What are the characteristics of CB, OLR and HRC Fuse?

1 Answer

Answer :

image

image

When CB is used the CB characteristics should be below the fuse, because the CB should operate first and then fuse. Not vice-versa. Because CB is the main protection or main breaking device.  

Related questions

Description : Explain construction and characteristics of HRC fuse.

Last Answer : Construction of H.R.C. Fuse: Figure shows the essential parts of a typical H.R.C. fuse. It mainly consist of a heat resisting ceramic body. Both the ends of the cermaic body consists ... particular circuit and for coordination purpose. A typical Fuse characteristic is shown in figure below. 

Description : Capacity of battery fuse in AC Coaches a. 315 A & 400 (HRC ) c. 16 A (HRC ) b. 63 A (HRC ) d. 5 A (HRC )

Last Answer : a. 315 A & 400 (HRC )

Description : Describe the working of HRC fuse with neat diagram.

Last Answer : Working of HRC Fuse: Under normal conditions, the fuse element is at a temperature below its melting point. Therefore, it carries the normal current without overheating. When a fault ... powder and results in the formation of high resistance substance that helps in quenching the arc. 

Description : ln HRC fuse the time between cut-off and final current zero is called

Last Answer : ln HRC fuse the time between cut-off and final current zero is called the arcing time

Description : what is HRC fuse?

Last Answer : HRC (High Rupturing Capacity) fuse HRC fuse is High Rupturing Capacity fuse. At the time of fault it disconnect the circuit very fast. Filling powder is silica sand. No flashover ... speed response Reliable No maintenance CheaperDisadvantages:- We have to replace it manually after each operation.

Description : Why OLR time set high for belt driven fans?

Last Answer : Because acceleration time is high.  

Description : What are the materials made of thermal overload relay? How OLR are selected?

Last Answer : The bimetallic materials are Invar and brass. These materials having the differential coefficient of expansion. All bimetallic relays incorporate additional built in single phasing protection. The range of the relay provided ... at Centre) except in very minimum loads ranging from 0.1 - 0.16 A. 

Description : How the required conductor size can be reduced by use of HRC fuses?

Last Answer : HRC fuse limits the peak amplitude of fault current. HRC fuse melts at prospective current but not allows circuit to pass their high rupturing capacity that is it’s kA. 

Description : What are HRC fuses and where it is used?

Last Answer : HRC stand for "high rupturing capacity" fuse and it is used in distribution system for electrical transformers.

Description : Draw O/P characteristics of CB configuration and explain its working.

Last Answer : In common base configuration, emitter is the input terminal, collector is the output terminal and base terminal is connected as a common terminal for both input and output. The base-emitter ... In this region, a small collector current flows called leakage current when emitter current is zero.

Description : Give the details of switchyard 220 kV CB, Isolator, CT, CVT and lightning arrestor.  

Last Answer : 220 kV SF6 Circuit Breaker 1. Make - ABB 2. Air pressure blocking a. Close Block - 17.3 bar. b. Open block - 16.7 bar. c. Auto reclose block - 19 bar. 3. SF6 pressure block a. Alarm - 5. ... , storage and erection. Rated voltage : 216 kV rms. Operating voltage : 184 kV rms. 

Description : Why in transformer the LV CB also be tripped along with HV CB for a primary side fault?

Last Answer : Auxiliary transformer 415v delta star transformer, if HV CB alone tripped then back feeding from LV side (say DG runs parallel with transformer)—arcing voltage at the fault on primary—fault fed for more time – more damage.  

Description : For interrupting capacitive currents which Circuit Breaker (CB) is used a) SF6 CB b) Oil CB c) Vacuum CB d) Air blast CB

Last Answer : Ans: Vacuum CB

Description : Can I adjust the incline on the LifeSpan Fitness TR1000-HRC Treadmill?

Last Answer : The incline is adjustable on this treadmill,as is the time and distance of your workout.

Description : The first non-transgenic HRC such as triaz ine resistant canola was developed in a). 1995 b). 2000 c). 1997 d). 1984

Last Answer : d). 1984

Description : What is the advantage of HRC fuses when compared with rewireable fuses?

Last Answer : Ans.HRC fuses have high rupturing capacity, high speed of operation and no aging effect.

