The percentage of minimum reinforcement of the gross sectional area in slabs, is
(A) 0.10 %
(B) 0.12 %
(C) 0.15 %
(D) 0.18 %

1 Answer

Answer :

Answer: Option C

Related questions

Description : Minimum reinforcement in slabs, when High yield strength deformed bars [ A ] 0.12% of gross cross sectional area [ B ] 0.15% of gross cross sectional area [ C ] 0.20% of gross cross sectional area [ D ] 0.25% of gross cross sectional area.

Last Answer : [ A ] 0.12% of gross cross sectional area

Description : The Minimum amount of steel for Main reinforcement in slab should be (Fe 415- grade of steel) [ A ] 0.12 percent of gross cross sectional area [ B ] 0.15 percent of gross cross sectional area [ C ] 0.20 percent of gross cross sectional area [ D ] 0.25 percent of gross cross sectional area.

Last Answer : [ A ] 0.12 percent of gross cross sectional area

Description : The percentage of reinforcement in slabs is generally in the range of [ A ] 0.3% to 0.5% [ B ] 0.5% to 1.0% [ C ] 1.0% to 1.5% [ D ] 1.5 % to 2.0%

Last Answer : [ A ] 0.3% to 0.5%

Description : The percentage of reinforcement in case of slabs, when high strength deformed bars are used is not less than (A) 0.15 (B) 0.12 (C) 0.30 (D) 1.00

Last Answer : Answer: Option B

Description : If high yield strength deformed bars are used, the are of distribution reinforcement in slabs, should not less than. (a) 0.12% of the gross area of concrete (b) 0.15% of the gross area of concrete (c) 0.18% of the gross area of concrete (d) 0.20% of the gross area of concrete

Last Answer : (a) 0.12% of the gross area of concrete

Description : If plain bars are used, the area of distribution reinforcement in slabs should not less than (a) 0.12% of the gross area f concrete (b) 0.15% of the gross area of concrete (c) 0.18% of the gross area of concrete (d) 0.20% of the gross area of concrete

Last Answer : (b) 0.15% of the gross area of concrete

Description : The Minimum percentage of secondary steel in slabs for Fe- 415 grade steel should be __________ of Gross cross-section area [ A ] 0.12% [ B ] 0.15% [ C ] 0.20% [ D ] 0.25%

Last Answer : [ A ] 0.12%

Description : Which of the following statements is incorrect? (A) Minimum cross sectional area of longitudinal reinforcement in a column is 0.8% (B) Spacing of longitudinal bars measured along the periphery of ... (D) The number of longitudinal bars provided in a circular column should not be less than four

Last Answer : Answer: Option D

Description : Side face reinforcement shall not exceed [ A ] 0.1% of total cross sectional area [ B ] 0.2% of total cross sectional area [ C ] 0.1% web area [ D ] 0.2 % web area.

Last Answer : [ C ] 0.1% web area

Description : In R.C. sewer pipes, the percentage longitudinal reinforcement to the cross-sectional area of concrete is kept A. 10.0 B. 5.0 C. 2.0 D. 0.25

Last Answer : ANS: D

Description : Maximum percentage reinforcement in case of slabs is limited to (A) 2 (B) 4 (C) 6 (D) 8

Last Answer : (B) 4

Description : The most critical consideration in the design of a rolled steel column carrying axial loads is the (a) Percentage elongation at yield and the net cross-sectional area (b) Critical bending ... at ultimate load (d) Compressive strength based on slenderness ratio and gross cross-sectional area.

Last Answer : (d) Compressive strength based on slenderness ratio and gross cross-sectional area.

Description : The maximum area of tension reinforcement in beams shall not exceed (A) 0.15 % (B) 1.5 % (C) 4 % (D) 1 %

Last Answer : Answer: Option C

Description : As per IS : 456, the reinforcement in a column should not be less than (A) 0.5% and not more than 5% of cross-sectional area (B) 0.6% and not more than 6% of cross-sectional area (C) 0.7% and not more than 7% of cross-sectional area (D) 0.8% and not more than 8% of cross-sectional area

Last Answer : Answer: Option D

Description : Minimum percentage area of tension reinforcement , when the grade of steel is Fe-250 [ A ] 0.2 [ B ] 0.25 [ C ] 0.34 [ D ] 0.44

Last Answer : [ C ] 0.34

Description : The diameter of bars used for distribution reinforcement in slabs, may vary from (a) 2 to 4mm (b) 4 to 6mm (c) 6mm to 8mm (d) 8 to 12mm

