Where should the lighting arrestor is placed in distribution lines?

1 Answer

Answer :

Near distribution transformers and out going feeders of 11kv and incoming feeder of 33kv and near power transformers in sub-stations.

Related questions

Description : Where should the lighting arrestor be placed in distribution lines?

Last Answer : A:Near distribution transformers and out going feeders of 11kv and incomming feeder of 33kv and near power transformers in sub-stations.

Description : Where are the lighting arrestors placed in distribution lines?

Last Answer : Near distribution transformers and outgoing feeders of 11kv and incoming feeder of 33kv and near power transformers in sub-stations.

Description : The purpose of the automatic bus transfer shown in the illustration is to ___________. EL-0014 A. stepdown voltage to the lighting distribution panel B. provide emergency power to ... emergency switchboard from the main switchboard D. provide overcurrent protection to the lighting distribution panel

Last Answer : Answer: B

Description : In the lighting distribution circuit shown in the illustration, if all switches are closed and fuse 'F2' were to open, all lights on branches ____________. EL-0013 A. '1', '2', and '3' would go out B. '1' ... and '3' would burn dimly D. '1' and '3' would go out, while branch '2' would remain lit

Last Answer : Answer: D

Description : If the illustrated lighting branch distribution box is not for cargo or deck lighting, the Coast Guard Regulations (46 CFR) requires the designed load attached to Branch NO.2 to be no more than _________. EL-0013 A. 5 amps B. 16 amps C. 30 amps D. 50 amps

Last Answer : Answer: B

Description : What is the difference between surge arrestor and lightning arrestor?

Last Answer : LA is installed outside and the effect of lightning is grounded, where as surge arrestor installed inside panels comprising of resistors which consumes the energy and nullify the effect of surge.

Description : What Is The Difference Between Surge Arrestor And Lightning Arrestor?

Last Answer : LA is installed outside and the effect of lightning is grounded,where as surge arrestor installed inside panels comprising of resistors which consumes the energy and nullify the effect of surge.

Description : What is the difference between surge arrestor and lightning arrestor?

Last Answer : A:Lightning Arrestor is installed outside and the effect of lightning is grounded where as surge arrestor installed inside panels comprising of resistors which consumes the energy and nullify the effect of surge.

Description : What is the difference between surge arrestor and lightning arrestor?

Last Answer : Lightning arrestor is installed outside and the effect of lightning is grounded, whereas surge arrestor installed inside panels comprising of resistors which consumes the energy and nullify the effect of surge.

Description : What is the type of Lightning Arrestor?

Last Answer : Station type, heavy duty, gap less zinc oxide.  

Description : What is the purpose of lightning arrestor? 

Last Answer : Due to lightning and switching surges high voltages are induced in the lines. If equipment's. Connected is subjected to this high voltage the insulation will fail. In order to avoid the failure of ... current to the earth. (It will divert the over voltages to earth and protect the substation)  

Description : For a fault in switchyard lightning arrestor, what protection will act?

Last Answer : Bus bar differential protection.  

Description : Give the details of switchyard 220 kV CB, Isolator, CT, CVT and lightning arrestor.  

Last Answer : 220 kV SF6 Circuit Breaker 1. Make - ABB 2. Air pressure blocking a. Close Block - 17.3 bar. b. Open block - 16.7 bar. c. Auto reclose block - 19 bar. 3. SF6 pressure block a. Alarm - 5. ... , storage and erection. Rated voltage : 216 kV rms. Operating voltage : 184 kV rms. 

Description : What is the type of lightning arrestor for GT? 

Last Answer : Zn O (zinc oxide) types.  

Description : In 220 kV switchyard why lightning arrestor should be properly grounded?

Last Answer : a. During lightning, surges should be discharged to ground, otherwise it will puncture the equipment insulation and it is possible only when lightning arrestor is grounded properly.  b. In order to make it effective ... kV. Soil resistivity a should be minimum and may be it is 3.5 ohm per meter.  