Description : Booster transformer should never: a) Have fuse in the HV winding b) Be left open circuited c) Be left closed circuited d) None of the above

Last Answer : Ans: B

Description : Which one of the following applications software’s is used to obtain an accurate root locus for? a) LISP b) MATLAB c) dBase d) Oracle Ans: B 6.Lenz devised a rule to find out direction of a)current induced in a circuit b)electromagneticdifference c)potential difference d)flow of power in fuse

Last Answer : Ans: A

Description : When changing fuses, you should always _____________. A. wear rubber boots B. use a fuse puller C. stand on a rubber mat D. wear safety glasses

Last Answer : Answer: B

Description : Which of the following precautions should be taken when a blown fuse, rated at 10 amperes, is replaced? A. Short out the fuse before removing it from the circuit. B. Use needle-nose pliers to ... D. Fuses of 10 ampere rating and less are virtually harmless when energized and may be handled freely.

Last Answer : Answer: C

Description : If a voltage tester is being used to check for defective fuses in the circuit, shown in the illustration, which of the readings will indicate that fuse #2 is open? EL-0062 A. C-B full voltage B. A-D full voltage C. A-D no voltage D. C-B no voltage

Last Answer : Answer: C

Description : If fuse 'F-1' in the illustrated schematic diagram opens, ____________. EL-0017 A. the motor will run slowly B. 'A-1' and 'A-2' will open C. the motor will not start D. the start button will jam in the closed position

Last Answer : Answer: C

Description : In the lighting distribution circuit shown in the illustration, if all switches are closed and fuse 'F2' were to open, all lights on branches ____________. EL-0013 A. '1', '2', and '3' would go out B. '1' ... and '3' would burn dimly D. '1' and '3' would go out, while branch '2' would remain lit

Last Answer : Answer: D

Description : The schematic diagram shown in the illustration uses symbol 'A' to represent a/an _________. EL-0011 A. non-renewable fuse link B. circuit breaker coil C. overload relay coil D. thermal overload heater

Last Answer : Answer: D

Description : In order to safely carry out repairs to a generator circuit breaker, it must be isolated from the bus. This is accomplished by opening the _____________. A. reverse power relay B. bus disconnect link C. generator bus fuse connections D. power directional relay

Last Answer : Answer: B

Description : If fuse #1 shown in the illustration is defective, a voltage tester connected across points 'C' and 'B' will ____________. EL-0062 A. show a reading of 55 volts B. show full line voltage ... C. give positive indication that fuse #2 is good D. give positive indication that fuse #1 is defective

Last Answer : Answer: D

Description : In order to determine whether or not 'fuse 2' shown in the illustration is defective, you should connect the voltage tester leads across points _____________. EL-0062 A. AC B. AD C. BC D. BD

Last Answer : Answer: B

Description : In order to determine whether or not 'Fuse 1', shown in the illustration is defective, you should connect the voltage tester leads across points _____________. EL-0062 A. AC B. AD C. BC D. BD

Last Answer : Answer: C

Description : What is represented by the electric symbol figure 'D' in the illustration? EL-0005 A. Fuse B. Plug-in contact resistor C. Variable capacitor D. Electrolytic capacitor

Last Answer : Answer: A

Description : If an electric motor fails to start, you should FIRST check the _____________. A. phase sequence B. ampere load C. fuse or circuit breaker D. line frequency

Last Answer : Answer: C

Description : When testing for blown fuses in a three-phase supply circuit to a motor, you should first ___________________. A. apply the megger across the tops of the line fuses B. apply an ammeter diagonally across ... of the line fuses D. ensure the circuit is de-energized, and then use a continuity tester

Last Answer : Answer: D

Description : When an AC or a DC motor fails to start, the FIRST step in troubleshooting should be to check the ____________. A. motor windings for obvious opens B. motor controller leads for continuity C. fuse or circuit breaker D. motor controller leads for grounds

Last Answer : Answer: C

Description : In the illustration if BRANCH NO. 1 is a lighting circuit for crew's berthing, Federal Regulations (46 CFR) require the maximum fuse rating for that branch to be _________. EL-0013 A. 80% of the connected load B. 15 amps C. 20 amps D. 30 amps

