A concrete block subjected to shear stresses, then the failure may result by
[ A ] Diagonal tension
[ B ] Longitudinal tension
[ C ] Diagonal compression
[ D ] None of the above

1 Answer

Answer :

[ A ] Diagonal tension

Related questions

Description : When the distance between centers of two adjacent rivets connecting the members subjected to either compression or tension exceeds the maximum pitch, then the additional rivets which are not subjected to the ... (a) Packing rivets (b) Long-grip rivets (c) Tacking rivets (d) Auxiliary rivets

Last Answer : (c) Tacking rivets

Description : The shear reinforcement in R.C.C. is provided to resist (A) Vertical shear (B) Horizontal shear (C) Diagonal compression (D) Diagonal tension

Last Answer : Answer: Option D

Description : The base of a column is subjected to moment. If the intensity of bearing pressure due to axial load is equal to stress due to moment, then the bearing pressure between the base and the concrete ... Tension at one end and compression at the other end (d) Compression, verying as a parabolic profile

Last Answer : (b) Zero at one end and compression at the other end

Description : A reinforced concrete cantilever beam is 3.6 m long, 25 cm wide and has its lever arm 40 cm. It carries a load of 1200 kg at its free end and vertical stirrups can carry 1800 kg. Assuming concrete to carry one- ... beam, the number of shear stirrups required, is (A) 30 (B) 35 (C) 40 (D) 45

Last Answer : Answer: Option C

Description : The section of a reinforced beam where most distant concrete fibre in compression and tension in steel attains permissible stresses simultaneously, is called (A) Balanced section B) Economic section (C) Critical section (D) All the above

Last Answer : Answer: Option D

Description : The section of a reinforced beam where most distant concrete fiber in compression and tension in steel attains permissible stresses simultaneously is called (i)Balanced section (ii)Economic section (iii)Critical section [ A ] i [ B ] i and ii [ C ] i and iii [ D ] i, ii and iii

Last Answer : [ D ] i, ii and iii

Description : A pressure conduit laid underground, may not be subjected to  (A) Internal pressure of water  (B) Pressure due to external load  (C) Longitudinal temperature stress  (D) Longitudinal stresses due to unbalanced pressure to bends 

Last Answer : (C) Longitudinal temperature stress 

Description : Pick up the correct statement from the following: (A) An unconfined compression test is a special case of triaxial compression test (B) An unconfined compression test is a special case of direct ... subjected to major principal stress till it fails due to shearing along the plane of the failure

Last Answer : Option A

Description : Minimum shear reinforcement is necessary to [ A ] Prevent brittle shear failure [ B ] Prevent failure due to shrinkage and thermal stresses [ C ] Hold the reinforcements in place while pouring concrete [ D ] All the above.

Last Answer : [ D ] All the above.

Description : Torsional shear stresses are induced in the spring wire when (A) spring is under compression (B) spring is under tension (C) both (A) and (B) (D) none of the above

Last Answer : (C) both (A) and (B)

Description : Shear resistance of concrete in a reinforced concrete beam is dependent on (a) Tension reinforcement in the beam (b) Compression reinforcement in the beam (c ) Shear reinforcement in the beam (d) None of the reinforcements in the beam

Last Answer : (a) Tension reinforcement in the beam

Description : The bolt is subjected to __________ when the nut is tightened by putting the washer beneath it. (A) Tension (B) Shear (C) Compression (D) Bending & tension

Last Answer : Option A

Description : A close coiled helical spring is compressed. Its wire is subjected to A. Compression B. Tension C.Shear D. Torque

Last Answer : B. Tension

Description : Pick up the correct statement from the following: (A) Lateral reinforcement in R.C.C. columns is provided to prevent the longitudinal reinforcement from buckling (B) Lateral reinforcement prevents ... Lateral reinforcement stops breaking away of concrete cover, due to buckling (D) All the above

Last Answer : Answer: Option D

Description : When a load crosses a through type Pratt truss in the direction left to right, the nature of force in any diagonal member in the left half of the span would (A) Change from compression to tension (B) Change from tension to compression (C) Always be compression (D) Always be tension

