State any four relays used for catenary protection. State function of each relay.

1 Answer

Answer :

Relays Used for Catenary Protection: 1. MHO relay: Wrong coupling protection. 2. MHO relay: Over current protection at farthest point. 3. Over current relay: Over current protection against faults near substation 4. Under voltage relay: Protection against faults far away from substation. 

Related questions

Description : Give protection scheme used for 25kV catenary protection for AC traction.

Last Answer : Protection Scheme Used for 25kV Catenary Protection for AC Traction: As shown in the figure below the scheme consists of 1) MHO relay that makes use of the impedance phase angle to get proper ... adjustment. 2) Over current relay. 3) Under voltage relay for low voltage protection.

Description : State use of any four relays for the protection of traction transformer. 

Last Answer : Relays for the protection of traction transformers:  Inverse time over current relay as back up protection on primary (HV side) - over current protection of transformer and other equipment.  ... .  Buchholz relay - protection from incipient earth or inter winding faults inside the transformer

Description : As shown in the illustration, when the 'speed control' system is in 'SPLIT' _______________. EL-0096 A. Relays #1, #5 and #8 are not used B. the 'slew rated controller' is grounded through Relay ... E/P converters' are bypassed and air is fed directly to the governors via the 'load sharing valve'

Last Answer : Answer: C

Description : Power necessary to operate the horn relay shown in the illustration ____________. EL-0093 A. comes from each station's magneto B. is supplied from a 115 volt source C. is conducted through the relay's contacts D. also lights lamps 'R' and 'T'

Last Answer : Answer: A

Description : Explain with neat sketch overload protection for power circuit of locomotive.

Last Answer : Overload Protection for Power Circuit of Locomotive:  1. To protect the main power circuit from overload, the thermal overload relays are used. 2. The overload is sensed by the ... overload relay OLR3 operates for overload fault on traction motor due to the flashover of traction motors. 

Description : Explain protection of locomotive from overvoltage and under voltage

Last Answer : Protection of Locomotive From Overvoltage and Under Voltage: 1. For protection against over voltages the over voltage relay which is basically a potential transformer (PT) is used. 2. ... a relay triggering an alarm, which enables the power controller to react and take corrective measures.

Description : Explain the surge protection of electric locomotive from i) Direct lightening stroke ii) Switching surges

Last Answer : i)Protection of Electric Locomotive From Direct Lightening Stroke:  1. The direct lightning strokes may strike on the overhead conductor on the roof of the locomotive. 2. To protect the ... reduce the steepness of the wave front and also help to absorb the energy in the resistance.

Description : List any four current collectors for overhead system. State application of each.

Last Answer : Current Collectors for Overhead System With Their Application: 1. Trolley (Pole) collector: It is used for trolley buses having speed range from 20kmph to 32kmph. 2. Cable collector: This ... used for main line service locomotives, urban trains, suburban trains etc. having higher speed range.

Description : Which of the following statements represents the main difference between a relay and a contactor? A. Contactors control current and relays control voltage. B. A relay is series connected and a contactor ... loads than relays. D. Contactors are made from silver and relays are made from copper.

Last Answer : Answer: C

Description : Which of the following relays is used on long transmission lines ? (a) Impedance relay (b) Mho's relay (c) Reactance relay (d) None of the above

Last Answer : (b) Mho's relay

Description : Define the following terms with respect to protective relays i) Relay time ii) Reset current iii) Plug setting multiplier and iv) Time setting multiplier

Last Answer : 1) Relay Time: The time interval between occurrence of fault and closure of relay contacts.  2) Reset Current: The value of current below which the relay resets and comes back to ... The adjustment arrangement provided for setting the operation time of relay is known as Time setting multiplier. 

Description : State four important features of LEM that differ it from normal electric motor. 

Last Answer : Important Features of LEM That Differ it From Normal Electric Motor: 1. In LEM, primary & secondary or stator & rotor have longitudinal arrangement while normal electric motor has circular ... in high speed levitated system while normal electric motor is used for rotary mechanical output.

Description : Draw a neat sketch of earth fault protection of auxiliary circuit of electric loco. State the function of relay and isolating resistance.

Last Answer : Ans: Earth fault protection for auxiliaries in Loco: Function of relay: The earth fault occurring anywhere in the auxiliary circuit gets monitored by the relay which acts to trip the main CB. Function of ... star point to earth through a high resistance so that the relay operation is avoided.

Description : What are the different relays that employed for protection of apparatus and transmission lines?