Last Answer : Answer: C

Description : In the illustrated motor controller, the motor fails to start. A voltmeter reading between 1 and 6 reads line voltage, while the voltmeter reading between 2 and 6 reads 0 VAC. The problem is __________. EL- ... in the 'M' coil, 'Ma' contact/start switch or overload contacts D. fuse '10a' is blown

Last Answer : Answer: B

Description : A circuit with a blown fuse would be described as a/an _____________. A. short circuit B. open circuit C. bonded circuit D. grounded circuit

Last Answer : Answer: B

Description : A fuse will 'blow' if _____________. A. an electric motor is stopped suddenly by opening a switch B. the flow of current to the protection device is reversed C. the electrical current exceeds the rated value of the fuse D. unequal resistors are connected in parallel

Last Answer : Answer: C

Description : In addition to short circuits and sustained overloads, fuses are likely to blow due to _____________. A. loose fuse clips B. low ambient temperatures C. low contact resistance D. all of the above

Last Answer : Answer: A

Description : In the illustration if BRANCH NO. 1 is a lighting circuit for crew's berthing, 46 CFR requires the maximum fuse rating for that branch to be _________. EL-0013 A. 15 amps B. 80% of the connected load C. 20 amps D. 30 amps

Last Answer : Answer: C

Description : Using a fuse whose rating is higher than necessary ________. A. endangers the apparatus it is supposed to protect B. reduces the possibility of short circuits C. increases the efficiency of the equipment by allowing more current to be used D. wastes money because they are more expensive

Last Answer : Answer: A

Description : In the illustration, 'D' is the symbol for a/an __________. EL-0005 A. thermal overload heater B. portable cable C. fuse D. indicating lamp

Last Answer : Answer: C

Description : If a fuse of correct size and type blows frequently, ________________. A. try the next higher amperage rating B. try the next lower amperage rating C. look for trouble within the circuit D. reduce the applied voltage 10%

Last Answer : Answer: C

Description : A fuse will blow for all the listed reasons EXCEPT ________. A. excessive vibration B. extremely hot surroundings C. loose fuse clips D. low contact resistance within the fuse

Last Answer : Answer: D

Description : When troubleshooting a motor controller, all indications are that a relay coil should be energized. If there were no magnetic pull, with rated voltage measured across the coil, the most probable cause ... open C. auxiliary contact in series with the coil is defective D. relay armature is stuck

Last Answer : Answer: A

Description : When replacing fuses, always make sure _______________. A. to stand on a rubber mat and use rubber gloves B. to use insulated pliers or screwdriver C. the fuse clips are straight, tight, and in good contact D. to increase the fuse rating 10% to guard against 'nuisance blowing'

Last Answer : Answer: C

Description : When troubleshooting motor controllers, a shorted relay or contactor coil is often indicated by _______________. A. a resistance reading of 'infinity' on an ohmmeter B. charred insulation and/or a blown ... of the coil's leads to ground D. a higher-than-normal voltage reading across the winding

Last Answer : Answer: B

Description : You are using a mechanical voltage tester to check the fuses in a three-phase circuit supplying an electric motor. For which of the following reasons must the motor be stopped during the test? A. ... circuit would be indicated by the voltage tester with the circuit energized. D. All of the above.

Last Answer : Answer: B

Description : If the motor fails to start and a voltmeter reading between 1 and 6, as illustrated, indicates line voltage, your next step should be to ________. EL-0007 A. replace fuse '10a' B. replace or repair contact 'Ma' C. reset and determine the cause of the overload D. check line voltage between L1 and L3

Last Answer : Answer: C

Description : An instantaneous-trip-type fuse will _____________. A. open as soon as the load current exceeds its set point B. allow a preset delay between overcurrent and melting C. open a circuit by using a time delay element with a magnetic trip D. reset itself when the overcurrent is corrected

Last Answer : Answer: A

Description : Component 'C' in section 'I' shown in the illustration represent ____________. EL-0093 A. a selectable holding coil arrangement B. a 'fuse blown' indicator circuit C. 'reset' and 'trouble' lamps D. a handset with switch and voice elements

Last Answer : Answer: D

Description : Which of the following conditions is most likely to occur if a single element fuse were used to replace a blown dual element fuse in a motor controller circuit? A. The fuse will blow when the motor ... overheats at high motor loads. C. The motor runs at reduced voltage. D. The motor runs normally.

Last Answer : Answer: A