Which one of the following frequency meter is suitable for measuring radio frequency? 

 (a) Vibrating reed frequency meter (b) Weston frequency meter (c) Electrical resonance frequency meter (d) Heterodyne frequency meter 

1 Answer

Answer :

Which one of the following frequency meter is suitable for measuring radio frequency? 

 (a) Vibrating reed frequency meter (b) Weston frequency meter (c) Electrical resonance frequency meter (d) Heterodyne frequency meter 

Related questions

Last Answer : To measure radio frequency, the suitable frequency meter is heterodoxy frequency meter.

Description : A useful instrument for checking A.C. motor performance by measuring possible unbalanced currents is the _____________. A. hand or battery-operated megger B. vibrating-reed frequency meter C. hook-on voltmeter-ammeter D. D'Arsonval iron-vane probe

Last Answer : Answer: C

Description : When measuring strain, ballast circuit use a capacitor to act as a high pass filter. This is done when:  a) Static strain are being measured b) Dynamic strain are being measured c) Both Static and dynamic strain are being measured d) None of the above

Last Answer : When measuring strain, ballast circuit use a capacitor to act as a high pass filter. This is done when: Dynamic strain are being measured

Description : When measuring a transmitter’s frequency against a suitable standard, the frequency to be measured is taken from the A. oscillator stage B. intermediate amplifier C. buffer stage D. final RF stage

Last Answer : D. final RF stage

Description : In a single phase induction energy meter, in order to obtain true value of energy, the shunt magnetic flux should lag behind the applied voltage by   (a) 90o (b) 0o (c) 45o (d) 60o

Last Answer : In a single phase induction energy meter, in order to obtain true value of energy, the shunt magnetic flux should lag behind the applied voltage by 90o

Description : The disc of a single phase Induction-type energy meter makes 60 revolutions in 6 minutes. Meter Constant is 1200 rev/kWh. Power consumption in the load is (A) 1.2 kW (B) 1 kW (C) 600 W (D) 500 W

Last Answer : The disc of a single phase Induction-type energy meter makes 60 revolutions in 6 minutes. Meter Constant is 1200 rev/kWh. Power consumption in the load is 500 W

Description :  Damping torque used in energy meter is : - a) Electrostatic b) Electro magnetic c) Eddy Current d) None

Last Answer : Damping torque used in energy meter is : - Eddy Current

Description :  A 0 -10 mAPMMC ammeter reads 5 mA in a circuit; its bottom control spring snaps out suddenly the meter will now read:- a) 5 mA b) 10 mA c) 2.5 mA d). 0

Last Answer :  A 0 -10 mAPMMC ammeter reads 5 mA in a circuit; its bottom control spring snaps out suddenly the meter will now read:- 0

Description :  In a household single phase induction type wattmeter, the meter can be reversed by: - a) reversing the supply terminals b) reversing the load terminal c) opening the meter connection ... opening the meter and reversing the connection of both the potential coil terminals and current coil terminals

Last Answer :  In a household single phase induction type wattmeter, the meter can be reversed by: - opening the meter connection and reversing either the potential coil terminals or current coil terminals 

Description : For measurement of radio frequency ac signals __________ type meter is used

Last Answer : For measurement of radio frequency ac signals thermo-couple type meter is used

Description : Radio frequency ranges from 30MHz to 1GHz and it is suitable for:  a. Point to point transmission b. Omni directional transmission c. Local point to point transmission d. None of the above

Last Answer : Radio frequency ranges from 30MHz to 1GHz and it is suitable for: Local point to point transmission

Description : Thermocouple instruments can be used for a frequency range upto   (a) 100Hz (b) 5000 Hz (c) 1 MHz (d) 50 MHz and above 

Last Answer : Thermocouple instruments can be used for a frequency range upto 50 MHz and above 

Description : The input frequency is 50 Hz. The ripple frequency in a 12 phase full wave rectifier is (A) 1200 Hz (B) 600 Hz (C) 100 Hz (D) 50 Hz 

Last Answer : The input frequency is 50 Hz. The ripple frequency in a 12 phase full wave rectifier is 1200 Hz

