Explain the need of level measurement.

1 Answer

Answer :

Need of level measurement: In almost all industries, vast quantities of liquids such as water, solvents, chemicals etc. are used in number of processes. Liquid level measurements are widely employed to monitor as well as measure quantitatively the liquid content in the tanks, containers, vessels, reservoirs or liquid columns. The liquid level affects both pressure and rate of flow in and out of the container and therefore its measurement/ control becomes important in maintaining the overall process conditions. Hence improved level measurement accuracy makes it possible to reduce chemical process variability, resulting in higher product quality, reduced cost, and less waste.

Related questions

Description : Draw and explain the working principle of ultrasonic level measurement system. Also give advantages, disadvantages and applications of it.

Last Answer : Ultrasonic level detectors operate either by the absorption of acoustic energy as it travels from source to receiver or by the attenuation (frequency change) of a vibrating diaphragm face, oscillating at ... without making physical contact with the process material. 2. They have no moving parts.

Description : With neat diagram, explain working of capacitance level measurement.

Last Answer : working : The capacitive level detector operates on the equation of parallel plate capacitor, i.e. C = ε A/d. It consist of an insulated capacitance probe (which is a metal electrode) ... in the capacitance is measured and is displayed on the indicator calibrated in terms of liquid level. 

Description : What is need of level measurement? Give classification of level measurement methods with two examples of each.

Last Answer : In almost all industries, vast quantities of liquid such as water solvents, chemicals etc. are used in number of processes. It is widely employed to monitor as well as measure quantitatively the ... a) Capacitance level indicator b) Radiation level detector c) Ultrasonic level gauge 3. Radar type

Description : Describe the resistive method for liquid level measurement. Write its advantages and disadvantages.

Last Answer : Working: This method uses mercury as a conductor as shown in the figure. A number of contact rods are placed at various liquid levels. As the level of liquid rises in the tank, head h ... connected in series is calibrated in terms of the liquid level and indicates the liquid level directly. 

Description : List advantages and disadvantages of Radiation type level measurement method. 

Last Answer : Advantages : 1. Quite suitable for large reservoirs of 30-40 m diameter. 2. Continuous measurement is possible. 3. Non-contact device. 4. Measurement is independent on temperature, ... method due to radiation effects. 2. Adequate shielding is required to limit the radiation field intensity

Description : Write two advantages and applications of ultrasonic level measurement.

Last Answer : i) It is used for measurement of hazardous fluid level. ii) It is used for measurement of liquid or solid material level of tanks used by dairies, chemical plants, mineral companies. iii) It is used ... V) It is used for measurement of sand, crushed rock, and gravel level in gravel open-cast mines.

Description : State two advantages and two disadvantages of radiation type level measurement.

Last Answer : Advantages: 1. Quite suitable for large reservoirs of 30-40 m diameter. 2. Continuous measurement is possible. 3. Non-contact device. 4. Measurement is independent on temperature, pressure, ... due to radiation effects. 2. Adequate shielding is required to limit the radiation field intensity

Description : Draw a diagram of radar level measurement. Write an advantage and disadvantage of it.

Last Answer : Advantages:  • This is non contact method  • High accuracy for measurements in storage tanks and process vessels Disadvantages:  • Expensive technology  • Reading is affected by change in density of liquid

Description : Explain differential pressure measurement method as indirect method for level measurement.

Last Answer : Differential pressure measurement as indirect method for level measurement:  Closed vessel: Differential pressure (DP) transmitters used for liquid level application measure hydrostatic pressure head. In a closed ... side of the DP and the low pressure side is vented to atmosphere.  

Description : Explain the capacitance type level measurement method with neat diagram.

Last Answer : Capacitance level indicator  Explanation: It consists of two conductors separated from each other by dielectric material between them. There is an insulated capacitance probe fixed near and parallel to ... , the dielectric constant changes due to which capacitance changes. Thus any change.

Description : Explain with principle the instrument for air purge method of level measurement.