Last Answer : (A) Change from compression to tension

Description : The longitudinal shearing stresses acting on the surface between the steel and concrete are called. (a) Bond stress (b) Tensile stresses (c) Compressive stresses (d) None of these

Last Answer : (a) Bond stress

Description : Flanged beams are preferred when the concrete in the slab is on the [ A ] compression side of the beam [ B ] tension side of the beam [ C ] may be compression side or tension side of the beam [ D ] none of the above

Last Answer : [ A ] compression side of the beam

Description : Flanged beams are preferred when the concrete in the slab is on the [ A ] compression side of the beam [ B ] tension side of the beam [ C ] may be compression side or tension side of the beam [ D ] none of the above

Last Answer : [ A ] compression side of the beam

Description : A pre-stressed concrete member is preferred because (A) Its dimensions are not decided from the diagonal tensile stress (B) Large size of long beams carrying large shear force need not be adopted (C) Removal of cracks in the members due to shrinkage (D) All the above

Last Answer : Answer: Option D

Description : In a singly reinforced beam (A) Compression is borne entirely by concrete (B) Steel possesses initial stresses when embedded in concrete (C) Plane sections transverse to the centre line ... Elastic moduli for concrete and steel have different values within the limits of deformation of the beam

Last Answer : Answer: Option C

Description : If permissible working stresses in steel and concrete are respectively 1400 kg/cm2 and 80 kg/cm2 and modular ratio is 18, in a beam reinforced in tension side and of width 30 cm and having effective depth 46 cm, the lever arms of the section, is (A) 37 cm (B) 38 cm (C) 39 cm (D) 40 cm

Last Answer : Answer: Option D

Description : Inc case of prestressed concrete members, the bursting stresses develop at (a) Bond zone (b) Maximum bending moment zone (c ) Maximum shear stress zone (d) Anchorage zone

Last Answer : (d) Anchorage zone

Description : Reinforced cement concrete is equally strong in taking (a) Tensile and compressive stress (b) Compressive and shear stresses. (c) Tensile, compressive and shear stresses. (d) Tensile and shear stresses.

Last Answer : (c) Tensile, compressive and shear stresses.

Description : In general in the design of a section by limit method, it is assumed that [ A ] the stress in steel to reach its yield limit before concrete failure [ B ] the stress in concrete to ... in both concrete and steel reach their permissible values simultaneously [ D ] none of the above are correct

Last Answer : [ A ] the stress in steel to reach its yield limit before concrete failure

Description : In general in the design of a section by limit method, it is assumed that [ A ] the stress in steel to reach its yield limit before concrete failure [ B ] the stress in concrete to ... in both concrete and steel reach their permissible values simultaneously [ D ] none of the above are correct

Last Answer : [ A ] the stress in steel to reach its yield limit before concrete failure

Description : The helical spring ad wire of helical torsion spring, both are subjected to torsional shear stresses. a) True b) False

Last Answer : b) False

Description : During transverse vibrations, shaft is subjected to which type of stresses? A) Tensile stresses B) Torsional shear stress C) Bending stresses D) All of the above

Last Answer : C) Bending stresses

Description : During transverse vibrations, shaft is subjected to which type of stresses? a. Tensile stresses b. Torsional shear stress c. Bending stresses d. All of the above

Last Answer : c. Bending stresses

Description : The possible loading in various members of framed structures are  (A) Compression or tension  (B) Buckling or shear  (C) Shear or tension  (D) All of the above 

Last Answer : (A) Compression or tension

Description : When a bar is subjected to a change of temperature and its longitudinal deformation is prevented, the stress induced in the bar is (a) Tensile (b) Compressive (c) Shear (d) Temperature

Last Answer : (d) Temperature

Description : The type of aggregates not suitable for high strength concrete and for pavements subjected to tension, is (A) Rounded aggregate (B) Irregular aggregate (C) Angular aggregate (D) Flaky aggregat

Last Answer : Answer: Option A

Description : Select the incorrect statement. (A) In a direct shear box test, the plane of shear failure is predetermined (B) Better control is achieved on the drainage of the soil in a triaxial compression ... compression test is uniform (D) Unconfined compression test can be carried out on all types of soils

