A 'dead front' switchboard is one _____________. A. without switches on it B. with insulated switches and no exposed terminals C. without circuit breakers D. without safety hand rails nor rubber mats

1 Answer

Answer :

Answer: B

Related questions

Description : A ground is indicated by the ground-detecting system on the main electrical switchboard. The FIRST step in locating the actual ground is to _____________. A. close all circuit breakers in ... ground detection system indicates normal C. change over generators D. check each circuit with a megohmmeter

Last Answer : Answer: B

Description : The purpose of a main switchboard circuit breaker's reverse-power trip is to _____________. A. prevent main circuit overload B. protect the circuit breaker blowout coil C. prevent alternator motorization D. prevent low voltage tripout

Last Answer : Answer: C

Description : To properly use a hook-on-type volt/ammeter to check current flow, you must FIRST _____________. A. de-energize the circuit to allow connection of the instrument in series B. hook the jaws ... test leads to the appropriate terminals D. short the test leads and calibrate the instrument to zero

Last Answer : Answer: B

Description : Explain the uses of safety rubber hand gloves and rubber mats in electrical engineering. 

Last Answer : Uses of safety rubber hand gloves in electrical engineering:  * The safety rubber hand gloves are always used for online work to insulate the human body or operator from the electrical supply. * The ... human body) is isolated from ground or earth i.e. why danger of electrical shock is avoided. 

Description : Undervoltage trips are frequently installed on switchboard circuit breakers to trip ____________. A. out generators in the event of severe arcing or sparking B. out generators when there is reversal of power ... , but continues to run D. out generators when there is low voltage in the main circuit

Last Answer : Answer: D

Description : Why Isolation switches are provided along with the circuit breakers?

Last Answer : Isolation switches are provided for separating the disconnected element from the live portion of the system for the purpose of safety

Description : Before touching a small capacitor connected to a de-energized circuit, or even one that is completely disconnected, you should ____________. A. gently tap the body with a screwdriver B. tag it ... insulated fuse puller D. short circuit the terminals to make sure that the capacitor is discharged

Last Answer : Answer: D

Description : A ground in an electrical circuit outside the engine room _____________. A. cannot be detected under normal conditions B. is of no consequence to engineering personnel C. is indicated at the branch circuit breaker panel D. is indicated by the ground detecting lamps on the main switchboard

Last Answer : Answer: D

Description : Discharge switches are often located on hand-driven meggers. The purpose of these switches is to discharge capacitive charges stored in the _____________. A. megger hand generator B. megger movement coils C. tested equipment while conducting test D. tested equipment after testing

Last Answer : Answer: D

Description : The electrical energy necessary to transmit a person's voice over a sound-powered telephone circuit is obtained from _____________. A. dry cell batteries B. the ship's service switchboard C. the emergency switchboard D. the speaker's voice

Last Answer : Answer: D

Description : Rubber Mats and Workplace Safety?

Last Answer : Whether a business is operating in an industrial setting or aretail environment, rubber mats can be very useful in ensuringemployee safety and comfort. Rubber mats are particularly usefulfor ... also be very helpful inincreasing general workforce safety. For example, rubber mats areroutinely used

Description : Fault diverters are basically (a) fuses (b) relays (c) fast switches (d) circuit breakers

Last Answer : (c) fast switches

Description : When changing fuses, you should always _____________. A. wear rubber boots B. use a fuse puller C. stand on a rubber mat D. wear safety glasses

Last Answer : Answer: B

Description : At dead short circuit at terminals of Alternator then the current I is a) ZPF Lag b) ZPF lead c) Unity power factor d) 0.8 Power factor lag

Last Answer : Ans: ZPF Lag

Description : Receptacle outlets aboard ship should be designed so those mounted according to 46 CFR 111 have _____________. A. there must be a sufficient number of receptacle outlets in the crew accommodations for an ... outlet must not have any exposed parts with the plug opening uncovered D. all of the above

Last Answer : Answer: D

Description : A ground on a particular phase of a three-phase low voltage distribution system would be indicated by a _____________. A. high switchboard wattmeter reading B. low switchboard wattmeter reading C. dark or dim switchboard ground detecting light D. bright switchboard ground detecting light