Last Answer : (c) 6mm to 8mm

Description : The diameter of bars for main reinforcement in slabs, may be (a) 2 to 4mm (b) 4 to 8mm (c) 8 to 14mm (d) 14 to 18mm

Last Answer : (c) 8 to 14mm

Description : In slabs the Maximum horizontal distance between parallel main reinforcement should not exceed i.Three times effective depth ii Five times effective depth iii 300mm iv 450 mm [ A ] i and iii [ B ] i and iv [ C ] ii and iii [ D ] ii and iv

Last Answer : [ A ] i and iii

Description : The Maximum spacing of Secondary reinforcement in slabs should be [ A ] Less than 450 mm [ B ] Less than 300 mm [ C ] Smaller of three times the effective depth and 450 mm [ D ] Smaller of five times the effective depth and 450 mm

Last Answer : [ D ] Smaller of five times the effective depth and 450 mm

Description : The Maximum spacing of Main reinforcement „m‟ slabs shall be [ A ] Less than three times of the effective depth [ B ] Less than 300mm [ C ] Smaller of (a) and (b) [ D ] Greater of (a) and (b)

Last Answer : [ C ] Smaller of (a) and (b)

Description : If the permissible compressive and tensile stresses in a singly reinforced beam are 50 kg/cm2 and 1400 kg/cm2 respectively and the modular ratio is 18, the percentage area At of the steel required for an economic section, is (A) 0.496 % (B) 0.596 % (C) 0.696 % (D) 0.796 %

Last Answer : Answer: Option C

Description : Though agriculture contribute only 17.4 % to the country's gross value added for the year. 2016-17 A) 15.4% B) 17.4% C) 18.4% D) 20.4

Last Answer : 17.4%

Description : If the average compressive strength is 4000 kg/cm2 and standard deviation is 500, the co-efficient of variation is (A) 10 % (B) 12.5 % (C) 15 % (D) 18.5%

Last Answer : Answer: Option B

Description : For maximum strength and durability minimum percentage of cement, by weight is (A) 15 % (B) 20 % (C) 25 % (D) 30 %

Last Answer : Answer: Option D

Description : The area of the core of a column of cross sectional area A, is  (A) (1/3) A (B) (1/6) A (C) (1/12) A (D) (1/18) A

Last Answer : (D) (1/18) A

Description : The area of side face reinforcement shall not be less than [ A ] 0.10 percent of the web area on each vertical face [ B ] 0.05 percent of the web area on each vertical face [ C ] 0.15 percent of the web area on each vertical face [ D ] 0.20 percent of the web area

Last Answer : [ B ] 0.05 percent of the web area on each vertical face

Description : Which solid AWG wire size has the smallest physical cross-sectional area? A. 12 B. 14 C. 16 D. 18

Last Answer : Answer: D

Description : According to IS: 4561978, the maximum reinforcement in a column is (A) 2 % (B) 4 % (C) 6 % (D) 8 %

Last Answer : Answer: Option C

Description : The ratio of the effective length of a column and minimum radius of gyration of its cross-sectional area, is known (A) Buckling factor (B) Slenderness ratio (C) Crippling factor (D) None of these

Last Answer : (B) Slenderness ratio

Description : is the pre-stressed force applied to tendon of a rectangular pre-stressed beam whose area of cross section is and sectional modulus is . The minimum stress on the beam subjected to a maximum bending moment is (A) f = (P/A) - (Z/M) (B) f = (A/P) - (M/Z) (C) f = (P/A) - (M/Z) (D) f = (P/A) - (M/6Z)

Last Answer : Answer: Option C

Description : channel is said to be of most economical cross-section, if (A) It gives maximum discharge for a given cross-sectional area and bed slope (B) It has minimum wetted perimeter (C) It involves lesser excavation for the designed amount of discharge (D) All of the above

Last Answer : Answer: Option D

Description : Vertical construction joints are provided where the shearing forces are minimum in the case of (A) Slabs (B) Beams (C) Girders (D) All of these

Last Answer : Answer: Option D

Description : Minimum steel required in slabs is mainly controlled by the following consideration [ A ] Cracking on the tension side [ B ] Shrinkage and creep [ C ] Both (a) and (b) [ D ] None of the above.

