connection ... opening the meter and reversing the connection of both the potential coil terminals and current coil terminals

Last Answer :  In a household single phase induction type wattmeter, the meter can be reversed by: - opening the meter connection and reversing either the potential coil terminals or current coil terminals 

Last Answer : In a single phase power factor meter the phase difference between the currents in the two pressure coils is exactly 90°.

Last Answer : The two pressure coils of a single phase power factor meter have the same dimensions and the same number of turns.

Description : Do you think that speciation is occuring within domesticated dogs?

Last Answer : Dog breeds all readily reproduce. (Except perhaps bulldogs, who can’t even reproduce within the breed without human intervention.)

Description : How is diffusion occuring?

Last Answer : answer:Let’s start with what you observe when you actually do the experiment. Tell us what you see happening. Then we can talk about diffusion, OK?

Description : Why are they not using bioremediation on the Gulf oil spill ? Evidently these are naturally occuring microbes, available in powdered form, which feed on the oil and digest it into harmless compounds.

Last Answer : answer:I'm not a scientist, but the site you linked does say The microbes are simply mixed with water and sprayed on the oil as it reaches the calmer waters near shore or on shore itself. That could be ... before all the oil gets to the shore and it can get to the water that's under the surface.

Description : Is bullying taught or it is naturally occuring in kids?

Last Answer : I have worked in the child care field, and I believe there are some children between 2 and 5 who are naturally aggressive and mean. If raised properly, they can lose these traits by the age of 6 or 7.Children can also be taught to be mean.

Description : Chlorophyll is a naturally occuring chelate compound in, what is the which the central metal in this? -General Knowledge

Last Answer : answer:

Description : Chlorophyll is a naturally occuring chelate compound in, what is the which the central metal in this? -General Knowledge

Last Answer : answer:

Description : Assertion: Assimilotary power in photosynthesis is generated in ETS occuring in thylakoid membrane . Reason : They are needed for `CO_(2)` reduction.

Last Answer : Assertion: Assimilotary power in photosynthesis is generated in ETS occuring in thylakoid membrane . ... If both Assertion and Reason are false.

Description : Tartaric acid `[HO_(2)CCH(OH)CH(OH)CO_(2)H]` was an important compound in history of stereochemistry. Two naturally occuring forms of tartaric acid ar

Last Answer : Tartaric acid `[HO_(2)CCH(OH)CH(OH)CO_(2)H]` was an important compound in history ... . D. Optically inactive due to intramoleuclar hydrogen bonding.

Description : Tartaric acid `[HO_(2)CCH(OH)CH(OH)CO_(2)H]` was an important compound in history of stereochemistry. Two naturally occuring forms of tartaric acid ar

Last Answer : Tartaric acid `[HO_(2)CCH(OH)CH(OH)CO_(2)H]` was an important compound in history of stereochemistry. Two ... form Q is A. B. C. D. none of these

Description : Tartaric acid `[HO_(2)CCH(OH)CH(OH)CO_(2)H]` was an important compound in history of stereochemistry. Two naturally occuring forms of tartaric acid ar

Last Answer : Tartaric acid `[HO_(2)CCH(OH)CH(OH)CO_(2)H]` was an important compound in history ... . D. Optically inactive due to intramoleuclar hydrogen bonding.

Description : Tartaric acid `[HO_(2)CCH(OH)CH(OH)CO_(2)H]` was an important compound in history of stereochemistry. Two naturally occuring forms of tartaric acid ar

Last Answer : Tartaric acid `[HO_(2)CCH(OH)CH(OH)CO_(2)H]` was an important compound in history of stereochemistry. Two ... form Q is A. B. C. D. none of these

Description : Which one of the following is the correct matching of the events occuring during menstrual cycle?

Last Answer : Which one of the following is the correct matching of the events occuring during menstrual cycle? ... and increased secretion of progesterone."):}`

Description : The radiation from naturally occuring radioactive substance as seen after deflection by a magnetic field in one direction are :

Last Answer : The radiation from naturally occuring radioactive substance as seen after deflection by a magnetic field in one ... D. either `alpha` or `beta`-rays

Description : The main reactions occuring in blast furnace during extraction of iron from haematite ore…..

Last Answer : The main reactions occuring in blast furnace during extraction of iron from haematite ore .. A. `Fe_(2)O_ ... 3Cto2Fe+3CO` D. `CaO+SiO_(2)toCaSiO_(2)`

Description : Chlorophyll is a naturally occuring chelate compound, what is the central metal in this?

Last Answer : Magnesium

Description : The metals occuring at the lower most position in the electromotive series (A) Do not resist corrosion (B) Resist corrosion very strongly (C) Are very brittle (D) Are heat insulators

Last Answer : (B) Resist corrosion very strongly

Description : Which of the following reactions occuring during coal gasification is called the Neumann reversal reaction? (A) 2CO ↔ C + CO2 (B) CO + H2O ↔ CO2 + H2 (C) C + H2O ↔ CO + H2 (D) C + 2H2O ↔ CO2 + 2H2

Last Answer : (A) 2CO ↔ C + CO2

Description : The phenomenon occuring during pumping of a liquid solution containing dissolved gases, which may come out of the solution giving rise to gas pockets, is termed as (A) Evaporation (B) Cavitation (C) Sublimation (D) Stripping

Last Answer : (B) Cavitation

Description : Zeolite is a/an (A) Naturally occuring clay which is capable of exchanging cations (B) Abrasive material (C) Catalyst used in shift conversion (D) None of these

Last Answer : (A) Naturally occuring clay which is capable of exchanging cations

Description : The equation DU = Tds - PdV is applicable to infinitesimal changes occuring in (A) An open system of constant composition (B) A closed system of constant composition (C) An open system with changes in composition (D) A closed system with changes in composition

Last Answer : (D) A closed system with changes in composition