Description : Write types of lightning arrestor.

Last Answer : a. Horn gap lightning arrestor. b. Oxide film lightning arrestor. c. Pellet lightning arrestor. d. Thyrite lightning arrestor.

Description : Handheld phase sequence indicators are useful when ________. A. preparing to parallel alternators B. connecting lighting branch circuits C. troubleshooting DC motors D. connecting shore power lines to the ship

Last Answer : Answer: D

Description : How does a lightning arrestor work?

Last Answer : ANSWER I: Lightning, is a form of visible discharge of electricity between rain clouds or between a rain cloud and the earth. The electric discharge is seen in the form of a brilliant arc, ... a cone of protection, which has a ground radius approximately, equal to its height above the ground.

Description : What is the difference between flash back arrestor and check valve? 

Last Answer : A check valve allows flow in one direction only. This prevents oxygen reaching acetylene cylinder and acetylene reaching oxygen cylinder in the event of blockage in the torch or line or pressure variations.

Description : When supplying emergency lighting loads, the storage battery initial voltage must not exceed the standard system voltage by more than _____________. A. 2% B. 3% C. 5% D. 10%

Last Answer : Answer: C

Description : According to Coast Guard Regulation (46 CFR) for emergency power and lighting systems, which of the listed items is the only permissible starting aid for the emergency diesel generator engine? A. Ether B. Lube oil heater C. Jacket water heater D. Fuel oil heater

Last Answer : Answer: C

Description : Which of the following statements is/are true regarding requirements for receptacle outlets aboard vessels? A. Each receptacle outlet operating at 100 volts or more must have a grounding pole. B. Outlets ... machinery with a portable light having a 50 foot flexible cord. D. All of the above.

Last Answer : Answer: A

Description : Coast Guard Regulations (46 CFR) require that lighting fixture globes must be protected by guards if the fixtures are located in the ____________. A. steering gear room B. galley C. living quarters D. wheelhouse

Last Answer : Answer: A

Description : The source of emergency lighting and power at loss of normal ship's power on a cargo vessel should be obtained from the ______________. A. emergency generator supply to the emergency ... switchboard C. battery supply to the main switchboard D. turbogenerator supply to the emergency switchboard

Last Answer : Answer: A

Description : The electrical schematic shown in the illustration indicates the lighting feeder circuit is _____________. EL-0014 A. three phase, 450 volt, and 60 cycle B. three phase, 120 volt, and 60 cycle C. single phase, 120 volt, and 60 cycle D. not specified

Last Answer : Answer: A

Description : If the voltage supplied to the lighting circuit is 110 volts, how much current is used by a 100 watt light bulb? A. 0.08 amps B. 0.91 amps C. 1.10 amps D. 90.9 amps

Last Answer : Answer: B

Description : In the illustration if BRANCH NO. 1 is a lighting circuit for crew's berthing, Federal Regulations (46 CFR) require the maximum fuse rating for that branch to be _________. EL-0013 A. 80% of the connected load B. 15 amps C. 20 amps D. 30 amps

Last Answer : Answer: C

Description : In the illustration if BRANCH NO. 1 is a lighting circuit for crew's berthing, 46 CFR requires the maximum fuse rating for that branch to be _________. EL-0013 A. 15 amps B. 80% of the connected load C. 20 amps D. 30 amps

Last Answer : Answer: C

Description : Due to the operating characteristics of the system, time lag fuses (or dual-element fuses) are necessary for use in _____________. A. main lighting circuits B. motor starting circuit C. emergency lighting circuits D. general alarm circuits

Last Answer : Answer: B

Description : Transformers are used onboard ships with AC generators to _____________. A. change frequency B. increase power output to modulating frequency controllers C. decrease power output to modulating frequency ... D. permit higher voltage for electric motor operation and low voltage for lighting circuits

Last Answer : Answer: D

Description : Which of the following components are used to assemble a fluorescent lighting system? A. Lamp B. Starter C. Ballast D. All of the above