Last Answer : [ B ] Shrinkage and creep

Description : For determining the moisture content of a soil sample, the following data is available Weight of container = 260 g, Weight of soil sample and = 320 g container, Weight of soil sample (dried) and = 310 g container. The moisture content of the soil sample, is (A) 15 % (B) 18 % (C) 20 % (D) 25 %

Last Answer : (C) 20 %

Description : The limits of percentage p of the longitudinal reinforcement in a column is given by (A) 0.15% to 2% (B) 0.8% to 4% (C) 0.8% to 6% (D) 0.8% to 8%

Last Answer : Answer: Option C

Description : Super-elevation on roads in snow bound areas, should generally not exceed (A) 15 % (B) 12 % (C) 10 % (D) 7 %

Last Answer : Answer: Option D

Description : If the depth of moist sand in a cylinder is 15 cm and the depth of the sand when fully inundated with water is 12 cm, the bulking of the moist sand, is (A) 10 % (B) 12 % (C) 15 % (D) 25%

Last Answer : Answer: Option D

Description : The moisture content in a well seasoned timber is (A) 4 % to 6 % (B) 10 % to 12 % (C) 15 % to 20 % (D) 100 %

Last Answer : Answer: Option B

Description : If a concrete column 200 200 mm in cross-section is reinforced with four steel bars of 1200  mm2  total cross-sectional area. Calculate the safe load for the column if permissible stress in  concrete is 5 N/mm2 ... 15 Ec (A) 264 MN  (B) 274 MN  (C) 284 MN  (D) 294 MN 

Last Answer : (C) 284 MN 

Description : The minimum strain at failure in the tensile reinforcement (Fy = 400 MPa) of RCC beam as per limit state method is (a) 0.0020 (b) 0.0028 (c) 0.0037 (d) 0.0045

Last Answer : (c) 0.0037

Description : A soil has a bulk density of 22 kN/m3 and water content 10 %. The dry density of soil is (A) 18.6 kN/m3 (B) 20.0 kN/m3 (C) 22.0 kN/m3 (D) 23.2 kN/m3

Last Answer : (B) 20.0 kN/m3

Description : The length of lap in tension reinforcement should not be less than the bar diameter × (actual tension / four times the permissible average bond stress) if it is more than (A) 18 bar diameters (B) 24 bar diameters (C) 30 bar diameters (D) 36 bar diameters

Last Answer : Answer: Option C

Description : Lapped splices in tensile reinforcement are generally not used for bars of size larger than (A) 18 mm diameter (B) 24 mm diameter (C) 30 mm diameter (D) 36 mm diameter

Last Answer : Answer: Option D

Description : _______ designates the shape of gross peripheral and cross-sectional boundaries of the soil working tool a) Micro shape c) Edge shape b) Macro shape d) Gross shape

Last Answer : c) Edge shape

Description : For 3.25 × 10-2 cumecs discharging from a well, a pump is installed to lift water against a total head  of 30 m. The minimum required horse power, is  (A) 10 H.P.  (B) 15 H.P.  (C) 18 H.P.  (D) 20 H.P. 

Last Answer : (D) 20 H.P. 

Description : If the diameter of the main reinforcement in a slab is 16 mm, the concrete cover to main bars is (A) 10 mm (B) 12 mm (C) 14 mm (D) 16 mm

Last Answer : Answer: Option D

Description : A reinforced concrete slab is 75 mm thick. The maximum size of reinforcement bar that can be used is (a) 6 mm diameter (b) 8 mm diameter (c) 10 mm diameter (d) 12 mm diameter

Last Answer : (b) 8 mm diameter

Description : The main reinforcement of a R.C. slab consists of 10 mm bars at 100 mm spacing; if it is desired to replace the 10 mm bars by 12 mm bars, then the spacing of 12mm bars should be (a) 120 mm (b) 140 mm (c ) 144 mm (d) 160mm

Last Answer : (c ) 144 mm

Description : The minimum percentage of silica, alumina and ferric oxide in lime for white washing, is (A) 20 (B) 15 (C) 5 (D) 0

Last Answer : Answer: Option D

Description : A jet of water of cross-sectional area 20 sq. cm impinges on a plate at an angle of 60? with a velocity of 10 m/sec. Neglecting the friction between the jet and plate (density of water 1000/9.81 kgm-1 sec2 per cubic meter), the ... a.15 - 20 kg b.20 - 25 kg c.5 - 10 kg d.25 - 30 kg e.10 - 15 kg

Last Answer : a. 15 - 20 kg