What are the types of distribution system?

1 Answer

Answer :

a. Radial distribution system.
b. Ring distribution system.
c. Grid distribution system.

Related questions

Description : What are types of distribution of supply?

Last Answer : a. Over head distribution system. b. Under ground distribution system.

Description : Which of the following busbar arrangement is generally employed in distribution system: a) One-and-half breaker arrangement b) Main and transfer arrangement c) Ring main distribution system d) Single busbar arrangement system

Last Answer : Ans: C

Description : Which distribution system is more reliable? (a) Ring main system (b) Tree system (c) Radial system (d) All are equally reliable

Last Answer : Ans: A

Description : Which of the following is/are true concerning electric power operated watertight door systems? A. Each motor driven door must use the main bus as its source of power. B. Each distribution panel for ... to permit quick activation of the system. D. Each system must have a separate branch circuit.

Last Answer : Answer: D

Description : If the total source voltage of the three-wire distribution system shown in the illustration is 240 volts, what is the voltage across load L5? [ NOTE: Kirchhoff's voltage and current laws apply ] EL-0075 A. 110.4 volts B. 112.2 volts C. 113.0 volts D. 114.8 volts

Last Answer : Answer: D

Description : A ground on a particular phase of a three-phase low voltage distribution system would be indicated by a _____________. A. high switchboard wattmeter reading B. low switchboard wattmeter reading C. dark or dim switchboard ground detecting light D. bright switchboard ground detecting light

Last Answer : Answer: C

Description : A ground is indicated by the ground-detecting system on the main electrical switchboard. The FIRST step in locating the actual ground is to _____________. A. close all circuit breakers in ... ground detection system indicates normal C. change over generators D. check each circuit with a megohmmeter

Last Answer : Answer: B

Description : A flickering ground detection lamp on a DC system would indicate a _____________. A. multiple-ground condition in the distribution system B. ground in an armature coil of an operating machine C. ground in a motor accompanied with a short D. short between two adjacent bars of the generator commutator

Last Answer : Answer: B

Description : If the total source voltage of the three-wire distribution system shown in the illustration is 240 volts, what is the voltage across load L1? [NOTE: Kirchhoff's voltage and current laws apply.] EL-0075 A. 110.4 volts B. 112.2 volts C. 113.3 volts D. 114.8 volts

Last Answer : Answer: D

Description : If the total source voltage of the three-wire distribution system shown in the illustration is 240 volts, what is the voltage across load L2? [NOTE: Kirchhoff's voltage and current laws apply.] EL-0075 A. 110.4 volts B. 112.2 volts C. 113.0 volts D. 114.8 volts

Last Answer : Answer: C

Description : If the total source voltage of the three-wire distribution system shown in the illustration is 240 volts, what is the voltage across load L3? [NOTE: Kirchhoff's voltage and current laws apply.] EL-0075 A. 110.4 volts B. 112.2 volts C. 113.0 volts D. 114.8 volts

Last Answer : Answer: B

Description : If the total source voltage of the three-wire distribution system shown in the illustration is 240 volts, what is the voltage across load L4? EL-0075 A. 110.4 volts B. 112.2 volts C. 113.0 volts D. 114.8 volts

Last Answer : Answer: A

Description : Which of the following represents a characteristic of an ungrounded electrical distribution system? A. Accidental contact between one line and ground does not cause an outage. B. Double ground faults on ... unnecessary. D. Accidental contact between one line and ground will always cause an outage.

Last Answer : Answer: A

Description : If the illustrated motor fails to start and gives a loud hum when the start button is pushed, the problem is ________. EL-0007 A. one of the phases to the motor is not energized because of ... electrical distribution system D. 'OL1' is open because of 'T1' overload causing the motor to single phase

Last Answer : Answer: A

Description : A switchboard, for a AC electrical distribution system, will be provided with which of the following components? A. Frequency meter. B. Ammeter C. Voltmeter D. All of the above

Last Answer : Answer: D

Description : The part of the shipboard electrical system used to control the distribution of power to the branch circuits, is the _____________. A. bridge control panel B. disconnect links C. governor relay box D. main switchboard

Last Answer : Answer: D

Description : How harmonics generated in electrical power distribution system?

Last Answer : Harmonic frequencies are integral multiples of the fundamental supply frequency, i.e. for a fundamental of 50 Hz, the third harmonic would be 150 Hz and the fifth harmonic would be 250 ... the corresponding application guides, since the electricity grid's protection system should cut off the fault.

Description : What are the main items used in over head distribution system?

Last Answer : a. Conductor material. b. Pole. c. Cross arm. d. Insulators. e. Strain insulator. f. Post insulator. g. Stay wire. h. Support with insulator and stay lightner.

Description : The purpose of the automatic bus transfer shown in the illustration is to ___________. EL-0014 A. stepdown voltage to the lighting distribution panel B. provide emergency power to ... emergency switchboard from the main switchboard D. provide overcurrent protection to the lighting distribution panel

Last Answer : Answer: B

Description : In the lighting distribution circuit shown in the illustration, if all switches are closed and fuse 'F2' were to open, all lights on branches ____________. EL-0013 A. '1', '2', and '3' would go out B. '1' ... and '3' would burn dimly D. '1' and '3' would go out, while branch '2' would remain lit

Last Answer : Answer: D

Description : If the illustrated lighting branch distribution box is not for cargo or deck lighting, the Coast Guard Regulations (46 CFR) requires the designed load attached to Branch NO.2 to be no more than _________. EL-0013 A. 5 amps B. 16 amps C. 30 amps D. 50 amps

