In buchholz relay how the top and bottom mercury switches are connected?  

1 Answer

Answer :

Top mercury switch is connected for alarm and bottom switch for trip.  

Related questions

Description : In buchholz relay how the top and bottom mercury switches are connected?

Last Answer : Top mercury switch is connected for alarm and bottom switch for trip.

Description : What Is Buchholz Relay And The Significance Of It In To The transformer ?

Last Answer : Buchholz Relay is a device which is used for the protection of transformer from its internal faults, it is a gas based relay. whenever any internal fault occurs in a transformer, the Buchholz Relay ... then it stop its sound itself other wise it trips the circuit by its own tripping mechanism.

Description : What is buchholz relay and the significance of it in to the transformer?

Last Answer : A:Buchholz relay is a gas based relay which is used for the protection of transformer from its internal faults. whenever any internal fault occurs in a transformer, the buchholz relay at once gives an ... then it stop its sound itself other wise it trips the circuit by its own tripping mechanism.

Description : Where is buchholz relay located?

Last Answer : It is located between transformer tank and conservator.

Description : What is buchholz relay?

Last Answer : It protects the transformer from their internal faults like earth faults, winding short circuit, short circuit between phases, Puncture of bushing etc..

Description : what is Buchholz relay and the significance of it in to the transformer?

Last Answer : Buchholz relay is a device which is used for the protection of transformer from its internal faults, it is a gas based relay. whenever any internal fault occurs in a transformer, the Buchholz ... circuit then it stop its sound itself otherwise it trips the circuit by its own tripping mechanism.

Description : What are the limitations of Buchholz relay?

Last Answer : (a) Only fault below the oil level are detected. (b) Mercury switch setting should be very accurate, otherwise even for vibration, there can be a false operation. (c) The relay is of slow operating type, which is unsatisfactory.

Description : What is the use of buchholz relay in the transformer?

Last Answer : It's a protection relay used in oil immersed transformer to protect the transformer from insulation failure, core heating or any other type of internal faults, which may cause the heating of ... relay first operates and then the trip relay operates to isolate the transformer from the circuit.

Description : 76 The changes in volume of transformer cooling oil due to variation of atmospeheric temperature during day and night is taken care of by which part of transformer? A. Conservator B. Breather C. Bushings D. Buchholz relay

Last Answer : A. Conservator

Description : Describe the construction and Operation of Buchholz relay with neat labeled diagram.

Last Answer : Construction of Buchholz Relay: It takes the form of a domed vessel placed in the connecting pipe between the main tank and the conservator. The device has two elements. The upper element ... manner that it senses the sudden violent movement of oil/gas from transformer tank to conservator. 

Description : Explain Buchholz relay with neat labelled diagram.

Last Answer : Buchholz relay: The relay is located in the path of the oil from transformer tank to conservator. As seen from diagram, the upper mercury switch operates the alarm circuit due to tilting of the ... manner that it senses the sudden violent movement of oil from transformer tank to conservator.

Description : Buchholz relay is  (1) located in the conservator tank  (2) located in the transformer tank itself  (3) connected in the pipe connecting main tank of transformer and conservator  (4) installed in the circuit breaker

Last Answer : Buchholz relay is connected in the pipe connecting main tank of transformer and conservator 

Description : Buchholz relay is used as a safety device with respect to which of the following? A) Audio transformers B) Oil filled power transformers C) Air core transformer D) None of these

Last Answer : Buchholz relay is used as a safety device with respect to which of the following? A) Audio transformers B) Oil filled power transformers C) Air core transformer D) None of these

Last Answer : A Buchholz relay can be installed on oil cooled transformers.

Description : What is the use of Buchholz relay in transformer?

Last Answer : This is a transformer that is used to step up and down current. 

Last Answer : The buchholz relay is one type of relay which is used in the oil filled power transformerand is for the safety device .

