If plain bars are used, the area of distribution reinforcement in slabs should not less than
(a) 0.12% of the gross area f concrete
(b) 0.15% of the gross area of concrete
(c) 0.18% of the gross area of concrete
(d) 0.20% of the gross area of concrete

1 Answer

Answer :

(b) 0.15% of the gross area of concrete

Related questions

Description : If high yield strength deformed bars are used, the are of distribution reinforcement in slabs, should not less than. (a) 0.12% of the gross area of concrete (b) 0.15% of the gross area of concrete (c) 0.18% of the gross area of concrete (d) 0.20% of the gross area of concrete

Last Answer : (a) 0.12% of the gross area of concrete

Description : Minimum reinforcement in slabs, when High yield strength deformed bars [ A ] 0.12% of gross cross sectional area [ B ] 0.15% of gross cross sectional area [ C ] 0.20% of gross cross sectional area [ D ] 0.25% of gross cross sectional area.

Last Answer : [ A ] 0.12% of gross cross sectional area

Description : The Minimum percentage of secondary steel in slabs for Fe- 415 grade steel should be __________ of Gross cross-section area [ A ] 0.12% [ B ] 0.15% [ C ] 0.20% [ D ] 0.25%

Last Answer : [ A ] 0.12%

Description : The diameter of bars used for distribution reinforcement in slabs, may vary from (a) 2 to 4mm (b) 4 to 6mm (c) 6mm to 8mm (d) 8 to 12mm

Last Answer : (c) 6mm to 8mm

Description : The percentage of reinforcement in case of slabs, when high strength deformed bars are used is not less than (A) 0.15 (B) 0.12 (C) 0.30 (D) 1.00

Last Answer : Answer: Option B

Description : The percentage of minimum reinforcement of the gross sectional area in slabs, is (A) 0.10 % (B) 0.12 % (C) 0.15 % (D) 0.18 %

Last Answer : Answer: Option C

Description : Bank of India has sold how much percent of its stake in Star Union Dai-Ichi Life insurance to Dai-Ichi? A) 18% B) 26% C) 38% D) 15% E) 12%

Last Answer : A) 18% Explanation: The shareholding of Dai-Ichi in the Indian life insurance venture will now increase from 26% to 44% while Bank of India‘s shareholding will decrease from 30% to 48%. Union Bank will continue to hold 26%.

Description : The marked price of a watch was Rs. 720.A man brought the same for Rs.550.80 after getting two successive discounts the first being 10% .What was the second discount rate? A. 12% B. 14% C. 15% D. 18%

Last Answer : Answer – C. 15% Explanation – Let the second discount rate be x% Then, (100 – x)% of 90% of 720 = 550.80 => (100 – x)/100 x 90/100 x 720 = 550.80 = (100-x) = [55080/(9 x 72) = 85 => x= 15 second discount rate =15%

Description : The volume shrinkage of methyl metacrylate monomer when polymerized is:** A. 12% B. 15% C. 18% D. 21%

Last Answer : D. 21%

Description : The diameter of bars for main reinforcement in slabs, may be (a) 2 to 4mm (b) 4 to 8mm (c) 8 to 14mm (d) 14 to 18mm

Last Answer : (c) 8 to 14mm

Description : Minimum steel in the main direction of a slab when using high yield steel [ A ] 0.12% [ B ] 0.15% [ C ] 0.20% [ D ] 0.25%

Last Answer : [ B ] 0.15%

Description : Food must be moist, with a minimum water content of _____before contamination by microorganisms and spoilage can occur. a. 18% to 20% b. 10 to 15% c. 5 to 10% d. 0 to 5%

Last Answer : a. 18% to 20%

Description : Few items of P/L A/c of a company are– Sales – Rs.1,60,000 Closing stock – Rs.38,000 Non-operating Expenses – Rs.800 Non-operating Income – Rs.4,800 Net Profit – Rs.28,000 What is the Operating Profit Ratio ? (A) 18% (B) 20% (C) 15% (D) 57%

Last Answer : Answer: 15%

Description : Protein content of rice is about (A) 7% (B) 12% (C) 15% (D) 20%

Last Answer : Answer : A

Description : Protein content of cereals ranges from (a) 8-12% (b) 12-15% (c) 15-20% (d) 20-25%

Last Answer : (a) 8-12%

Description : A article is listed at Rs. 2000 and a discount of 20% is offered on the list price .What additional discount must be offered to the customer bring the net price to Rs. 1400? A. 12.5% B. 10% C. 12% D. 15%

