State the need for strictly following safety rules while working in electrical installations. 

1 Answer

Answer :

Need for strictly following safety rules while working in electrical installations:

1. To avoid the electrical shock to the human being and to provide safe guard.

2. To minimize the chances of fire hazard in the consumer premises or in installation network.

3. To get uniformness to everybody in our country.

4. For the better control simple and smooth operation of the electrical devices.

5. To minimize the chances of mechanical and electrical accidents. 

Related questions

Description : State any four IE Rules to be followed in respect of safety while working on electrical installation system.  

Last Answer : While working in an electrical installation following safety IE rules regarding with safety: 1. IE Rule 3 : Authorization 2. IE Rule 29 : Construction and maintenance of electrical supply line and apparatus ... . IE Rule 60: Test for resistance of insulation 27. IE Rule 61: Connection with earth 

Description : IE Rules of Safety

Last Answer : Rule 41 : Distinction of Circuits of Different Voltages :  The owner of every generating station, substation, junction box or pillar in which there are many circuits or apparatus, intended for ... responsible for the maintenance of his installation in each condition as to be free from danger.

Description : Explain the uses of safety rubber hand gloves and rubber mats in electrical engineering. 

Last Answer : Uses of safety rubber hand gloves in electrical engineering:  * The safety rubber hand gloves are always used for online work to insulate the human body or operator from the electrical supply. * The ... human body) is isolated from ground or earth i.e. why danger of electrical shock is avoided. 

Description : What is Diversity factor in electrical installations?

Last Answer :  Diversity factor is the ratio of the sum of the individual maximum demands of the various subdivisions of a system, or part of a system, to the maximum demand of the whole system, or part of the system, under consideration. Diversity factor is usually more than one.

Description : State any two electrical, mechanical and thermal properties of insulating materials. 

Last Answer : i) Electrical Properties of insulating material:- 1. It should have high resistance. 2. It should have high breakdown voltage. 3. It should have high dielectric strength. 4. It should have low ... . 4. Ii should have thermal Stability. 5. Co-efficient of thermal expansion should be low.

Description : If there is a great problem of discipline in your school which disrupts the routine of the school. What would you like to do to deal with such a utter chaos? Options: A) You will thrash-out the ... its support D) You think that you are here only to teach, not for guarding the peace and welfare

Last Answer : You will organise the discipline committee with the permission of the principal and implement its rules strictly

Description : Electrical Materials and Wiring Practice

Last Answer : Unit 1. Wiring components, tools and safety devices 1a. Explain safety rules/ standards in the given electrical systems. 1b. Describe the use of the given tools in the given electrical ... installations as per IE rules.  5.4 Significance and adverse effects of improper earthing systems

Description : Explain the criteria to be applied in deciding the earthing system for an electrical installation. 

Last Answer : Following criteria (factors) to be applied in deciding the earthing system for an electrical installation: (1) Temperature of soil: (2) Soil Condition: * Different soil conditions give ... resistivity of earth, which is often the most significant factor 17) Cost of the earthing pit

Description : Explain the reasons for failure of gaseous and solid dielectric materials used in electrical engineering application. 

Last Answer : Reasons for failure of gaseous and solid dielectric materials used in electrical engineering application. 1. If the system voltage increases more than breakdown voltage for some interval then ... chemical breakdown usually occurs at very high temperature and high humidity of the surrounding air 

Description : Explain with justification two uses of each of two following as an electrical conductor: (i) Brass (ii) Silver 

Last Answer :  (i) Brass:  Brass is an alloy of copper (60% ) and zinc ( 40%) ; the proportions of zinc and copper can be varied to create a range of brasses with varying properties. Brasses set ... electrical conductor:  1) In switches to minimize contact resistance 2) In measuring instruments 3) In relays 

Description : Explain the use of the following components in electrical wiring system and give specification of each: (i) MCB (ii) ELCB

Last Answer : i) MCB (Miniature Circuit Breaker)  * MCB provides short circuit protection. * MCB provides overload protection * ELCB provides earth fault protection. * MCB is in series with load and ELCB is ... The low sensitivity ELCB are used for electrical machine the rating is in between the 3A to 10 A

Description : Explain the use of following tools in carrying out electrical wiring installation: (i) Nose pliers (ii) Test lamps (iii) Crimping tools (iv) Cutter. 

Last Answer : (i) Nose pliers : To hold and tight the wires (ii) Test lamps: Verification of voltage & current in the system and also check the open circuit (iii) Crimping tools: for crimping of the lugs for wires and cables (iv) Cutter: To cut the wire and remove the insulation 

Description : Define earthing related to electrical wiring system. 

Last Answer : Definition of earthing:  * Earthing means connecting the metal body of electrical device to the general mass of earth by a wire of negligible resistance. OR * Earthing means connecting ... Earthing is the processes of connection to the specific part of installation with earth conductive surface.