Description : Motor controllers are seldom troubled with grounds because _____________. A. the auxiliary contacts have a high resistance connection B. the contactors and relays are mounted on a nonconducting panel ... individual series-connected units D. there are separate switches for the motor and the control

Last Answer : Answer: B

Description : Batteries 'A' and 'B' shown in the illustration are 6 volts each and batteries 'C' and 'D' are 24 volts each. If 'A' were connected in series-opposing to 'C' and 'B' was similarly ... the top terminal C. 30 volts, negative at the bottom terminal D. 30 volts, positive at the bottom terminal

Last Answer : Answer: A

Description : In Frame Relay, when a _____ is selected, the correspondingtable entry is recorded for all switches by the administrator A) PVC B) SVC C) either (a) or (b) D) neither (a) nor (b)

Last Answer : PVC

Description : A piece of metal of specific gravity 13.6 is placed in mercury of specific gravity 13.6, what fraction of it volume is under mercury? (A) The metal piece will simply float over the mercury (B ... will be immersed with its top surface just at mercury level (D) Metal piece will sink to the bottom

Last Answer : Answer: Option C

Description : When an operating motor is connected to the controller shown in the illustration, the a path of current flow through the circuit is ____________. EL-0010 A. 'L1', stop button, start button, coil 'CR', 'L2' B. 'L1' ... L2' D. 'L1', stop button, start button, 'CR' contact, 'M' contact, 'CR' coil, 'L2'

Last Answer : Answer: B

Description : The small circular symbols to which wire '52N57E' is connected at coordinates '57L' and '57P' shown in the illustration represent ___________________. EL-0100 A. relay contact solder points B. wire wrap connections C. terminal board screws D. switch contact terminals

Last Answer : Answer: C

Description : Regarding an AC generator connected to the main electrical bus; as the electric load and power factor vary, a corresponding change is reflected in the generator armature reaction. These changes in ... . governor speed droop setting B. voltage regulator C. balance coil D. phase-balance relay

Last Answer : Answer: B

Description : Which of the following statements represents the main difference between a relay and a contactor? A. Contactors control current and relays control voltage. B. A relay is series connected and a contactor ... loads than relays. D. Contactors are made from silver and relays are made from copper.

Last Answer : Answer: C

Description : DC relay coil or contactor coils must be connected to which side?

Last Answer : Negative side of the DC supply to avoid galvanic effect on the coil, which will corrode the coil.  

Description : A ________network is made of a set of switches connected by physical links, in which each link is divided into nchannels. A) line-switched B) frame-switched C) circuit-switched D) none of the above

Last Answer : circuit-switched

Description : Which of the following statements accurately describe the differences between a hub and a switch? Check all that apply. A. A switch remembers which devices are connected on each interface, while a hub does not. B. A hub is a ... versions of switches. a. A,B b. A,B,C c. A,B,C,D d. A,C,D

Last Answer : b. A,B,C

Description : Anti-siphonage pipe is connected to (A) Main soil pipe (B) Bottom of P trap W.C. (C) Top of P trap W.C. (D) Side of water closet

Last Answer : (C) Top of P trap W.C.

Description : belt of silk runs over two metal pulleys, one of which is surrounded by a hollow metal sphere. Two electrodes, in the form of comb-shaped rows of sharp metal points, are positioned ... potential is applied to the upper pulley. A simple version of which equipment is being described here?

Last Answer : Van de Graaff generator.

Description : Where is the fuel pump relay located on a 1988 Mercury Cougar?

Last Answer : http://www.coolcats.net/help/inertia.html behind back seat, passenger side.

Description : When maintenance personnel are working on electrical equipment, all supply switches should be secured in the open position and tagged specifically by the _____________. A. watch engineer B. chief engineer or first assistant C. chief electrician D. person performing the repair

Last Answer : Answer: D

Description : Which of the following statements represents the FIRST precaution to be taken prior to working on any installed electrical component? A. Wear rubber gloves and boots. B. Use only approved nonconducting ... the machine before beginning any repairs. D. Open the supply circuits and tag the switches.