Last Answer : Answer: D

Description : Time delayed or delayed action-type fuses are designed to _____________. A. prevent grounds in branch circuits B. prevent opens in motor circuits C. permit momentary overloads without melting D. guard lighting and electronic circuits

Last Answer : Answer: C

Description : A delayed-action fuse is most frequently used in which of the listed circuits? A. Lighting circuit B. Motor circuit C. Electric heater circuit D. Radar circuit

Last Answer : Answer: B

Description : Which of the listed types of lighting circuits does the diagram shown in the illustration represent? EL-0081 A. High pressure sodium B. Low voltage quartz C. Mercury vapor D. Standard fluorescent

Last Answer : Answer: D

Description : The diagram shown in the illustration represents a _________. EL-0058 A. dual speed, 2-winding motor controller B. navigation running light circuit C. single phase, 2-motor selectable starter D. common fluorescent lighting circuit

Last Answer : Answer: B

Description : Why Delta Star Transformers are used for Lighting Loads?

Last Answer : A. For lighting loads, neutral conductor is must and hence the secondary must be star winding.This lighting load is always unbalanced in all three phases. To minimize the current unbalance in the primary we use delta winding in the primary. So delta / star transformer is used for lighting loads.

Description : Why Delta Star transformer Are Used For Lighting Loads?

Last Answer : For lighting loads, neutral conductor is must and hence the secondary must be star winding. and this lighting load is always unbalanced in all three phases. To minimize the current unbalance in the primary we use delta winding in the primary. So delta / star trformer is used for lighting loads.

Description : What types of lighting fittings are used in the battery room?

Last Answer : Flame proof acid resistant  

Description : Why lighting isolation transformer is req.? 

Last Answer : a) 3 wire to 4 wire conversion, since neutral is required for lighting load. b) Prevents transfer of E/F currents c) Reduces the fault level on secondary side and permits use of small sized cables / CB’s / fuses.

Description : What are the lighting systems adopted in KGS?

Last Answer : There are two systems.  a. Normal lighting with class IV power supply.  b. Emergency lighting with class II power supplies and in control room with class I power supplies. 

Description : What are the types of lighting?

Last Answer : a. Direct lighting: light directly comes from the source to the surface. b. Indirect lighting: light reflects from the wall, reflector or ceilings etc. c. Semi direct lighting: light comes through the shade.

Description : Why Delta Star Transformers are used for Lighting Loads?

Last Answer : For lighting loads, neutral conductor is must and hence the secondary must be star winding and this lighting load is always unbalanced in all three phases.  To minimize the current unbalance in the primary we use delta winding in the primary So delta / star transformer is used for lighting loads.

Description : Which one of the following statements relating to the differences between industrial and consumer marketing is FALSE? A)Distribution channels tend to be shorter for industrial products than for ... and economic constraints placed on pricing is roughly the same for industrial and consumer products

Last Answer : C)The number of legal and economic constraints placed on pricing is roughly the same for industrial and consumer products

Description : iv) A rectangular coil free to rotate is placed in uniform magnetic field with its plane parallel to the magnetic lines of force. Then the coil willa) rotate to maximize the magnetic flux through ... since the magnetic flux through its plane is zero.d) experience the constant torque equal to NBIA

Last Answer : iv) A rectangular coil free to rotate is placed in uniform magnetic field with its plane parallel ... d) experience the constant torque equal to NBIA

Description : When an iron piece is placed in a magnetic field (a) the magnetic lines of force will bend away from their usual paths in order to go away from the piece (b) the magnetic lines of force will bend ... to pass through the piece (c) the magnetic field will not be affected (d) the iron piece will break

Last Answer : (b) the magnetic lines of force will bend away from their usual paths in order to pass through the piece

Description : In case of two identical charges placed at certain distance, the electric lines of force are: (a) Curved (b) Straight lines (c) Both (a) and (b) (d) None of these

Last Answer : a) Curved