Description : The Q factor of a coil at resonant frequency 1.5 MHz of an RLC series circuit is 150. The Bandwidth is : - a) 225 MHz b) 1.06 MHz c) 10 KHz d) 10 MHz

Last Answer : The Q factor of a coil at resonant frequency 1.5 MHz of an RLC series circuit is 150. The Bandwidth is : - 10 KHz

Description : The modulation index of a FM Signal having modulating frequency 2 KHz and Max deviation is 10 KHz, is: -  a) 2 b) 5 c) 3 d) 4

Last Answer : The modulation index of a FM Signal having modulating frequency 2 KHz and Max deviation is 10 KHz, is: - 5

Description :  The effective resistance of a coil at high frequency is more than its de resistance on account of : -  a) Skin effect b) Proximity effects c) Eddy current losses d) All the above

Last Answer :  The effective resistance of a coil at high frequency is more than its de resistance on account of : - All the above

Description : When measuring AC current flow, you must always connect the meter _____________. A. in series with the power source and load B. in parallel with the power source and load C. insuring correct polarity D. using the lowest range possible to prevent instrument damage

Last Answer : Answer: A

Description : Before measuring an unknown resistance with an ohmmeter, you should _____________. A. adjust the meter's pointers to mid-scale B. change the meter's batteries C. center the meter's pointer at infinity D. short the test leads and calibrate the meter

Last Answer : Answer: D

Description : Before measuring an unknown resistance with an ohmmeter, you should _____________. A. adjust the meter's pointer to mid-scale B. short the test leads and calibrate the meter reading to 'zero' C. change the meter's batteries D. center the meter's pointer at infinity

Last Answer : Answer: B

Description : You are measuring noise at a -6 dB level point, using the Lenkurt 601A, F1A weighting network, and a flat meter. The meter reading is -59 dBm. This is _________ dBa0. A. 24 B. 12 C. 23 D. 32

Last Answer : D. 32

Description : You are measuring noise at a +3 dB level point, using the Lenkurt 601A, F1A weighting network, and a flat meter. The meter reading is -57dBm. This is ________dBa0. A. 20 B. 15 C. 25 D. 17

Last Answer : C. 25

Description : You are measuring noise in a voice channel with a Lenkurt 601A, F1A weighting network and a flat meter. Your meter reads -47dBm. What is this reading in dBa? A. 77 dBa B. 35 dBa C. 38 dBa D. 32 dBa

Last Answer : C. 38 dBa

Description : What device measures rf power by measuring the heat the rf power generates? A. Calorimeter B. Goniometer C. Spectrum meter D. Oscilloscope

Last Answer : A. Calorimeter

Description : You are measuring noise in a voice channel at 7 dB test point level. The meter reads -56 dBm (FIA weighted). What is the reading in dBrnc? A. 20 B. 32 C. 35 D. 25

Last Answer : C. 35

Description : You are measuring a voice channel at a -4 dB test point level, the meter reads -73 dBm (pure test tone) convert the reading in dBmCO. A. 16 B. 18 C. 22 D. 12

Last Answer : C. 22

Description : In measuring noise in a voice channel at a 4 dB test point level, the meter reads -70 dBm (F1A weighted), convert the reading to pWp. A. 53 B. 93 C. 63 D. 83

Last Answer : B. 93

Description : Most appropriate instrument for measurement of internal and external diameter of a tube is A. vernier callipers B. micrometer screw gauge C. meter rule D. measuring tape

Last Answer : vernier callipers

Description : What are the possible errors in induction (energy meter) measuring instruments?

Last Answer : a. Phase error: Field flux in induction meter does not lag 90° behind the supply voltage due to its resistance. This can be adjusted by copper shading rings, which are placed at the central limb of the ... to prevent rotation, when one of the holes comes under one of the pole of the shunt magnet.

Description : Which instrument is used for measuring the magnitude of an earthquake- a) Tilit meter b) Richter scale c) Seismograph d) Seismometer

Last Answer : b) Richter scale

Description : Which of the following flow measuring devices is an area meter? (A) Venturimeter (B) Orificemeter (C) Anemometer (D) Rotameter

Last Answer : (D) Rotameter

Description : The best instrument for measuring the velocity of a stream flow is (A) Pitot tube (B) Price's current meter (C) Surface float (D) Sub-surface float

Last Answer : Answer: Option B

Description : What value does a meter movement react to (actually measure) when measuring ac?