Last Answer : Answer: C

Description : A switchboard ammeter indicates a reading slightly above 'zero' when the leads are disconnected, this is caused by _____________. A. mechanical misalignment of the meter pointer B. a poor ground for the meter case C. static electricity in the air D. capacitors inside the meter storing charges

Last Answer : Answer: A

Description : A current-carrying conductor making electrical contact with a wiring conduit will be indicated by a _____________. A. high switchboard wattmeter reading B. totally dark switchboard ground detecting light C. low switchboard wattmeter reading D. all of the above

Last Answer : Answer: B

Description : A current-carrying conductor makes accidental contact with a wiring conduit. This will be indicated by a _____________. A. low switchboard wattmeter reading B. high switchboard wattmeter reading C. darkened switchboard ground detecting lamp D. darkened switchboard synchronizing lamps

Last Answer : Answer: C

Description : A current carrying conductor making an electrical contact with a wiring metal conduit is indicated by a _____________. A. low switchboard wattmeter reading B. reading of 1.0 on the power factor meter C. high switchboard voltmeter reading D. totally darkened switchboard ground-detecting light

Last Answer : Answer: D

Description : Automatic voltage regulators provided on switchboards function to _____________. A. regulate the AC load on the generator B. protect the switchboard from high voltage C. govern prime mover speed to control voltage D. vary the field excitation to the generators

Last Answer : Answer: D

Description : The frequency of an alternator is controlled from the main switchboard by adjusting the _____________. A. frequency meter B. voltage regulator C. governor control D. sychroscope switch

Last Answer : Answer: C

Description : The 24 volt DC bus on the emergency switchboard is used to supply power to the _____________. A. general alarm system B. gyrocompass power failure alarm system C. smoke detection system D. all of the above

Last Answer : Answer: D

Description : The part of the shipboard electrical system used to control the distribution of power to the branch circuits, is the _____________. A. bridge control panel B. disconnect links C. governor relay box D. main switchboard

Last Answer : Answer: D

Description : When replacing fuses, always make sure _______________. A. to stand on a rubber mat and use rubber gloves B. to use insulated pliers or screwdriver C. the fuse clips are straight, tight, and in good contact D. to increase the fuse rating 10% to guard against 'nuisance blowing'

Last Answer : Answer: C

Description : The electrical energy necessary to power a sound-powered telephone's small vibrating bell is obtained from _________. A. the emergency batteries for the general alarm B. each station's hand-cranked generator C. the emergency switchboard D. normal 115 volt DC supplies

Last Answer : Answer: B

Description : One of the generator bearing shells is generally insulated from the end housing in order to prevent _____________. A. rapid brush wear B. residual magnetism leak off C. excessive field winding heat D. circulation of shaft currents

Last Answer : Answer: D

Description : When changing fuses and the spring clips are found to have lost their grip, they should be replaced or _____________. A. tightened firmly with insulated pliers B. clip clamps should be used C. wired closed with uninsulated, varnished copper wire D. carefully bent back to their original shapes

Last Answer : Answer: B

Description : When a transformer is used to step down voltage, the low voltage winding is _____________. A. part of the core B. the primary coil C. not insulated D. the secondary coil

Last Answer : Answer: D

Description : A tubular fuse should always be removed from a fuse panel with _____________. A. a screwdriver B. a pair of insulated metal pliers C. any insulated object D. fuse pullers

Last Answer : Answer: D

Description : Which of the following statements represents the FIRST precaution to be taken prior to working on any installed electrical component? A. Wear rubber gloves and boots. B. Use only approved nonconducting ... the machine before beginning any repairs. D. Open the supply circuits and tag the switches.

