It is the reciprocal of the full-scale current of a meter

1 Answer

Answer :

sensitivity

Related questions

Description : A meter has a full-scale current of 50uA, what is its sensitivity?

Last Answer : Is=1/50uA=20kohm/V

Description : A galvanometer with 20 ohms coil resistence has a full-scale deflection of 10 mA. A 0.02 ohm is placed across the meter to increase its rating capacity. What is the new full scale current for the meter?

Last Answer : False.

Description : An ammeter has a full-scale deflection current of 100mA. If the same ammeter is used to measure a full-scale current of 1.0ampere, what is the value of the shunt resistor in ohms if the voltage across the meter is 9.0 volts?

Last Answer : 10 ohms

Description : Type of power-line frequency meter device utilizing a principle of balancing an indicator needle at center of a scale using magnetic fields opposing each other.

Last Answer : magnetic type

Description : What is the typical full-scale deflection current of a moving coil instrument?

Last Answer : 50mA

Description : A type of meter that gives a precise reading of voltage, current or resistance where there is the generation of samples at the input and then feeds it to a digital read-out.

Last Answer : DMM

Description : What is the typical full-scale voltage across a moving coil voltmeter?

Last Answer : 50mV

Description : An electrodynamic meter used t measure power

Last Answer : wattmeter

Description : Type of power-line frequency meter composed of vibrating iron reed placed in alternating magnetic field

Last Answer : Vibrating Reed Type

Description : The only use of voltage senstive meter movement

Last Answer : very low voltage measurement

Description : When the meter is unsufficiently damped, it is considered as ___

Last Answer : underdamped

Description : Calculate the series resistance needed to convert a D' Arsonval meter with FSD of 100uA and a meter resistance of 1kohm to a voltmeter with 10V FSD.

Last Answer : Rs=10V/100uA - 1kohm = 99kohm

Description : A meter when __ will become insensitive to small signals

Last Answer : overdamped

Description : Insulation resistance is measured by which meter?

Last Answer : megger

Description : Errors due to frictions of the meter movement, incorrect spring tension, improper calibration or faulty instruments:

Last Answer : instrument errors

Description : What is that meter that depends for its operation on the forces attraction and repulsion

Last Answer : electrostatic instrument

Description : A tunable RF instrument, which, by means of a sharp dip of an indicating meter, indicates resonance with an external circuit under test

Last Answer : dip meter

Description : What is the most common type of meter movement?

Last Answer : D' Arsonval

Description : In meter movement, how do oyu prevent the meter from oscillating and overswing?

Last Answer : by damping

Description : What type of instrument is the watt-hour meter?

Last Answer : an integrating

Description : Calculate the shunt resistance needed to increase the FSD of an ammeter 5 times if the meter resistance is 1kohm

Last Answer : 250ohms

Description : ___ meter is the most sensitive

Last Answer : 1uA

Description : For amplitude measurements, ___ scale is calibrated in either volts per centimeter (V/cm), or millivolts per centimeter (mV/cm)

Last Answer : vertical

Description : The scale of a hot-wire instrument is a/an ___function

Last Answer : squared

Description : Moving-iron instrument has a/an scale

Last Answer : squared

Description : Most AC voltmeters have an rms scale which is valid only if the input signal being measured is a __ signal.

Last Answer : sinusoidal

Description : For time measurements, ___ scale of the scope is used.

Last Answer : horizontal

Description : What is the reason why the scale of a permanent-magnet moving coil instrument is uniform?

Last Answer : because it is spring controlled

Description : Indicating instrument is assumed to be most accurate at what part of the scale?

Last Answer : at half or full

Description : On a simple ohmmeter, the 0 ohm(s0 mark is located __ of the scale

Last Answer : at far right

Description : How much current does an electrostatic voltmeter require through it to operate?

Last Answer : zero current

Description : What is the device, which depends on the action of a movalbe permanent magnet, in aligning itself in the resultant field produced by a fixed permanent magnet or current- carrying coils whose axes are displaced by a fixed angle?