Last Answer : Answer – A. 12.5% Explanation – S.P after 1st discount, 100%………2000 80%………? ?=2000×80/100=1600 Net S.P = Rs. 1400. Discount on Rs. 1600 = Rs. 200. ∴Required discount = (200/1600 x 100)% =12.5%

Description : Which of the following statements is incorrect? (A) Minimum cross sectional area of longitudinal reinforcement in a column is 0.8% (B) Spacing of longitudinal bars measured along the periphery of ... (D) The number of longitudinal bars provided in a circular column should not be less than four

Last Answer : Answer: Option D

Description : The Maximum spacing of Secondary reinforcement in slabs should be [ A ] Less than 450 mm [ B ] Less than 300 mm [ C ] Smaller of three times the effective depth and 450 mm [ D ] Smaller of five times the effective depth and 450 mm

Last Answer : [ D ] Smaller of five times the effective depth and 450 mm

Description : The Maximum spacing of Main reinforcement „m‟ slabs shall be [ A ] Less than three times of the effective depth [ B ] Less than 300mm [ C ] Smaller of (a) and (b) [ D ] Greater of (a) and (b)

Last Answer : [ C ] Smaller of (a) and (b)

Description : If the diameter of the main reinforcement in a slab is 16 mm, the concrete cover to main bars is (A) 10 mm (B) 12 mm (C) 14 mm (D) 16 mm

Last Answer : Answer: Option D

Description : In the reinforced cement concrete structure, the steel reinforcement consists of . (a) Deformed bars (b) Cold twisted bars (c) Mildsteel and medium tensile steel bars (d) All of these

Last Answer : (d) All of these

Description : As per IS: 456, permissible bond stress for plain bars in tension, in working stress method, where M20, is the grade of concrete [ A ] 0.6 N/mm2 [ B ] 0.8 N/mm2 [ C ] 1.0 N/mm2 [ D ] 1.2 N/mm2

Last Answer : [ B ] 0.8 N/mm2

Description : Stainless steel contains (A) 18% of chromium and 8% nickel (B) 8% of chromium and 18% of nickel (C) 12% of chromium and 36% of nickel (D) 36% of chromium and 12% of nickel

Last Answer : Answer: Option A

Description : The strength of concrete after one year as compared to 28 days strength is about (A) 10 to 15% more (B) 15 to 20% more (C) 20 to 25% more (D) 25 to 50% more

Last Answer : Answer: Option C

Description : Normally, the tensile strength of concrete is about____________of its compressive strength (a) 10 to 15% (b) 15 to 20% (c) 20 to 25% (d) 25 to 30%

Last Answer : (a) 10 to 15%

Description : The strength of concrete using air entraining cement gets reduced by (a) 5 to 10% (b) 10 to 15% (c) 15 to 20% (d) 20 to 25%

Last Answer : (b) 10 to 15%

Description : The percentage of reinforcement in slabs is generally in the range of [ A ] 0.3% to 0.5% [ B ] 0.5% to 1.0% [ C ] 1.0% to 1.5% [ D ] 1.5 % to 2.0%

Last Answer : [ A ] 0.3% to 0.5%

Description : The ultimate average anchorage bond stress for plain bars in tension is _______ if the grade of concrete is M20 [ A ] 1.60 N/mm2 [ B ] 1.92 N/mm2 [ C ] 2.24 N/mm2 [ D ] 2.40 N/mm2

Last Answer : [ B ] 1.92 N/mm2

Description : The ultimate average anchorage bond stress for plain bars in tension is _______ if the grade of concrete is M20 [ A ] 1.60 N/mm2 [ B ] 1.92 N/mm2 [ C ] 2.24 N/mm2 [ D ] 2.40 N/mm2

Last Answer : [ B ] 1.92 N/mm2

Description : Maximum percentage reinforcement in case of slabs is limited to (A) 2 (B) 4 (C) 6 (D) 8

Last Answer : (B) 4

Description : In slabs the Maximum horizontal distance between parallel main reinforcement should not exceed i.Three times effective depth ii Five times effective depth iii 300mm iv 450 mm [ A ] i and iii [ B ] i and iv [ C ] ii and iii [ D ] ii and iv

Last Answer : [ A ] i and iii

Description : The Minimum amount of steel for Main reinforcement in slab should be (Fe 415- grade of steel) [ A ] 0.12 percent of gross cross sectional area [ B ] 0.15 percent of gross cross sectional area [ C ] 0.20 percent of gross cross sectional area [ D ] 0.25 percent of gross cross sectional area.

Last Answer : [ A ] 0.12 percent of gross cross sectional area

Description : A Barbie doll is available at Ratna stores in salem at 20% discount and the same is available at only 18% discount at Royal stores in attur. Deepika has just sufficient amount of Rs 800 to purchase ... is the amount that deepika has less than required amount to purchase it at Royal stores in attur?