Last Answer : Answer: B

Description : Capacitors can be used in electric distribution systems to improve power factor. This is accomplished by seesawing energy between the capacitor and the _____________. A. generator B. inductive loads C. resistive loads D. all of the above

Last Answer : Answer: B

Description : When shipboard electrical distribution circuits are connected in parallel, additional parallel circuits will cause the total circuit resistance to _____________. A. increase, causing a drop in the line current B ... an increase in the line voltage D. decrease, causing an increase in the line current

Last Answer : Answer: D

Description : Line losses in a distribution circuit are kept to a minimum by __________. A. adding rubber insulation conductors to the circuit B. using higher current and lower voltage C. increasing the number of thermal relays in the circuit D. using higher voltage and lower current

Last Answer : Answer: D

Description : The heating of conductors as a result of resistance in a distribution circuit causes a power loss expressed as _____________. A. line droop B. line loss C. IR drop D. hysteresis

Last Answer : Answer: B

Description : For distribution network which type of Switching scheme is employed?

Last Answer : For distribution network Ring Main busbar scheme is employed. It has the provision that if power interruption occurs to one bus section due to maintenance or fault, power can be fed the bus from other side of the power system.

Description : Where should the lighting arrestor is placed in distribution lines?

Last Answer : Near distribution transformers and out going feeders of 11kv and incoming feeder of 33kv and near power transformers in sub-stations.

Description : What will happen when power factor is leading in distribution of power?

Last Answer : If there is high power factor, i.e. if the power factor is close to one: 1. Losses in form of heat will be reduced, 2. Cable becomes less bulky and easy to carry, and very cheap to afford, & 3. It also reduces over heating of transformers.

Description : At what power maximum efficiency of power transformer and distribution transformer is designed

Last Answer : Maximum efficiency of the transformer is attained at certain load factor (α) when core losses of transformer is equal to the copper losses. PCore loss = α ^2 X PCopper loss From the ... the day. Hence distribution transformers are designed to have maximum efficiency at 50% of the rated full load

Description : What Will Happen When Power Factor Is Leading In Distribution Of Power?

Last Answer : If their is high power factor, i.e if the power factor is close to one: losses in form of heat will be reduced, cable becomes less bulky and easy to carry, and very cheap to afford, & it also reduces over heating of tranformers.

Description : Where should the lighting arrestor be placed in distribution lines?

Last Answer : A:Near distribution transformers and out going feeders of 11kv and incomming feeder of 33kv and near power transformers in sub-stations.

Description : What will happen when power factor is leading in distribution of power?

Last Answer : A:If their is high power factor, i.e if the power factor is close to one: 1.losses in form of heat will be reduced, 2.cable becomes less bulky and easy to carry, and very cheap to afford, & 3. it also reduces over heating of transformers.

Description : Write down the formula for distribution factor

Last Answer : Kd = sin (mβ/2) / msin(β/2) where m - number of slots/pole/phase Slot angle β - angle between adjacent slots in electrical degree =180/(slots/pole)

Description : Define distribution factor or winding factor or breadth factor or spread factor

Last Answer : The distribution factor is defined as the ratio of vector sum to arithmetic sum of emf induced in the conductor of one phase spread. OR It is ratio of resultant emf induced when coils are distributed to the resultant emf induced when coils are concentrated.

Description : What is the vector group of distribution transformer?

Last Answer : Dy11

Description : Which type of connection is used in distribution transformer?

Last Answer : Distribution transformers are connected in delta-star. This arrangement requires 3 conductors in the high voltage side and 4 in the low voltage side, as well as it provides the star point conductor as a neutral point. This can serve single phase as well as three phase loads.

Description : Why is an auto-transformer not used as a distribution transformer?

Last Answer : The autotransformer cannot provide isolation between HV and LV side. Due to open circuit in the common portion, the voltage on the load side may shoot up to dangerously high voltage ... voltage on LV side is potentially dangerous. Hence the autotransformer cannot be used as distribution transformer

Description : What are the salient features of distribution transformer?

Last Answer : 1. The distribution transformer will have low iron loss and higher value of copper loss 2. The capacity of transformers will be up to 500 KVA 3. The transformers will have plain walled ... with cooling tubes or radiators. 4. The leakage reactance and regulation will be low.

Description : Why the efficiency of distribution transformer is 60 to 70 % and not 100%?

Last Answer : Distribution transformer is designed for maximum efficiency at 60% to 70% load as it normally doesn't operate at full load all the time. Its load depends on distribution demand. Whereas power transformer ... efficiency at 100% load as it always runs at 100% load being near to generating station.

Description : What are distribution transformer?

Last Answer : The distribution transformer is used for the distribution of electrical energy at low voltage as less than 33KV in industrial purpose and 440v-220v in domestic purpose. It works at low efficiency at 60-70%, small size, easy in installation, having low magnetic losses & it is not always fully loaded.

Description : Where are the lighting arrestors placed in distribution lines?

Last Answer : Near distribution transformers and outgoing feeders of 11kv and incoming feeder of 33kv and near power transformers in sub-stations.

Description : What is the distribution of DC control supply in CL IV, III, II- 415V and 6.6 kV?

Last Answer : Closing coil and Trip coil 2 supply from one source. Trip coil 1 supply from one source. Protections supply from one source. 

Description : What is the vector group of distribution transformer?

Last Answer : Dy11.  

Description : What will happen when power factor is leading in distribution of power?

Last Answer :  If there is high power factor, i.e if the power factor is close to one:  Losses in form of heat will be reduced,  Cable becomes less bulky and easy to carry, and very cheap to afford.  It also reduces over heating of transformers.

Description : Harmonics are eliminated by using a) Skewing of rotor b) Distribution winding c) Short pitch winding d) All of the above

Last Answer : Ans: All of the above