The Maximum spacing of the longitudinal bars measured long the periphery of the column should be
[ A ] 250 mm
[ B ] 300 mm
[ C ] 400 mm
[ D ] 450 mm

1 Answer

Answer :

[ B ] 300 mm

Related questions

Description : Which of the following statements is incorrect? (A) Minimum cross sectional area of longitudinal reinforcement in a column is 0.8% (B) Spacing of longitudinal bars measured along the periphery of ... (D) The number of longitudinal bars provided in a circular column should not be less than four

Last Answer : Answer: Option D

Description : According to IS: 456-2000 Maximum spacing of shear reinforcement in no case shall not exceed [ A ] 250 mm [ B ] 300 mm [ C ] 350 mm [ D ] 450 mm

Last Answer : [ B ] 300 mm

Description : The maximum spacing of main steel in slabs has been limited to [ A ] 250 mm [ B ] 300 mm [ C ] 450 mm [ D ] 500 mm

Last Answer : [ B ] 300 mm

Description : The Maximum spacing of Secondary reinforcement in slabs should be [ A ] Less than 450 mm [ B ] Less than 300 mm [ C ] Smaller of three times the effective depth and 450 mm [ D ] Smaller of five times the effective depth and 450 mm

Last Answer : [ D ] Smaller of five times the effective depth and 450 mm

Description : If the width of a pavement slab is 7.5 m, thickness 20 cm and working stress 1400 kg/cm2 , spacing of 10 mm tie bars for the longitudinal joint, is (A) 10 cm (B) 20 cm (C) 30 cm (D) 40 cm

Last Answer : Answer: Option C

Description : According to IS: 456-2000 spacing of vertical stirrups for shear reinforcement has been limited to [ A ] 0.75 d [ B ] 450 mm [ C ] lesser of 0.75 d or 300 mm [ D ] lesser of 0.75d or 450 mm

Last Answer : [ C ] lesser of 0.75 d or 300 mm

Description : A simply supported rolled steel joist 8 m long carries a uniformly distributed load over it span so  that the maximum bending stress is 75 N/mm². If the slope at the ends is 0.005 radian and the  value of E = 0.2 ... joist, is  (A) 200 mm  (B) 250 mm  (C) 300 mm  (D) 400 mm 

Last Answer : (D) 400 mm 

Description : The diameter of longitudinal bars of a column should never be less than (A) 6 mm (B) 8 mm (C) 10 mm (D) 12 mm

Last Answer : Answer: Option D

Description : If the diameter of longitudinal bars of a square column is 16 mm, the diameter of lateral ties should not be less than (A) 4 mm (B) 5 mm (C) 6 mm (D) 8 mm

Last Answer : Answer: Option B

Description : The minimum diameter of longitudinal bars in a column is (A) 6 mm (B) 8 mm (C) 12 mm (D) 16 mm

Last Answer : Answer: Option C

Description : Select the incorrect statement from the following [ A ] Reinforcing bars in a column should not be less than 12 mm in diameter [ B ] The number of longitudinal bars in a circular column should not ... The minimum percentage of longitudinal steel in columns should be 0.8% [ D ] None of the above

Last Answer : [ B ] The number of longitudinal bars in a circular column should not exceed four

Description : Maximum root zone depth for Maize (a) 200-300 mm (b) 400-600 mm (c) 500-600 mm (d) 350- 450 mm

Last Answer : (b) 400-600 mm

Description : Sum of tread and rise must lie between (A) 300 to 350 mm (B) 400 to 450 mm (C) 500 to 550 mm (D) 600 to 650 mm

Last Answer : Answer: Option B

Description : An R.C.C. column of 30 cm diameter is reinforced with 6 bars 12 mm placed symmetrically along the circumference. If it carries a load of 40, 000 kg axially, the stress is (A) 49.9 kg/cm2 (B) 100 kg/cm2 (C) 250 kg/cm2 (D) 175 kg/cm

Last Answer : Answer: Option A

Description : Hot extrusion of aluminium is done in the temperature range of __________ °C. (A) 550-600 (B) 450-500 (C) 350-400 (D) 250-300

Last Answer : (C) 350-400

Description : If At is the area of steel cross-section, t is working stress, L is width of road and W is weight of slab per square metre, the spacing of the tie bars for a longitudinal joint, is (A) (100 At × t)/WL (B) 100 At/tWL (C) (100 WAt × t)/tL (D) 100 WL/At t

Last Answer : Answer: Option D

Description : The torsion resisting capacity of a given reinforced concrete section. (a) Decreases with decrease in stirrups spacing. (b) Decreases with increase in longitudinal bars. (c) Does not depend upon stirrups and longitudinal steels. (d) Increases with increase in stirrups and longitudinal steels.