Last Answer : Answer: Option D

Description : In pre-stressed concrete (A) Forces of tension and compression change but lever arm remains unchanged (B) Forces of tension and compressions remain unchanged but lever arm changes with the moment ( ... arm change (D) Both forces of tension and compression as well as lever arm remain unchanged

Last Answer : Answer: Option B

Description : Pick up the correct statement from the following: (A) Plain cement concrete is equally strong in compression as well as in tension (B) Slump test is performed to check concrete strength (C ... D) Fineness modulus is the index number expressing the relative sizes of both coarse and fine aggregates

Last Answer : Option D

Description : In a singly reinforced concrete beam, as the load increases. (a) Only concrete will resist tension (b) Only steel bars will resist tension. (c) Both concrete and steel will resist tension. (d) Both concrete and steel will resist compression.

Last Answer : (b) Only steel bars will resist tension.

Description : In a singly reinforced concrete beam, if the load is vey small. (a) Only concrete will resist tension (b) Only steel bars will resist tension. (c) Both concrete & steel will resist tension. (d) Both concrete & steel will resist compression.

Last Answer : (c) Both concrete & steel will resist tension.

Description : The equilibrium equation for the condition that tension will be equal to the compression is given by [ A ] Compression in concrete = Tension in steel [ B ] Compression in concrete + Compression in steel = Tension in steel [ C ] Compression in concrete = Compression in steel [ D ] None of the above

Last Answer : [ B ] Compression in concrete + Compression in steel = Tension in steel

Description : Select the incorrect statement from the following In eccentrically loaded columns, [ A ] The tensile strength of concrete is ignored [ B ] Design stress - strain curve for steel in compression is the ... different points in the section will be same [ D ] Plane section remain plane even after bending

Last Answer : [ C ] The strain at different points in the section will be same

Description : Concrete is [ A ] Weak in tension [ B ] Strong in tension [ C ] Strong in both tension and compression [ D ] Weak in compression

Last Answer : [ A ] Weak in tension

Description : Design shear strength of concrete is a function of i.Percentage of tension steel ii.Grade of concrete iii.Grade of steel [ A ] i and ii [ B ] ii only [ C ] i and iii [ D ] i, ii and iii

Last Answer : [ A ] i and ii

Description : Under complex loading, if elastic limit reaches in tension, then failure occurs due to (a) Firstly Maximum principal strain theory (b) Secondly Maximum principal theory of strain energy (c) Thirdly Maximum shear stress theory (d) None

Last Answer : (d) None

Description : The compression in concrete (fc) at failure is given by [ A ] 0.30 fck [ B ] 0.45 fck [ C ] 0.50 fck [ D ] 0.75 fck

Last Answer : [ B ] 0.45 fck

Description : The concrete is assumed to reach failure with a compression strain of [ A ] 0.002 [ B ] 0.0035 [ C ] 0.0045 [ D ] 0.006

Last Answer : [ B ] 0.0035

Description : The concrete is assumed to reach failure with a compression strain of [ A ] 0.002 [ B ] 0.0035 [ C ] 0.0045 [ D ] 0.006

Last Answer : [ B ] 0.0035

Description : A beam is a structural member which is subjected to (a) Axial tension or compression (b) Transverse loads and couples (c) Twisting moment (d) No load, but its axis should be horizontal and x-section rectangular or circular

Last Answer : b) Transverse loads and couples

Description : When the helical compression spring is subjected to axial compressive force, the type of stress induced in the spring wire is, (A) Tensile stress (B) Compressive stress (C) Bending stress (D) Torsional shear stress

Last Answer : (D) Torsional shear stress

Description : Under maximum shear stress theory, maximum shear stress is equal to (a) Allowable stress in tension (b) Allowable stress in compression (c) Allowable stress in shear (d) None

Last Answer : (c) Allowable stress in shear

Description : Under maximum principal stress theory, maximum principal stress is equal to (a) Allowable stress in tension (b) Allowable stress in compression (c) Allowable stress in shear (d) None

Last Answer : (a) Allowable stress in tension

Description : Suitability of steel for its use in cable is judged by its strength in (A) Tension (B) Compression (C) Torsion (D) Shear

Last Answer : (A) Tension

Description : A thin cylindrical shell under internal pressure can fail by a. Shear b. Compression c. Tension d. None

Last Answer : c. Tension