Last Answer : moving-magnet instrument

Description : Current range extension in moving coil instruments can be achieved by placing a ___ in shunt with the instrument.

Last Answer : low resistance resistor

Description : In an oscilloscope, ___ adjusts the brightness of the spot by chaning the current on the control grid.

Last Answer : intensity control

Description : Decreasing the value of the shunt resistor of an ammeter, it current measuring capability

Last Answer : increases

Description : An instrument used to detect and measure the presence of electrical current is generally called

Last Answer : galvanometer

Description : All voltmeters except one of the following are operated by the passage of current

Last Answer : electrostatic

Description : For a dynamometer to be able to measure high current, a ___ should be used.

Last Answer : current transformer

Description : What is the basic unit for measuring current flow?

Last Answer : ampere

Description : An instrument used for measuring the amount of current flowing in a circuit.

Last Answer : ammeter

Description : An ammeter with an internal resistance of 50 ohm(s) is used to measure a current thorugh a lod resistor Rl = 1 kohm(s). Determine the percentage error of the reading due to ammeter insertion.

Last Answer : 50/(50+1k)*100 = 4.76%

Description : What is a filter used for ?

Last Answer : The half wave and full wave signals are pulsating D . C . voltages. The use of such voltages is limited to charging batteries, running D. C. motors, and a few other applications. What we really ... voltage from a battery. To get a constant voltage from this, we can use a capacitor input filter. 

Description : What is Zener Diode ? What is a voltage Regulator ?

Last Answer : The breakdown region of a p n diode can be made very sharp and almost vertical Diodes with almost vertical breakdown region are known as Zever Diodes. A Zener diodes operating in the breakdown ... VOLTAGE REGULATOR : The output remains constant despite changes in input voltage due to Zever effect.  

Description : What is transistor ? What are the different types ?

Last Answer : A transistor is a three lagged semi conductor device. Basically a transistor means (transfer - resister). Whether the transistor is pnp or npn it resembles two diodes (back to back). The one of the left ... transistor : Emitter - Base - Forward Bias. Collector - Base - Reverse Bias. 

Description : What is CB, CE and CC configuration ?

Last Answer : Buffer : A device or a circuit used to isolate two pt'ne circuits or stages. The emitter follows is a example of buffer. Alpha = IC / IE Beta = IC / IB

Description : How will you test a transistor with a multimeter. ?

Last Answer : 1. Emitter +ve of meter and Base -ve output = Low resistance 2. Emitter -ve of meter and base +ve output = High resistance. 3. Collector +ve and Base -ve output = Low. 4. Collector -ve and base +ve output = High. Emitter : Collector = High Resistance. PNP : Opposite Results. 

Description : What is a thyristor ? What are its uses ?

Last Answer : A thyristor is a special kind of semi conductor device that uses internal feedback to produce latching action. Use : Used for controlling large amounts of load power in motors, heaters, lighting systems etc ... the latches like a open switch. This latch will always stay in open or close position.  

Description : What does a transmitter output start from 3-15 psi or (0.2 - 1 Kg/Cm2) or 4 - 20 ma. etc. ? 

Last Answer : The transmitter output stance from what is known as "live zero". This system has specific advantages : 1. The systems automatically alarms when the signal system becomes inoperative. ... transmitter operating, but transmitting a zero measurement and a failure, in the signal system. 

Description : What are Intrinsically safe system ?

Last Answer : Intrinsic safety is a technique for designing electrical equipment for safe use in locations made hazardous by the presence of flammable gas or vapors in air. "Defn. :" Intrinsically safe circuit is ... , unfortunately, been adopted in all countries. However two sets of codes in common use are.  

Description : What is feed back control ? What is feed forward control ? Discuss its application ?

Last Answer : Feed back control: Feed back control involves the detection of the controlled variable and counteracting of charges its it's value relative to set point, by adjustment of a manipulated ... controller for a particular process application, two factors time and gain must be considered.