Last Answer : (d) Increases with increase in stirrups and longitudinal steels.

Description : The maximum of spacing of side face reinforcement shall not exceed [ A ] 300 mm [ B ] Web thickness [ C ] Lesser of (a) and (b) [ D ] Greater of (a) and (b)

Last Answer : [ C ] Lesser of (a) and (b)

Description : The spacing of transverse reinforcement of column is decided by the following consideration. (A) The least lateral dimension of the column (B) Sixteen times the diameter of the smallest longitudinal ... column (C) Forty-eight times the diameter of transverse reinforcement (D) All the above

Last Answer : Answer: Option D

Description : According to IS: 456 -2000, the spacing of links in a Column should be less than [ A ] 16 x diameter of smallest longitudinal bar [ B ] 24 x diameter of smallest longitudinal bar [ C ] 48 x diameter of smallest longitudinal bar [ D ] 48 x diameter of greatest longitudinal bar

Last Answer : [ A ] 16 x diameter of smallest longitudinal bar

Description : The main reinforcement of a R.C. slab consists of 10 mm bars at 100 mm spacing; if it is desired to replace the 10 mm bars by 12 mm bars, then the spacing of 12mm bars should be (a) 120 mm (b) 140 mm (c ) 144 mm (d) 160mm

Last Answer : (c ) 144 mm

Description : Flat rate parcel rates Flat Rate Parcel Boxes size Dimension of boxes (in mm) Weight (in Kg.) Tariff (in Rs.) Small - S 250*50*300 0 to 1 125 Medium - M 250*100*300 Above 1 to 2.5 200 Large - L 300*250*200 Above 2.5 to 5 400

Last Answer : Large - L 300*250*200 Above 2.5 to 5 400

Description : The purpose of lateral ties in short R.C. columns is to (a) Increase the load carrying capacity of column (b) Facilitate compaction of concrete (c) Facilitate construction (d) Avoid buckling of longitudinal bars

Last Answer : (d) Avoid buckling of longitudinal bars

Description : Side face reinforcement is provided when the depth of beam exceeds [ A ] 250 mm [ B ] 450 mm [ C ] 550 mm [ D ] 750 mm

Last Answer : [ D ] 750 mm

Description : The value of 'C' of Indian type W.C. shown in the given figure is: (A) 400 mm (B) 450 mm (C) 500 mm (D) 550 mm

Last Answer : (C) 500 mm

Description : In cement pressure grouting holes should be drilled at spacing in both direction at a) 150 – 500 mm b) 450 mm c) 500 – 750 mm* d) 1000 mm

Last Answer : c) 500 – 750 mm*

Description : The size of a plane table is (A) 750 mm × 900 mm (B) 600 mm × 750 mm (C) 450 mm × 600 mm (D) 300 mm × 450 mm

Last Answer : (B) 600 mm × 750 mm

Description : While placing of concrete the thickness of each layer for R.C.C. is [ A ] 150 to 300 mm [ B ] 450 mm [ C ] 500 to 750 mm [ D ] 500 mm

Last Answer : [ A ] 150 to 300 mm

Description : The spacing of bars of perforations of fine screens used for the treatment of sewage, is A. 2 to 3 mm B. 3 to 5 mm C. 5 to 8 mm D. 8 to 10 mm

Last Answer : ANS: A

Description : The spacing of bars for perforations in coarse screens used for the treatment of sewage, is A. 20 mm B. 30 mm C. 40 mm D. 50 mm

Last Answer : ANS: D

Description : For a longitudinal reinforcing bar in a column, the minimum cover shall neither be less than the diameter of bar nor less than (A) 15 mm (B) 25 mm (C) 30 mm (D) 40 mm

Last Answer : Answer: Option D

Description : Minimum cover to longitudinal steel in a column should be (if the diameter of bar, Ø> 12mm) [ A ] 25 mm [ B ] 30 mm [ C ] 40 mm [ D ] 50 mm

Last Answer : [ C ] 40 mm

Description : A short column 20 cm 20 cm in section is reinforced with 4 bars whose area of cross section is 20 sq. cm. If permissible compressive stresses in concrete and steel are 40 kg/cm2 and 300 kg/cm2 , the Safe load on ... should not exceed (A) 4120 kg (B) 41,200 kg (C) 412,000 kg (D) None of these

Last Answer : Answer: Option B

Description : If a concrete column 200 200 mm in cross-section is reinforced with four steel bars of 1200  mm2  total cross-sectional area. Calculate the safe load for the column if permissible stress in  concrete is 5 N/mm2 ... 15 Ec (A) 264 MN  (B) 274 MN  (C) 284 MN  (D) 294 MN 