Last Answer : Answer: D

Description : Regarding the illustrated electrical schematic, 'S1-P', 'S1-Q', and 'S1-R' represent ____________. EL-0016 A. capacitors B. normally-closed contacts C. normally-open contacts D. normally-closed pushbutton switches

Last Answer : Answer: C

Description : In the lighting distribution circuit shown in the illustration, if all switches are closed and fuse 'F2' were to open, all lights on branches ____________. EL-0013 A. '1', '2', and '3' would go out B. '1' ... and '3' would burn dimly D. '1' and '3' would go out, while branch '2' would remain lit

Last Answer : Answer: D

Description : As shown in the illustration, all 'MS' contacts are opened and closed by means of ________. EL-0073 A. operating coils B. magnets C. manual operation of the master switches D. solenoid switches

Last Answer : Answer: C

Description : Which of the devices shown in the illustration automatically prevents the simultaneous operation of the windlass from both master switches? EL-0073 A. Selector switch B. Contact 'CR1a' C. Contact 'CR2a' D. Contact 'CR1D'

Last Answer : Answer: D

Description : As part of a routine maintenance program for deck machinery, you should ___________. A. inspect electrical wiring and pushbutton switches for evidence of corrosion or burned insulation B. disassemble ... covers and ventilate as weather permits D. Check drum switch contact pressure every three months

Last Answer : Answer: A

Description : With the selector switches set for R X 10,000 and the leads placed in the proper receptacles, the needle settles on the '150' mark. What is the resistance value between the leads? EL-0047 A. 1500 ohms B. 150,000 ohms C. 1,500,000 ohms D. 1.5 ohms

Last Answer : Answer: C

Description : When the master switch for the winch shown in the illustration is in the 'off' position, and the line & safe switches are closed, which of the listed relays should be energized? EL-0102 A. 'DB' & '2T' B. 'DB' & '4M' C. 'FR-B.O.' & 'LV' D. '1M' & '1A'

Last Answer : Answer: C

Description : Discharge switches are often located on hand-driven meggers. The purpose of these switches is to discharge capacitive charges stored in the _____________. A. megger hand generator B. megger movement coils C. tested equipment while conducting test D. tested equipment after testing

Last Answer : Answer: D

Description : A 'dead front' switchboard is one _____________. A. without switches on it B. with insulated switches and no exposed terminals C. without circuit breakers D. without safety hand rails nor rubber mats

Last Answer : Answer: B

Description : On an engine throttle control system, the auxiliary control circuits are provided with devices to prevent excessive overtravel of the pilot valve by the synchronous motor. These devices are called _________________. A. overlap sensors B. limit switches C. overtravel relays D. proximity switches

Last Answer : Answer: B

Description : Moisture damage, as a result of condensation occurring inside of the cargo winch master switches, can be reduced by __________________. A. installing a light bulb in the pedestal stand B. coating the ... epoxy sealer C. venting the switch box regularly D. using strip heaters inside the switch box

Last Answer : Answer: D

Description : Why Isolation switches are provided along with the circuit breakers?

Last Answer : Isolation switches are provided for separating the disconnected element from the live portion of the system for the purpose of safety

Description : Why are centrifugal switches provided on many 1-phase Induction motors?

Last Answer : Centrifugal switches are provided on many 1-phase Induction motors to disconnect the starting / auxiliary winding from the supply when the motor reaches about 70% of its synchronous speed.

Description : Why earth switches are provided in 220 kV bays?  

Last Answer : When bay CB trips, both end (station and grid) CB will trip. The earth switches are provided because the grid will always be alive so to prevent any shocks to the operator or maintenance personnel who is working on the line or bay due to accidental energizing of the bus.  

Description : When testing for blown fuses in a three-phase supply circuit to a motor, you should first ___________________. A. apply the megger across the tops of the line fuses B. apply an ammeter diagonally across ... of the line fuses D. ensure the circuit is de-energized, and then use a continuity tester

Last Answer : Answer: D

Description : The following air gap readings were obtained from a horizontally mounted, bilge pump, induction motor, equipped with sleeve bearings: FWD END-AFT END, Top .045 - .049, Right Side .045 - .047, Left ... the aft bearing. C. The forward bearing should be lowered. D. The aft bearing should be lowered.

Last Answer : Answer: A