. What three factors determine the amplitude of the voltage  induced into a stator winding?

1 Answer

Answer :

The amplitude of the primary voltage, the turns ratio, and the  angular displacement between the rotor and the stator winding.

Related questions

Description : When is the maximum voltage induced into a stator coil?

Last Answer : When the rotor coil is aligned with the stator coil.

Description : What is the amplitude and voltage induced into the rotor when the CX is turned 90º while the CT remains on electrical zero?

Last Answer : The voltage is maximum and in phase with the ac excitation voltage to the CX.

Description : In a three-phase, squirrel-cage type, induction motor the rotating magnetic field is established by the _____________. A. current induced in the rotor windings B. application of a three-phase voltage ... caused by the induced current in the squirrel-cage bars with the magnetic field of the stator

Last Answer : Answer: B

Description : The amount of voltage induced in the windings of an AC generator depends mainly on _____________. A. the number of field poles energized B. the speed at which the stator windings rotate through the magnetic field C. the strength of the magnetic field D. all of the above

Last Answer : Answer: C

Description : The speed of a three-phase squirrel-cage induction-type motor operating in a fixed frequency system is varied by changing the _____________. A. number of phases to the motor B. number of stator poles C. locked rotor current D. resistance of the rotor winding

Last Answer : Answer: B

Description : A three phase slip ring induction motor is fed from the rotor side with stator winding short circuited stator is: (1) Slip frequency (2) Supply frequency (3) Frequency corresponding to rotor speed (4) Zero

Last Answer : A three phase slip ring induction motor is fed from the rotor side with stator winding short circuited stator is: Slip frequency

Description : The amount of voltage induced in the windings of an AC generator depends on ____________. A. the number of conductors in series per winding B. the speed at which the magnetic field passes across the winding C. the strength of the magnetic field D. all of the above

Last Answer : Answer: D

Description : How does the stator receive its voltage?

Last Answer : By the magnetic coupling from the rotor

Description : What two factors determine the frequency of the output voltage of an alternator?

Last Answer : Speed of rotation and number of poles.

Description : What rule should you use to determine the direction of induced emf in a coil?

Last Answer : The left-hand rule for generators.

Description : Three factors responsible for the change in voltage as load is applied to an AC generator are: 1) the drop in resistance in the armature circuit, 2) the change in flux, and 3) the ____________. A. armature winding speed B. inductance load drop C. coil pitch factor D. armature reactance voltage drop

Last Answer : Answer: D

Description : On large generators, space heaters are used to ____________. A. keep the machine at ambient tmperature of the machinery space B. maintain rotor and stator winding temperatures above the dew point ... C. prevent condensation in the lube oil D. prevent electrolysis due to condensation in the bearings

Last Answer : Answer: B

Description : The speed of a squirrel-cage induction motor is determined by the ____________. A. diameter of the stator B. number of stator poles C. rotor winding resistance D. rotor conducting bars resistance

Last Answer : Answer: B

Description : The speed of a squirrel cage induction motor is determined by the _____________. A. diameter of the stator B. number of stator poles C. rotor winding resistance D. bar resistance of the conducting rotor

Last Answer : Answer: B

Description : What are the different types of stator winding in induction motor?

Last Answer : The different types of stator windings are mush winding, lap winding and wave winding.

Description : What are the main types of stator winding faults?

Last Answer : Fault between phase and ground; fault between phases and inter-turn fault involving turns of the same phase winding.

Description : What are the effects of imbalance stator winding resistance?

Last Answer : If the stator winding resistances are imbalance phase to phase give pulsating fluxes and pulsating torque on rotor and vibration may increase. For accurate resistance measurement Kelvin Bridge is used. 

Description : Why 100% winding protection is felt essential for main generator stator E/F protection? (Used in NAPS onwards?)  

Last Answer : At MAPS 4% of winding is not protected. Earlier felt that the Electro magnetic stress due high external fault currents near 4% of neutral may not be high to cause E/F here. But now felt that the mechanical stress can leads to E/F. 

Description : A _______ is used to measure the stator % winding temperature of the generator. (a) thermocouple (b) pyrometer (c) resistance thermometer (d) thermometer

Last Answer : (c) resistance thermometer

Description : A synchro has (A) a 3-phase winding on rotor and a single-phase winding on stator. (B) a 3-phase winding on stator and a commutator winding on rotor. (C) a 3-phase winding on stator and a single-phase winding on rotor. (D) a single-phase winding on stator and a commutator winding on rotor.

Last Answer : Ans: C Synchros : The basic synchro unit called a synchro transmitter. It’s construction similar to that of a Three phase alternator.