Last Answer : Air purge method for of level measurement:  Principle: When liquid is held in a tank, then it exerts equal pressure on the walls of the tank. Such a pressure is due to the weight ... the hydrostatic pressure. The gauge then measures the air pressure needed to overcome the pressure of the liquid.

Description : List any two direct methods of level measurement. Explain Hydrostatic method of level measurement. Give one advantage and one disadvantage of it.

Last Answer : ➢ Direct methods of level measurement Direct methods 1. Hook type 2. Sight glass type 3. Float type 4. Dip stick ➢ Hydrostatic method of level measurement. ➢ A liquid in ... - 1. Their calibration gets changed according to variations in product density. 2. Require compressed air.

Description : Explain calibration of capacitive type level measurement.

Last Answer : ➢ Calibration of capacitance type level transmitter 1. Remove the level transmitter from the system(tank). 2. check whether transmitter shows zero reading by connecting with multimeter otherwise release the ... rotate the span screw to 20ma. 3. Repeat these steps and check all readings

Description : State need of level measurement.

Last Answer : In almost all industries, vast quantities of liquid such as water solvents, chemicals etc. are used in number of processes. It is widely employed to monitor as well as measure ... and therefore its measurement becomes important in a variety of processes encountered in modern manufacturing plants.

Description : Draw and explain the circuit diagram for measurement of single phase power using dynamometer type wattmeter. 

Last Answer : Circuit diagram for measurement of single phase power using dynamometer type wattmeter: Explanation: It consists of two stationary coils, called current coils and one moving coil, called voltage or ... i.e. power. The meter can be calibrated directly to indicate the power in watts. 

Description : Explain the working of diaphragm for pressure measurement. 

Last Answer : Capacitive transducers are used for the measurement of pressure by converting the pressure into a displacement. The displacement is sensed by a capacitive transducer using a differential arrangement's ... shows a 1800 phase shift. This voltage may be amplified by an emitter follower amplifier.

Description : Draw and explain the measurement of torque using Torque Cell

Last Answer : Figure a shows the construction of load cell used to measure torque using strain gauges connected to the rotating shaft.. Figure b represents the bridge arrangement to measure torque. .The ... diagonal axis. The Wheatstone bridge output is proportional to torsion and hence the torque. . 

Description : Draw and explain in brief speed measurement using non-contact type transducer. 

Last Answer :  i) Photoelectric Tachometer:  This method of measuring speed consists of mounting an opaque disc on the rotating shaft. The disc has a number of equidistant holes on its periphery. At one side of the disc a light source is ... (pulses per second /number of teeth)  = (P/T) rps = (P/T) *60 rpm.

Description : What is encoder? Draw and explain an optical encoder operation for rotary motion measurement.

Last Answer : Definition: Digital encoders convert analog motion (rotary or linear) to a digital output form. An optical encoder is an electromechanical device which has an electrical output in digital form proportional to ... . In this way a train of pulses equivalent to the rotation is obtained as shown.

Description : Draw and explain the displacement measurement system using LVDT.

Last Answer : (Or)  LVDT has a single primary winding P and two secondary windings S1 and S2 wound on a cylindrical former. S1 and S2 have equal number of turns and are ... while simultaneously reducing the voltage in the other winding. Output voltage Vo measured is equivalent to the displacement.

Description : Draw and explain force or weight measurement using load cell. 

Last Answer : Description: Load cells utilize an elastic member as the primary transducer and strain gauges as secondary transducers. Strain gauges may be attached to any elastic member, on which there exists ... across the four arm Wheatstone bridge circuit, is a measure of the weight being applied.

Description : Draw and explain temperature measurement using RTD. State its advantages and disadvantages.

Last Answer : https://youtu.be/rYcglFW4y0I

Description : How strain gauge is used for pressure measurement, explain?

Last Answer : strain gauge: - strain gauge is used for pressure measurement as one of the arm of a wheatstones' bridge, the pressure is applied to the strain gauge through diaphragm elastic pressure sensor.