Last Answer : Answer: The relays that are usually employed for protection of transmission lines include • Over current relay • Directional relay • Distance relay • Under Voltage relay • Under-frequency relay • Thermal relay • Differential relay • Phase sequence relays • pilot relays

Description : The inverse definite mean time relays are used for over current and earth fault protection of transformer against (a) heavy loads (b) internal short-circuits (c) external short-circuits (d) all of the above

Last Answer : (b) internal short-circuits

Description : The single phasing relays are used for the protection of (a) single phase motors only (b) two phase motors only (c) two single phase motors running in parallel (d) three phase motors

Last Answer : (d) three phase motors

Description : Discrimination between main and back up protection is provided by the use of relays which are (a) fact (b) sensitive (c) slow (d) none of the above

Last Answer : (c) slow

Description : Large internal faults are protected by (a) merz price percentage differential protection (b) mho and ohm relays (c) horn gaps and temperature relays (d) earth fault and positive sequence relays

Last Answer : (a) merz price percentage differential protection

Description :  For the protection of parallel feeders fed from one end, the relays used are: A) non-directional relays at the source-end and directional relays at the load-end B) non-directional relays at both the ... at the source-end and non-directional at the load-end D) directional relays at both the ends

Last Answer : For the protection of parallel feeders fed from one end, the relays used are: non-directional relays at the source-end and directional relays at the load-end

Last Answer : The inverse definite mean time relays are used for over current and earth fault protection of transformer against internal short-circuits.

Last Answer : The single phasing relays are used for the protection of three phase motors.

Last Answer : Discrimination between main and back up protection is provided by the use of relays which are slow.

Description : List different types of signals. State application of each.

Last Answer : Different Types of Signals: 1) Flag signals: This is shown by signalman if green flag is raised; it means to proceed with caution. Green flag shown down, it means there is track defect; ... green lamps indicate indications as in the 2-aspect system, and the yellow lamp shows the caution indication.

Description : Give any four advantages of voice frequency signaling over DC signaling system. 

Last Answer : Advantages of Voice Frequency Signaling Over DC Signaling System: 1. Large number of circuits can be easily derived over a single pair of wires (single pair can control 18 stations). 2. Signal ... used over long distances. 5. Can be used where large number of equipment can be controlled. 

Description : List any four weaknesses of LIM propelled railway traction system.

Last Answer : Weaknesses of LIM Propelled Railway Traction System: 1. The system requires looping of all reaction rails all along the route. This considerably adds to the cost of track. 2. Since Al is relative ... in the magnetic and electric circuits at entry and exit ends of motor, poor motor efficiency.

Description : Give any four advantages of remote control system.

Last Answer : Advantages of remote control system: 1. As substations and control posts are unattended (due to remote controls) there is considerable savings due to less manpower. 2. Central control station ... Switching operations are carried out safely, quickly, and economically. 6. Maintenance cost is low.

Description : The shape of a suspended cable under its own weight is a.Catenary b.Elliptical c.Cycloidal d.Semi-circle e.Parabolic

Last Answer : a. Catenary

Description : The curve of a catenary by nature is a.hyperbolic b.ellipse c.107 dynes d.circular e.parabolic

Last Answer : e. parabolic

Description : What do you understand by catenary cable ?

Last Answer : A cable attached to the supports and carrying its own weight.

Description : If a constant section beam is subjected to a uniform bending moment throughout, its length bends  to  (A) A circular arc  (B) A parabolic arc  (C) A catenary  (D) None of these 

Last Answer : (A) A circular arc 

Description : A heavy string attached at two ends at same horizontal level and when central dip is very small approaches the following curve (A) Catenary (B) Parabola (C) Hyperbola (D) Elliptical

Last Answer : (B) Parabola

Description : A conductor, due to sag between two supports, takes the form of (a) semi-circle (b) triangle (c) ellipse (d) catenary

Last Answer : (d) catenary

Description : State the classification of locomotive.