Description : For a DC motor, what major component in addition to the field winding and the armature winding is necessary? w) a commutator x) a stator y) a battery z) a rotor

Last Answer : ANSWER: W -- A COMMUTATOR

Description : Which of the following motor has squirrel cage winding on the stator: (1) 3 phase squirrel cage induction motor (2) Single phase squirrel cage pump motor (3) Single phase ceiling fan induction motor (4) Single phase table fan induction motor 

Last Answer : Which of the following motor has squirrel cage winding on the stator: (1) 3 phase squirrel cage induction motor (2) Single phase squirrel cage pump motor (3) Single phase ceiling fan induction motor (4) Single phase table fan induction motor 

Description : A 4-pole, 3-phase, double-layer winding is housed in a 36-slot stator for an ac machine with 60o phase spread. Coil span is 7 short pitches. Number of slots in which top and bottom layers belong to different phases is  (A) 24 (B) 18 (C) 12 (D) 0

Last Answer : A 4-pole, 3-phase, double-layer winding is housed in a 36-slot stator for an ac machine with 60o phase spread. Coil span is 7 short pitches. Number of slots in which top and bottom layers belong to different phases is 24 

Description : A _________ is used to measure the stator % winding temperature of the generator.  (A) Thermocouple (B) Pyrometer (C) Resistance thermometer (D) Thermometer

Last Answer : A Resistance thermometer is used to measure the stator % winding temperature of the generator. 

Last Answer : The purpose of stator winding in the compensated repulsion motor is to improve power factor and provide better speed regulation.

Description : What causes a voltage to be developed across the secondary winding of a transformer?

Last Answer : The magnetic lines generated by the current in the primary cut

Description : If the inductance of a choke-input filter is increased, will the output ripple voltage amplitude (Er) increase or decrease?

Last Answer : Decrease.

Description : What three things prevent a CT rotor from turning when voltages are applied to its stator windings?

Last Answer : The rotor is specially wound, it is never connected to an ac supply, and its output is always applied to a high-impedance load.

Description : What is the major difference between a two-phase and a three-phase stator?

Last Answer : Number and location of field poles.

Description : Slip of the induction machine is 0.02 and the stator supply frequency is 50 Hz. What will be the frequency of the rotor induced emf? (A) 10 Hz. (B) 50 Hz. (C) 1 Hz. (D) 2500 Hz.

Last Answer : Ans: C Given : s = 0.02 ; f = 50 Hz Therefore, frequency of rotor induced emf = s f = 0.02 x 50 = 1.0 Hz

Description : What are the necessary tests to determine the efficiency, voltage regulation, and temperature rise of winding & insulation of transformer?

Last Answer : 1.Direct loading test 2.Open circuit test 3. Short circuit test 4. Sumpner's or back to back test

Description : What three main factors determine the amount of refraction in the ionosphere?

Last Answer : (a) density of ionization of the layer (b) frequency (c) angle at which it enters the layer

Description : . What are two of the three physical factors that determine the values of capacitance and inductance of a transmission line?

Last Answer : (1) Type of line used, (2) dielectric in the line, and (3) length of line.

Description : The way a magnetic head will be used determines how it is constructed. Name three factors that determine the final construction of a magnetic head.

Last Answer : a. Type of head (record, reproduce, or erase). b. Frequencies it will record or reproduce. c. Whether it will be used on a single or multitrack recorder.

Description : What three factors determine the type, size, and shape of an antenna?

Last Answer : Frequency of operation of the transmitter, amount of power to be radiated, and general direction of the receiving set.

Description : Which of the two main types of rotors can have either a single winding or three Y-connected windings?

Last Answer : The drum or wound rotor.

Description : One of the generator or motor bearings is generally insulated from the end housing in order to prevent ________. A. rapid brush wear B. current leakage from the shaft C. excessive field winding heat D. circulation of shaft currents induced in the machine's frame

Last Answer : Answer: D

Description : 28.In a two winding transformer, the emf /turn in secondary winding is always......the induced emf power turn in primary A. equal to k times B. equal to 1/k times C. equal D. greater than

Last Answer : C. equal

Description : 6 In a two winding transformer, the primary and secondary induced emf E1 & E2 are always A. equal in magnitude B. anti phase with each other C. in phase with each other D. determined by load on transformer secondary

Last Answer : C. In phase with each other

Description : What type of indicator is usually placed in the stator circuit of a torque synchro system?

Last Answer : An overload indicator.

Description : What is the relationship between the transmitter and receiver stator voltages when their rotors are in correspondence?

Last Answer : The voltages are equal and oppose each other.

Description : What determines the number of field poles required to establish a rotating magnetic field in a multiphase motor stator?

Last Answer : The number of phases in the applied voltage.

Description : Stator Voltage Control of three phase induction motor

Last Answer : Stator Voltage Control of three phase induction motor

Description : What factors determine the rigidity of a gyro?

Last Answer : Rotor speed, weight, shape.

Description : What factors determine the direction of rotation in a dc motor?

Last Answer : Direction of armature current, and direction of magnetic flux in field.

Description : What factors determine the value of the multiplier resistor?

Last Answer : The current required for full-scale deflection, and the range of the voltage to be measured.

Description : hat two factors determine the directivity pattern of the parasitic array?

Last Answer : Length of the parasitic element (tuning) and spacing between the parasitic and driven elements.

Description : Air gap readings for electrical generating equipment should be taken periodicly. This is to _______. I. determine the condition of the bearings II. prevent damage to the rotor and stator A. I only B. II only C. both I and II D. neither I or II

Last Answer : Answer: C

Description : To determine if a stator coil is grounded, you should use a/an _____________. A. ammeter B. ground detection lamp C. magneto D. megger

Last Answer : Answer: D

Description : What information must be known to determine the component values for a voltage divider?

Last Answer : The source voltage and load requirements (voltage and current).