Last Answer : (C) 284 MN 

Description : Minimum clear cover (in mm) to the main steel bars in slab, beam, column and footing respectively, are (a) 10, 15, 20 and 25 (b) 15, 25, 40 and 75 (c ) 20, 25, 30 and 40 (d) 20, 35, 40 and 75

Last Answer : (b) 15, 25, 40 and 75

Description : The normal concentration of chloride in mg/100 ml of whole blood is about (A) 200 (B) 250 (C) 400 (D) 450

Last Answer : Answer : B

Description :  P and Q undertake to do a piece of job for Rs.1200. P alone can do it in 12 days while Q alone can do it in 16 days. With the help of R , they finish it in 6 days. Find the share of P,Q & R. a) 400,600,200 b) 200,400,600 c) 450,400,250 d) 600,450,150

Last Answer : D R;s 1 day work = 1/6 – (1/12 + 1/16) =1/6 – 1/12 – 1/16 = (8-4-3)/48 = 1/48 P:Q:R = ratio of 1 day work = 1/12:1/16 : 1/48 =4:3:1 P’s share = Rs(1200*4/8) =Rs.600 Q’s share = Rs(1200 * 3/8) =Rs.450 R’s share = Rs(1200 * 1/8) =Rs.150

Description : A square object of 4 mm is subjected to a force of 3000 N. What is the maximum allowable shear stress acting on it? a. 250.14 mm2 b. 281.25 mm2 c. 400.32 mm2 d. 500 mm2

Last Answer : b. 281.25 mm2

Description : Critical section for shear in case of flat slabs is at a distance of (A) Effective depth of slab from periphery of column/drop panel (B) d/2 from periphery of column/capital/ drop panel (C) At the drop panel of slab (D) At the periphery of column

Last Answer : Answer: Option B

Description : What is the average weight of Human Heart? A. 300 gram (Answer) B. 350 gram C. 400 gram D. 450 gram

Last Answer : A. 300 gram (Answer)

Description : What is the range of the visible light cure beam: A. 100-120 nm B. 200-300 nm C. 400-430 nm D. 470 nm or 450-500 nm

Last Answer : D. 470 nm or 450-500 nm

Description : It has Staggered pegs in two rows at Spacing. A. 100 mm. C. 400 mm B. 200 mm D. 50 mm

Last Answer : 200 mm

Description : To pump water from a water reservoir 3 m deep and maximum water level at 135 m, a pump is  installed to lift water up to R.L. 175 m at a constant rate of 36,00,000 litres per hour. If the length  of the ... the water horse power of the pump is  (A) 400  (B) 450  (C) 500 (D) 600

Last Answer : (D) 600

Description : Pick up the wrong nominal internal diameter of cast iron (spun) pipes in mm from the following: (A) 300 (B) 400 (C) 550 (D) 650

Last Answer : (C) 550

Description : A sewer has a diameter of 300 mm and slop of 1 in 400. While running full it has a mean velocity of 0.7 m/s. If both the diameter and slope are doubled (to respectively be 600 mm and 1 in 200), what will be the changed mean velocity ... 's formula. (a) 1.59 m/s (b) 2.80 m/s (c) 0.90 m/s (d) 1.00 m/s

Last Answer : (a) 1.59 m/s

Description : Match List-I (crops) with List-II (water requirement) and select your answer from the code given below- List-I (a) Jowar (b) Soybean (c) Cotton (d) Groundnut List-II 1. 140 mm - 300 mm 2. 350 mm - 450 mm 3. 200 mm - 300 mm 4. 300 mm - ... (b) (c) (d) (A) 3 1 2 4 (B) 4 2 3 1 (C) 1 4 2 3 (D) 3 1 4 2

Last Answer : (C) 1 4 2 3

Description : n Girder and Slab Bridges Danger level should be marked below bottom of girders/slabs for water way is > 12.20 < 30.5 m a) 300 mm b) 600 mm* c) 500 mm d) 450 mm

Last Answer : b) 600 mm*

Description : In Girder and Slab Bridges Danger level should be marked below bottom of girders/slabs for water way is > 6.10 < 12.2 m a) 300 mm b) 600 mm c) 450 mm* d) 500 mm

Last Answer : c) 450 mm*

Description : Explain the requirements of good formwork with names and materials proposed for beam of size 300 X 450 mm with neat labeled sketch.  

Last Answer : Requirements of good formwork:- 1. It should be adequately strong to withstand an extensive variety of dead and live loads. For instance, self-weight, weight of reinforcement, weight of wet concrete, loads of ... of concreting. 8. It should be lightweight. 9. It should be easy to remove.

Description : According to IS: 456-2000, the maximum cement content exclusive of admixtures is [ A ] 200 kg/m3 [ B ] 300 kg/m3 [ C ] 450 kg/m3 [ D ] 550 kg/m3

Last Answer : [ C ] 450 kg/m3