Last Answer : Average value.

Description : A multipurpose instrument for measuring current, potential difference and resistance is a) Ohmmeter b) Astatic galvanometer c) Rheostat d) AVO Meter

Last Answer : d) AVO Meter

Description : nstrument used for measuring the depth & width of ploughing : A. penetrometer B. width meter C. depth meter D. width and depth meter

Last Answer : A. penetrometer

Description : what is the value of long chord for measuring unevenness in track recording a. 3.6 meter b. 9.6 meter* c. 7.2 meter d. 4.8 mete

Last Answer : b. 9.6 meter*

Description : List out any four effects of electric current used in measuring instruments & write name of meter working on it.

Last Answer : Effects of Electric Current used in measuring instruments:  1. Magnetic Effect: PMMC and Moving Iron type Ammeters, voltmeter and Dynamometer type wattmeters etc.  2. Electromagnetic induction ... . Electrostatic effect: Voltmeters.  5. Hall Effect: Flux meter, Poynting vector wattmeter.

Description : Why energy meter is integrating type measuring instrument?

Last Answer : Energy Meter is Integrating Type Measuring Instrument: Energy meter is used for measurement of energy, which is obtained by integration (summation) of power supplied over the particular time duration, hence it the integrating type measuring instrument. 

Last Answer : For measuring an unknown electrical quantity, select the meter with Highest range and work down.

Description : ____________ is measuring the propagated field strength over the projected service area A. Radio sounding B. None of these C. Radio monitoring D. Radio survey

Last Answer : D. Radio survey

Description : Which of the following statements regarding the use of a current measuring instrument is correct? A. It must be connected in series with the circuit. B. You should always start with the lowest range ... of polarity. D. An external shunt is generally utilized where current is less than 10 amperes.

Last Answer : Answer: A

Description : Thermocouple is suitable for measuring (A) Liquid temperatures only (B) Very high temperatures only (C) Very low temperatures only (D) Both high and low temperatures

Last Answer : (D) Both high and low temperatures

Description : The most suitable flow measuring device for the fluid flow measurement in a very large diameter pipeline is a (A) Weir (B) Pitot tube (C) Kennison nozzle (D) V-notch

Last Answer : (B) Pitot tube

Description : The most serious disadvantage of an orificemeter is that (A) It is not very accurate (B) It is very costly (C) Most of the pressure drop is not recoverable (D) It is not suitable for measuring gas flow

Last Answer : (C) Most of the pressure drop is not recoverable

Description : Which of the following methods of theodolite traversing is suitable for locating the details which are far away from transit stations? (A) Measuring angle and distance from one transit station (B) ... at one station and distance from other (D) Measuring distance from two points on traverse line

Last Answer : (B) Measuring angles to the point from at least two stations

Description : Electrostatic voltmeters are particularly suitable for measuring high voltages because the construction is simplified due to

Last Answer : Electrostatic voltmeters are particularly suitable for measuring high voltages because the construction is simplified due to Large electrostatic forces.

Description : A radio station is broadcasting at 3750 khz (kilohertz). This station would be found in which radio band? w) 20 meter x) 40 meter y) 80 meter z) 160 meter 

Last Answer : ANSWER: Y -- 80 METER 

Description : The hp available at the crank shaft which is measured by a suitable dynamo meter is called 1. IMEP 2. BHP 3. Both 1 and 2 4. none of these

Last Answer : <!-- [if !supportLists] -->1.   <!-- [endif] -->ans 2  

Description : Write the working of L-C-R meter with suitable sketch.

Last Answer : LCR meter: A LCR meter (Inductance L, Capacitance C, and Resistance R) test equipment used to measure the inductance, capacitance and, resistance of a component. It works on the principle ... relative change in magnitude of the repetitive variations of the voltage and current known as amplitudes.

Description : Ondometer is a - (1) Measuring instrument for distance covered by motor wheels (2) Measuring instrument for frequency of electromagnetic waves (3) Device for measuring sound intensity (4) Measuring instrument for electric power

Last Answer : (2) Measuring instrument for frequency of electromagnetic waves