Last Answer : 80%= 800 100%= 1000 when discount 18%,then, SP= 1000-180=820 required difference= 820-800 = Rs. 20

Description : Under GST, Smartphones will be taxed at ................... per cent. (A) 14% (B) 12% (C) 18% (D) 5%

Last Answer : (B) 12%

Description : In India, the GST Council has come out with a four-rate structure. They are? (A) 5%, 12%, 18% and 24% (B) 5%, 12%, 18% and 26% (C) 5%, 12%, 18% and 28% (D) 5%, 12%, 16% and 28%

Last Answer : (C) 5%, 12%, 18% and 28%

Description : The highest rate of tax prescribed under IGST is– (A) 5% (B) 12% (C) 18% (D) 28%

Last Answer : (D) 28%

Description : The limits of percentage p of the longitudinal reinforcement in a column is given by (A) 0.15% to 2% (B) 0.8% to 4% (C) 0.8% to 6% (D) 0.8% to 8%

Last Answer : Answer: Option C

Description : A person sold one-third of the total quantity of goods at a profit of 15%. At what profit percent should the remaining quantity be sold so that he makes an overall gain of 21%? 1 : 18% 2 : 27% 3 : 33% 4 : 30% 5 : None of these

Last Answer : 5 : None of these

Description : On selling a fan at 8% loss and an iron box at 18% gain, a man gains rs.346.If he sells the fan at 7% gain and the iron box at 15% gain, then he gains rs.450. The actual price of the iron box is approximately?

Last Answer : Let the cost price of the fan be Rs X and Cost of the iron box beRs Y Then 18%Y – 8% X=346 ; That is 18Y-8X=34600 1 And 15%Y+8% X=450 ; that is 15Y+8X=450002 Solving 1 and 2 we get X=1102.275 Y=2412.12 therefore cost of ironbox is = 2412(approx.)

Description : When the nominal shear stress is less than permissible shear stress in concrete then [ A ] Provide minimum shear reinforcement [ B ] No shear reinforcement is necessary [ C ] Provide design shear reinforcement [ D ] None of the above

Last Answer : [ A ] Provide minimum shear reinforcement

Description : A concrete using an air entrained cement (A) Has strength less than 10% to 15% (B) Has more resistance to weathering (C) Is more plastic and workable (D) Is free from segregation and bleeding

Last Answer : Answer: Option C

Description : Lapped splices in tensile reinforcement are generally not used for bars of size larger than (A) 18 mm diameter (B) 24 mm diameter (C) 30 mm diameter (D) 36 mm diameter

Last Answer : Answer: Option D

Description : The amount of reinforcement for main bars in a slab, is based upon (A) Minimum bending moment (B) Maximum bending moment (C) Maximum shear force (D) Minimum shear force

Last Answer : Answer: Option B

Description : Pick up the incorrect statement from the following: Tensile reinforcement bars of a rectangular beam (A) Are curtailed if not required to resist the bending moment (B) Are bent up at suitable ... to serve as shear reinforcement (D) Are maintained at bottom to provide at least local bond stress

Last Answer : Answer: Option C

Description : When shear stress exceeds the permissible limit in a slab, then it is reduced by (A) Increasing the depth (B) Providing shear reinforcement (C) Using high strength steel (D) Using thinner bars but more in number

Last Answer : Answer: Option A

Description : The main reinforcement of a R.C. slab consists of 10 mm bars at 100 mm spacing; if it is desired to replace the 10 mm bars by 12 mm bars, then the spacing of 12mm bars should be (a) 120 mm (b) 140 mm (c ) 144 mm (d) 160mm

Last Answer : (c ) 144 mm

Description : The amount of reinforcement for main bars in a slab, is based upon (a) Maximum bending moment (b) Minimum bending moment (c) Maximum shear force (d) Minimum shear force

Last Answer : (a) Maximum bending moment

Description : The pitch of bars of main reinforcement in slab should not exceed ________the effective depth of slab. (a) Double (b) Three times (c) Five times (d) Six times

Last Answer : (b) Three times

Description : A stirrups consists of ____________diameter mildsteel bars bent round the tensile reinforcement (a) 1 to 5mm (b) 5 to 12mm (c) 12 to 18mm (d) All the above

Last Answer : (b) 5 to 12mm

Description : Shear reinforcement is provided in the form of (a) Vertical bars (b) Inclined bars (c) Combination of vertical and inclined bars (d) All the above

Last Answer : (d) All the above