Description : Name one gaseous and one liquid electrical insulation material. 

Last Answer : i) Gaseous insulating material : 1. Air 2. Nitrogen 3. Hydrogen 4. SF6 ii) liquid insulating material: 1. Transformer oil 2. Capacitor oil 3. Cable oil 4. Pyranol 5. Savotal 6. Savol 7. Vegetable oil 8. Silicon liquids 

Description : Define dielectric failure of electrical insulating material. 

Last Answer : Definition of dielectric failure of electrical insulating material. In the insulating material if the applied voltage is increased gradually then for certain value insulation will break down, ... material vanishes its insulating properties and starts conducting, also known as dielectric failure.

Description : Write any two properties of good electrical insulation material. 

Last Answer : Electrical Properties of insulating material:-  1. It should have high resistance. 2. It should have high breakdown voltage. 3. It should have high dielectric strength. 4. It should have low dielectric loss. 5. It should have low dielectric constant. 

Description : Enlist types of electrical wiring systems. Explain casing and capping type wiring system.

Last Answer : List the types of Internal wiring in residential installations - 1) Cleat wiring 2) Batten wiring 3) Wooden casing capping wiring 4) PVC conduit wiring 5) PVC casing capping ... less chances of mechanical injury. Future expansion is possible and repairing and maintenance is easily possible. 

Description : Explain the suitability of copper as an electrical conductor with reference to its mechanical and electrical properties. 

Last Answer : Following are properties of conductor:-  i) High conductivity :-  Material should have high conductivity, So that * Cross section of conductor (size) reduces, * Copper losses reduces, * So Efficiency ... ; less costly. ix) Scrap Value:-  Material should have high scrap value. 

Description : List any four applications of insulting material used in electrical fields. 

Last Answer : Applications of insulting material used in electrical fields: 1. In Electrical machines 2. In electrical transformers. 3. Transformer bushing 4. Insulators 5. Domestic equipment’s ( or any other equivalent applications) 6. Insulation on wires and cables 

Description : What are the safety precautions when working on electrical equipments?

Last Answer : Switch off power, wear proper protective clothing, safety shoes, Notice board : Do not switch on - Men at work, stand on rubber mat, remove metal rings, watch bracelets, use proper insulated tools, ... work permit. In case of electrical shock, give proper first aid, check heart beat and pulse.

Description : The illustrated motor fails to start and gives a loud hum when the start button is depressed, your first action should be to __________. EL-0007 A. disassemble the motor to fix the centrifical ... D. hold the 'M' contactor closed by hand while wearing electrical safety gloves to get motor started

Last Answer : Answer: B

Description : State any eight safety precautions to be followed while working with an electric installation. 

Last Answer : Wear safety boot and use right tool for the right job

Description : Can I use Arduino for art installations?

Last Answer : Yes, Arduino is often used for art installations by interfacing with various sensors, actuators, and other components to create interactive and dynamic art installations.

Description : Why aren't hog factory farming installations required to have on-sight waste water treatment facilities?

Last Answer : Whenever you come across anything as grossly disgusting as those monster hog factories or mountain top removal coal mining, you can be certain that something very sleazy has occurred politically. When I heard that ... you will about liberals, but you'll never find that sort of crap in a blue state.

Description : What is the name of the cool park with art installations near Berkeley, CA?

Last Answer : It sounds like the Live Oak Park Fair

Description : Are there any video file types compatible with both Windows XP and OS 10.3 and higher that do not require any extra codec installations or video player installations?

Last Answer : One I can think of is AVI. I believe Windows media player and Apple’s Quicktime player both handle that without requiring additional codec downloads. In other words, pristine just-purchased-and-unboxed machines (PC or Mac) without internet connections should be able to play AVI files.

Description : Kitchen Services is a licensed air conditioning, heating and ventilation contractor in Los Angeles, California. We specialize in Kitchen Exhaust Systems Installations, Preventive Maintenance and Repairs?

Last Answer : We provide professional air conditioning, refrigeration and kitchen hood cleaning services in Beverly Hills, Santa Monica and Los Angeles. We install new air conditioning, heating and ventilation ... We install refrigeration equipment including walk-in coolers, walk-in freezers and ice machines.

Description : What are the common mistakes people make with AC installations?

Last Answer : The common mistakes people does while AC maintenance and installing are as follows.Incorrect size of the AC unit is a common AC installation mistakeThe first and possibly the most common AC installation mistake ... then he could easily do sloppy wiring work which may not only prove risky but may eve

Description : Human habitations and installations occupy land area

Last Answer : Human habitations and installations occupy land area A. 0.366 B. 0.166 C. 0.026 D. 0.006

Description : Which commercial lodging type is located on or near U.S. installations is operated by a commercial lodging company and is corporately branded?