Description : Explain significance and purpose of electrical measurement system.

Last Answer : ➢ Significance of Electrical Measurement System  1. The measurement is required for measurement of all physical quantities for e.g speed, velocity, temperature, pressure etc.  2. All electrical ... 4. These standards and references may changes time to time, area to area person to person 

Description : Explain V- I method of measurement of medium resistance. 

Last Answer : In this method, use suitable source, ammeter and voltmeter and connect them as shown in the above diagram. Take reading of voltmeter and ammeter, then value of resistance = R = V/I Ω To minimise the error take 4 to 5 observation for the same resistance and take their average.

Description : What level of measurement is ethnicity?

Last Answer : It is nominal.

Description : What Blood alcohol concentration is a measurement of the level of alcohol in the bloodstream and is shown in milligrams of alcohol per how many milliliters of blood?

Last Answer : Need answer

Description : What is the reference level for noise measurement, F1A weighted? A. -90 dBm B. -82 dBm C. -67 dBm D. -85 dBm

Last Answer : D. -85 dBm

Description : A microarray differs from a gene fusion in that, it A- carries DNA segments from many different genes B- is not constructed by cloning C- gives direct measurement of mRNA level D- all of the above

Last Answer : all of the above

Description : Most of the outcome/dependent variable characteristics and attributes measured on educational characteristics probably exist at the ______________ level of measurement. a. Nominal b. Ordinal c. Interval d. Ratio

Last Answer : b. Ordinal

Description : A study in which we see the nurse’s level of education is classified in which level of measurement? a. Nominal-scale b. Ordinal scale c. Interval scale d. Ratio-scale

Last Answer : b. Ordinal scale

Description : Theodolite is an instrument used for (a) Tightening the capstan-headed nuts of level tube (b) Measurement of horizontal angles only (c) Measurement of vertical angles only (d) Measurement of both horizontal and vertical angles*

Last Answer : (d) Measurement of both horizontal and vertical angles*

Description : List any two non-contact type level measurement methods.

Last Answer : • The following are non-contact type level measurement methods 1. Ultrasonic type level measurement 2. Nuclear radiation type level measurement 3. Radar type level measurement 4. Capacitive level transducer. 5. Load cell type level transducer.

Description : List any two advantages and applications of RADAR type level measurement.

Last Answer : ➢ Advantages: - 1. This is non-contact technology, 2. High accuracy for measurements in storage tanks and some process vessels. 3. Used on difficult hard-to-handle' applications 4. High accuracy 5. ... 6. Powders 7. Bulk solids 8. Ice cream "Premix" mixer 9. Storage tanks for toxic liquids

Description : Compare Nuclear Radiation type and Ultrasonic level measurement.

Last Answer : Sr. No Nuclear Radiation Ultrasonic level  1 Can be installed in highly hazardous areas   Cannot be installed in highly hazardous areas 2 They can measure level in applications ... 7 Measurements can be skewed by density Measurements cannot be skewed by density

Description : Give classification of level measurement methods.

Last Answer : Classification of Liquid Level Measurement: ➢ Direct method 1. Hook type 2. Sight glass type 3. Float type 4. Dip stick ➢ Indirect method 1. Hydrostatic pressure type 2. Electrical type: a) Capacitance level indicator b) Radiation level detector c) Ultrasonic level gauge 3. Radar type

Description : Describe working principle of radiation level measurement with neat diagram.

Last Answer : Radiation type level measurement. Is non contact type detector which is used where electrical method would not survive. working principle 1.It consist of gamma ray source holder on one side ... 7. Thus, when liquid level rises, the amount of radiation received is reduced and vice versa.

Description : List the different level measurement methods. 

Last Answer : Liquid Level Measurement Direct method 1. Hook type 2. Sight glass gype 3. Float type 4. Dip stick Indirect method 1. Hydraustatic pressure type 2. Electrical type a) Capacitance level indicator b) Radiation level detector c) Ultrasonic level gauge 3. Radar type