Last Answer : Answer: D

Description : When maintenance personnel are working on electrical equipment, all supply switches should be secured in the open position and tagged specifically by the _____________. A. watch engineer B. chief engineer or first assistant C. chief electrician D. person performing the repair

Last Answer : Answer: D

Description : Motor controllers are seldom troubled with grounds because _____________. A. the auxiliary contacts have a high resistance connection B. the contactors and relays are mounted on a nonconducting panel ... individual series-connected units D. there are separate switches for the motor and the control

Last Answer : Answer: B

Description : When using a multimeter for resistance measurements, it should be calibrated by clipping the loose ends of the leads together and _____________. A. setting the instrument pointer at 'zero' ohms B. ... the plus and minus terminals D. using a special purpose resistance measuring instrument (a bridge)

Last Answer : Answer: A

Description : Routine maintenance of lead acid batteries should include _____________. A. keeping the terminals clean B. coating cable connections with petroleum jelly C. maintaining a trickle charge D. all of the above

Last Answer : Answer: D

Description : In accordance with Coast Guard Regulations (46 CFR), a steering gear feeder circuit from the emergency switchboard or alternate power supply must have the capacity for continuous operation of the rudder 15° side to side in not more than 60 seconds for a A. 1/4 hour B. 1/2 hour C. 1 hour D. 2 hours

Last Answer : Answer: B

Description : Coast Guard Regulations (46 CFR) require each switchboard to have ___________. A. non-conductive deck covering at the frount B. non-conductive deck coverings at the rear C. a name plate for each circuit breaker D. all the above

Last Answer : Answer: D

Description : Before any work on electrical or electronic equipment is performed, which of the following precautions should be carried out? A. De-energize the applicable switchboard bus. B. Bypass the interlocks. C. ... supply circuit breaker in the open position. D. Station a man at the circuit supply switch.

Last Answer : Answer: C

Description : Why You Need Heavy-Duty Rubber Mats?

Last Answer : Industrial settings are probably the roughest sorts of conditions out there. Industrial facilities, building destinations, or warehouses are largely home to hard and large equipment that can cause ... slip-protection from feet. At the point when individuals stroll over substantial heavy duty rubber

Description : How to Use Rubber Mats in the Workplace?

Last Answer : Investing in a handful of high quality rubber mats for yourworkplace can be a great way to provide your employees with a saferand more comfortable environment. There is an endless ... popular types of rubber mats in retail andcertain commercial settings is designed exclusively to provideworkers

Description : Rubber Mats and Their Myriad of Uses?

Last Answer : Rubber mats and flooring have become such an integral part ofour everyday lives that many give little consideration to whererubber actually comes from. There are two sources of rubber,natural ... a multitude of recreational,industrial and agricultural purposes due to its non-porous nature.These mat

Description : Good Places to Use Rubber Mats?

Last Answer : Rubber mats protect the surfaces that they are on and also makethe surfaces slip resistant. They are best for places thatexperience a lot of water or mud exposure on a regular basis.Rubber mats come ... attached to your car.They are also durable and can last for several years.Truck BedsMany people

Description : When used for taking resistance measurements, a volt-ohm-milliammeter is normally powered by _____________. A. a hand cranked generator B. internal storage batteries C. the current in the circuit being tested D. a step down transformer

Last Answer : Answer: B

Description : The simplest method of controlling the terminal voltage of compound-wound DC generator is with a _____________. A. hand-operated field rheostat connected in series with the shunt field circuit B. ... in series with the load D. balance coil diverting neutral current through the shunt field

Last Answer : Answer: A

Description : Accidental grounds in a shipboard electrical system must be repaired as soon as possible as they will ____________. A. result in immediate power outages B. damage circuit breakers C. appear on the ground detection system D. damage insulation and may cause outages

Last Answer : Answer: D

Description : During maintenance of circuit breakers, _______________. A. always smooth roughened contact surfaces with a file B. never pass more than rated breaker current through the overload heater element C. ... wear and misalignment of main contacts D. assume heater elements installed are of correct size

Last Answer : Answer: C

Description : Periodic testing of circuit breakers is necessary to assure that a correctly rated and properly installed unit _________________. A. can trip faster as it increases in age B. will continue to provide ... not exceed its interrupting capacity D. be able to withstand at least 125% of applied voltage

Last Answer : Answer: B