Last Answer : reason code

Description : Air force installations perform threat assessments to ensure they are prepared to employ threat-specific countermeasures tailored to support the missions of their instalations?

Last Answer : 1

Description : This function of your installation drf updates the crisis action team with continuing incident status and request support through the CAT when on-scene requirements surpass the installations inherant cumplative capacities.?

Last Answer : emergency operations center

Description : estimating on one off new installations will be carried out in how many stages?

Last Answer : two

Description : Pakistan, India exchange list of nuclear installations. This is according to ____ agreement.

Last Answer : 1988

Description : The plinth area of a building not includes (A) Area of the walls at the floor level (B) Internal shaft for sanitary installations up to 2 sq m. in area (C) Lift and wall including landing (D) Area of cantilevered porch

Last Answer : (D) Area of cantilevered porch

Description : The term power budgeting refers to ∙ A. the cost of cable, connectors, equipment and installation ∙ B. the loss of power due to defective components ∙ C. the total power available minus the attenuation losses ∙ D. the comparative costs of fiber and copper installations

Last Answer : C. the total power available minus the attenuation losses

Description : Which post-installations activities are recommended by SAP after the installation of an SAP ECC 6.06 system? Note: there are 2 correct answered to this question A. Restart your SAP system ... of users involved in the implementation project D. Confirm the installation in an SAP Support ticket

Last Answer : A. Restart your SAP system and check logs for errors B. Install a valid license key

Description : _____ are industrial pro ial products t ducts that aid in t hat aid in the buyer he buyer’s produc ’s production or o tion or operations, in ions, including installations and accessory equipment. a. Materials b. Parts c. Capital items d. Specialty products

Last Answer : c. Capital items

Description : List the types of Internal wiring in residential installations –

Last Answer : 1) Cleat wiring 2) Batten wiring 3) Wooden casing capping wiring 4) PVC conduit wiring 5) PVC casing capping wiring 6) Concealed wiring

Last Answer : Most common form of A.C. meters met with in every day domestic and industrial installations are induction type single phase energy meters.

Description : Do we need insurance for a strictly off road quad?

Last Answer : You should definetely buy insurance, otherwise known as a warranty in this case. The quad could be totaled during an accident and if you dont have insurance, you will need to buy a whole new quad.

Description : Explain the process and need of crimping of cable joints. 

Last Answer : The process of crimping of cable joints:  Measure the dimensions of cable and lug , select proper lug size. 1. Remove the insulation of the cable as per the measured dimension. 2. ... fastening methods are not feasible then crimping procedure is followed, then cables are connected to bus bars. 

Description : State any Four lE Rules regarding electric safety. 

Last Answer :  lE Rules regarding electric safety: 1. IE Rule 3 : Authorization 2. IE Rule 29 : Construction and maintenance of electrical supply line and apparatus 3. IE Rule 30: Service line and apparatus on ... 26. IE Rule 60: Test for resistance of insulation 27. IE Rule 61: Connection with earth 

Description : State true or false. i) An empty tree is also a binary tree. ii) In strictly binary tree, the outdegree of every node is either o or 2. A) True, False B) False, True C) True, True D) False, False

Last Answer : C) True, True

Description : State two insulators of following types along with their areas of application: (i) Class A (ii) Class E (iii) Class H 

Last Answer : Temperature class and withstand temperature ranges for them: 

Description : Define "Magneto-striction"? State the causes for loss of magnetism.

Last Answer : Magneto-striction:  Magneto-striction is the change in dimensions of ferromagnetic material, when it is magnetized Following are the causes for loss of magnetism:  1. Heating effect: Beyond a certain ... machining loss of magnetism is possible. 5. Due to Ageing: Loss of Magnetism is possible. 

Description : State the use of following: (i) Screw driver (ii) Nose pliers (iii) Wire gauge (iv) Test lamp 

Last Answer : i) Screw Driver: Usually hand-operated, for turning screws with slotted heads for losing and tightening the screws.  ii) Nose pliers : To hold and tight the wires   iii) Wire Gauge: To ... supply voltage, Verification of voltage & current in the system and also check the open circuit fault. 

Description : State the causes of deterioration of liquid and solid dielectrics. 

Last Answer : The causes of deterioration of liquid and solid dielectrics:  1. Voltage rating 2. Humidity in atmosphere or moisture content.  3. Temperature of the oil and solid dielectric material 4. Due ... cable joints and connection. 5. Increasing in supply frequency. 6. Due to unbalanced load.

Description : State any two applications of: (i) Ferromagnetic (ii) Paramagnetic material. 

Last Answer : Applications of Ferromagnetic Materials:  1. In the transformer laminations. 2. In Electrical machines as a magnetic material. 3. In Magnetic poles of motor and generator 4. Magnetic ... : 1. Solid state MASER  2. Using adiabatic demagnetization low temperature can be achieved.