Last Answer : Classification of Locomotive:  A) Based on the types of service rendered:  1. Freight service for transportation of goods only.  2. Passenger service for transportation of passengers.  3. Mixed traffic ... the type of supply used:  1. Alternating current (AC)  2. Direct current (DC)

Description : The purpose of a magnetic relay is to _____________. A. open a circuit only in the event of overload B. remotely open and close contacts C. provide overcurrent protection during starting D. relay voltages at increased power

Last Answer : Answer: B

Description : Protection against sustained overloads occurring in molded-case circuit breakers is provided by a/an __________. A. overvoltage release B. thermal acting trip C. thermal overload relay D. current overload relay

Last Answer : Answer: B

Description : A series resistance is added to the over-current relay in a bus bar differential protection scheme which: a. Helps to develop some voltage across it which otherwise should appear across the relay and is ... the effects of CT saturation and lowers the pickup value of the relay d. All of the above 

Last Answer : A series resistance is added to the over-current relay in a bus bar differential protection scheme which: a. Helps to develop some voltage across it which otherwise should appear across the relay and is ... the effects of CT saturation and lowers the pickup value of the relay d. All of the above 

Description : The transmission line distance protection relay having the property of being inherently directional is (A) impedance relay (B) MHO relay (C) OHM relay (D) reactance relay

Last Answer : The transmission line distance protection relay having the property of being inherently directional is MHO relay

Description : A relay used for protection of motors against overload is :  (A) Impedance relay (B) Electromagnetic attraction type (C) Thermal relay (D) Buchholz's relay

Last Answer : D

Description : A negative sequence relay is used for protection of  (1) Generator (3) Motor (2) Transformer (4) Long Transmission lines

Last Answer : A negative sequence relay is used for protection of Generator 

Description : Reactance relay is normally preferred for protection against

Last Answer : Reactance relay is normally preferred for protection against earth faults

Description :  Mho relay is usually employed for protection of (A) Short lines (B) Medium lines (C) Long lines (D) Any line

Last Answer : Mho relay is usually employed for protection of long lines.

Last Answer : Buchholz's relay gives warning and protection against electrical fault inside the transformer itself.

Description : Explain with neat diagram i) Sectioning and paralleling post ii) Sub sectioning post

Last Answer : i) Sectioning and Paralleling Post: Explanation of Sectioning and Paralleling Post: 1. The power supply arrangement is as shown in above figure for two track lines between feeding posts and ... subsection or the other. 4. There is no interrupter for paralleling the up and down track line

Description : Write down the circuit breaker with their rating used in traction substation. Explain any one.

Last Answer : Circuit Breaker With Their Rating Used in Traction Substation: Rated capacity of a circuit breaker is 750Amps at 25 kV, 500MVA. Its overall tripping time is 0.14 seconds composed of 0.04 ... but in case of traction substation application, mostly Minimum Oil Circuit Breaker (MOCB) is preferred.

Description : Explain with neat diagram trolley collector for overhead system

Last Answer : Trolley Collector for Overhead System:  This consists of a grooved gun metal wheel or grooved slider shoe with carbon insert carried attached to the end of a long pole provided on the top of ... gives rise to high current density. Suitable for comparative low speed (say 22 to 30 kmph).

Description : Draw and explain in brief construction of Diamond Pantograph. Write one advantage and one disadvantage of it.

Last Answer : Diamond Pantograph: Construction of Diamond Pantograph: 1)Diamond Pantograph consist of pressed steel channel sectional fitted with renewable collector strips and supported at the apex of Pentagonal ... It requires more maintenance than Faiveley type. 4. It is costlier than Faiveley type.

Description : With neat sketch explain automatic weight tension and temperature compensation.

Last Answer : Automatic Weight Tension and Temperature Compensation: The tension in overhead lines in traction systems depends on the temperature. Higher temperatures lead to expansion of conductors and hence sag. It is therefore ... figure. The tension in the contact wire and catenary is around 1000 kg.

Description : Explain the following - 1) Encumbrance 2) Span length.

Last Answer : Encumbrance: It is the axial distance between catenary and contact wire. Its value is maintained at 1.4 m as per rules except at i) Turn outs, ii) Overlaps iii) In the vicinity of over ... depends various factors like: i) Wind pressure ii) Curvatures iii) Current collection point of view etc.

Description : Give the purpose and location of neutral section and section insulator. 

Last Answer : Purpose of Neutral section: Passing of pantograph under insulated overlap will cause short circuit between two phases, damaging OHE & pantograph. To avoid this bridging, a neutral section is inserted between them ... Location: Located at cross over from one track to other, from main line to siding.

Description : A faulty 'function generator' shown in the illustration may prevent _____________. EL-0095 A. proper pitch control from both the 'bridge' and 'engine room thrust levers' B. the 'split potentiometer ... control pitch C. the pitch meter from indicating accurately D. relays #2 and/or #3 from energizing

Last Answer : Answer: A